HomeMy WebLinkAboutDrawing jI
2
72" X 80"
1
36" X 80"
3
36" X 80"
REPLACE DOORS IN 3 OPENINGS ONLY.
NEW DOORS TO BE IMPACT RESISTANT-
HURRICANE SHUTTERS NOT REQUIRED.
OPENING PRODUCT DESIGN
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG.
1 36 80 20.00 4 36.1 -39.3 FL16674.1 50.0 -50.0 FRONT ENTRY-LSMI
2 72 80 40.00 4 34.4 -37.6 FL8228.8 40.0 40.0 FAMILY ROOM-LSMI
3 36 80 1 20.00 1 4 1 36.1 -39.3 1 FL16674.1 50.0 -50.0 SIDE GARAGE-LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
DOOR FRAMES#1  TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
DOOR FRAME#2 TO BE ATTACHED THROUGH EXISTING BUCKS WITH 3/16"TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT= 13 FT 9 IN
WITTKOETTER RESIDENCE
6802 LAKELAND BOULEVARD DOOR REPLACEMENT PLAN
FORT PIERCE, FLORIDA