Loading...
HomeMy WebLinkAboutProduct approvals is PAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie-,FL 34984 Phone(772)785 - 9888 Email pwelchinc@aol.com October 28,2016 Re: Pleasant Valley Re-Roof 10725 S. Ocean Drive Unit 284 Jensen Beach,FL 34957 SCOPE OF WORK: Remove existing roofing and install new 5-V Crimp Metal Roof(Gulf Coast Supply& Manufacturing FL# 11°651.13)at above referenced residence address over new underlayment and existing plywood sheathing. DESIGN CRITERIA: FBC 2014 ASCE?-10 PROJECT DATA: BUILDING HIEGHT=9' A=3' MEAN ROOF HIEGHT=<15' ROOF ANGLE=3:12 SHAPE=PITCHED GABLE R%4PROTANCE FACTOR= 1.00 WIND VELOCITY V ult= 165 MPH WIND VELOCITY V asd= 124 MPH EXPOSURE=D ENCLOSURE CLASS=ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT= -0.18 APPLIED UPLIFT DESIGN PRESSURES ON SLOPED ROOF (nsf): ZONE 1 (Field)=-44.7 ZONE 2 (Perimeter/Ridge)_-75.5 ZONE 3 (Comers) _-110.8 _ - = _Paul Welch Inc. Paul Welch P.E. Reg.No. 29945 October 28,2016 10725 S.Ocean Drive Unit 284 Jensen Beach,FL 34957 1 of 4 r • METAL ROOFING ATTACHMENT REQUIREMEN'T'S: Metal roofing to be attached with#9-15 x 1 Y2"long(minimum Y4"penetration through plywood sheathing)Woodgrip screws with weather sealing washers spacing as follows: ALL FASTENERS IN THE FLAT OF THE PANEL ZONE I (Field): Fasteners adjacent to ribs one side(Type 1 per product approval)at 16" O.C. ZONE 2(Perimeter/Ridge): Fasteners adjacent to ribs one side(Type 1 per product approval)at 16"O.C. ZONE 3(Corners): Fasteners adjacent to ribs both side(Type 2 per product approval) at 16"O.C. Zones 1 &2 Design uplift Pressure: -94.25 psf Zone 3 Design uplift Pressure: - 131.0 psf Zones 1 &2: 94.25>75.5>44.7 Therefore O.K. Zone 3: 131.0> 110.8 Therefore O.K. . NOTE: CONTINUOUS APPROVED LAP SEALANT MUST BE USED AT ALL PANEL SIDELAPS FOR SLOPES LESS THAN 3:12. UNDERLAYMENT: Underlayment shall be Tri-Built Roofing Products FL#.16048.1 "Tri-Built SIA HT TU". While priming is optional,TRI.-BUILT recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge.Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place,peel-off the release film diagonally while holding the membrane tight. Firmly roll the membrane into place to achieve a bond.Horizontal seams should be minimum 3-inches, configured to shed water.Vertical seams should be 6inches and staggered not less than 2-ft from vertical seams in the course below.All over-granule end- laps shall be sealed using either heat-welding or hot air welding techniques.For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place,`working_from-the center of the valley or ridge in each direction.For valleys, apply the sheet starting at the lowestpoint and work upward. Paul Welch Inc. - =Paul Welch P.E. Reg.No.29945 -:-October 28,2016 10725 S.Ocean Drive Unit 284 Jensen Beach,FL 34957 2 of 4 DECK INSTALLATION: Re-nail all plywood sheathing(15/32"thick minimum)with 8D ring-shank nails at 4" O.C. perimeter and 6 O.C.field for all zones. All work to be in compliance with product approval (FL# 11651.13), (FL# 10648.1), manufacturer's specifications, and the Florida Building Code 2014. - _Paul Welch Inc. Paul Welch P.E. Reg.No. 29945 - October 28, 2016 10725 S.Ocean Drive Unit 284 Jensen Beach,FL 34957 3 of 4 ,A., � v 4 � W 06f it 1� I � Q2 M5 lA%-C ROOF ZONE PLAN A=3' (1),Q2 ,Q3 =ZONE DESIGNA770N(TYPICAL) NOTE: CONTINUOUS APPROVED LAP SEALANT_ MUST BE USED AT ALL PANEL SIDELAPS FOR SLOPES LESS THAN 3:12'. ------- Paul _ --- Paul Welch Inc. _ _ _Paul Welch P.E. Reg.No.29945 October 28, 2016 - 10725 S.Ocean Drive Unit 284 Jensen Beach,FL 34957 / 4 of 4 ?Ot�G�iril� �icit��+ui�a� �tniGial� Business ► 1 1 . Requati A TlYh � I' ",:" i( '-_:C.7^yrT-."`:.... I .:.::T rCS. I C:.li^.i:c.�•;L^i'i'.:L^I '_ I a:C.-i '` I '..t =YL'iS I 2'^...C_'�tF' I RS• -'m r'i'S: I i4It' b a `" "" `isaa�fuctt�gaga►aval L G�.il F:ati�n Product Approval Menu>Productor Application Search>Application List>A:,�%cativa Detal 9fi_tk 1 TVPe Revision `•�`cr."�r•"t-t?'`?`.+,:;5��.iaw i9ar*rrnrt.;a'co.t. �Qtr(c(.rra� Archived Product Manufacturer TRI-BUILT Roofing Products Address/Phone/Email 9050 Louisiana Street •.r. sll 4o410 (Z) 842=2449 david.ruiz@tribuiltmateriaisgroup.com Authoil.aad david.ruizr@trioul[materiafsgroup.coni Technical Representative David Ruiz Address/Phone/Email 250 Route 17 North evf3rd; Nj 07073 tkoi)842-2449 david.ruiz@tribuiltmateriaisgroup.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance ketfiod' Evaivation'keporc rrom a r=rorrda kegistered ttrcnrted or a Licensed L Evaluation Report-i-iardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/16/2017 PE C✓, validation Checklist-Hardcopy Received Certificate of Independence FL16048 R3 COI 2015 01 COI Nieminen.pdf iReferenccu SLaiidaiu ariG ycaf �ofl Sjafrdot j) Sta aarQ � ear ASTM D1970 2009 ASTM G155 2005 i�:Ciy T Ap.ii iv12 2012 TAS 103 1995 Equivalence of Product Standards Certified By Sections from the Code niips:iiliuridabuiidirlg.LTgi'pripr_appdil.aspx%par l. wn=wGE%i CiwO�FPitiUiiND VrWipnliAnR8jv5/o2U)G2:LyZCdHEPC6)Uacy!F 1);3d%o.3d i12 10!21/20.16, Florida Building Code Online Product Approval Method Method 1 Option D L/dtN Vdridated rat/%F J%LUj Date Pending FBC Approval 10/21/2015 Dat1-A=-rcrzd2 Date Revised rCr%uo%Z0! Ssflt mart'Of Pi odm s ii¢{QP 4%li' IrTtte l 1 GlZac�t:liJ�7derrl wfanenl s, S 3t i i rimry,rlaeaGli i taiS ut�gnr r¢ak'tsrrrtlr�rts3§sr�&�t�' ams of use Instauabon L25buctilaps t;_4M=o r,Y1 v?Znit^:. EL16048 R3 II 2015 10 FINAL ER TRI- BUILT UNDERLAYMENTS FL16048-R3.Ddf impact Res6awaft lmAA ` rri ffiled By-Rabartt Iihlem kion 1 ]I65 Design Pressa>me_+IW,%R//-45 Crpzted by Dx5epamfentWird Pam:Yes .e„ IL. ri be a1 mm!{mes9ll ,mit�t4�L+l Ii+ren�ilan (i YiaRS to use Eva3 en RepaWs :ice-' FL16048 R3 AE 2015 10 FINAL ER TRI- wlid iaayMer-IL't"drwepar--D=J�Nfagpka6an,. BUILT UNDERLAYMENTS FL16048-R3.pdf 5-6 for retails.2-1 Rzfer to ER Saffian 5 for aUnafr Un Rds mfr Created by EmOepenitmft wird Pam:Yes Use. Bac& Next ' Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. ::Privacy Statement::Accessibility Statment::-Refund-St,-tem ent mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850 487.1395.'Pursuant to.Secnoe 455.275(1);Florida statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have ,ne.Tha emaJs pm'iWed...'a.!=n FO r.Y t•`*,twIirc s.w:up..•.ref omafl x!,+.vcco5:er?..r•.t447..ocnnl,If y..:tb.yet wi�b to e,lmly MV1*--,T.�Y:.Y,14.+§.T�?r,'_Y•r:a,._._.w�P."t• ..^.s..:'5.€i`r.s:..:z i:,._)r._..5 cc.;i',E',3i8-�,--ff4ai;, Z.,er,2.p.—Nc, ,a...v.2r..'..�:.,P :�2va1AScep1s: Credit Cary! .uiii7ritSaiiuiiUirf or'' i a vu dS x. rdrn`wi��Uhi.iWiLi trrrtro>ifvvvvrvvi f1(Hrtt'CO VO%ora[YIULL L�.(I-ICT'tI(:LJd(, tr(,(yoJU7oJfl ZJ� ham.<. 9• �(m EN=FW��" "N 'fes" - cl � 1 Y ! 'Y 0%77 tIOR RESEAR+Cli 4u DESIGN,LLC. Certificate of Authorization#19503 I'TRINrry E�® 353 CHRISTIAN STREET,UNIT#13 OXFORD,CT 06478 PHONE: (203)262-9245 FAX: (203)262-9243 EVALUATION REPORT Allied Building Products Corp. Evaluation Report A42960.10.12-113 dba TRI-BUILT Roofing Products FL16048-R3 9050 Louisiana Street Date of Issuance:10/25/2012 Merrillville, IN 46410 Revision 3: 10/08122015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have. been evaluated for compliance with the 5th Edition (2014) Florida. Building Code sections noted herein. DESCRIPTION: TRI-BUILT Roof Underlayrnents LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinittyl ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5. Prepared by: t�—e Robert J.M.Nieminen P.E. ,s� �" S r, The facsimile seal appearing was authorized by Robert Nieminen, }' P.E.on 10/08/2015.This does not serve as an electronically signed Florida Registration No.59166,Florida DCA ANE1983 document.signed,sealed hardcapies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Recordfor any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. r^� �JTRINrryfERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: TRI-BUILT Roof Underlayments,as produced by TRI.-BUILT,have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4,1507.2.8,1507.2.9.2, Physical Properties ASTM D1970 2009 1507.4.5.1,1507.5.3,1507.7.3 1504.6 Accelerated Weathering ASTM G155 2005 1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012 1523.6.5.2.1 Physical Properties TAS 103 1995 3. REFERENCES: En "t Examination Reference Date ERD(TST6049) Physical Properties S40540.02.13-1 02/19/2013 ERD(TST6049) Physical Properties 540540.11.13 11/19/2013 ERD(TST6049) Physical Properties 540540.03.14 03/26/2014 ERD(TST6049) Physical Properties 544870.04.14-2 04/02/2014 ERD(TST6049) Physical Properties 544870.04.14-3 04/02/2014 ERD(TST6049) Physical Properties S44870.04.14-1 04/10/2014 ERD(TST6049) Physical Properties 544870.04.14-4 04/10/2014 ERD(TST6049) Physical Properties 543530.02.14-1-R1 05/14/2014 ERD(TST6049) Physical Properties 543530.05.14 05/28/2014 ERD(TST6049) Physical Properties 540540.10.14 10/31/2014 ERD(TST6049) Physical Properties SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SC8520.04.15 05/27/2015 UL,LLC.(QUA9625) Quality Control. Multiple-Listing R16814 09/04/2015 UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.10/16/2017 4. PRODUCT DESCRIPTION: 4.1 Self-Adhering,Underlayments: 4.1.1 Tri-Built Sand-R SA Shingle Underlayment is a self-adhering, glass-mat reinforced, sand=surfaced, SBS modified bitumen roof underlayment,with a 36-inch sheet width. 4.1.2 Tri-Built S/A HT TU Underlayment is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof underlayment 4.1.3 Tri-Built Smooth HT S/A Underlayment is a self-adhering,glass-mat reinforced,film-surfaced,SBS modified bitumen roof underlayment. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation.Report, or previous.versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,U.C. Evaluation Report A42960.10.12-R3 Certificate of Authorization#9sw FL16048-R3 Revision 3:10/08/2015 Page 2 of 5 TRINrry i ER® 5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC.approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data forthe prepared roof covering. 5.5 Allowable roof covers applied atop the underlayments are as-follows: TABLE 1: ROOF COVER OP'noNs Underlayment Asphalt Nail-On Tile Foam-On Tile metal Wood Shakes Slate Shingles &Shingles Tri-Built Sand-R SA Shingle Yes No No No Yes Yes Underlayment Tri-Built S/A HT TU Yes Underlayment Yes Yes See 5.5.1 Yes Yes Yes Tri-Built Smooth HT S/A Yes No No Yes Yes Yes Underlayment 5.5.1 "Foam-On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. ➢ Tri-Built S/A HT TU Underlayment with 3Mn"2-Component Roof Tile Adhesive AH-160(FL6332)or Dow TileBond114 Roof Tile Adhesive(FL717) 5.6 Allowable substrates are noted below: 5.6.1 Direct-Bond to Deck: Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; ASTM D41 primed structural concrete. While not required over plywood,OSB or Southern Yellow Pine substrates,TRI-BUILT recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT requires- tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self- adhering underlayment. 5.6.2 Bond-to-Insulation: Tri-Built S/A HT TU Underlayment applied to: A Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile systems,insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D or TAS 114,Appendix J. 5.6.3 Bond to Mechanically Attached Base Laver: ➢ ASTM D226,Type I or II felt. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems,base layer shall be attached per minimum requirements of FRSA/TRI April 2012(04-12). Exterior Research and Design,I.I.C. Evaluation Report A42960.10.12-R3 Certificate ofAuthorization 119503 FL16048-R3 Revision 3:10/08/2015 Page 3 of 5 -JTRINITY ER® 5.6.4 Wind Resistance for Underlayment Systems in Foam-On.Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment forms part of the load'-p2th. The following wind uplift limitations apply to direct-deck underlayment systems that are not addressed in FRSA/TRI.April 2012 (04-12) and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind.loads, and reflects the ultimate passing pressure divided by-2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind pressures. 5.6.4.1 Maximum Desmon Pressure=-45.0 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional)ASTM D41 Underlayment: Tri-Built S/A HTTU Underlayment,self-adhered. 5.7 Exposure Limitations: 5.7.1 Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left exposed for longer than 30-days after installation 5.7.2 Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation. 6. INSTALLATION: 6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 Tri-Built Sand-R SA Shingle Underlayment,Tri=Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed.. 6.3.2 Non-Tile applications: While priming.is_optional,TRI-BUILT recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane tight. Firmly roll the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, conrigured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below. All-over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques. When installing at slopes above 8:12, Allied Building Products Corp recommends back-nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys,apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications(Tri-Built S/A HT TU Underlayment only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a.guideline. Tile shall be loaded and staged in a manner that prevents the slippage and/or damage to the underlayment. Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R3 Certificate of Authorization#9503 FL16048-R3 Revision 3:10/08/2015 Page 4 of 5 �PTRINITYIERD 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C.Rule 9N-3 QA requirements. 9. QUALIT`!AssURANCE ENTITY: UL, LLC—QUA9625;(314)578-3406;.k.chancellor@us.ul.com -END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R3 Certificate of Authorisation#9503 FL16048-R3 Revision 3:10/08/2015 Page 5 of 5 70121/2016 Florida Building Code Ondine lit olS Mgr '7�. BUS Horne I Log.1. Use,Registration I Hot Topics Submit Surcharge Stats&Fads Publications I FBC Staff SCIS Site Map I Links I Search Flodda i r Product Approval l(� USER*Public User U YYYTFtC'i,�'. �r P."u::.rryer:.um Product Approval Menu>Product or Application Search>Application Lilt I15,Ha 011 7rh" Search Criteria Refine Search Code Version 2014 FL# 11651 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Madel,Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results-!8ppKcations FL# Tvoe Manufacturer Validated By Status FL11651-R2 Revision Gulf Coast Supply&Manufacturing,LLC. Locke Bowden Approved History Category:Roofing (334)300-1800 Subcategory:Metal Roofing 'Approved by DSPR_Approvals try DSM shall be reviewed and ratified by the POC and/or the Commission if necessary. Contact Us::2601 Blair Stone Road.Tallahassee FL 32349 Phone:X487-1624 The State of Florida is an AA/EEO employer Corivriaht 2007-2013 State of Florida.::Pdvac"v Statertuerrt::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,ES.must provide the Department with an email address if they have one.The emaiis provided may be used for official communication with the licensee..However email addresses are public record.If you do not wish to supply a personal address,please provide the Departmentwithan email address which can be made available to the public To determine if you are a licensee under Chapter 455,ES.,please dick t1pre. Product Approval Accepts: ® ¢Check ggiiigil Credit Card Safe ldlpsJlHoridabuilding.orgfpr/pr app lsLaspx 1/1 001, N ELM GuIfCa�om�t a- SEFr�P�i 9: MANUFACTURIING 5VCRIMP 26 GA. 5VCRIMP ROOF PANEL OVER 15/32" PLYWOOD* FLO . 11651.13 R2. o PRODUCTe . . . O s ENGINEER LOAD TABLE_26 G&SVC SS Reef Panel over 15/32"Ph%vood Btl ldings:F 400 'a Roof Hies 20- €I`; oof slooe:> "1 2` -" C� _ tx i Roof. ittd s `I2t 180iTtpli,Expos T® Risk Cateago€y'lI;E-Iidosed g0ilding,lased on Flt a� €Icli€gg Code 2014. 120 130 140 150 160 1701 180 gl UND FASTENER SUBSTRATE SPEED (MIN.1/4" (MiN.15l32 ) ON CENTER ON CENTER ON CENTER ON CENTER ONCORM ON C ON CENTER Penetration} SPACING SPACING SPACING SPACING SPACING SPACING SPACING ZONE 1 #945xT.Y' ' Plywood; le TYPE:I 16'TYPE 1 16"TYPE 1` u-TYPE I IV TYPE I le TV-K I 7-TYPE 1. ZONE 2 #9-15x7.5" Plywood 16`°TYPE 1 16"TYPE 1 16 TYPE 1 160 TYPE 1 160 TYPE 1 16"TYPE 1 160 TYPE 1 ZONE 3 - 5X I s` P €Deed jj;'P 'I 16"TYPE 1 16'TYPE 1: 1�`�Y�i ' 16'TYPE 1 16•TYPE 2 1fi'?YP�2 1.)PANEL DES RIIMON:5V CFJIV a WAL 26 GRADE 8%WCO` ERAGE 2.)PANEL FASTENER:49-15X1_5a HM VdTii 6-!SEALING WASHER W/MIN.''4" PEKT-I ATIt}N- 3.)MAXIMUM ALLOWABLE PANEL.f't F'F PRESSURE:-94..25 PSO 16"O-C_FASMIXER SPACING TYPE I FASTENER PATTERN,-13'1.0 ;'SF 4 16`O.C_FASIEI��R SPACING TYPE 2 FASTENERR FATTL�'�'i BASED ON—AS 125,USWCIL 1892 tST11+9G 4.)PLYWOOD DEC'f=C%'L,tliltl_Vm'THICK PLYWOOD MUS'BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2014. 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3.12,LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.)LOAD TABLE BASED ON WWI)PRESSURES CALCULATED PER ASCE 7-10(K€2=0.85)MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2014 A2o,YE 2 HIP R IF ZWMa_'j Nate:Dimension(a)is defined as 10%of the minimum width of the building or a 40%, of the mean height of the roof wWchever is smalle,however,(a)cannot be I stiuts3 eit§xec 4%of thesnirYimnam vsridth of fire busTd'mg or 3 feet. r TYPE I FASTENER TTMN 4 ,' --------�, \ (1) #9-15 x$-11T HWH /Sealing!hasher r�,rrr�! MXE9 \�; 127d f,---------- At Panel Pap DUE2 a �- ------------------ 4 —tea TYPE 2 FASTENER PATTERN s --- �-- - (1) #9-15 x 1-11T HWH mr/Sealincg Washer --------------------a -- � 2n a — u _5u-- 2"j i 2i t Z{ a13 \-EAY-. FL411651.13 fit•AME 15,2015 _ ,r KUBN ENGINEERING, LLC 11070 1SLA\:D L.AKL ;1 �� PRODUCT I SUPPLY K MANUFACTURING k. 5VCn'o Li -7L�) • GA. 5VCRIMP PANEL . • APPROVAL O 11651.13 ■ Design Procedure: For roofs within the parameters listed on the load table,fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on.the load table, design wind loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design.The maximum fastener spacing listed herein shall not be exceeded.This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FLS 11651.13 RZ•JUNE 15,201 S PRODUCT ATIO . ® • ORA -C, FLID �� A A I Gulfs7a�� ODU PR �v � ...... & MANUFACTURING 5VC9HMP 26 GA. 5VCRIMP ROOF PANEL OVER 15./32" PLYWOOD* FLORIDA PRODUCT APPROVAL NO. 11651.13 R2 Compliance Statement The product as described in this report has demonstrated compliance with the Florida Building Code 2014, Sections 1504-3.2. Product Description: 5V Crimp Roof Panel,26 Ga. Steel,24" Coverage,through fastened roof panel with fasteners in the panel flat over minimum 1%" plywood decking. Non Structural application_ PanelMaterial/Standards-- Material: Minimum 26 Ga.Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2014 Section 1507.4.3. Paint Finish Optional Yield Strength: 80.0 ksi Corrosion Resistance:Panel Material shall comply with Florida Building Code 2014, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 24" Coverage Rib Height: 3/s" Major Rib Panel Fastener. #9-15x1.5"with seating washing in the flat of the panel or approved equal, A" minimum penetration through plywood. Corrosion Resistance:Per Florida Building Code 2014,Section 1506-6, I507.4.4 Substrate Description- Minimum 15&"thick,APA Rated plywood over supports at maximum 24" O.C- Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance wl Florida Building Code 2014. Design Uplift Pressures: Table-A" Maxim"u-mi fbtal'7,0pl&ebe'sig-,Fy, :94.25psi 1311-0 psf Fastener Pattern C- Desiqn Pressure includesa Safety Factor 2.0. FL4 11651-13 R2. JUNE 15,2-015 • RODUCTE. ALU I ATION t KUHN ENGINEERING, I.LC I 16710 ISLAND LAKES LANE'. BOCA RATO'\�. FL '349,, - ] I- COA �30404 FL R R Ulf C='To 3�t 0 G:• IDA P ' ODU TA P P CTURING R 0 5VCD 26 GA. 5VCRIN/IP ROOF PANEL OVER 15/32" PLYWOOD* 7 FLORIDA PRODUCT APPROVAL NO. 11651.13 R2 Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is 1-imited to compliance with the structural wind load requirements of the Florida Building Code 2014,as relates to Rule,61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06-Test for Uplift Resistance of Roof Assemblies • UL 1897-04-Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94 11897-98 Uplift Test Force Engineering&Testing, Inc(FBC Organization#TST-5328) Report No. 117-0053T 05&117-0331 T-08 2. Certificate of Independence By Dan Kuhn, P.E. (FL#75519)0 Kuhn Engineering, LLC (FBC Organization#ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard_ QualityAssurance Entity: The manufacturer has established compliance of roof panel products in accordance-with the Florida Building Code and Rule 61 G20-3-005(3)for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range- Minimum Slope shall comply with Florida Building Code 2014, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2014 section 1507.4.5.1 and 1507.4-5.2. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. FL#11651.13 R2,%JUNE IS,2015 EVALUATI::-0N.R-E,P` RT KUHN ENGINEERING, I.LC peg 00111w; R Gulf Caa�t� FLOWDA' PROUUCT APK-OVAI T f!R I N'G 5VCH 26 GA. 5VCRIMP ROOF PANEL OVER 15/32" PLYWOOD* 'LORIDA P'Z,0DUICT APPROVa'-, NO. 11651.13 R2 Product Evaluation Report GULF COAST SUPPLY&MANUFA-,CTURING, LLC 26 Ga. 5V Crimp Roof Panel over 15132"Plywood Florida Product Approval #'1165'1.'13 R2 Florida Building Code 2014 Per Rule 61 G20-3 Method: 1 -D Category: Roofing Subcategory: Metal Roofing Compliance Method- 61 G20-3.005(1)(d) NON HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. 14429 SW 2nd Place, Suite G30 Newben FL 32669 E%T Engineer Evaluator.- 25519 Dan Kuhn, P.E. #75519 Florida Evaluation ANE ID: 10743 Z STA7'EOF 0 vallidaton ... ... Locke Bowden, P.E. #49704 94.50 AVsbur /Place 0.61301zo-f5 Montgomery, AL 36117 Contents: Evaluation Report Pages 1 - 5 FU,1 1651.13R 2 oJUNE 15,201 5 PRODUCT t"LLIJALTIOW RtPOR.� T Kt.HN ENGINEERI.NG, LLC I 1670 ISLAND LAKES LANE. BOCA RAT'0\ FL -')349S - F1 COA='0464