Loading...
HomeMy WebLinkAboutEngineering PARADISE EXTERIORS "Building Our Quality Reputation One Customer At A Time SCC131150472 Property Information Building Information Owner: LEE&DARLENE HICKEY Wind Zone: 170 MPH. Address: 4104 SMOKEY PINES CT Exposure Category: C FORT PIERCE,FL 34951 Minimum Building Dimension: 48 ft. Mean Roof Height: 12 ft. jet Risk Category: II Design Pressure Calculations Opening Location Device Device Device L Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 28 16 7 37.8 -41.0 -- --- ......... .....--- ......... - ......... .. -- . ..... ........ ......._---- _._..........----.-._ ............ .----- -- --- 2 Int 28 16 7 37.8 41.0 3 Int 28 16 7 37.8 -41.0 4 Int 28 16 7 37.8 -41.0 5 End 26 37 7 37.8 -50.6 ------..-_.-.. ----------- --.........- 6 Int 25 37 7 37.8 -41.0 7 Int 25 37 7 37.8 -41.0 8 Int 52 49 _ 7 36.4 -39.6 9 Int 47 33 7 37.6 -40.8 ..._... --............................---... --...-.......----------- ...............------ ._......_........._-..._..-- ......................... ----- 10 Int 72 49 7 35.6 -38.8 11 End 26 62 7 37.5 -50.1 12 Int 25 62 7 37.6 -40.8 13 Int 71 79 7 34.5 -37.7 14 Int 55 62 7 35.7 -38.9 15 Int 55 62 7 35.7 -38.9 16 Int 25 62 7 37.6 -40.8 17 End 25 62 7 37.6 -50.2 18 End 36 61 7 36.8 -48.5 19 Int 36 61 7 36.8 -40.0 20 Int 38 62 7 36.6 -39.8 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.5th Edition(2014)Florida Building Code. Page 1 of 1