HomeMy WebLinkAboutEngineering B- -B
Engineering Consultants, Inc.
2237 Woods Edge Circle Orlando FL 32817
Tel:772-708 7785&772 828 2263
October 3,2016
STRUCTURAL INSPECTION CERTIFICATION
(WITH STRUCTURAL CERTIFICATION)
Project: Re-Roof Installation for David Marante Residence at:
10701 S. Ocean Dr. # 639 Jensen Beach F1.34957
Permit for a new"Extreme Metal" 5v R 5 Palisade Metal Re-Roof Cover
Prepared for: St. Lucie County Building Department
Client: Onshore Roofing Specialist Inc. 4401 SE Commerce Ave. Stuart Fl. 34990
Background.
On September 28, 2016 B & B Engineering, Inc. was requested by OnShore Roofing Specialist Inc. a Florida
License Roofing Contractor to visited the above site to visually inspect the structure as to its ability to support
the proposed new "Extreme Meta FL 17022.1R5" 5v Crimp Metal Roof Cover installation for the above
residence.
Certification:
B & B Engineering, Inc. Certify that existing roof support structure is in good shape and capable of support the
new roof cover, Also to meet the required wind loading as per ASCE 7-10, Exposure C with 165 mph, the
existing plywood deck will be re-nailed to the existing roof structure support using galvanized steel 8d ring
shank nails at 4" on center edge and 6" center field. The new synthetic Palisades/SDP (FL. 5325-R6)
underlayment Evaluation Report S 19010 07 09 —RI FL 5325-R6 will be mechanical attached with galvanize
plastic cap as per manufactures recommendations, and the 5V 26Ga. Metal Roof System FL Approval
No.17022.IR5 w/Striations as per manufactures recommendations, and 2014 FL Building Code.
To the best of our knowledge and professional ability it is B &B Engineering Inc. opinion that the work will be
properly done and the new roof cover will be structural sound, safe and in compliance with Codes and
Manufactures specifications.
Limitations.
Our professional services have been performed, our finding obtained and our opinions prepared in accordance
with general accepted structural engineering principles and practices. This Company is not responsible for the
conclusions, opinions or recommendations made by others based on our findings. The certification submitted in
this report is based upon the field::inspection on September 29, 2016 and was intended to evaluate the existing
roof structure to assure the mtegnty,of the proposed new roof cover.
Approved,; ��
O"LMB' udez
FL License"# 55.144