HomeMy WebLinkAboutProduct Approval 0 Py
,t
SCIS Home I Log In I User Registration i Hot Topics I Submit Surcharge I Stats&Facts ; Publications I FBC Staff I BCIS Site Map I Unks I Search i
Florida
Product Approval
t •'USER:Public User
dtr-%r -
Product Approval Menu>Product or Application Search>Application Lis[>Application Detail
FL# FL17022-R6
Application Type Revision
Code Version 2014
Application Status Validated
Comments
Archived
Product Manufacturer Extreme Metal Fabricators,LLC.
Address/Phone/Email 2160 SW Poma Drive
Palm City,FL 34990
(772)872-8034
tara@extrememetalfabricators.com
Authorized Signature James Buckner
jimmy@cbuckinc.net
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City,FL 34990
(772)872-8034
richard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
L7 Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed James L. Buckner,P.E. @ CBUCK,Inc.
the Evaluation Report
Florida License PE-31242
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Michael John Riemer,P.E.
`?J Validation Checklist-Hardcopy Received
Certificate of Independence FL17022 R6 COI CertOflndeo.Ddf
Referenced Standard and Year(of Standard) Standard Year
TAS 125 2003
UL 1897 2004
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/21/2016
Date Validated 10/21/2016
Summa ry of Products
FL# Model,Number or Name Description
17022.1 1-"5V Crimp"(R6) 3/8"rib height,26 Gauge steel,24"wide panel mechanically attached to
Wood Deck with screws
Limits of Use Installation Instructions
Approved for use in HVHZ.No FL17022 R6 11 1 SVCrimr) 26ga WoodDeck EVALREPORT R6j)d
Approved for use outside HVHZ.Yes Verified By:James L.Buckner,P.E.@ CBUCK Engineering P.E.#31242
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions FL17022 R6 AE 1 5VCrimo 26ga WoodDeck EVALREPORT R6.pd
and limitations of use.Install the assembly in Created by Independent Third Party;Yes
compliance with the installation method listed in
this report and applicable code sections of FBC.
Refer to manufacturer's installation instructions
as a supplemental guide for attachment.
17022.2 2-"5V Crimp"(R6) 0.032"aluminum,lapped roof panel,mechanically attached to wood
I deck with exposed screws.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R6 IT 2 SVCrImp 032AIum WoodDeck EVALREPORT R6.1)df
Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E.@ CBUCK Engineering P.E.#31242
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions FL17022 R6 AE 2 5VCrimp 032AIum WoodDeck EVALREPORT R6.[)df
and limitations Of use.install the assembly in Created by Independent Third Party:Yes
compliance with the installation method listed in
this report and applicable code sections of FBC.
Refer to manufacturer's installation instructions
as a supplemental guide for attachment.
1
17022.3 3-"1.5"Mechanical Seam" 1.5"rib height, 16"wide,24 gauge steel,standing seam roof panel
(RS) mechanically attached to wood deck with clips and screws.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R6 11 3 1.5 MechSeam 24ga WoodDeck EVALREPORT.12df
Approved for use outside HVHZ.Yes Verified By:James L.Buckner,P.E. @ CBUCK Engineering P.E.#31242
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions FL17022 R6 AE 3 1.5 MechSeam 24ga WoodDeck EVALREPORT.pdf
and limitations of use.Install the assembly in Created by independent Third Party:Yes
compliance with the installation method listed in
this report and applicable code sections of FBC.
Refer to manufacturer's installation instructions
as a supplemental guide for attachment.
17022.4
5"Mechanical Seam" 1.5"rib height, 16"wide,0.032"aluminum,standing seam roof panel
mechanically attached to wood deck with clips and screws.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R6 11 4 1,5
Approved for use outside HVHZ-.Yes MechSeilm 032AIum WoodDeck EVALREPORT.-pdf
Impact Resistant:No Verified By: James L.Buckner,P.E.@ CBUCK Engineering P.E.#31242
Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes
Other, Refer to evaluation report for conditions Evaluation Reports
and limitations of use.Install the assembly in FL17022 R6 AE 4 1.5
compliance with the installation method listed in MechSeam 032AIum WoodDeck EVALREPORT.od
this report and applicable code sections of FBC. Created by Independent Third Party:Yes
Refer to manufacturer's Installation Instructions
as a supplemental guide for attachment. I
170215
5-"I in.Nail Strip"(115) 1"rib height,16"wide,26 gauge steel,standing seam roof panel
mechanically attached to wood deck with screws.
Limits of Use Installation Instructions
Approved for use in HVHZ,No FL17022 R6 IT 5 INallStrip 26ga WoodDeck EVALREPORT.pd
Approved for use outside 14VHZ-.Yes Verified Bv: james 1, Bkic.knpr,P.F.@ CIBUCK Fnginepring P-P.#31749
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other.Refer to evaluation report for conditions FL17022 R6 AE 5 lNailStrip 26ga WoodDeck EVALREPORT.od
and limitations of use.Install the assembly In Created by'Independent Third Party:Yes
compliance with the installation method listed in
this report and applicable code sections of FBC.
Refer to manufacturer's installation instructions
as a supplemental guide for attachment.
17022.6 6-"i in.Nail Strip"(R5) 1"rib height, 16"wide,0.032"alurninum,Standing searri roof panel
mechanically attached to wood deck with screws.
Limits of Use Installation Instructions
Approved for use lir HVHZ:No FL17022 R6 II 6 INailStrip 032A1um WoodDeck EVALREPORT,odf
Approved for use outside HVHZ:Yes Verified By:James L. Buckner,P.E. @ CBUCK Engineering P.E.#31242
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions FL17022 R6 AE 6 iNailStriD 032A1um WoodDeck EVALREPORT.pdf
and limitations of use.Install the assembly in Created by Independent Third Party:Yes
compliance with the installation method listed in
this report and applicable code sections of FBC.
Refer to manufacturer's installation instructions
as a supplemental guide for attachment.
17022.7 7-"1.5 in.Nail Strip"(R5) 1.5"rib height, 19"wide,26 gauge steel,standing seam roof panel
mechanically attached to wood deck with screws.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R6 II 7 1.5NailStrip 26ga WoodDeck EVALREPORT.odf
Approved for use outside HVHZ:Yes Verified By:James L. Buckner,P.E. @ CBUCK Engineering P.E.#31242
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions FL17022 R6 AE 7 1.5NailStrio 26ga WoodDeck EVALREPORT.odf
and limitations of use.Install the assembly in Created by Independent Third Party:Yes
compliance with the Installation method listed in
this report and applicable code sections of FBC.
Refer to manufacturer's installation instructions
as a supplemental guide for attachment.
17022.8 8-"EMAX Rib"(RS) 29 gauge steel,lapped roof panel mechanically attached to wood deck
with exposed screws.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R6 II 8 EMAX Rib 29aa WoodDeck EVALREPORT pdf
Approved for use outside HVHZ:Yes Verified By: James L. Buckner,P.E. @ CBUCK Engineering P.E.#31242
Impact Resistant:No Created by Independent Third Party: Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions FL17022 R6 AE 8 EMAX Rib 29ga WoodDeck EVALREPORT.odf
and limitations of use.Install the assembly In Created by Independent Third Party:Yes
compliance with the installation method listed in
this report and applicable code sections of FBC.
Refer to manufacturer's installation instructions
as a supplemental guide for attachment.
17022.9 9-"PBR MAX"(R5) 26 gauge steel,lapped roof panel mechanically attached to wood deck
with exposed screws.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R6 II 9 PER Rib 26ga WoodDeck EVALREPORT pdf
Approved for use outside HVHZ:Yes Verified By:James L. Buckner, P.E.@ CBUCK Engineering P.E.#31242
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions FL17022 R6 AE 9 PBR Rib 26ga WoodDeck EVALREPORT pdf
and limitations of use.Install the assembly in Created by Independent Third Party:Yes
compliance with the installation method listed in
this report and applicable code sections of FBC.
Refer to manufacturer's Installation instructions
as a supplemental guide for attachment.
Back Next
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
Pic=provide the Department y:lth an email address which can be made available to the public.To determine''you arc a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts:
tCheck -hza
CBUCK Engineering
Spectcsltt j Structural 1=nglnL=pr1ng CBUCK,Inc.Certificate of Authorization#8064
Evaluation Report
"5-V Crimp"
Metal Roof Assembly
Manufacturer:
Extreme Metal Fabricators, LLC.
2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
for
Florida Product Approval
# FL 17022.1 R6
Florida Building Code 5th Edition (2014)
Per Rule 61G20-3
Method: 1 - D
memo
Categor Qlaga;y: Roofing
Sub Catego but) - VaTeryo �: R/IetJl Rnnflner
Product:
Material:
Panel Th!^Mocss: Product: 5-V Crimp Roof Panel
PanelWldth: Material: Steel
Support: Panel Thickness: 26 gauge
Panel Width: 24"
Support: Wood Deck
Digitally signed by James L Buckner,P.E.
Electronically signed and sealed documents
shall comply with the provisions of FAC Rule
Prepared by: 61G15-23.\\�tttllllrrv��
James L. Buckner, P.E., SECB .`��\``�y'CEBs'c�tiF�'�
Florida P?16fLts§9iUAM Engineer#31242 = * No 31242
Flodda'rrofessional Engineer "3124 —
Florida iidla ;iti;t r :lt NE ID: 1916LLJ
Project
po,co. p rS,t 'Sba Galloway %0 ' STATE OF 4 �
� •
Report Noi64-f1/1 r66-5V-S6W-ER ;6` '•.RoRtoP.•'�j��
(Revises 19a�2��5► 6W-ER)
'��r�rrrltlt���
Date: 10 nt2l/ 16 j
Evaluation Report Pages 1-1
Coirr tei rts: `f
Evaluation Report Pages 1—7 2016.10.21 12:55:49-04'00'
CBUCK,Inc. - Palm Beach County,Florida
Phone:(561)491-9927• Email:chuck@cbuckinc.net•Website:www.cbuckinc.net
Mail Address:2637 E.Atlantic Blvd,#34069,Pompano Beach,FL 33062
FL#: FL 17022.1 R6
Date: 10/21/16
BUCK Engineering Report (`!o.: 2 of 7 -5V-S6!M-ER
Page 2 of 7
Specialty Structural EnQineerinq CBUCK,Inc.Certificate of Authorization#8064
Manufacturer: Extreme Metal Fabricators, LLC,
2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
http://www.extrememetalfabricators.com/
Product Name: 5-V Crimp
Product Category: Roofing
Product Sub-Category Metal Roofing
Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d)
Drodlwct'System 5-V Crimp Roof Pane 16 Gauge steel, 24" wide panel mechanically attached to
Jr�r111 tl 1 11 .1, LV V 4V. 411 attached VV
Description: Wood Deck with screws.
Product Assembly as Refer to Page 4 of this report for product assembly components/materials &
Evaluated: standards:
1. Roof Panel
2. Fasteners
3. Underlayment
4. Insulation Board (Optional)
Support: Type:
Wood Deck
(Design of support and its attachment to support framing is outside the scope of
this evaluation.)
Description:
• 15/32"or greater plywood,
• or Wood plank(min.specific gravity of 0.42)
Slope: Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2,
applicable code sections and in accordance with manufacturer's
recommendations.
Performance: Wind Uplift Resistance:
• Design Uplift Pressure (ASD): Refer to Table A
(Refer to "Table A"attachment details herein)
FL#: FL 17022.1 R6
Date: 10/21/16
CE3UCK Engineering Report No.:3 16-16
76-5V-S6W-ER
Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064
Performance Standards: The product described herein has demonstrated compliance with:
• UL580-06—Test for Uplift Resistance of Roof Assemblies
• UL 1897-04—Uplift test for roof covering systems
• TAS 125-03—Standard Requirements for Metal Roofing Systems
Code Compliance: The product described herein have demonstrated compliance with the performance
standards listed above as referenced in the current Florida Building Code.
Evaluation Report This product evaluation is limited to compliance with the structural requirements
Scope: of the Florida Building Code, as related to the scope section to Florida Product
Approval Rule 61620-3.001.
Limitations and + This evaluation report for "Optional Statewide Approval' contains technical
Conditions of Use: documentation, specifications and installation method(s) which include
"Limitations and Conditions of Use" throughout the report in accordance with
Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is
the authority to approve products under"Optional Statewide Approval'.
Option for application outside "Limitations and Conditions of Use"
+ Rule 61G20-3.005(i)(e) allows engineering analysis for"project specific approval
by the local authorities having jurisdiction in accordance with the alternate
methods and materials authorized in the Code".Any modification of the product
as evaluated in this report and approved by the Florida Building Commission is
outside the scope of this evaluation and will be the responsibility of others.
•
Th is report is a building code product evaluation per FLPE rule ('FAC) 61G15-36 to
comply with Florida product approval rule (FAC) 61G20-3.This evaluation report
is part of the Florida Building Commission approval for the listed code related
criteria. This report by James Buckner, P.E. and CBUCK Engineering is not a
design certification of code compliance construction submittal documentation,
per FBC section 107,for any individual structure,site specific or permit design.
• Deck shall be in compliance with applicable building code.
• Design of support system is outside the scope of this report.
• Fire Classification is outside the scope of Rule 61G20-3, and is therefore not
included in this evaluation.
• This evaluation report does not evaluate the use of this product for use in the
High Velocity Hurricane Zone code section. (Dade & Broward Counties)
Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.005 (3) for
manufacturing under a quality assurance program audited by an approved quality
assurance entity through Keystone Certifications, Inc. (FBC Organization ID# QUA
1824).