Loading...
HomeMy WebLinkAboutProduct Approval 0 Py ,t SCIS Home I Log In I User Registration i Hot Topics I Submit Surcharge I Stats&Facts ; Publications I FBC Staff I BCIS Site Map I Unks I Search i Florida Product Approval t •'USER:Public User dtr-%r - Product Approval Menu>Product or Application Search>Application Lis[>Application Detail FL# FL17022-R6 Application Type Revision Code Version 2014 Application Status Validated Comments Archived Product Manufacturer Extreme Metal Fabricators,LLC. Address/Phone/Email 2160 SW Poma Drive Palm City,FL 34990 (772)872-8034 tara@extrememetalfabricators.com Authorized Signature James Buckner jimmy@cbuckinc.net Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City,FL 34990 (772)872-8034 richard@emfab.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer L7 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed James L. Buckner,P.E. @ CBUCK,Inc. the Evaluation Report Florida License PE-31242 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Michael John Riemer,P.E. `?J Validation Checklist-Hardcopy Received Certificate of Independence FL17022 R6 COI CertOflndeo.Ddf Referenced Standard and Year(of Standard) Standard Year TAS 125 2003 UL 1897 2004 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/21/2016 Date Validated 10/21/2016 Summa ry of Products FL# Model,Number or Name Description 17022.1 1-"5V Crimp"(R6) 3/8"rib height,26 Gauge steel,24"wide panel mechanically attached to Wood Deck with screws Limits of Use Installation Instructions Approved for use in HVHZ.No FL17022 R6 11 1 SVCrimr) 26ga WoodDeck EVALREPORT R6j)d Approved for use outside HVHZ.Yes Verified By:James L.Buckner,P.E.@ CBUCK Engineering P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions FL17022 R6 AE 1 5VCrimo 26ga WoodDeck EVALREPORT R6.pd and limitations of use.Install the assembly in Created by Independent Third Party;Yes compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions as a supplemental guide for attachment. 17022.2 2-"5V Crimp"(R6) 0.032"aluminum,lapped roof panel,mechanically attached to wood I deck with exposed screws. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R6 IT 2 SVCrImp 032AIum WoodDeck EVALREPORT R6.1)df Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E.@ CBUCK Engineering P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions FL17022 R6 AE 2 5VCrimp 032AIum WoodDeck EVALREPORT R6.[)df and limitations Of use.install the assembly in Created by Independent Third Party:Yes compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions as a supplemental guide for attachment. 1 17022.3 3-"1.5"Mechanical Seam" 1.5"rib height, 16"wide,24 gauge steel,standing seam roof panel (RS) mechanically attached to wood deck with clips and screws. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R6 11 3 1.5 MechSeam 24ga WoodDeck EVALREPORT.12df Approved for use outside HVHZ.Yes Verified By:James L.Buckner,P.E. @ CBUCK Engineering P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions FL17022 R6 AE 3 1.5 MechSeam 24ga WoodDeck EVALREPORT.pdf and limitations of use.Install the assembly in Created by independent Third Party:Yes compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions as a supplemental guide for attachment. 17022.4 5"Mechanical Seam" 1.5"rib height, 16"wide,0.032"aluminum,standing seam roof panel mechanically attached to wood deck with clips and screws. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R6 11 4 1,5 Approved for use outside HVHZ-.Yes MechSeilm 032AIum WoodDeck EVALREPORT.-pdf Impact Resistant:No Verified By: James L.Buckner,P.E.@ CBUCK Engineering P.E.#31242 Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes Other, Refer to evaluation report for conditions Evaluation Reports and limitations of use.Install the assembly in FL17022 R6 AE 4 1.5 compliance with the installation method listed in MechSeam 032AIum WoodDeck EVALREPORT.od this report and applicable code sections of FBC. Created by Independent Third Party:Yes Refer to manufacturer's Installation Instructions as a supplemental guide for attachment. I 170215 5-"I in.Nail Strip"(115) 1"rib height,16"wide,26 gauge steel,standing seam roof panel mechanically attached to wood deck with screws. Limits of Use Installation Instructions Approved for use in HVHZ,No FL17022 R6 IT 5 INallStrip 26ga WoodDeck EVALREPORT.pd Approved for use outside 14VHZ-.Yes Verified Bv: james 1, Bkic.knpr,P.F.@ CIBUCK Fnginepring P-P.#31749 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other.Refer to evaluation report for conditions FL17022 R6 AE 5 lNailStrip 26ga WoodDeck EVALREPORT.od and limitations of use.Install the assembly In Created by'Independent Third Party:Yes compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions as a supplemental guide for attachment. 17022.6 6-"i in.Nail Strip"(R5) 1"rib height, 16"wide,0.032"alurninum,Standing searri roof panel mechanically attached to wood deck with screws. Limits of Use Installation Instructions Approved for use lir HVHZ:No FL17022 R6 II 6 INailStrip 032A1um WoodDeck EVALREPORT,odf Approved for use outside HVHZ:Yes Verified By:James L. Buckner,P.E. @ CBUCK Engineering P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions FL17022 R6 AE 6 iNailStriD 032A1um WoodDeck EVALREPORT.pdf and limitations of use.Install the assembly in Created by Independent Third Party:Yes compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions as a supplemental guide for attachment. 17022.7 7-"1.5 in.Nail Strip"(R5) 1.5"rib height, 19"wide,26 gauge steel,standing seam roof panel mechanically attached to wood deck with screws. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R6 II 7 1.5NailStrip 26ga WoodDeck EVALREPORT.odf Approved for use outside HVHZ:Yes Verified By:James L. Buckner,P.E. @ CBUCK Engineering P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions FL17022 R6 AE 7 1.5NailStrio 26ga WoodDeck EVALREPORT.odf and limitations of use.Install the assembly in Created by Independent Third Party:Yes compliance with the Installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions as a supplemental guide for attachment. 17022.8 8-"EMAX Rib"(RS) 29 gauge steel,lapped roof panel mechanically attached to wood deck with exposed screws. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R6 II 8 EMAX Rib 29aa WoodDeck EVALREPORT pdf Approved for use outside HVHZ:Yes Verified By: James L. Buckner,P.E. @ CBUCK Engineering P.E.#31242 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions FL17022 R6 AE 8 EMAX Rib 29ga WoodDeck EVALREPORT.odf and limitations of use.Install the assembly In Created by Independent Third Party:Yes compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions as a supplemental guide for attachment. 17022.9 9-"PBR MAX"(R5) 26 gauge steel,lapped roof panel mechanically attached to wood deck with exposed screws. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R6 II 9 PER Rib 26ga WoodDeck EVALREPORT pdf Approved for use outside HVHZ:Yes Verified By:James L. Buckner, P.E.@ CBUCK Engineering P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions FL17022 R6 AE 9 PBR Rib 26ga WoodDeck EVALREPORT pdf and limitations of use.Install the assembly in Created by Independent Third Party:Yes compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's Installation instructions as a supplemental guide for attachment. Back Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, Pic=provide the Department y:lth an email address which can be made available to the public.To determine''you arc a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: tCheck -hza CBUCK Engineering Spectcsltt j Structural 1=nglnL=pr1ng CBUCK,Inc.Certificate of Authorization#8064 Evaluation Report "5-V Crimp" Metal Roof Assembly Manufacturer: Extreme Metal Fabricators, LLC. 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 for Florida Product Approval # FL 17022.1 R6 Florida Building Code 5th Edition (2014) Per Rule 61G20-3 Method: 1 - D memo Categor Qlaga;y: Roofing Sub Catego but) - VaTeryo �: R/IetJl Rnnflner Product: Material: Panel Th!^Mocss: Product: 5-V Crimp Roof Panel PanelWldth: Material: Steel Support: Panel Thickness: 26 gauge Panel Width: 24" Support: Wood Deck Digitally signed by James L Buckner,P.E. Electronically signed and sealed documents shall comply with the provisions of FAC Rule Prepared by: 61G15-23.\\�tttllllrrv�� James L. Buckner, P.E., SECB .`��\``�y'CEBs'c�tiF�'� Florida P?16fLts§9iUAM Engineer#31242 = * No 31242 Flodda'rrofessional Engineer "3124 — Florida iidla ;iti;t r :lt NE ID: 1916LLJ Project po,co. p rS,t 'Sba Galloway %0 ' STATE OF 4 � � • Report Noi64-f1/1 r66-5V-S6W-ER ;6` '•.RoRtoP.•'�j�� (Revises 19a�2��5► 6W-ER) '��r�rrrltlt��� Date: 10 nt2l/ 16 j Evaluation Report Pages 1-1 Coirr tei rts: `f Evaluation Report Pages 1—7 2016.10.21 12:55:49-04'00' CBUCK,Inc. - Palm Beach County,Florida Phone:(561)491-9927• Email:chuck@cbuckinc.net•Website:www.cbuckinc.net Mail Address:2637 E.Atlantic Blvd,#34069,Pompano Beach,FL 33062 FL#: FL 17022.1 R6 Date: 10/21/16 BUCK Engineering Report (`!o.: 2 of 7 -5V-S6!M-ER Page 2 of 7 Specialty Structural EnQineerinq CBUCK,Inc.Certificate of Authorization#8064 Manufacturer: Extreme Metal Fabricators, LLC, 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 http://www.extrememetalfabricators.com/ Product Name: 5-V Crimp Product Category: Roofing Product Sub-Category Metal Roofing Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d) Drodlwct'System 5-V Crimp Roof Pane 16 Gauge steel, 24" wide panel mechanically attached to Jr�r111 tl 1 11 .1, LV V 4V. 411 attached VV Description: Wood Deck with screws. Product Assembly as Refer to Page 4 of this report for product assembly components/materials & Evaluated: standards: 1. Roof Panel 2. Fasteners 3. Underlayment 4. Insulation Board (Optional) Support: Type: Wood Deck (Design of support and its attachment to support framing is outside the scope of this evaluation.) Description: • 15/32"or greater plywood, • or Wood plank(min.specific gravity of 0.42) Slope: Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2, applicable code sections and in accordance with manufacturer's recommendations. Performance: Wind Uplift Resistance: • Design Uplift Pressure (ASD): Refer to Table A (Refer to "Table A"attachment details herein) FL#: FL 17022.1 R6 Date: 10/21/16 CE3UCK Engineering Report No.:3 16-16 76-5V-S6W-ER Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Performance Standards: The product described herein has demonstrated compliance with: • UL580-06—Test for Uplift Resistance of Roof Assemblies • UL 1897-04—Uplift test for roof covering systems • TAS 125-03—Standard Requirements for Metal Roofing Systems Code Compliance: The product described herein have demonstrated compliance with the performance standards listed above as referenced in the current Florida Building Code. Evaluation Report This product evaluation is limited to compliance with the structural requirements Scope: of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61620-3.001. Limitations and + This evaluation report for "Optional Statewide Approval' contains technical Conditions of Use: documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under"Optional Statewide Approval'. Option for application outside "Limitations and Conditions of Use" + Rule 61G20-3.005(i)(e) allows engineering analysis for"project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code".Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • Th is report is a building code product evaluation per FLPE rule ('FAC) 61G15-36 to comply with Florida product approval rule (FAC) 61G20-3.This evaluation report is part of the Florida Building Commission approval for the listed code related criteria. This report by James Buckner, P.E. and CBUCK Engineering is not a design certification of code compliance construction submittal documentation, per FBC section 107,for any individual structure,site specific or permit design. • Deck shall be in compliance with applicable building code. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization ID# QUA 1824).