Loading...
HomeMy WebLinkAboutProduct Approval SCIS Home Log In User Registration Hot Topics { Submit Surcharge Stats&Facts Publications FOC Staff BCIS Site Map Links Search Or * Product ApprovalUSER:Public User Product Approval Menu>Product or Application Search>ADelica=ion List>Apr Detail - OCT 3 1 ., ' FL# FL14088- e��L Application Type PER.'1WjTTiA1G Code Version 2014 s?. LtJCie County, Application Status Approved i=1 *Approved by I BPR.Approvals by DBPR shall be reviewed and ratified by the POC and or the Commission if necessary. W Comments Archived Product Manufacturer JELD-WEN Address/Phone/Email 3737 Lakeport Blvd Klamath Falls,OR 97601 (800)535-393 fbcl@jeld-wen.com Authorized Signature Kaede McLaug lin fbcl@jeld-wen om Technical Representative JELD-WEN Cor orate Customer Service Address/Phone/Email 3737 Lakeport 31vd. Klamath Falls„ R 97601 (800)535-393 custom erservic agents@jeld-wen.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Fixed Compliance Method Certification Mirk or Listing I Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute l 1 I Referenced Standard and Year(of Standard) Standard ! Year. TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By I I Product Approval Method Method 1 Opti n A Date Submitted 04/23/2015 I i i Date Validated 05/18/2015 OCT 3 1 12916 Date Pending FBC Approval I PER ]ITTIN2, Date Approved 05/25/2015 SL Lucie County, c=± i Summary of Products FL# Model,Number or Name Description 14088.1 Premium Atlantic Vinyl Fixed!(8300)52.125"x 75"Insulated Glass(3/16 in-3/16 out Annealed) Limits of Use Certff'Cation Agency Certificate Approved for use in HVHZ:Yes FL14088 R6 C CAC N1011678.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 08/30/2017 Design Pressure: +55/-55 Installation Instructions Other:Windows with insulated glass units wider than 36" FL14088 R6 II DP- require setting blocks.Miami-Dade NOAs: Quanex Building 55 52 125x75 Installation Instructions.adf Products,Inc PVC(12-1017.02 and 13-0425.15). Verified By: Hermes Norero 73778 Created by Independent Third Party:Yes Evaluation Reports FL14088 R6 AE PER3111.odf Created by Independent Third Party:Yes i 14088.2 Premium Atlantic Vinyl Fixed(8300)52.125'x 75"Insulated Glass(3/16 in-3/16 out Tempered) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14088 R6 C CAC N1011677.odf Approved for use outside HVHZ:Yes Qua0ty Assurance Contract Expiration Date Impact Resistant:No 08%30/2017 Design Pressure:+65/-65 Installation Instructions Other:Windows with insulated glass units wider than 36" FL14088 R6 II DP- require setting blocks.Miami-Dade NOAs:Quanex Building 65 5 .125x75 Installation Instructions.odf Products,Inc PVC(12-1017.02 and 13-0425.15). Veri led By: Hermes Norero 73778 Creted by Independent Third Party:Yes Eval}}i�ation Reports FL14088 R6 AE PER3110. df Crei ted by Independent Third Party:Yes JI 14088.3 Premium Atlantic Vinyl Fixed(8300)52.125"x 75"Insulated Glass(5/16 PVB Lam in-4/16 Annealed out) Limits of Use Certification Agency Certificate Approved for use in , es FLL 088 R6 C CAC NI011699.odf Approved for us utside H Z:Yes Quality Assurance Contract Expiration Date Impact Resistak,5 Yes 09/10/2017 Design Pressur5/-55 Installation Instructions Other:Windows ted glass units wider than 36" FL14088 R6 II DP- require setting blocks.These windows do not meet small 55 52.125x75 Im act LMI Installation Instructions. df missile impact wind-borne requirements as required by FBC, Vert led By: Hermes Norero,PE 73778 section 2411.3.3.7 when the exterior lite is annealed,These Cre ted by Independent Third Party:Yes windows meet small missile impact wind-borne protection Eval ation Reports requirements as required by FBC,section 2411.3.3.7 when FL7. 088 R6 AE PER3109.odf the exterior lite is tempered.Miami-Dade NOAs:Quanex Created by Independent Third Party:Yes Building Products,Inc PVC(12-1017.02 and 13-0425.15), Dupont PVB Interlayer(13-0129.27). 14088.4 Premium Atlantic Vinyl Fixed(8300)52.125"x 75"Insulated Glass(5/16 SGP Lam in-3/16 Tempered out) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14088 R6 C CAC NI011747.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 110/2017 Design Pressure:+65/-65 In Ilation Instructions Other:Windows with insulated glass units wider than 36" FLi 088 R6 1I DP65-65 52.125 x require setting blocks.These windows do not meet small 75 LMI Installation Instructions.odf missile impact wind-borne requirements as required by FBC, Ver fied By: Hermes Norero,PE 73778 section 2411.3.3.7 when the exterior lite is annealed.These Creted by Independent Third Party:Yes windows meet small missile impact wind-borne protection Evaluation Reports requirements as required by FBC,section 2411.3.3.7 when FL111088 R6 AE PER3112.odf the exterior lite is tempered.Miami-Dade NOAs: Quanex Cre�ted by Independent Third Party:Yes Building Products,Inc PVC(12-1017.02 and 13-0425.15), Dupont SentryGlas Interlayer(11-0624.02). Back lNext Contact Us::2601 Blair Stone Road.Tallahassel FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida,::Privacy Statement::Accessibility statement::Refund Statement 14.375'O.C. 4.5,MAX. IN.DISTANCE MASONRY INSTALLATION MAX.THRU FROM I I FOR EDGE:2 1/2' FRAME CORNERS MASONRY 2 °ad BLOCK -------------------------------- 11/4'MIN. d .° 3 EMBEDMENT 15.5'O.C. MAX.THRU FRAME 11/4'MIN. ]/4"MAX I EMBEDMENT SHIM SPACE 1/4°MAX 3' SHIM SPACE FRAME SECTION(TYP) MIN.DISTANCE VERTICAL SECTION FOR EDGE:21/2° A C 22.0 2.O mm a 5.0 mm 3.0 mm i MASONRY BLOCK ' GLASS 1 - JAMB SECTION(TYP) DOW 995 HORIZONTAL SECTION GLAZING,DETAIL j 1/4"MAX SHIM SPACE -""'------' --- d ' 4 2EMBEDMENT IM Max Frame DP RATING PACT C aQ.• MASONRY WINDOW WIDTH(52.115'YAI(.)�I BLOCK 52 1/8 x 75 +55/-55 1 YE5 MIN.DISTANCE TYPICAL ELEVATION WITH FASTENER SPACING FOR EDGE:21/2' I Installation Notes: General Notes: 1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. Use 3/16"Tapcon or equivalent fasteners through frame with sufficient length to penetrate a minimum of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida of 11/4"into concrete or masonry at each location with a 21/2"min from edge distance.For concrete Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. (min.fc=3000psi)or masonry substrate(CMU shall adhere to ASTM C90). 2. All glazing shall conform to ASTM E1300, 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 3. At minimum,glazing shall be 5mm annealed-10mm airspace-3mm annealed-2mm PVB by to the structure. The host structure is the responsibility of the architect or engineer of record for the DuPont-3mm annealed. project of installation. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind borne debris protection is mandated by local This schedule addresses only the fasteners required to anchor the building code. window to achieve the rated design pressure up to the size limitations 7. Maximum sizes are buck sizes and do not include fin or flange. noted. It is not intended as a guide to the installation process and does �� �� PROJECT ENGINEER: DATE: T 3737 Lakeport ort Blvd not address he sealing consideration that may arise in different wall `����Q' •.•''••• ••F,A ���� -- 10/14/2013 �ELD�1/EN p conditions. For the complete installation procedure,see the instructions . DRAWN BY: SCALE: Klamath Falls,OR.97601 p p •• D.Vezo NTS Phone: (541)882-3451 packaged with the window or go to 7 -• CHECKED BY: TITLE: www.jeld-wen.com/resources/installation. * = J. Kantola -n T T Lr = APPROVED BY: Premium Atlantic Vinyl Impact Fixed Window DISCLAIMER: P••; �� -- Masonry Installation (52.125"x 75") This drawing and its contents are confidential and are not to be 0 PART P 0 ECr D reproduced or copied in whole or in part or used or disclosed to others a �e8. . o; D6��4�1 except as authorized by JELD WEN Inc. 398 E�do} n �e 338 IDENTIFIER No.NCTL210-3909- -FBC CAD DW3 OF 4 PLANT NAME AND LOCATION: G.No.: REV: 00 SHEET w