HomeMy WebLinkAboutDrawing jI 2 72" X 80" 1 36" X 80" 3 36" X 80" REPLACE DOORS IN 3 OPENINGS ONLY. NEW DOORS TO BE IMPACT RESISTANT- HURRICANE SHUTTERS NOT REQUIRED. OPENING PRODUCT DESIGN OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG. 1 36 80 20.00 4 36.1 -39.3 FL16674.1 50.0 -50.0 FRONT ENTRY-LSMI 2 72 80 40.00 4 34.4 -37.6 FL8228.8 40.0 40.0 FAMILY ROOM-LSMI 3 36 80 1 20.00 1 4 1 36.1 -39.3 1 FL16674.1 50.0 -50.0 SIDE GARAGE-LSMI REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS. NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. DOOR FRAMES#1 &#3 TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. DOOR FRAME#2 TO BE ATTACHED THROUGH EXISTING BUCKS WITH 3/16"TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES MEAN ROOF HEIGHT= 13 FT 9 IN WITTKOETTER RESIDENCE 6802 LAKELAND BOULEVARD DOOR REPLACEMENT PLAN FORT PIERCE, FLORIDA