HomeMy WebLinkAboutProduct ApprovalFlorida Building Code Online
http://www.floridabuildirig,org/pr/pr_app dtf.aspx?parani—�r(EVX,..
Submit Surcharge Stats & Facts
> n Searc+> A,E_cati n 1.ist> Application Detail
FL #
FL2569-Rll
Application Type
Revision
Code Version
2014
Application Status
Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Publications FBC Staff 6CIS Site Ma
Soprema, Inc. (Canada)
1640 rue Haggarty
Drummondville, NON -US 00000
(819) 478-2400 Ext 3327
memath ieu @soprema.ca
Marc -Etienne Mathieu
memath ieu@soprema.ca
Marc -Etienne Mathieu
1688 lean -Berch ma ns -M ichaud
Drummondville, NON -US 00000
(819) 478-2400 Ext 3327
memath ieu@soprema. ca
lean -Francois Cote, Ph.D.
1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect o
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Robert J. M. Nieminen
PE -59166
UL LLC
10/16/2017
John W. Knezevich, PE
of 3 I/5/2016 3:08 PM
7lorida Building Code Online
http://www.flori dabuilding- org/pr/pi_app_dti. aspx?param—wGEV X...
Validation Checklist - Hardcopy Received
Certificate of Independence- 9 � }.l_co, 2011_ _r-_ C01
Referenced Standard and Year (of Standard) Standard
ASTM D1970
ASTM D6163
ASTM D6164
FM 4474
FRSA/TRI April 2012 (04-12)
TAS 103
TAS 110
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
10/15/2015
Date Validated
10/19/2015
Date Pending FBC Approval
10/21/2015
Date Approved
12/15/2015
Summary of Products
FL # Morcel, Number or
Name
2569.1 Soprema Roof
Underlayments
Limits of Use
Approved for use in HVHZ: No
Approvers for use outside
HVHZ: Yes
Impact Resistant: N/A
Design Pressure, +N/A/ -90
Other: 1.) Refer to ER Section 5 for
Limits of Use. 2.) The design pressure
noted herein pertains to underlayment
systems used beneath adhesive -set the
systems. Refer to ER Section 5.6.4 for
details.
Description
Self adhering roof underlayments
Installation Instructions
FL2569 R11 II 2015 10 FINAL ER Si7FREMA CA UNDERLAVP
P=_idf
Verified By: Robert Nieminen, P.E. PE -59166
Created by Independent Third Party: Yes
Evaluation Reports
FL2569 R11 AE 2015 10 FINAL ER SOPREMA CA UNDERLAY
RIi.dH`
Created by Independent Third Party: Yes
Back Next
Cont3.Ci._iw? :: I94E7 Nnrth Mnnrne Streef. Tallahassee Ft 32399 Phone, 850 -487 -IB -Z
The State of Florida is an AA/EEO employer. Coovriaht 2007-2013 State of Florida,.:; Privmv Statement :; kcm5j lits 5tataman1 :: EI
Under Florida law, email addresses are public records, If you do not want your a -mall address released in response to a public -records req
of 3 1/5/2()16 3:08 PM
Florida Building Code Online http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVX...
electronic mail to this entity. instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department wi
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. it
supply a personal address; please provide the Department with an email address which can be made available to the public. To determine ff yo
Chapter 455, F.S., please click her
Product Approval Accepts:
M e hEsR
SCc'l6Tl'tV".i. i
of 3 1/5/2016 3:08 PM
TRUNK( ; -R
EVALUATION REPORT
Soprema, Inc.
1640 rue Haggerty
Drummondville, Quebec J2C 5P8
Canada
SCOPE:
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE.: (203) 262-9245
FAX. -(203)2G2-9243
Evaluation Report S18010.06.09 -R9
FL2569-R11
Date of Issuance: 06/15/2009
Revision 9:10/12/2015
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: Soprerrla Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinityl ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 591 S6, Florida DCA ANE1983
The faesrrnHe.sea Iappear Ing was authorized by Robert Nieminen,
P.E. on 10/1212015, This does not serve as an electronics€ly signed
document, signed, sealed hardcopies have been transmitted to the
Product Approval AdmEnistrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityi ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This Is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
Tx b
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Resistance
FM 4474
2004
1507.2.4, 1507.2.8,
Physical Properties
ASTM D1970
2009
1507.2.9.2, 1507.4.5.1,
ASTM D1970 / TAS 110
2974.03.05-2
05/17/2005
1507.5.3, 1507.7.3
Wind Resistance
2778.07.05
07/15/2005
1507.11.2
Physical Properties
ASTM D6163
2000
1507.11.2
Physical Properties
ASTM D6164
2005
1523,6.5.2.1
Physical Properties
TAS 103
1995.
TAS 110
Accelerated Weathering
TAS 110
2000
1507.3.3
Installation Practice
FRSA/TRI April 2012 (04-12)
2012
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (TST6049)
ASTM 01970 / TAS 110
2968.05.04-2
05/14/2004
ERD (TST6049)
Physical Properties
2757.02.05
02/03/2005
ERD (TST6049)
ASTM D1970 / TAS 110
2974.03.05-2
05/17/2005
ERD (TST6049)
Wind Resistance
2778.07.05
07/15/2005
ERD (TST6049)
Wind Resistance
2779.11.05-R1
04/18/2007
ERD (TST6049)
TAS 103 / TAS 110
57120.1.1.07-2
11/02/2007
ERD (TST6049)
ASTM D1970 / TAS 110
S13190.02.09 -R1
04/01/2010
ERD (TST6049)
ASTM D1970 / TAS 110
531370.03.10-1-R1
04/07/2010
ERD (TST6049)
Physical Properties /Tensile Adhesion
S11150.05.10 -R1
09/09/2010
ERD (TST6049)
Physical Properties /Tensile Adhesion
511150.05.09-R2
10/05/2010
ERD (TST6049)
ASTM D1970
537210.11.11
11/09/2011
ERD (TST6049)
ASTM D1970
S40540.02.13-1
02/19/2013
ERD (TST6049)
Physical Properties/ Tensile Adhesion
S43530.02.14-1
02/21/2014
ERD (TST6049)
Physical Properties / Tensile Adhesion
SOPC-SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
SOPC-SC8S20.14
04/17/2015
M -D (CER1592)
HVHZ Compliance
09-1005.02
11/04/2010
M -D (CER1592)
HVHZ Compliance
13-0530.02
11/27/2014
ICC -ES (EVL2396)
2012, 2009 and 2006 IBC Compliance
ESR -1524
10/03.12014
PRI (TST5878)
Physical Properties
SOP -064-02-01
12/03/2013
Soprema, Inc. (PDM3511)
Equivalency Declaration
SA SMOOTH PLY 40
05/29/2015
UL, LLC (QUA9625)
Quality Control
Service Confirmation
Exp. 10/16/2017
4. PRODUCT DESCRIPTION:
4.1. Lastobond TU HT is a self -adhering, non -woven polyester fabric surfaced, SBS modified bitumen roof
underlayment.
4.2 Lastobond Shield is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment available in two widths; 36 and 45 inch.
4.3 RESISTO SA SMOOTH PLY 40 is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment; available in 3.3 ft x 65 ft rolls.
Exterior Research and Design, LLC. Evaluation Report 518010.06.09-R9
Certificate ofAuthoriration #9503 FL2569-R22
Revision 9: 20/12/2015
Page 2 of 7
5:
TNT"'Y-
4.4 Lastobond Shield HT is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified
bitumen roof underlayment.
4.5 Lastobond Pro HT -N is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment available in two widths; 36 and 45 inch.
4.6 Lastobond Pro HT -5 is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified
bitumen roof underlayment.
4.7 Lastobond 195 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof
underlayment.
4.8 Lastobond is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof
underlayment.
4.9 Lastobond Eco is a self -adhering, glass -mat reinforced, sand -surfaced, SSS modified bitumen roof
underlayment.
4.10 Lastobond Smooth Seal HT is a self -adhering, glass -mat reinforced, film -surfaced, SBS modified bitumen
roof underlayment.
4.11 RESISTO LB1236 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof
underlayment, with a 36 -inch sheet width.
4.12 PrimeSource Grip -Rite Eave & Valley Protector is a self -adhering, glass -mat reinforced, sand -surfaced, SBS
modified bitumen roof underlayment, with a 36 -inch sheet width.
4.13 RESISTO LB1244 is a self -adhering, glass -mat reinforced, sand -surfaced, 585 modified bitumen roof
underlayment, with a 44 -inch sheet width.
4.14 Colphene FR GR is a self -adhering, fiberglass reinforced, granule -surfaced, SBS modified bitumen roof
underlayment.
4,15 Unilay (e) is a mechanically attached, polyester reinforced, granule -surfaced, SBS modified bitumen roof
underlayment.
LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.L. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the underlayments are follows:
Exterior Research and Design, LLC. Evaluation Report S18010.06.09-119
Certificate of Authorization #9503 FL2569-R11
Revision 9: 10/12/2015
Page 3 of'7
TABLE 1: ROOF COVER OPTIONS
L7nderlayment
Asphalt
Nail -On
Imam -on
Metal
wood Shakes &
Slate
Shingles
Tile
Tile
Shingles
Yes
Lastobond TU HT
Yes
Yes
Yes
Yes
Yes
See 5.5.1
Lastobond Shield / Pro HT -N /
Yes
No
No
No
Yes
Yes
RESISTO SA SMOOTH PLY 40
Lastobond Shield HT / Pro HT -S
Yes
No
No
Yes
Yes
Yes
Lastobond / Lastobond 195
Yes
No
No
No
Yes
Yes
Exterior Research and Design, LLC. Evaluation Report S18010.06.09-119
Certificate of Authorization #9503 FL2569-R11
Revision 9: 10/12/2015
Page 3 of'7
Underlayment
Lastobond ECO / RESISTO
LB1236, Grip -Rite Eave & Valley
Protector/ RESISTO LB1244
TABLE 1: ROOF COVER OPTIONS
Asphalt Mail -On Foam -On Metal
Shingles Tile Tile
Yes No No No
TRINIERDTY
Wood Shakes & Slate
Shingles
Yes Yes
Lastobond Smooth Sea] HT Yes No No Yes Yes Yes
Colphene FR GR Yes Yes Yes No Yes Yes
See 5.5.1
Unilay (e) Yes Yes Yes No No No
Batten Only See 5.5.1
5.5.1 "Foam -On Tile" is limited to use of the following adhesives unless tensile adhesion / long term aging data
from an accredited testing laboratory is provided.
Underlayment Adhesive(s)
Lastobond TU HT 3M 2 -Component Foam Roof Tile Adhesive AH -160 (FL6332) or Dow Chemical TUeBondT" Roof
Tile Adhesive (FL717) 9
Colphene FR GR 3M 2 -Component Foam Roof Tile Adhesive AH -160 (FL6332) 1
Unilay (e) 3M 2 -Component Foam Roof Tile Adhesive AH -160 (FL6332)
5.6 Allowable substrates are noted below:
5.6.1 Direct -Bond to Deck: .
Lastobond Shield, Lastobond Pro HT -N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT -S, Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, RESISTO L131236, Grip -Rite Eave &
Valley Protector, RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine; ASTM D41 primed structural concrete.
Colphene FR GR applied to:
s Plywood; ASTM D41 primed plywood; ASTM D41 primed structural concrete.
N ote:
➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends
priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within
24 hours.
Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to
installation of the self -adhering underlayment.
5.6.2 Bond -to -insulation:
Lastobond Shield, Lastobond Pro HT -N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT -S, Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, RESISTO 1_131236, Grip -Rite Eave &
Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to:
➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on the systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified
design professional and installed based on testing of the insulation/underlayment system in accordance
with FM 4474, Appendix D or TAS 114, Appendix J.
Exterior Research and Design, LLC. Evaluation Report 518010.06.09-R9
Certificate ofAuthorizatioa #9503 FL2569-R11
Revision 4: 10/12/2015
Page 4 of 7
T N ER
5.6.3 Bond to Mechanically Attached Base Laver:
Lastobond Shield, Lastobond Pro HT -N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT -S, Lastobond TU HT, Lastobond, Lastobond 195, Lastobond FCO, RESISTO LB1236, Grip -Rite Eave &
Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to:
➢ ASTM 0226, Type I or II felt; Sopra-G; Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam -on the systems (Lastobond TU HT only),
base layer shall be attached in accordance with FRSA/TRI April 2012 (04-12).
5.6.4 Wind Resistance for Underlavment Svstems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications.
Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per I=BC 1504.9 has
already been applied). Refer to FBC 1609 for determination of design wind pressures.
5.6.4.1 Maximum Desian Pressure = -45.0 psf.
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional) Elastocol Stick or Elastocol 600c
Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered.
5.6.4.2 Maximum Desizn Pressure = -67.5 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: Elastocol 600c
Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered.
5.6.4.3 Maximum Desian Pressure = -60.0 psf
Deck: Min. 19/32 -inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FSC 1517.5.1) and tin
caps (FBC 1517.5.2) spaced 6 -inch o.c. at the 4 -inch laps and 6 -inch o.c. in three, equally
spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered
5.6.4.4 Maximum Desien Pressure = -90.0 psf.
Deck: Min. 19/32 -inch plywood to meet project requirements to satisfaction of AHJ.
Underlayment: Unilay(e) mechanically attached with Soprafix Polymer Batten Bar (PBB) or Soprafix
Metal Batten Bar (MBB) with Soprema #15 -EL fasteners spaced 6 -inch o.c. within the 5 -
inch wide, self -adhering side laps. End laps are 6 -inch wide and sealed using either
heat -welding or hot-air welding techniques.
5.7 Exposure Limitations:
Lastobond, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236, Grip -Rite Eave &
Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30 -days after installation.
Lastobond Shield, Lastobond Pro HT -N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond
Pro HT -S shall not be left exposed for longer than 90 -days after installation.
Lastobond TU HT or Colphene FR GR or Unilay(e) shall not be left exposed for longer than 180 -days after
installation.
Exterior Research and Design, LLC. Evaluation Report 518010:06.09-R9
Certificate of Authorization #9303 FL2569-RIl
Revision 9: 1011212015
Page 5 of 7
TRINITY -x
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick or
Elastocol 600c (if applicable).
6.3 Lastobond TU HT, Lastobond Shield, Lastobond Pro FIT -N, RESISTO SA SMOOTH PLY 40, Lastobond Shield,
HT: Lastobond Pro HT -S. Lastobond, Lastobond 195. Lastobond Eco. Lastobond Smooth Seal FIT, RESISTO
LB1236, Grin -Rite Eave & Valley Protector, RESISTO L81244 or Colphene FR GR:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile Applications:
While priming is optional, Soprema recommends priming with Eiastocol Stick or Elastocol 600c if the final
roof cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the
membrane tight. Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3 -inches, configured to shed water. Vertical seams should be 6 -
inches and staggered not less than 2 -ft from vertical seams in the course below. All over -granule end -laps
shall be sealed using either heat -welding. or hot air welding techniques.
When installing at slopes above 8:12, Soprema recommends back -nailing in the overlap area at the top of
the sheet at 12 -inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys, apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications (Lastobond TU HT or Colohene FR GR onlv):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
6.4 Unllav[e):
6.4.1 bion -Tile Aonlications or hail -On. Battened Tile Applications:
Reference is made to Table 1 herein and FRSA/TRI April 2012 (04-12) Installation Manual (if applicable).
Apply sheet parallel to the roof edge and, starting at the eave with the selvedge -edge upslope,
mechanically attach the 5 -inch wide selvedge -edge to the wood deck with nails and tin caps or round cap -
nails spaced 36 -inch o.c. Apply the second course in a water -shedding manner with self -adhering side -
laps. Vigorous hand or motorized roller pressure is applied to the self -adhering laps to ensure a watertight
application.
Vertical seams should be 6 -inches and staggered not less than 2 -ft from vertical seams in the course
below. All over -granule end -laps shall be sealed using either heat -welding or hot air welding techniques.
Exterior Research and Design, LLC. Evaluation Report S1010.06.09-119
Certificate ofAuthorizatiart 119503 FL2569-R11
Revision 9: 10/12/2015
Page 6 of 7
TRN5 tin Z.
1_ R
Tile (if applicable) shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underiayment.
6.4.E Foam -On Tile Applications:
Reference is made to FRSA/TRl April 2012 (04-12) Installation Manual, Table 1 herein and Section 5.6.4.4
herein.
Apply sheet parallel to the roof edge and, starting at the eave with the selvedge -edge upslope,
mechanically attach the 5 -inch wide selvedge -edge to the wood deck Soprafix Polymer Batten Bar (PBB) or
Soprafix Metal Batten Bar (MBB) with Soprema #15 -EL fasteners spaced 6 -inch o.c. Apply the second
course in a water -shedding manner with self -adhering side -laps. Vigorous hand or motorized roller
pressure is applied to the self -adhering laps to ensure a watertight application.
Vertical seams should be 6 -inches and staggered not less than 2 -ft from vertical seams in the course
below. All over -granule end -laps shall be sealed using either -heat -welding or hot air welding techniques.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for information on plants covered under Rule 61G20-3 QA
requirements.
9, QUALITY ASSURANCE ENTITY:
UL, LLC —QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- ENO OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation. Report 51$010.06.09-119
Certificate of Authorization #9503 FL2569-R11
Revision 9:10/12/2015
Page 7 of 7
orida Building Code Online
http://www.tioriciabull(Ima.org/pr/pr app_tlu.aspx!param=w(ivim...
n _;%> ApprIC3#Ion detail
L # FL2418-R9
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
F
Publicatio ns FBC Staff 605 Site Ma
*Approved by DBPR. Approvals by DBPR shall he reviei
by the POC and/or the Commission if necessary.
Product Manufacturer Maxim Industries, Inc.
Address/Phone/Email 1630 Terre Colony Court
Dallas, TX 75212-6221
(214)905-2021
info@maximskylights.com
Authorized Signature David Thornton
info@maximskylights.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Sky Lights
Subcategory Skylight
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation & Management Institute
Validated By National Accreditation & Management Institute
Referenced Standard and Year (of Standard) Standard Year
TAS 201 1994
TAS 202 1994
TRS 203 1994
ff3 11/23/2015 2:14 PM
orida Building Code Online
tittp://www.lioriciabLtliomg.org/pr/pr_app_ati.aspx : param=Nvur. v x...
Equivalence of Product Standards
Certified By
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
'qummary of Products
FL # Model, Humber or dame
2418.1 Dade Curb Mount Skylight
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +60/-60
Other:
2418.2 1 Dade Self Flashing Skylight
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +60/-60
Other:
Method 1 Option A
07/10/2015
07/16/2015
07/25/2015
Description
Polycarbonate (Glazed Aluminum Skylight
Certification Agency Certificate
Quality Assurance Contract (Expiration 10
12/31/2017
Installation Instructions
FL2418 :K9 z.
Verified By: National Accreditation & Manag
Created by Independent Third Party;
Evaluation Reports
lI
Created by Independent Third Party: Yes
Polycarbonate Glazed Aluminum Skylight
Certification Agency Certificate
F12413 iR9 C CAC.
Quality Assurance Contract Expiration C
12/31/2017
Installation Instructions
FL2418 i3u--t' DSF_1501.eef
Verified By: Natbna€ Accreditation & Manag
Created by Independent Third Party:
Evaluation Reports
61_2416 P9 AF i vaivatipr'��ca
Created by Independent Third Party Yes
'IBack! �Nextl
Contact :: 1940 North Monroe Street. Tallahassee FL 32359 Phone, 850-487-1824
The State of Florida Is an AA/FFO employer. Coovriaht 2007-2013 State of FloridiL:: Privacv Statement:: Accessibiliry Statement :: Rc
Under Florida law, email addresses are public records, it you do not want your e-mail address released in response to a public -records rec
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If youhave any questions, please contact 850.487.
Section 455.275(1), Florida Statutes, effective October 1, 21312, licensees licensed under Chapter 455, F.S. must provide the Department wi
they have one. The emails provided may be used for official communication with the 9Icensee. However email addresses are public record. I3
supply a personal.address, please provide the Department with an email address which can be made available to the public. To determine if yo
Chapter 455, F.S., please click here .
Product Approval Accepts:
Fog
)f 3 11/23/2015 2:14 PM
OF PRODUCT CER'TIFICA'TION
CERTIFICATION NO: N1009198 -R4
DATE: 12/30/2007
CERTIFICATION PROGRAM: Structural
COMPANY: Maxim
CODE: M-1256-1
REVISION DATE: 12/1812014
To verify that the "Notice of Product Certification" is valid, please visit to assure that
— the product is active and currently listed. This certification represents product conformity to the applicable
specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied
to the product to claim certification status. Please review and advise NAMI if any corrections are required to this
document.
COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
Maxim Industries, Inc.
1630 Terre Colony Court
Dallas, Texas 75212
SPECIFICATION
TAS 201/202/203-94
Series "Dade Self -Flashing"
Polycarbonate Glazed Aluminum Skylight
Configuration: O
Glazing: Exterior.Dome-0. 118 " Hyzod
Polycarbonate w/8" rise/Interior Dome -0.118"
Hyzod Polycarbonate w/4" rise
Overall: W-416" DLO: W-39"
H-8'6" H-719"
PRODUCT RATING
Design Pressure = +601-60 psf
Large Missile Impact. Rated
Product Tested By: Architectural Testing, Inc.
Report No: ATI -01-43381.01
Expiration Date: December 31. 2017
Administrator's Signature:
a
NATIONAL, ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes, VA 23072
Tel:. (804) 684-51241 Fax: (804) 684-5122
MAXIM INDUSTRIES, INC.
UADE SELF FLASKING SKYLIGHT
8" MAX. FROM 12" MAX.
CORNERS TYP. O.C. TYR
•
LLN I
W
�.� • I I •
I I
I I
• .I I •
I I
I 1
I l
I I W
I I J
I I o
k I �
E I =
• I I • ;;
I I
I I
I I
• I I e
I I
I I
I I
• I I •
I I
I I
J
I44.50" MAX. O.A. O.L.O. WIDTIi 11
54" MAX. O.A. FLANGE WIDTH
ELEVATION AND ANCHOR LAYOUT
z
d:
O
X
GENERAL NOTES:
1. This Product has been designed and tested to conform to the requlrements as determined in the
Florida Building Code Sth Edition (2014). -
2_ This product is designed for within and outside High Velociiy Hurricane Zone.
3. The Details and specifications shown herein represent product engineered and tested for water,
air, Impact, cyclic and uniform static air pressure testing in conformance with TAS 201, TAS 202,,
TAS 243.
4. When used in area& requiring wind bome debris protection this product complies with Sections
1609.1.2 and 1626 of the Florida Building Cade 5th Edition (2014) and does not require an impact
resistance covering,
5. Buliding structure must be designed by licensed professional engineer to carry the leads applied
from this product.
6. AD anchors to surrounding structure to be as listed and spaced as specified in these drawings, any
substitutions shall be approved by licensed professional Engineer.
7, Skylight Material is 6083-T6 Extruded Aluminum. Skylight Inner and Outer pome Material is
Polycarbonate. NOAH 12-0605.05.
8. Substrate material: Wood, mitdmum specific gravity of 0.42.
DESIGN PREStlRE RATING {PSF) IMPACT RATING
100.0 LARGE MISSILE IMPACT
tyi
G'.. U N
arc
�lWa
a
O
f a o
r E
_ 3 ¢ U
ti: t7 0 O O
� a
U-
CL
co to
.. .. U O Gi
DO
r" Omc o
?regia
ORE a-'00'0
No 49814 �p�'�'
STATS -iJF '� Z
0
taBtd1r941194q
THEODORE MMAN
PX
NOAMA
nwiLlls
DATE: 07110/15
DWG #: DSF1507
SCALE: N.T_&
SHEET: 1 of 2
I Minimum #12 X 1.25" fastener by others. Pre -punched instalition holes 4" from each comer, maximum 10.5" on center.. Minimum penetration = P.
2 -069'X 1.5" X 1.75",6063-T6 extruded aluminum retaining angle. Atuminum angle mitered and welded l@ fourcorneis. F"
3 52.5" X 100,375" UV Enhanced outer polycarbonate dome sr 8" height, on test sample (height varies per size) Q e.
4 52.5" X 100.375" UV Enhanced 'inner polycarbonate dome @4" height on test sample: (height varies per siza) z O
5 OSI PR256 urethane sealant. Located between aluminum retaining angle and outer dome & between inner dome and aluminum frame. 5E cV
6 Sealant tapo, 1" X .125" located between outer and inner domes. cn
7 6063-T6 extruded ahuninum frame. Aluminurn frame mitered and welded @ four corners, U- � X
8 912 X 1.75" fastener. Onefastener located equidistant from each corner. Pow fasteners per skyligh€ kr- O
9 # 10 X .375 18-8 stainless steel fastener. Located 4" from each comer, maximum I V an center. ud A U ¢�
l0 All units equal to or less than the total square footage or the test specimen, 36 square feet, will be accepted under this approval. w m
I I Minimum distance= 4" from angle lip to roof surface for shingles or BUR without insulation. For insulation and the roof add the height and insulation o W
thickness to the 4" minimum height.
c
w
Outer Polycarbonate Dome
Inner Polycarbonate Dome
#12 Stainless Steel Fastener with o
_ ® _
neoprene gasket, One fastener o 0
located equidustant from each
5 \ .corner. (Four fasteners per tom ^ as
O2 .060" Extruded Altuninum� Sealant O \,.skylight) o >
Retaining Am& Sealant Tape O a t+ er a
ns
—�'��-, Sealant Tapc�6 #10 X.375" stainless steel fastener @
4" from each corner, maximum 11" v
�--- Condensation Gutter �on center. C7 ` Q
060" Aluminum Frame O 4
en
Design Pressure: 60psf+/^
Minimum #12 X 1.5"
Test Pressure:-120psf & +1.80psf l l fastener. Installation
holes 3" from each
cormCr, maxinautn 12" lJ
3" Installation Flange on center. Minimum
/penetration =1 ".
m m
Self Flashing Model
Raof deck and framing by others. All ^
roof details shall comply with all `
sections of the Florida Building Code
and Florida Residential Code.
rrrese6rttEa'<4e
DATE: 07/10/15
DWG #: DSF1507
SCALE: N.T.S.
SHEET: 2 of 2
THFae6RE KAMAN, P.E.
No. 068!4
moans
LIGHT TRANSMISSION & GLAZING PERFORMANCE
Sheffield Makroion® po9ycorhono$e Dome
In uta e. Glass Performance
SHGC Winter U -Factor Fading Trans Light Trans
LoE366 (Low E Cubed)/Argon Gas:
�.
�1A7[•7� I�t���'t►71NU111[•aR•I:IIRM[WO�
0.43
66%
Bronze Tint/ Argon Gas:
Clear/Bronze (CB)
25%
60%
.90
.97
0.7 (ASHRAE)
Clear/Clear (CC)
74%
89%
90
.97
1.02 (ASHRAE)
Clear/Gray (CG)
43%
60%
.90
.97
0.7 (ASHRAE)
Bronze/Bronze (BB)
07%
36%
90
.97
0.49 (ASHRAE)
Clear/White (CW)
23%
40%
90
.97
0.71 (ASHRAE)
In uta e. Glass Performance
SHGC Winter U -Factor Fading Trans Light Trans
LoE366 (Low E Cubed)/Argon Gas:
0.27
0.24
0.43
66%
Bronze Tint/ Argon Gas:
0.63
0.31
0.52
61%
Gray Tint/ Argon Gas:
0.63
0.31
0.52
61%
FRAME FINISHES
Mill Finish
FEATURES
White Powdercoat
All insulated glass
provided by Maxim
includes argon gas.
All laminated impact
resistant glass is
manufactured with
DuPont— SentryGlas® Plus.
Bronze Anodized
Custom Color Powdercoat Custom Color Powdercoat
• Approvals include multiple Miami -Dade County Product Control NOAs; Florida Building Commission, FBC 2418-R3 (2010);
Texas Department of Insurance, TDI Report(s) SK -13 & SK -18
• All Maxim Skylights are tested and conform to AAMA/WDMA/CSA 101/I.S.2/A440-05 and all, or part, of the following
standards: ASTM E283, ASTM E330, ASTM E331, ASTM E547, ASTM El 886, Missile Level C as specified in ASTM
E1996-99, TAS 201-94, TAS 202-94, TAS 203-94, and ASTM E1300-02/03.
• All Maxim Skylights are third party certified to performance compliance and quality assurance by the National Accreditation
Management Institute (NAMI).
• Available in any size or shape up to 25 square feet, the largest impact resistant insulated glass skylight available.
• Insulated Glass for maximum energy efficiency available as Tempered, Laminated and DuPont— SentryGlas Plus Impact resistant.
• Unlimited configurations to meet any conditions.
• Optional curb assembly w/ prefinished white interior, solid wood curb and aluminum counterflashing.
• Insulated glass is tested to-200psf negative pressure for a +/-100psf Design Pressure.
• All Maxim insulated glass comes with XL Edge technology providing the lowest failure rate in the industry. Developed in part
from our suppliers 45 years of experience in manufacturing dual -seal silicone insulated glass.
• Mill Finish, Bronze Anodized, Clear Anodized or an unlimited number of powdercoat colors are also available.
• All insulated glass is covered by the manufacturer for 20 years
• Curb Mount available up to 36 square feet & Self Flashing up to 32 square feet in any size or shape.
• Polycarbonate domes are tested to-120psf & +180psf for a +/-60psf Design Pressure.
• Sheffield Plastics Makrolon° SL W enhanced polycarbonate outer domes for the ultimate in ultraviolet light protection.
• Virtually unbreakable polycarbonate domes meet large & small missile impact rating.
• Sealed double domes prevent moisture from occurring between the domes.
• Polycarbonate glazing meets UL 972 forced entry protection.
• Stainless steel fasteners eliminate rust and corrosion.
*Any type of cleaning performed on the roof, including removal of mold, mildew, fungus, or dirt, by pressure of any kind with water or chemical means will damage polycarbonate domes and
void any warranty. A detailed insulated glass warranty is available upon request. WARNING: SKYLIGHTS MAY NOT SUPPORT LIVE LOADS! While these skylights have passed testing for
large and small missile impact resistance, 1000 ft/lbs fall protection resistance and up to 200psf. positive pressure testing, they are not intended for any live load! Do not stand, sit, lean, or rest
on any part of the skylight.
Corporate Florida
1630 Terre Colony Court • Dallas, Texas 75212.6221 1818 7'i' Avenue North, Suite 2 • Lake Worth, Florida 33461
Toll Free 888-222-4898 • Fax 214-905-2024 Toll Free 800-367-8168 • Fax 561-588-9283
7/8/2016
Florida Building Code Online
.iF
�s3",-�`•@
.;'n sof _sus BCIS Home Log In h User Registration _ Hot Topics Submit Surcharge Stats & Facts Publications ; FBC Staff BCIS Site Map Links ; Search
Business,/,
f.:� Product Approval
PCofessid l USER Public User
y (ula
1
ra............... ...tu....... i:i�r„�a>.i:r„ Product Aoorcval Menu > Product or Aoolication Search > Aooliration List > Application Detail
FL # FL7006-R9
Application Type Revision
Code Version 2014
Application Status Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
IKO Industries, Ltd
40 Hansen Road South
Brampton, NON -US 1_6W 31-14
(708) 496-2800 Ext 200
rmetz001 @tam pabay. rr, co m
Robert Metz
rnietzOOI@tampabay.rr.com
Bob Metz
REMCO of Pinellas
456 Avila Circle NE
Saint Petersburg, FL 33703
(727) 776-5261
rmetz001@tampabay. rr.com
Don Shaw
IKO Industries LTD
120 Hay Rd.
Wilmington, DE 19808
(717) 579-6706
don.shaw@iko.com
Rooting
Asphalt Shingles
Certification Mark or Listing
FM Approvals - CER
Locke Bowden
Validation Checklist - Hardcopy Received
Standard
ASTM D3161 modified to 110 mph
ASTM D3462
ASTM D7158 Class H
ASTM E108
Year
2009
2009
2008
2007
https://www.flori dabui I di ng.orglprlpr_app_dtl .aspx?param=wGEVXQwtD gse7m YBd2b3K6m XtoZ LhN VX122N pl7DJ 1 E%3d 113
7/8/2016
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
FL #
7006.1
Florida Building Code Online
Method 1 Option A
06/28/2015
06/30/2015
07/06/2015
Model, Number or Name Description
Cambridge, Cambridge HD and CRC Laminated architectural fiberglass asphalt shingle
Biltmore AR manufactured at IKO's Kankakee, IL; Hawkesbury, Ont.;
Wilmington, DE; Sylacauga,AL and Toronto, Ont. plants
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other:
7006.2 Hip and Ridge 12 Cap fiberglass
shingles
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other:
7006.3 Leading Edge Plus Asphalt Shingle
Starter Strip
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other:
Certification Agency Certificate
FL7006 R9 C CAC FM Letter - ASTM d3161 letter - 4-15-
2015 .odf
FL7006 R9 C CAC FM Letter - ASTM d3462 letter - 5 6
15.odf
FL7006 R9 C CAC FM Letter - ASTM E 108 letter - 5 3
15 .ndf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL7006 R9 II IKO-133-02-01 Letter - Instalfation
Instructions for FBC FL7006.cdf
Verified By: Duc T Nguyen 65034
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
This is a 12" x 12" fiberglass asphalt shingle used to cover
the hip and/or ridge of an asphalt shingle roof system
manufactured in Toronto, Ont. and Brampton, Ontario
Certification Agency Certificate
FL7D06 R9 C CAC FM Letter - ASTM d3161 letter -
2015 .pdf
4-15-
FL7006 R9 C CAC FM Letter - ASTM d3462 letter - 5 6
1S.pdf
FL7006 R9 C CAC FM Letter - ASTM E 108 letter -
15 .pdf
III Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL7006 R9 II ilio and Ridae Cao Shina_ le Installation
Instructions.odf
FL7006 R9 II IKO-133-02-01 Letter - Installation
Instruct]ons for FBC FL7006.odf
Verified By: Duc T Nguyen OF 65034
Created by Independent Third Party: No
I Evaluation Reports
Created by Independent Third Party:
53
One piece fiberglass asphalt shingle used as a starter strip at
the bottom of a roof system manufactured in Brampton and
Hawkesbury, Ontario plants
Certification Agency Certificate
FL7006 R9 C CAC FM Letter - ASTM d3161 letter - 4-15-
� 2015 ,pdf
FL7006 R9 C CAC FM Letter ASTM d3462 fetter - 5 6
15. Pdf
FL7006 R9 C CAC FM Letter - ASTM E 108 letter - S 3
15 . odf
Quality Assurance Contract Expiration Date
12/31/2020 j
Installation Instructions
I
FL7006 R9 II IKO-133-02-01 Letter - Installation j
Instructions for FBC FL7006.Ddf II
FL7006 R9 II Roofina_-Products-Leadinc_-Fda_e-Pliis- ,
ADDlication-ENf ll.Ddf
Verified By: Duc T Nguyen PE 65034
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
7006.4 Marathon 25 AR CRC Su er lass 3 tab fiberglass asphalt shingle manufactured at IKO`s
https:!/www.fl ori dabui ldi ng.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgse7mYBd2b3K6mXtoZLhN\,XI22N pl7OJ 1 F°/a3d 2/3
7/8/2016
Contact Vs :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Convriaht 2007-2013 State of Florida. :: Privacv Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do rot send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, ES., please click here .
Product Approval Accepts:
sm ® RR
Credit Card
Safe
https:l/www.lloridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtD gse7mYBd2b3K6mXtoZLhNVX122N pl70J 1 E%3d 313
Florida Building Cade Online
M25AR
Brampton, Ontario, Hawkesbury Ont., Toronto, Ont.;
Sylacauga, AL and Kanakakee, IL plants
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL7006 R9 C CAC FM Letter - ASTM d316I letter - 4 -15 -
Approved for use outside HVHZ: Yes
2015 pdf
Impact Resistant: N/A
FL7006 R9 C CAC FM Letter - ASTM d3462 letter - 5 6
Design Pressure: N/A
15.Qf
Other:
FL7006 R9 C CAC FM Letter - ASTM E 108 letter - 5 3
15 .odf
Quality Assurance Contract Expiration Date
12/20/2020 s
Installation Instructions
FL7006 R9 If IKO-133-02-01 Letter - Installation
Instructions for FBC FL7006.odf
Verified By: Duc T Nguyen 65034
by Independent Third Party: No
jCreated
Evaluation Reports
Created by Independent Third Party:
Contact Vs :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Convriaht 2007-2013 State of Florida. :: Privacv Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do rot send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, ES., please click here .
Product Approval Accepts:
sm ® RR
Credit Card
Safe
https:l/www.lloridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtD gse7mYBd2b3K6mXtoZLhNVX122N pl70J 1 E%3d 313
FM Approvals,=z��<,=r�:�
1151 Boston -Providence Turnpike
P.O. Box 9102 Norwood, MA 02062 USA
T: 781 762 4300 F: 781 762 9375 www.fmapprovals.com
May 3, 2015
Mr. Donald Shaw
1K.0 Industries, Ltd.
40 Hansen Road South
Brampton, Ontario L6W 3H4
Canada
Customer ID: 1000000686
Subject: IKO Industries Ltd.'s FM Approved asphalt roof shingles
Dear Mr. Shaw,
This letter is being written following in regards to your recent inquire regarding verification of the ASTM
D3161 testing of IKO Industries Ltd's asphalt roof shingles. 1KO's shingles that are FM Approved have
been tested in accordance with ASTM D3161 (reports 3040947 and 3038510).
FM Approved products:
IKO`Industries Ltd:` Crowne Slate, Cambridge, Hip & Ridge 12, .Marathon 25 AR, Marathon
Ultra AR, Cambridge IR, Leading Edge Plus, Cambridge HD, Marathon
25, Hip & Ridge Plus, Dynasty with ArmourZone
unroof Corporation, Inc: Biltmore, Hip & Ridge 12 (CRC), Superglass 25 M AR, Superglass
Ultra AR, (CRC) Hip & Ridge Plus
Please be advised that shingles noted above tested to previous versions of ASTM D3161 continue
to meet the test criteria of the current version of ASTM D3161.
If you have any questions please do not hesitate to contact me.
Very truly yours,
David L. Alves
Senior Engineer - Materials Group
FM Approvals
1151 Boston -Providence Turnpike
Norwood, MA 02062
T: 781 255 4856
E: day-°id.alvesrcUfnlat)nrovals.com
Ex C E O
Phillip J. Smith
Principal Engineer - AVP
FM Approvals
C f US
APPRItVEII
K3
CONSTRUCTION MATERIALS
TECHNOLOGIES
March 30, 2015
IKO Industries, Ltd
120 Hay Rd.
Wilmington, DE 19809
Re: FBC FL7006
Sir(s),
PRI Construction Materials Technologies has completed a technical review and attached sealed shingle
instructions in compliance the 2014 Florida Building Code.
This review was completed based on the receipt of following evidence from IKO Industries, Ltd:
1) IKO Shingle Application Instructions — 3 -Tab Shingles
(EN-3Tab_Appins_8AGXEFS-2012-11_reformatted 2013-02-rev07/13-Florida)
2) IKO Laminated Shingles Application Instructions
(EN-Laminated_Appins_8TTEFS-2012-04_reformatted 2013-02-rev07/13-Florida)
3) IKO Hip and Ridge 12 Application Instructions
(EN-HipandRidge 12_3HRTri-2013-08_reformatted 2013-08)
4) IKO Leading Edge Plus Shingle Application Instructions
(EN-3LEP-Tri-2012-06—reformatted 2013-03)
5) ASTM D3161 Test Report (FM Approvals Project No. 3040947)
The attached instructions should be used in conjunction with the published manufacturer's application
instructions and applicable code. In the event the instructions conflict, these instructions shall govern.
Statement of Independence: PRI Construction Materials Technologies and/or Duc T. Nguyen, FL P.E. do not
have nor plan to acquire a financial interest in any company manufacturing or distributing products for which
the test reports are issued.
Signed:
Brad Grryboxsk�i
Managing Director
Date:
April 30, 2015
Signed:
Duc L. N u en '
Florida Re-gitsTered Professional Engnebr
P.E. Number: 65034
Date:
Attachments: A) IKO Shingle Application Instructions - 3 -Tab
8) IKO Laminated Shingles Application Instructions
C) IKO Hip and Ridge 12 Application Instructions
D) IKO Leading Edge Plus Application instructions
IKO-133-02-01
April 30, 2015
PRI Construction WOWS Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813 21-5946 a -mail: maledalstesting@pricmt.com WebSite, http:flwvvw.pdcmt.com
li
Installation Instructions for
Asphalt Shingles
Page 2 of 5
I1<4 Shingle Application Instructions — 3 -Tab Shingles
(ASTM D3161, Class F — IKO Marathon 25 AR and CRC Superglass M25AR)
NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
CONFLICT, THESE INSTRUCTIONS WILL GOVERN.
ROOF DECK: Solidly sheathed and fastened deck conforming to 2014 FBC.
UNDERLAYMENT: Applied in accordance with building code requirements. For areas where the roof slope is
less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code
requirements, the first sheet overlapping the eave protection by 19", followed by full 36" widths overlapping
each preceding course by 19" or other Approved underlayments in accordance with the qualified application
instructions. For areas where the root' slope is 4" per foot or greater, cover the deck with one ply of
underlayment laid parallel to the eaves, with 2" horizontal laps and 4" end laps. Apply metal drip edges on top
of any underlay along rake edges and directly to the deck along eaves in accordance with building code
requirements.
NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 318" diameter heads, long
enough to penetrate through plywood or 314" into boards. Use 4 nails per shingle placed 6-1/8" above the butt
edge, approx. 1" and 13" from each end and 112" above each cutout. Drive nails straight so that nail head is
flush with, but not cutting into shingle surface.
NAILING ON STEEP SLOPES: For steep slopes of 21" per foot (60°) or more, use 6 nails per shingle placed
as shown below. Ensure that no nail is within 2" of a joint/cutout of the underlying shingle. Seal down each
shingle at time of application with three 1" diameter (approx. size and thickness of a quarter) spots of asphalt
plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle.
Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles
should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the
heat of direct sunlight.
EXPOSURE: Installed shingles shall have a maximum average exposure of 5-518".
STEEP SLOPES
_� ; a — ✓;� SEALING STRIP
- -- NAIt_9--
DO NOT NAIL INTO OR ABOVE THE SEALING STRIP
PRI Construction Materials Technologies, 1 6412 Badger Drive Tampa, FL 33610 Tel: 813.621-5777 Fax: 813.621-5840 a-mall:materialstesting@pricmt.com WebSite', http:llwww.pdcmt.com
iK0
Installation Instructions for
Asphalt Shingles
Page 3 of 5
IKO Laminated Shingles Application Instructions
(ASTM D3161, Class F — Cambridge, Cambridge HD, and CRC Biltmore AR)
NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
CONFLICT, THESE INSTRUCTIONS WILL GOVERN.
ROOF DECK: Solidly sheathed and fastened deck conforming to 2014 FBC.
UNDERLAYMENT: Applied in accordance with building code requirements. For areas where the roof slope is
less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code
requirements, the first sheet overlapping the eave protection by 19", followed by full 36" widths overlapping
each preceding course by 19" or other Approved underlayments in accordance with the qualified application
instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of
underiayment laid parallel to the eaves, with 2" horizontal laps and 4" end laps. Apply metal drip edges on top
of any underlay along rake edges and directly to the deck along eaves in accordance with building code
requirements.
NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 318" diameter heads, long
enough to penetrate through plywood or 314" into boards. Use 4 nails per shingle placed in the nail line 7-318"
below the top edge, approx. 1" and 13" in from each end. Drive nails straight so that nail head is flush with,
but not cutting into shingle surface.
NAILING ON STEEP SLOPES: For steep slopes of 21" per foot (60°) or more, use 6 nails per shingle placed
as shown below. Ensure that no nail is within 2" of a joint/cutout of the underlying shingle. Seal down each
shingle at time of application with three 1" diameter (approx. size and thickness of a quarter) spots of asphalt
plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle.
Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles
should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the
heat of direct sunlight.
EXPOSURE: Installed shingles shall have a maximum average exposure of 5-718".
NAILING - STEEP SLOPES APPLICATION
1158 six nails as st own.
7 3/i3"
r i
♦ r _ - — - NAILLINE
NAILS e NjENIT �r
PROPER APPLICATM RFOUIRES THAT THE NAILS PENETRATE BOTH THE OVERLAY AND UNDERLAY PORTIONS OFTHE SHINGLE
PRI Construction Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5840 e-mail: materiaistestingopricmt.com WebSite: httpalwm.pricmt.cem
Ii
Installation Instructions for
Asphalt Shingles
Page 4 of 5
IKO Hip and Ridge 12 Application Instructions
(ASTM D3161, Class F -- IKO Hip and Ridge 12)
NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
CONFLICT, THESE INSTRUCTIONS WILL GOVERN.
Cut hip and ridge shingles into thirds, using the perforation marks as a cutting guide. These shingles are
designed for a 5 118" (130 mm) exposure. (For a neater appearance, the top of each side of each piece has
been factory trimmed on a 1" (25 mm) taper (see drawing). Bend each piece over the hip or ridge, and nail 5
518" (143 mm) above the butt edge 1" (25 mm) in from each edge, exposing each piece 5 118" (130 mm).
Apply hip pieces starting at the lower end of the hip, working up toward the ridge. On hip roofs, apply ridge
pieces starting at each end, meeting in the middle. On gable roofs, apply ridge pieces starting at the end
opposite to the prevailing wind direction and continue to the other end. Note: To obtain a three-dimensional
effect, (which is recommended, but not required), apply hip and ridge shingles double thickness bystacking 2
pieces on top of one another, the lower piece extending about 314" (19 mm) further than the top piece (see
diagram). The final shingle should be set in cement, and the exposed nail heads of the final shingle should be
covered with cement. Prior to application in cold weather, storing the shingles in a heated area will allow for
easier bending.
NOTE: SHINGLES MUST BE APPLIED PROPERLY. THEYARE DESIGNED FOR USE AS HIP AND RIDGE
SHINGLES ONLY, AND SHOULD NOT BE USED FOR ANY OTHER APPLICATIONS. WE ASSUME NO
RESPONSIBILITY FOR LEAKS OR DEFECTS RESULTING FROM POOR APPLICATION OR FAILURE TO
PROPERLY PREPARE THE SURFACE TO BE ROOFED OVER, OR FAILURE TO PROVIDE PROPER
VENTILATION IN ACCORDANCE WITH MINIMUM PROPERTY STANDARDS REQUIREMENTS. REVIEW
ALL APPLICABLE BUILDING CODES, MINIMUM PROPERTY STANDARDS, AND REQUIREMENTS PRIOR
TO APPLYING THESE SHINGLES USING THESE APPLICATION INSTRUCTIONS.
1
TAPER'LTF
PRI Construction Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 336117 Tel: 613-621.5777 Fax: 613-621-5840 e-mail: materialstesting@pricmt.com Website: http llwww.pricmt.com
IKO
Installation Instructions for
Asphalt Shingles
Page 5 of 5
IKO Leading Edge Plus Application Instructions
(ASTM D3161, Class F — IKO Leading Edge Plus)
NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
CONFLICT, THESE INSTRUCTIONS WILL GOVERN.
1. Apply any underlayment, eave protection, valley flashings, or drip edges to roof deck as required.
2. Each 39 318" x 13 114" (1000 mm x 336 mm) IKO Leading Edge Plus strip is perforated lengthwise for
separation into two (2) shingles. Take one KID Leading Edge Plus strip and fold flat at perforation to
separate.
3. Take one of the separated shingles 39 318" x 6 5/8" (1000 mm x 168 mm) and remove approximately
20"(500 mm). Install this shingle on the lower left corner of the roof deck, granule side up, with the
factory installed sealant adjacent to the eaves. The shingle should overhang the rake edge and eaves
by a nominal 114" (6 mm) minimum. Fasten the shingle to the roof deck with nails located 3" to 4"(75
mm to 100 mm) from the eave edge and 1" (25 mm) in from each end.
4. Take the leftover 20" (500 mm) piece shingle. Rotate the piece and align it vertically up the rake edge
with the factory installed sealant adjacent to the outer edge of the roof. The shingle should overhang
the rake edge by a nominal 114" (6 mm) minimum. Fasten the shingle to the roof deck with fasteners
located 3" to 4" (75 mm to 100 mm) from the rake edge and 1" (25 mm) in from each end.
5. Repeat Steps 3 —4 for the right lower corner of the roof deck.
NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least
318" (9 mm) diameter heads, long enough to penetrate through plywood or 314" (20
mm) into boards. Use 4 nails per shingle placed 3" to 4" (75 mm to 100 mm) from
the eave edge and approximately 1" and 13" (25 mm and 330 mm) in from each end.
6. Apply full-length IKO Leading Edge Plus shingles to the remaining eave edges of the roof deck. Install
the shingles granule side up with the factory applied sealant adjacent to the eaves. The shingles
should overhang the rake edge and eaves by a nominal 114" (6 mm) minimum. Fasten the shingles to
the roof deck with nails located 3" to 4" (75 mm to 100 mm) from the eave edge, 4 nails per shingle.
7. Apply roof shingles as per the instructions printed on each product's package. Make certain the first
course of field shingle lies flush with the edges of the fastened IKO Leading Edge Plus. In this way,
the sealant on the IKO Leading Edge Plus shingles will adhere to the first -course field shingles and
help keep them from lifting in high winds.
PRI Construction Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813.6215777 Fax: 813-621-5848 e-mail: matarialstest'ng@pricmt.com Web5its, http:llwww.pricmt.com