Loading...
HomeMy WebLinkAboutEngineering TURQUOISE Engineering, LLC Structural Engineering, Design -& Testing, CA#28948, NOA#13-0222.02 6915 Washington Rd,W Palm Beach, FL 33405/Ph. (561)804-9908/Fax(561)804-9907/e-mail:turginc@aol.com October 12, 2016 TO: St Lucie County/ Building Department FROM: Riza N. ALTAN, P.E. SUBJECT: Wind Uplift & Flat.Re-Roofing Specifications ADDRESS: YANCY Residence / '3236 West Lake Dr., Ft Pierce, FL 34982 CONTRACTOR:Larry Neese LLC,. Roofing &Waterproofing Dear Sir; The re-roofing specifications for.flat areas of the subject residence have been reviewed by myself. The purpose of this letter is to determine the wind uplift pressures and specify attachment of self-adhered base sheet. The existing -43'x49'x14' L-shaped flat roof is located in Exposure C area at mean roof height of 15 ft. The, roof consists.of 19/32" CDX plywood deck, having positive drainage. Roof design pressures; as per 2014 Florida Building Code, ASCE 7-10, 160 MPH ultimate Wind Velocity for Risk Category II in Exposure C area, using Wind Load Factor of 0.6 for ASD; are determined as follows: Field Pi = -44 psf / Perimeter (4' wide) P2= -74 psf / Corner (4'x4') P3= -111 psf. The proposed Polyglass Self-Adhered Bitumen Roof System over Wood Decks (#FL1654-R19) consists of sealed plywood seams using 4" wide Polyflex SA-V tapes followed by rolled-pressed Polyflex SA Base base sheet and heat-welded PolyFlex G granule cap sheet. The max. design pressure of-135 psf (Wood Deck, Non-Insulated, Table 1G, SystType.F, Syst#W-142, pg. 22/45) is determined to satisfy roof uplift pressures in all roof zones. Therefore, this letter is to certify that installation of Polyglass Self-Adhered Roof System (#FL1654-R19) with torch-applied :cap sheet over wood decks, as described above, conforms. to 'requirements of :2014: Florida_ Building Code which specifies 160 MPH ultimate wind velocity for Risk Category.II in Exposure C area. If you have any questions regarding this matter or I may be of further assistance, please do not hesitate to call me. Sincerely, ®�Q��,P N ��r ®®.� it +q�® o°o°oom°o off _e" A_V!° Riza N. ALTAN, P'.E. 8521 ®' °° gc s� Consulting Engine NO.38521 ~ ' STATE OF a �;