HomeMy WebLinkAboutProduct Approval SCIS Home Log In User Registration Hot Topics { Submit Surcharge Stats&Facts Publications FOC Staff BCIS Site Map Links Search
Or *
Product ApprovalUSER:Public User
Product Approval Menu>Product or Application Search>ADelica=ion List>Apr Detail
-
OCT 3 1 .,
' FL# FL14088- e��L
Application Type PER.'1WjTTiA1G
Code Version 2014 s?. LtJCie County,
Application Status Approved i=1
*Approved by I BPR.Approvals by DBPR shall be reviewed and ratified
by the POC and or the Commission if necessary.
W
Comments
Archived
Product Manufacturer JELD-WEN
Address/Phone/Email 3737 Lakeport Blvd
Klamath Falls,OR 97601
(800)535-393
fbcl@jeld-wen.com
Authorized Signature Kaede McLaug lin
fbcl@jeld-wen om
Technical Representative JELD-WEN Cor orate Customer Service
Address/Phone/Email 3737 Lakeport 31vd.
Klamath Falls„ R 97601
(800)535-393
custom erservic agents@jeld-wen.com
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Fixed
Compliance Method Certification Mirk or Listing
I
Certification Agency National Accreditation&Management Institute
Validated By National Accreditation&Management Institute
l
1
I
Referenced Standard and Year(of Standard) Standard ! Year.
TAS 201 1994
TAS 202 1994
TAS 203 1994
Equivalence of Product Standards
Certified By
I
I
Product Approval Method Method 1 Opti n A
Date Submitted 04/23/2015
I
i
i
Date Validated 05/18/2015 OCT 3 1 12916
Date Pending FBC Approval I PER ]ITTIN2,
Date Approved 05/25/2015
SL Lucie County, c=±
i
Summary of Products
FL# Model,Number or Name Description
14088.1 Premium Atlantic Vinyl Fixed!(8300)52.125"x 75"Insulated Glass(3/16 in-3/16
out Annealed)
Limits of Use Certff'Cation Agency Certificate
Approved for use in HVHZ:Yes FL14088 R6 C CAC N1011678.odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 08/30/2017
Design Pressure: +55/-55 Installation Instructions
Other:Windows with insulated glass units wider than 36" FL14088 R6 II DP-
require setting blocks.Miami-Dade NOAs: Quanex Building 55 52 125x75 Installation Instructions.adf
Products,Inc PVC(12-1017.02 and 13-0425.15). Verified By: Hermes Norero 73778
Created by Independent Third Party:Yes
Evaluation Reports
FL14088 R6 AE PER3111.odf
Created by Independent Third Party:Yes
i
14088.2 Premium Atlantic Vinyl Fixed(8300)52.125'x 75"Insulated Glass(3/16 in-3/16
out Tempered)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14088 R6 C CAC N1011677.odf
Approved for use outside HVHZ:Yes Qua0ty Assurance Contract Expiration Date
Impact Resistant:No 08%30/2017
Design Pressure:+65/-65 Installation Instructions
Other:Windows with insulated glass units wider than 36" FL14088 R6 II DP-
require setting blocks.Miami-Dade NOAs:Quanex Building 65 5 .125x75 Installation Instructions.odf
Products,Inc PVC(12-1017.02 and 13-0425.15). Veri led By: Hermes Norero 73778
Creted by Independent Third Party:Yes
Eval}}i�ation Reports
FL14088 R6 AE PER3110. df
Crei ted by Independent Third Party:Yes
JI
14088.3 Premium Atlantic Vinyl Fixed(8300)52.125"x 75"Insulated Glass(5/16 PVB Lam
in-4/16 Annealed out)
Limits of Use Certification Agency Certificate
Approved for use in , es FLL 088 R6 C CAC NI011699.odf
Approved for us utside H Z:Yes Quality Assurance Contract Expiration Date
Impact Resistak,5
Yes 09/10/2017
Design Pressur5/-55 Installation Instructions
Other:Windows ted glass units wider than 36" FL14088 R6 II DP-
require setting blocks.These windows do not meet small 55 52.125x75 Im act LMI Installation Instructions. df
missile impact wind-borne requirements as required by FBC, Vert led By: Hermes Norero,PE 73778
section 2411.3.3.7 when the exterior lite is annealed,These Cre ted by Independent Third Party:Yes
windows meet small missile impact wind-borne protection Eval ation Reports
requirements as required by FBC,section 2411.3.3.7 when FL7. 088 R6 AE PER3109.odf
the exterior lite is tempered.Miami-Dade NOAs:Quanex Created by Independent Third Party:Yes
Building Products,Inc PVC(12-1017.02 and 13-0425.15),
Dupont PVB Interlayer(13-0129.27).
14088.4 Premium Atlantic Vinyl Fixed(8300)52.125"x 75"Insulated Glass(5/16 SGP Lam
in-3/16 Tempered out)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14088 R6 C CAC NI011747.odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 110/2017
Design Pressure:+65/-65 In Ilation Instructions
Other:Windows with insulated glass units wider than 36" FLi 088 R6 1I DP65-65 52.125 x
require setting blocks.These windows do not meet small 75 LMI Installation Instructions.odf
missile impact wind-borne requirements as required by FBC, Ver fied By: Hermes Norero,PE 73778
section 2411.3.3.7 when the exterior lite is annealed.These Creted by Independent Third Party:Yes
windows meet small missile impact wind-borne protection Evaluation Reports
requirements as required by FBC,section 2411.3.3.7 when FL111088 R6 AE PER3112.odf
the exterior lite is tempered.Miami-Dade NOAs: Quanex Cre�ted by Independent Third Party:Yes
Building Products,Inc PVC(12-1017.02 and 13-0425.15),
Dupont SentryGlas Interlayer(11-0624.02).
Back lNext
Contact Us::2601 Blair Stone Road.Tallahassel FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida,::Privacy Statement::Accessibility statement::Refund Statement
14.375'O.C. 4.5,MAX. IN.DISTANCE
MASONRY INSTALLATION
MAX.THRU FROM I I FOR EDGE:2 1/2'
FRAME CORNERS MASONRY
2 °ad BLOCK --------------------------------
11/4'MIN.
d .° 3 EMBEDMENT
15.5'O.C.
MAX.THRU
FRAME
11/4'MIN.
]/4"MAX I EMBEDMENT
SHIM SPACE 1/4°MAX
3' SHIM SPACE
FRAME SECTION(TYP) MIN.DISTANCE
VERTICAL SECTION FOR EDGE:21/2° A
C
22.0
2.O mm a
5.0 mm 3.0 mm
i
MASONRY
BLOCK '
GLASS 1 -
JAMB SECTION(TYP)
DOW 995
HORIZONTAL SECTION
GLAZING,DETAIL
j 1/4"MAX
SHIM SPACE -""'------' ---
d '
4 2EMBEDMENT IM
Max Frame DP RATING PACT
C aQ.• MASONRY
WINDOW WIDTH(52.115'YAI(.)�I BLOCK 52 1/8 x 75 +55/-55 1 YE5
MIN.DISTANCE
TYPICAL ELEVATION WITH FASTENER SPACING FOR EDGE:21/2'
I
Installation Notes: General Notes:
1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria
2. Use 3/16"Tapcon or equivalent fasteners through frame with sufficient length to penetrate a minimum of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida
of 11/4"into concrete or masonry at each location with a 21/2"min from edge distance.For concrete Building Code(FBC)including HVHZ and the industry requirement for the stated conditions.
(min.fc=3000psi)or masonry substrate(CMU shall adhere to ASTM C90). 2. All glazing shall conform to ASTM E1300,
3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 3. At minimum,glazing shall be 5mm annealed-10mm airspace-3mm annealed-2mm PVB by
to the structure. The host structure is the responsibility of the architect or engineer of record for the DuPont-3mm annealed.
project of installation. 4. Use structural or composite shims where required.
5. Installation methods can be interchanged within the same opening.
6. An impact protective system is not required where wind borne debris protection is mandated by local
This schedule addresses only the fasteners required to anchor the building code.
window to achieve the rated design pressure up to the size limitations 7. Maximum sizes are buck sizes and do not include fin or flange.
noted. It is not intended as a guide to the installation process and does �� �� PROJECT ENGINEER: DATE: T 3737 Lakeport ort Blvd
not address he sealing consideration that may arise in different wall `����Q' •.•''••• ••F,A ���� -- 10/14/2013 �ELD�1/EN p
conditions. For the complete installation procedure,see the instructions . DRAWN BY: SCALE: Klamath Falls,OR.97601
p p •• D.Vezo NTS Phone: (541)882-3451
packaged with the window or go to 7 -• CHECKED BY: TITLE:
www.jeld-wen.com/resources/installation. * = J. Kantola
-n T T Lr = APPROVED BY: Premium Atlantic Vinyl Impact Fixed Window
DISCLAIMER: P••; �� -- Masonry Installation (52.125"x 75")
This drawing and its contents are confidential and are not to be 0 PART P 0 ECr D
reproduced or copied in whole or in part or used or disclosed to others a �e8. . o; D6��4�1
except as authorized by JELD WEN Inc. 398 E�do} n �e 338 IDENTIFIER No.NCTL210-3909- -FBC CAD DW3 OF 4
PLANT NAME AND LOCATION: G.No.: REV: 00 SHEET
w