Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval (2)
Florida Building, Code Online Page i of Z 3F" 2 6CIS Home Log to User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Flap links Search ft!Si1It_..;.. ;Prod � � "; uct Approval rafeSS101'1' �- %USER:Public User '2'`1 Xf.;^ +„+_.•y�, a�_+_.k Product Approval hlenq>Product or Aoolicat=on Search>aonlicalion List>Application Detail FL 1:1-10674-RIO OCT 63C�tC Application Type Revision Code Version 2014 PEREi.OilTfl;,1'= Application Status Approved 8f. LUCie CCt!ni " Comments Archived Product Manutacturer Owens Corning Address/Phone/Email One Owens Corning Parktvay Toledo,OH 43659 (740)404-7829 greg.keelei,@owenscorniiig.com Authorized Signature Grea Keeler cireq.keeler@otveiiscorriiilq.com Technical Representative Fiel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419)376-8360 rnei.sailcraiit@ovjet)scor.-iig.com Quality Assurance Representative Address/Phone./Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Mame who developed Robert J.M. tlieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/20(2017 Validated By John 44r. Knezevich,PE J Validation Checklist-Hardcopy Received Certificate of Independence FL10674_R10COI_2015_01_COI Mieminen,pdf Referenced Standard and Year(of Standard) standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2003 Equivalence of Product Standards Certified By Sections froth the Code littp-H\vww.tlor-IdabLlitdiiig.org/pr/pr app dtl.aspx?paratii=�vGEV yQ4vtDgtBNbEY5V%2... 9/1-5/2015 Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 04/22/2015 Date Validated 04/23/2015 Date Pending FBC Approval 04/25/2015 Date Approved 06/23/2015 Summary of Products FL# Model,Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge Shingles and Starters shingles Limits of Use Installation Instructions Approved for use in HVHZ:No FL10674 R10 II 2015 04 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674-R10.pdf Impact Resistant:N/A Verified By: Robert J.M. Nieminen PE-59166 Design Pressure:N/A Created by Independent Third Party:Yes Other: Refer to ER,Section 5. Evaluation Reports FL10674 R10 AE 2015 04 FINAL ER OC ASPHALT SHINGLES_FL1G674=R10_pdf Created by Independent Third Party:Yes Backs Next Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility statement::Refund Statement Under Florida law,email addresses are public records.if you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.`Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department Crich an email address:which can be made available to the public.To determine if you are a licensee under Chapter 455,FS.,please click here. - Product Approval Accepts: El� EE; vcttritc=�- .•� http://www.floridabuilding.orglpr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 VD/D2... 9/1-5/2015 EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization 119503 353 CHRISTIAN STREET, UNIT#13 f ; E RD OXFORD,CT 06478 PHONE:(203)262-9245 FAX:(203) 262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R5 One Owens Corning Parkway FL10674-R10 Toledo,OH 43659 Date of Issuance:02/06/2012 Revision 5: 04/22/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014)Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity l ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: y - Robert J.M.Nieminen,P.E. ?,;U3:^ .• The facsimile sea]apThisdoesotserveasans authorized Robert Nieminen, kt:' P.E.on 04/22/2015.This does not serve as an electronically signed Florida Registration No.59166,Florida DCA ANE2983 -. document.Signed,sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. N " ERS ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. Z. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: Enti Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire—are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration', TruDefinition' Duration', Duration' Premium Cool, TruDefinition' Duration' Designer Color Collection, TruDefinition'Oakridge',Oakridge and WeatherGuard HP are fiberglass reinforced,laminated asphalt roof shingles. 4.2 Berkshire' Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidge"" Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for us in all wind zones up to V.sd=150 mph(V„1t=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip&ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for us in all wind zones up to Vwd=150 mph.(V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R5 Certificate of Authorization 719503 FL10674-R10 Revision 5:04/22/2015 Page 2 of 6 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule 61620-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four(4)nails per shingle in accordance with FBC Sections 1507.2 or R905.2,with the following exceptions: r Berkshire shingles require minimum five(5)nails per shingle. ➢ WeatherGuard�HP shingles require minimum six(6)nails per shingle. Devonshire'shingles require minimum six(6)nails per shingle. Starter Strip Plus requires minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing—Classic°&Supreme: a r � Normal Mansard or Aroa para Normal Mansard or Area para Wind Areas High Wind desvanos y Wind Areas High Wind desvanes y Area pore vientos normales Areas vientos fuerres Area para vientos normales Areas vientos fuertes r--V .(A)\R!? ll �V 2"1 IBI �z.. �. t T lA1 "Z (�" z" (6) r2' t'Z 12 t2 ' 71 5"Exposure 5 5/8"Exposure Exposition Exposition 6.2.6 Minimum Nailing—Berkshire°: Sealant strip Scalant strip La tira de ieNadcr La lira de sFl"- r 1---! a ! - 04---------- O 0E 0-04 � © 04----------3-04------ m 8 cif' p ae e o y. T� 2" iashhatt rooting content Cemento de who de astaho Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS certificate of Authorization#9503 FL10674-R10 Revision 5:04/22/2015 Page 3 of 6 ' .---` � ! ' I Mi 0 0 }«—^^^�V���� ' 5.2.7 Minimum Nailing—oevonsh,e": Nails L_ Nails Ten V Spots of Asphalt Roof Cernent 6.2.8 Minimum Nailing—ou,ationw TruDefinitionO Duration,DurationO Premium Cool&TruDefinition Duration Designer Color Collection: ~ ` Area de datvsSurerlaiP ova Q,V0.I a 0 _j si6 S v;%3-Fb prite 5%"exposure Nail, 5W'Exposure 6.2.9 Minimum Nailing—Tmoe nition~DakridDe''OukridueO: 4 Nail Pattern 6 Nail Pattern 5 518"Exposure FA-p aFicion de'618 p uIg. Nails 6 518"exposure Nails 5 5f8'Expost I 6.2.10 Minimum Nailing—VVeathe,suand*HP: -1. sinul side VVw Exterior Research and Design,LLC. Evaluation Report oazy«uuz.zz-ns Certificate"fAuthorization usm pc10674-noo Revision s:w4/22/a 15 Page«mo RIYE 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire' Hip and Ridge Shingles, High Ridge, Hip& Ridge with Sealant, WeatherGuard' HP Hip and Ridge Shingles and ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions, using four(4)nails per shingle. Installation of DuraRidge-1 Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,using two(2)nails per shingle. Referto Owens Corning published information on wind resistance and installation limitations,including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements,but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing–Berkshire,'Hip&Ridge and High Ridge: Fig.1 Fig.2 � Pn?vA1inUALu1 /j��� �• Diredlml �� •;� v\.`" TOP Vias sideVlea a� ati` tJSts I tlals 17 Pime .-`, f/:^'�- =L,—=\ I i Z I IoP Laninatnl I`-y I•l V V V V -1 ExPosrur. ., � ul 6.3.4 Minimum Nailing–Hip&Ridge with Sealant: nem Fest. 2 - High Wind Fas7lMiing NMIM (4 Nails) rain smnq"3�—f and Diss-d ar Mxcess -*p y 1! rg IF H 9 Seaaa�St66p T 12" Fastening S"Exposum 13istanC-0 6.3.5 Minimum Nailing-WeatherGuard®HP Hip and Ridge: Fig.C Hip&Ridge Shingle Fastening Fig.A 9 �—�. -, TopvJx^, E—Dlmctbn 4 NaIL NaIL^ t A,`• I o\ I I 2.. ; 2.. Vi �s Eiposum .. -1 Ezposum Exterior Research and Design,LLC. Evaluation Report 037940.02.12-115 Certificate of Authorization#9503 FL10674-R10 Revision 5:04/22/2015 Page 5 of 6 TRINITYI ER 6.3.6 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard 11"— Fastening Wind Direction Sealant Strip \ Pattern 6"Exposure 0t 12' I Sealant y Fasten 7112"1\ 71? g Exposure Cover Exposed 1 Fasteners%vith Roof Cement 6.3.7 Minimum Nailing—DuraRidge—Hip&Ridge Shingles: Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. PracaiingYAM Dirocdcn Top vivo 'r—Diroaion dermrontodu v nt We eft plan DiracdtndQ1-Amto prad:niranto 4 sVI" Vista superior I'Iy y ci"" `�;• �any e. ermns coiningstu., 1 •8 „`tnfi Sy 1.y l l I �` \\1 • I l I I C I v L i , 8" aha V fi pus-: ala� i�3bF:4�ll�t{ IBJ 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(414)248-6409;karen.buchmannPul.com - END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS Certificate of Authorization#9503 FL10674-R10 Revision 5:04/22/2015 Page 6 of 6 Schedule Inspections Page 1 of 2 jo �_ cecoiti+:e to Eta¢ o�giccaQ ai.Ee og Ette ;$�•� � , r - -�`4 c Nip, g Department �t �Ufta. R. a Building Dept Business Tax Code Compliance Online Services Helpful Links Newsletters SCHEDULE INSPECTION Click For Permit Status Codes Click For Permit Type Codes Click For Inspection Type Codes HOW TO SCHEDULE AN INSPECTION 1. Type in permit number and confirmation number below(these can be found on your receipt and your permit application),and click submit. 2. Under action available,check the box next to the inspection(s)being requested.If there is a gate code and/or lock box,click the block next to the appropriate category. 3. A field box will be available to enter the information for the gate and/or lock box codes.Enter information into Field Box.You can leave the inspector a comment in the comments text box(click and drag the triangle at the bottom right comer to expand comments box). 4. To the right,in the Date Desired textbox,will be the date of the next business day.Click in the textbox to open up a calendar to select a date to schedule future inspections.(if the date selected is in the past,the inspection will be scheduled for the next business day.If the date selected is a weekend or a holiday,the inspection(s)will be scheduled for the next business day of the date selected) 5. Click the request button at the bottom of the page.You will get a message that your inspection has been accepted and will be inspected the next business day. HOW TO CANCEL AN INSPECTION, 1. Type in permit number and confirmation number below(these can be found on your receipt and your permit application),and click submit. 2. Under action available,check the box next to the inspection(s)being cancelled. 3. Click the cancel button at the bottom of the page. 4. You will get a message that your inspection has been canceled. 5. Inspections can not be cancelled once assigned.Please contact the inspector. Permit# 11626612 3-Digit Confirmation Number 1201 Submit Clear INSPECTIONS Permit: 1626612 Type:RR-Re-Roo Status: Issued Location:2376 SE BREKENRIDGE CIR Builder: TRADE WINDS ROOFING INC Owner: MCCRAW,TOMMY. Your inspection has been accepted. Your inspection will be scheduled for 1012812016. https://pandapublicweb.cityofpsl.com/Schedulelnspection.aspx 10/27/2016 Schedule Inspections Page 2 of 2 Orange fields denote inspections requested, Light Blue fields denote inspections scheduled, and Light Green fields denote inspections inspected. Insp. Status Fee Action Date Description Seq. Date Date Date InspectorNotes Type. Available Desired Ordered Scheduled Inspected E7 Done AFFI Pass AFFIDAVIT 1 10/26/2016 View ❑Cancel DRINlo/2al2o16 DRY IN/WIN/DBUCKSM/ALL 2 SHEATH View ❑ Request rte-, ROOFROOF SHINGLES OR HOT 2 '` 0 MOP INS View Request Cancel Home Contact Us I Accessibility m 2016 City of Port St Lucie,FL•121 S.W.Port St Lucie Blvd.•Port St.Lucie,FL 34984•(772)871-5132•TDD(772)344-4169•Designed and Maintained by MIS https://pandapublicweb.cityofpsl.com/Schedulehispection.aspx 10/27/2016