HomeMy WebLinkAboutDrawing WIND SPEED AND EXPOSURE HAVE
DESIGN CRITERIA: BEEN DETERMINED USING THE ADVANCED
Applicable Codes,Regulations.and Standards TECHNOLOGY COUNCIL'S WEBSITE
1.The 5th Edition(2014)Florida Building Code,specifically Chapter AND GOOGLE EARTH. 1�Q•P`.• •• 'Y ���
16 Structural Design,Chapter 20 Aluminum,and Chapter 23 Wood. �Q`,•' ''
2.ASCE 7-10.
Wind Loads
1.Building Occupancy Category,Paragraph 1604.5 and Table 1604.5: -z;, d
Risk Category 2. > t-
2.Basic Wind Speed,Table 1609C,State of Florida Debris Region& -7•'.• z ••��
Basic Wind Speed,Paragraph 1609.3.1 and Table 1609.3.1 ���s •��\``
Equivalent Basic Wind Speed:VuLT=.170 MPH,YAso=132 MPH
3.Exposure Category,Paragraph 1609.4.3:,D OPENING SCHEDULE da
Scope of Work: MARK SIZE (W"xH") MANUFACTURER SERIES APPROVALS DESIGN PRESSURES ALLOWABLE STRESS
L Replacement of(2)NON-Impact Glass doors.Existing Shutters to ;A 36" X Be . PGT SH-670 FL251—R28
remain 1. 60.2 =,60.5 PSF 60.0 —73.8 PSF
O
2.Windows not within 7.Oft of building comers. O w c
ui a
Builder/Permit Application is to provide Florida Product ApprovalsLU cc
6