HomeMy WebLinkAboutMisc Letters { n �i Project Summary Date:1012412016
- - Entire House By:RR
EDS Air Conditioning
2200 4th Avenue North Suite 1,Lake Worth,FL 33462 Phone:561-586-7090 Fax:561-586-0771 Email:infb@edsaircondltioning.com Web:wwwedsairconditioning.com
Project ® 0
For:9679 landings Dr. Pert St. Lucie
OCT ? 7 20%
Notes: Replace Ducted System with Ductless PERf,A177i", :.
St. Lucie
besign ® a
Weather.Port St.Lucie,FL,US
Winter Design Conditions Summer Design Conditions
Outside db 48. OF Outside db 95 OF
Inside db 70 OF Inside db 75 OF
Design TD 22 OF Design TD 20 OF
Daily range L
Relative humidity 50 %
Moisture difference 69 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 4624 Btuh Structure 14671 Btuh
Ducts 1438 Btuh Ducts 1618 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 6061 Btuh Use manufacturer's data n
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 16208 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 348 Btuh
Ducts 908 Btuh
Heating Coolin Central vent(0 cfm) 0 Btuh
Area(ftp) 154 15 Equipment latent load 1256 Btuh
Volume(ft') 1386 1386
Air changes/hour 0.61 0.32 Equipment total load 17464 Btuh
Equiv.AVF(cfm) 14 7 Req. total capacity at 0.70 SHR 1.9 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make
Trade Trade
Model Cond
AHRI ref Coil
AHRI ref
Efficiency 80AFUE Efficiency 0 SEER
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 OF Total cooling 0 Btuh
Actual air flow 730 cfm Actual air flow 730 cfm
Air flow factor 0.121 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.93
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
_ wri htSOft 2016-Aug-10 6
9 RightSuite®Universal RSU01836 Pagel
ACCP. _ghtsoRHVAC\ChrisMini SPlit 2TonnerWink rup Calc=MJB FrontOoorfaces:N
FORMS
FLORIDA BUILDING CODE, ENERGY CONSERVATION t �G
Residential Building Thermal Envelope Approach r-
FORM R402-2014 Chmate'Zone:0
Scope:Compliance with Section R402.1.1 of the Florida Building Code,Energy Conservation,shall be demonstrated by the use of Form R402
for single-and multiple4amily residences of three stories or less in height,additions to existing residential buildings,alterations,renovations,
and building systems in existing buildings,as applicable.To comply,a building must meet or exceed all of the energy efficiency requirements
on Table R402A and all applicable mandatory requirements summarized in Table R402B of this form.If a building does not comply with this
method,or by the UA Alternative method,it may still comply under Section R405 of the Florida Building Code,Energy Conservation.
PROJECT NAME: V2 G11 L k1� Dr BUILDER:
AND ADDRESS: S q /
OWNER: PD ST G-VG/t_„_ 3 PERMITTING OFFICE:
JURISDICTION NUMBER:
PERMIT NUMBER:
General Instructions:
1.Fill In all the applicable spaces of the"To Be Installed"column on Table R402A with the Information requested.All'To Be Installed"values must be
equal to or more efficient than the required levels.
2.Complete page 1 based on the"To Be Installed"column Information.
3.Read the requirements of Table R402B and check each box to Ihdicate,your Intent to comply with all applicable items.
4.Read,sign and date the"Prepared By"certification statement-at the bottom of page 1.The owner or owner's agent must also sign and date the form.
1. New construction,addition,or existing building 1.
2. Single-family detached or multiple-family attached 2. 5 i^,.rz -L
3. if multiple-family,number of units covered by this submission 3.
4. Is this a worst case?(yealno) 4. 0
S. Conditioned floor area(sq.ft.) 5. yq S
6. Windows,type and area
a) U-factor. 60.
b) Solar Heat Gain Coefficient(SHGC) 6b.
c) Area tic.
7. Skylights
a) U-factor: 7a. N
14
b) Solar Heat Gain Coefficient(SHGC) 7b. tV IA
8. Floor type,area or perimeter,and insulation:
a) Slab-on-grade(R-value) Be., -5 01,Gf.-140L S-
b) Wood,raised(R-value) 8b:
c) Wood,common(R-value) 8a .
d) Concrete,raised(R-value). 8d.
e) Concrete,common(R-value) Be.
9. Wall type and insulation: n
a) Exterior. 1. Wood frame(insulation R•value) Sal. -
2. Masonry(insulation R•value) W.
b) Adjacent: 1. Wood frame(insulation R-value) 9b1. r,.
2. Masonry(Insulation FI-value) 9b2.
10. Calling type and insulation /�
a) Attic(Insulation R-value) 10a. f-r4,+- c-
b) Single assembly(Insulation R-value) 10b.
11. Air distribution system:
a) Duct location,insulation 11a. fNv
b) AHU location 11 b.
c) Total duct leakage.Test report attached. 11c. cfM100 s.f. Yes 10 No 0
12. Cooling system: a)type 12a. f tt 5S
b)efficiency 12b. I G
13. Heating system: a)type 138. �c l ISS 5
b)efficiency: 13b.
14. HVAC sizing calculation:attached 14. Yes U No
15. Water heating system: a)type 15a.
�)efficiency 15b.
1 hereby certify that the fa a specifi ons covered by this form are Review of plans and specifications covered by this form Indicate
in compliance with orf, ul / Code,Energy Conservation. compliance with the Florida Building Code,Energy Conservation.Before
PREPARED BY: Date �� construction is complete,this building will be Inspected for compliance in
I hereby certifya s building i 1n compliance with the Florida Building accordance with Section 553.908,F.S.
Code,Energy Conservation. CODE OFFICIAL:
OWNERIAGENT: Date: Date:
FLORIDA BUILDING CODE-ENERGY CONSERVATION,5th EDITION(2014) R-C.3
TABLE R402A
BUILDING COMPONENT PRESCRIPTIVE REQUIREMENTS' INSTALLED VALUES
Climate Zone 1 Climate Zone 2
Windows: U-Factor=0.65' U-Factor=0.402 U-Factor=
SHGC=0.25 SHGC-0.25 SHGC=
Skylights 1.1-factor=0.75 U-factor=0.65 1Ffactor=
SHGC=0.30 SHGC=0.30 SHGC=
Doors:Exterior door U-factor=0.65' U-factor=0.40' LI-factor=
Floors:
Stab-on-Grade NR NR
Over unconditioned spaces' R-13 R-13 F?-Value=
Walls':Ext.and Adj.
Frame R-13 R-13 R Value=
Mass
Insulation on wall Interior: R-4 R-6 R-Vaiue=
Insulation on wall exterior R-3 R-4. R-Value=
Ceilings': R=30 R=38 Fl-Value=
Air infiltration: Blower door test is required on the building envelope to verify leakage<_5 ACH; Total leakage=ACH
test report provided to code official. Test reAttached?
ort
Yes No
Air distribution system':
Air handling unit. Not allowed In attic Location:
Duct R-value R-value>_R-8(supply in attics)or?R-6(all other duct locations)- R-Value=
Air leakage$: r
Duct test Postconstruction test: Total leakage 5 4 c1m/100 s.f. Total leakage= afm/100s.f.
Rough-in test Total leakage S 3 cfm/100 s.f. Test report Attached? YesNo�
Ducts In conditioned space Test not required if all ducts and AHU are In conditioned space Location:
Air conditioning system: Minimum federal standard required by NAECA".
Central system<_65,000 Btu/h SEER 13.13 SEER=
Room unit or PTAC EEA[from Table C403.2.3(3)] EER=
Other. See Tables C403.2.3(1)-(11)
Heating system: Minimum federal standard required by NAECA'
Heat pump<_65,000 Btu/h HSPF 7.7(before 1/1/15);HSPF 8.2(as of 1/1/15) HSPF=
Gas furnace,non-weatherized AFUE 80% AFUE=
Oil furnace,non-weatherized AFUE 83% AFUE=
Other.
Water heating system(storage type): Minimum federal standard required by NAECA'
Electile 40 gal:EF=0.92 Gallons=
50 gal:EF=0.90 EF=
Gas fired' 40 gal:EF=0.59 Gallons=
50 gal:EF=0.58 EF=
Other(describe):
NR=No requirement.
(1)Each component present in the As Proposed home must meet or exceed each of the applicable performance criteria in order to comply with this code using
this method.
(2)For impact rated fenestration complying with Section R301.2.1.2 of the Florida Building Code,Residential or Section 1609.1.2 of the Florida Building Code,
Building the maximum U-factor shall be 0.75 in Climate Zone-1 and 0.65 in Climate Zone 2.An area-weighted average of U-factor and SHGC shall be
accepted to meet the requirements,or up to 15 square feet of glazed fenestration area are exempted from the U-factor and SHGC requirement based on
Sections R402.3.I.R402.3.2 and R402.3.3.
(3)One side-hinged opaque door assembly up to 24 square feet is exempted from this 11-factor requirement:
(4)R-values are for insulation material only as applied in accordance with manufacturers' installation instructions. For mass wails,the"interior of wall"
requirement must be met except if at least 50 percent of the insulation required for the"exterior of wall"is installed exterior of,or integral to,the wall.
(5)Ducts&AHU installed"substantially leak free"per Section R403.2.2.Test required by an energy rater certified in accordance with Section 553.99,Florida
Statutes,or as authorized by Florida Stances.The total leakage test is not required for ducts and air handlers located entirely within the building thermal
envelope.
(6)Minimum efficiencies are those set by the National Appliance Energy Conservation Act of 1987 for typical residential equipment and are subject to NAECA
n11es and regulations.For other types of equipment, see Tables C403.2.3(1-11) of the Commercial.Provisions of the Florida Building Code, Energy
Conservation.
(7)For other electric storage volumes,min.EF=0.97-(0.00132*volume).
(8)For other natural gas storage volumes,min.EF=0.67-(0.0019*volume).
TABLE R402B MANDATORY REQUIREMENTS
Component Section Summary of Requirement(s) Check
Air leakage R402.4 To be caulked,gasketed,weatherstripped or otherwise seated per Table R402.4.1.1.Recessed lighting:IC-rated as
having:5 2.0 cfm tested to ASTM E 283.
Windows and doors:0.3 cfm/sq.ft(swinging doors:0.5 cim/sf)when tested to NFRC400 or AAMA/WDMA/CSA 101/
I.S.2/A440.
Fireplaces:Tight-fitting flue dampers&outdoor combustion air.
Programmable R403.12 Where forced-air furnace is primary system,a programmable thermostat is required.
thermostat
Air distribution system R403.2.2 Ducts shall be tested to Section 803 of the RESNET standards by an energy rater certified in accordance with
8403.2.4 Section 553.99,Florida Statutes,or as authorized by Florida Statutes.Air handling units are not allowed In attics..
Water heaters R403.4 Comply with efficiencies in Table C404.2.Hot water pipes insulated to?R-3 to kitchen outlets,other cases.
Circulating systems to have an automatic or accessible manual OFF switch.Heat trap required for vertical pipe
risers.
Swimming peels&spas 8403.9 Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat
loss except if 70%of heat from site-recovered energy.Off/timer switch required.Gas heaters minimum thermal
efficiency is 82%.Heat pump pool heaters minimum COP is 4.0.
Cooling/healing 8403.6 Sizing calculation performed&attached.Special occasion cooling or heating capacity requires separate system or
equipment vartable capacity system.
Lighting equipment 8404.1 At least 75%of permanently installed fighting fixtures shall be hlgh-efficacy lamps.
� r
� CERTIFIEDo
OCT 2 701c
PERNgITTIivG
e rtif i cate f P rod u ct Rti n 5f. Lucie f�oLlnty,
AHRI Certified Reference Number: 7940753 Date: 10/19/2016
Product:Variable Speed Mini-Split Heat Pump,with Remote Outdoor Unit Air-Source, Free Delivery
Outdoor Unit Model Number:AOU24RLB
Indoor Unit Model Number:ASU24RLB
Manufacturer: FUJITSU GENERAL AMERICA, INC.
Trade/Brand name: FUJITSU
Series name:
Manufacturer responsible for the rating of this system combination is FUJITSU GENERAL-AMERICA,INC.
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity.(Bfuh):_ "-___ 24000
EERi Rating.(Cooling): 10.00 -
_ I r
SEER Rating(Cooling): 18.00 i
Heating Capacity(Btuh)@_47 F:~. '-24000 -
Region IV HSPF Rating (Heating): 10.60 ! '�-
Heating.Capacity(Btuh)@ 17 F: . 15300.
CERTIFIED RATINGS FOR VARIABLE-SPEED,MINI-AND MULTI-SPLIT SYSTEMS ARE VALID FOR ALL COMBINATIONS OF INDOOR UNITS
(BASED ON COMBINATION TYPES)WITH THE SPECIFIC OUTDOOR UNIT LISTED ABOVE AND IN THE AHRI DIRECTORY OF CERTIFIED
EQUIPMENT.VISIT WWW.AHRIDIRECTORY.ORG TO VERIFY THAT THIS COMBINATION IS AN ACTIVE LISTING AND THE DATA LISTED ON
THIS CERTIFICATE IS ACCURATE.SEARCH ON THE AHRI REFERENCE#TO QUICKLY LOCATE THIS COMBINATION IN THE DIRECTORY.
"Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the
directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and
confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; AM
entered into a computer database;or otherwise utilized,In any form or manner or by any means,except for the user's individual,
personal and confidential reference. AIR-CONDITIONING,HEATING.
CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE
The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we make lile better'°
and enter the AHRI Certified Reference Number and the date on which the certificate was issued,
which is listed above,and the Certificate No.,which is listed at bottom right.
131213792252326079
©2014 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: