Loading...
HomeMy WebLinkAboutpermit application .� , Florida Departmentq BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publications I FBC Staff I BCIS Site Map I Links I Search ' Busine% a Professi6nalProduct Approval USER:Public User Regulation Product Approval Menu>Product or Application Search>Application Ll st>Application Detail FL# FL5259-R24 Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived L_ Product Manufacturer POLYGLASS USA Address/Phone/Email 150 Lyon Drive Fernley, NV 89408 (570)384-1230 Ext 242 jakins@polyglass.com Authorized Signature James Akins jakins@polyglass.com Technical Representative Steve Wadding 9 Address/Phone/Email 150 Lyon Drive Fernley,NV 98408 (602)363-7139 stevew@polyglass.com Quality Assurance Representative James Akins Address/Phone/Email 555 Oakridge Road Humboldt Industrial Pkwy Hazleton,PA 18201 (800)894-4563 jakins@polyglass.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ✓- Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 07/01/2017 Validated By John W. Knezevich, PE i✓! Validation Checklist-Hardcopy Received Certificate of Independence FL5259 R24 COI 2015 01 COI Nieminen.odf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2009 ASTM D226 2006 ASTM D6164 2005 ASTM D6222 2008 ASTM G154 2006 ASTM G155 2005 FM 4474 2004 FRSA/TRI April.2012 2012 TAS 103 1995 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 07/22/2015 Date Validated 08/07/2015 Date Pending FBC Approval 08/15/2015 Date Approved 10/16/2015 Summary of Products FL# Model,Number or Name Description 5259.1 Polyglass Roof Roofing underlayments Underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL5259 R24 II 2015 07 FINAL ER POLYGLASS UNDERLAYMENTS FL5259- Approved for use outside HVHZ:Yes R24.Pd Impact Resistant:N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party:Yes Other: 1.)The design pressure in this Evaluation Reports application relates to one particular FL5259 R24 AE 2015 07 FINAL ER POLYGLASS UNDERLAYMENTS FL5259- underlayment system(over concrete deck)for R24.pdf use under foam-on tile systems(where the Created by Independent Third Party:Yes underlayment forms part of the load-path). Refer to ER Section 5.6.4 for other systems, other deck types and associated maximum design pressures.2.) Refer to ER Section 5 for other limits of use. Back Next Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here. Product Approval Accepts: W-711 wt_O securitvtu Titres EXTERIOR RESEARCH&DESIGN,I.I.C. Certificate of Authorization#9503 T'��' Tp�'INITYJERD 353 CHRISTIAN STREET, UNIT#13 OXFORD,CT 06478 t PHONE:(203) 262-9245 FAX: (203)262-9243 EVALUATION REPORT Polyglass USA,Inc. Evaluation Report P12060.02.09-1120 150 Lyon Drive FL5259-R24 Fernley, NV 98408 Date of Issuance:02/24/2009 Revision 20:07/22/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof-Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 12. Prepared by: `,�peitnernl,,� * _ The facsimile seal appearing was authorized by Robert Nieminen, P.E.on 07/22/2015. This does not serve as an electronically Robert J.M.Nieminen,P.E. I,�9'�'-� �.r�; signed document. Signed,sealed hardcopies have been Florida Registration No.59166,Florida DCA ANE1983 '? Vii;;,; .. ."4 transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinityJERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing,products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. i► TRINITY I ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Uplift FM 4474 2004 1504.6 Accelerated Weathering ASTM G154 2006 1504.6 Accelerated Weathering ASTM G155 2005 1507.2.3,1507.3.3,1507.5.3,1507.7.3, Physical Properties ASTM D226 2006 1507.8.3,1507.9.3 1507.2.4,1507.2.9.2,1507.5.3,1507.7.3 Physical Properties ASTM D1970 2009 1507.11.2 Physical Properties ASTM D6164 2005 1507.11.2 Physical Properties ASTM D6222 2008 1507.3.3 Installation Practice FRSA/TRI April 2012 2012 1523.6.5.2.1 Physical Properties TAS 103 1995 3. REFERENCES: Rafty Examination Reference Date FM Approvals(TST 1867) Wind Uplift 3004091 01/12/2000 PRI(TST 5878) Physical Properties PRIO1111 04/08/2002 PRI(TST 5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI(TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI(TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI(TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI(TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI(TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI(TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI(TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI(TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI(TST 5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI(TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI(TST 5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI(TST 5878) Physical Properties PUSA-088-02-01 07/29/2009 MTI(TST 2508) Physical Properties JX20H7A 04/01/2008 MTI(TST 2508) Physical Properties RX14E8A 01/29/2009 ERD(TST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD(TST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD(TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD(TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD(TST 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD(TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD(TST 6049) Physical Properties P13450.08.09 08/13/2009 ERD(TST 6049) Wind Uplift P30540.11.09-R1 11/30/2009 ERD(TST 6049) Physical Properties P11030.11.09-1 11/30/2009 ERD(TST 6049) Wind Uplift P11030.11.09-2 11/30/2009 ERD(TST 6049) Physical Properties P11030.11.09-3 11/30/2009 ERD(TST 6049) Physical Properties P33360.06.10 06/25/2010 ERD(TST 6049) Physical Properties P33370.03.11 03/02/2011 Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-1120 Certificate of Authorization x{9503 FL5259-1124 Revision 20:07/22/2015 Page 2 of 12 r �1 TRINrry I ERD Enti Examination Reference Date ERD(TST 6049) Physical Properties P33370.04.11 04/26/2011 ERD(TST 6049) Physical Properties P37300.10.11 10/19/2011 ERD(TST 6049) Physical Properties P40390.08.12-1 08/06/2012 ERD(TST 6049) Physical Properties P40390.08.12-2 08/07/2012 ERD(TST 6049) Physical Properties C41420.09.12-3 09/11/2012 ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013 ERD(TST 6049) Physical Properties P45370.04.13 04/26/2013 ERD(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013 ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013 ERD(TST 6049) Wind Uplift 1311751.05.03-R1 11/26/2013 ERD(TST 6049) Wind Uplift 1311781.11.03-R1 11/26/2013 ERD(TST 6049) Physical Properties P45270.05.14 05/12/2014 ERD(TST 6049) Physical Properties 6020.07.14-1 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-2 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-3 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-4 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-5 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-6 09/08/2014 ERD(TST 6049) Physical Properties P46520.10.14 10/03/2014 ERD(TST 6049) Physical Properties P44360.10.14 10/07/2014 ERD(TST 6049) Physical Properties P43290.10.14 10/17/2014 ERD(TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015 ERD(TST 6049) Physical Properties P40390.04.15 04/03/2015 ERD(TST 6049) Wind Uplift PLYG-SC8905.15 07/22/2015 ICC-ES(EVL 2396) IBC Compliance ESR-1697 11/01/2014 Miami-Dade(CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015 Polyglass USA Manufacturing Affidavit Products Current 02/18/2009 Polyglass USA P/L Affidavit Mule-Hide Cross Ltg 03/01/2008 Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011 UL,LLC.(QUA9625) Quality Control Service Confirmation,R14571 Exp.08/08/2015 UL,LLC.(QUA9625) Quality Control Service Confirmation,MTS PLUS Exp.07/01/2017 4. PRODUCT DESCRIPTION: 4.1 Mechanically Fastened Underlayments: 4.1.1 Elastobase is a fiberglass reinforced,SBS modified bitumen base sheet. 4.1.2 Elastobase P is a polyester-reinforced,SBS modified bitumen base sheet. 4.2 Self-Adhering Underlayments: 4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced, surfaced with polyolefinic film surface;meets ASTM D1970 and TAS 103. 4.2.2 Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with poly-film surface;meets TAS 103. 4.2.3 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced, with an aggregate surface;meets ASTM D1970... 4.2.4 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with a polyester fabric surface;meets ASTM D1970 and TAS 103. 4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane,glass-fiber/polyester reinforced, with a granular surface;meets ASTM D1970 and TAS 103. 4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester fabric surface;meets ASTM D1970 and TAS 103. Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-1120 Certificate of Authorization 119503 F1.5259-1124 Revision 20:07/22/2015 Page 3 of 12 •r F)o -f RINrry ERD 4.2.7 Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (FR) are polyester reinforced,APP modified bitumen cap sheets;meet ASTM D6222. 4.2.8 Polystick Dual Pro' is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polyester fabric surface;meets ASTM D1970. 4.2.9 Polystick Tile Pro' is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polyester fabric surface;meets ASTM D1970 and TAS 103. 4.3 Mechanically Fastened and/or Bonded Underlayments: 4.3.1 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced,SBS modified bitumen cap sheets;meet ASTM D6164. 4.3.2 Polyflex G and Polyflex G FR are polyester reinforced,APP modified bitumen cap sheets;meet ASTM D6222. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed,a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS Underlayment Asphalt Shingles Nail-On Tile Foam-On Tile Metal Wood Shakes& Slate Shingles Yes Yes Elastobase Yes (base layer in 2-ply (base layer In 2-ply Yes Yes Yes system) system) Yes Yes Elastobase P Yes (base layer in 2-ply (base layer in 2-ply Yes Yes Yes system) system) Polystick MTS Yes Yes No Yes Yes Yes Polystick MTS PLUS Yes Yes No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes Polystick TU P Yes Yes Yes See 5.5.1 No Yes Yes Polystick TU Plus Yes Yes Yes Yes Y See 5.5.1 es Yes Polystick TU Max No Yes Yes Yes No No See 5.5.1 Polystick Dual Pro Yes Yes No Yes Yes Yes Polystick Tile Pro Yes Yes Yes Yes Yes Yes See 5.5.1 Elastoflex S6 G Yes Yes Yes No Yes Yes See 5.5.1 Elastoflex S6 G FR Yes Yes No No Yes Yes Polyflex G Yes Yes Yes No Yes Yes See 5.5.1 Polyflex G FR Yes Yes No No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes No Yes Yes See 5.5.1 Mule-Hide SA-APP Cap Sheet Yes Yes Yes No Yes Yes or SA-APP Cap Sheet(FR) See 5.5.1 Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-R20 Certificate of Authorization#9503 FL5259-1124 Revision 20:07/22/2015 Page 4 of 12 r \ TRlf�ll-Y I ERD 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 Elastobase,Elastobase P or Mule-Hide Nail Base: 6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226,Type II underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 Non-Tile Applications: Reference is made to the current edition of the NRCA Steep-slope Roofing Manual and ARMA recommendations for installing shingle underlayments and flashings Elastobase, Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR),Dual Pro or Tile Pro,self-adhered,Elastoflex S6 G or S6 G FR in hot asphalt or Polyflex G or G FR,torch applied. 6.3.3 Tile Applications: Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein,using the instructions noted above as a guideline. 6.4 Polystick MTS,MTS PLUS,IR-Xe,TU P,TU Plus,TU Max Polyflex SAP or SAP FR,Mule-Hide SA-APP Cap Sheet or SA- APP Cap Sheet(FR),Dual Pro or Tile Pro: 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 Direct-to-Deck with Mechanically Fastened Roof Covers: All self-adhering materials,with the exception of Polystick TU Plus,Polyflex SAP or SAP FR and Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)should be back-nailed in selvage edge seam in accordance with Polyglass/Mule-Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring-shank type with a minimum 1-inch diameter metal disk or Simplex-type metal cap nail,at a minimum rate of 12"o.c. Polystick TU Plus should be back-nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back-nailed All seal-lap seams (selvage laps) must be f,, firmly rolled with a minimum 28 Ib. hand '` s €r roller to ensure full contact and adhesion. { { For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). tz View of Ovelap Seam of Dual Pro and Tile Pro All over-fabric and over-granule end-laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap. Polystick TU Plus,Dual Pro and Tile Pro may not be used in any exposed application such as crickets,exposed valleys, or exposed roof to wall details Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-R20 Certificate o Authorization#9503 FL5259-R24 Revision 20:07/22/2015 Page 10 of 12 . �r(T , rI n0(Ida D°palt'(IiEntq BCIS Home Log In User Registration HotTopics Submit Surcharge j Stats&Facts Publications FBC Staff BCIS Site Map I Links Search BusinesV r t0plProfessibn/al 't JUSER PubrOV01 Public Regulation Product Approval Menu>Product or Application Search>Application List>Application Detail D' FL# FL10674-Rl l a� Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo,OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert J.M. Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/20/2017 Validated By John W.Knezevich,PE si Validation Checklist-Hardcopy Received Certificate of Independence FL10674 Rll COI 2015 01 COI Nieminen.odf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/15/2015 Date Validated 10/19/2015 Date Pending FBC Approval 10/20/2015 Date Approved 12/15/2015 Summary of Products FL# Model,Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge shingles Shingles and Starters Limits of Use Installation Instructions Approved for use in HVHZ: No FL10674 R11 II 2015 10 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674-Rli.odf Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party:Yes Other: Refer to ER,Section 5. Evaluation Reports FL10674 R11 AE 2015 10 FINAL ER OC ASPHALT SHINGLES FL10674-Rll.Ddf Created by Independent Third Party: Yes Back Next Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here. Product Approval Accepts: ®Ek M SCCUCIh'St1:71tIC EXTERIOR RESEARCH&DESIGN, LLC. z;•�� Certificate of Authorization 119503 STREETUNIT#13 ASgq TRINITY;ER® 353 CHRISTIAN OXFORD,,CT 06478 C PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-116 One Owens Corning Parkway FL10674-R11 Toledo,OH 43659 Date of Issuance:02/06/2012 Revision 6: 10/15/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: ,Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: Robert J.M.Nieminen P.E. +ry6'S'•., ��,` The facsimile seal appearing was authorized by Robert Nieminen, (.i,�!- al ',`,> P.E.on 10/15/2015.This does not serve as an electronically signed Florida Registration No.59166,Florida DCA ANE1983tJ�'""`t'"ss��. document.Signed,sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. r' TRINITY I ER® I ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,11905:2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: kniint Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme®are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire®are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire'are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration®, Tru Definition® Duration®, Duration m Premiurt I f Cool, TruDefin'ition® Duration Designer Color' Collection,Tru Definition®Oakridge,Oakridge and WeatherGuard®HP are fiberglass reinforced,laminated asphalt roof shingles. 4.2 Berkshire® Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard® HP Hip & Ridge Shingles, Pro Edge Hip& Ridge Shingles and DuraRidge'"' Hip& Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R6 Certificate of Authorization#9503 FL10674-R11 Revision 6:10/15/2015 Page 2 of 7 \jTRINITY ERD 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for us in all wind zones up to Vasd=150 mph (Vult=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F, indicating the shingles are acceptable for us in all wind zones up to Vasd= 150 mph (Vnit= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.21 with the following exceptions: ➢ Berkshire shingles require minimum five(5)nails per shingle. ➢ WeatherGuard®HP shingles require minimum six(6)nails per shingle. ➢ DevonshireTM'shingles require minimum six(6) nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Felt underlayment Deck FeltundetlaymentDeck Self-adhered l C WeatherLack'.d Self-adhered undedayment WeatherLocP underlayment Drip Drip edge Dag Drip edge .• ge Naps located Nails located 2"-3•from eave 27-3"from eave Install first Self-sealing adhesive Sdfaeagng adhesive Starter Strip positioned along eave fnstallfirststarterstrip Pin positioned along eave shingle with \ with 61 removed 6"removed r a Starter strip Pkts overhangs eaves and rakes 1/41-3/4° Starter Strip shingle overhangs eaves and rakes/�"-/i' P 9 Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R6 Certificate of Authorization t/9503 FL10674-R11 Revision 6:10/15/2015 Page 3 of 7 TRINI` Y1ERD 6.2.6 Minimum Nailing—Classic®&Supreme: Normal Mansard or Area para Normal Mansard or Area pare Wind Areas High Wind desvanes y WindAreas High Wind desvarres y Area pare vientos normales Areas vientos fuertes Areapara vientos normales Areas vientos fuertes 127 5"Exposure 5 5/8"Exposure Exposition Exposition 6.2.7 Minimum Nailing—Berkshire°: Seabnt strip Sealant strip to Ufa de selfador !a Via de sellador. 9 vt' 9 Y{' eye } „,EIV 8Yt' 8 Yf 8 YT t t� ,"J 1. 1"J Y 1 2" Asphalt rooting cement Cemento Je fecho de astalto 6.2.8 Minimum Nailing—Devonshire TM: 7 47 Nails �`i 13': 13-W Nails Ten 1"Spots of Asphalt Roof Cement Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-116 Certificate of Authorization#9503 FU0674-R11 Revision 6:10/15/2015 Page 4 of 7 f TRINrry j ER® 6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition Duration®Designer Color Collection: 4 Nail pattern. 6 Nail �tenbeuvvee Su Esquema de.4 clavos Pattern aieaanatop of cut out., -- Esquema: drbrsarrb oiled Mes: Sure,Waiiu fastening ama width de 6davosamtasrodasemre et Area dedauosSuieNaOo • • • dreaSweNapybpate -SureNail®- \- :SurePlalta fastenin h>lenTAA : areawid�h. areawitlt0 12" 12-.. Araada - .T' �.,� \T -Area de dams SuteNa'J� F -1Z' -12'- �. Sureliai(a IInTTy� � -• - • _� Sw ExposuieNails 5W rxposure 5:�Ogg.deexposicidn Gados 65.4pu10:deexposici6n 5W'ExposureNails 5V'Exposure 51hpulg.doerpasici6ir: Davos Wpufg.doexposicl-An 6.2.10 MinimumNailing-TruDefinition®Oakridge®,,Oakridge®. 4 Nail Pattern° 6 Nail•Pattern Esgbema;eou 4'alavos , Esquema eon 6 davos r 5518 Eliposure Nails. 5 51 r Exposure5518-Ex Na1s fxposru6nde55/Spuf9 Ctavos t ExposieFonde55/8pulg. Pum Clavos .5518 Exposum Erposicldu de 5b/8pulg. Firposierbn We 55/8pulg. 6.2.11 Minimum Nailing—WeatherGuard® HP: �■ S Bingle 61Cb-VIMw s s• iie4rt�7F �t Ndl lir: Cr<wi��u fati�de�h 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire®Hip and Ridge Shingles,High Ridge, Hip&Ridge with Sealant,WeatherGuard®HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Installation of DuraRidgeTm Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using two(2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R6 Certificate of Authorization 119503 FL10674-R11 Revision 6:10/15/2015 Page 5 of 7 T INI IERD I 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig.1 4 Fig.2 F— PieOallingWrid- ToPVieN. Sitlelfieuu Direction A - - - Naas+ Nails- Q 11 r I To Laminated 4" Place f 1 • "i I 1. I 1 I. 6.3.4 Minimum Nailing-Hip&Ridge with Sealant: em Eig.�2 Huh W>nd Fal Wi>tg Ratttten . rim°shingle iiscar Excress Se�ailalnt ----� +► ' 1 Strip . 72,x, Fas+tening.. $,'Exposure Distanoe 7V 6.3.5 Minimum Nailing—WeatherGuard® HP Hip and Ridge: Fig.C HIP.;&Ridge;:Shingle Fastening, Fig.A Y 4 ToppkVt Prevailing Wind �– Direction A A- Nails 44. NaNs Nails A I I 1' A I I I I • A I I I I 71 I I 1 i s'—>•I Exposure S' EYposure- Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R6 Certificate of Authorization 119503 FL10674-R11 Revision 6:10/15/2015 Page 6 of 7 TRINITY I ERD 6.3.6 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard 11°— . Wind Direction Sealant Strip Pattern g 6°Exposure ,�� I.� I«I I•'1' 12° 1 Sealant f Fasten 711° 7°�= 6°Exposure Cover Exposed 1 1 Fasteners with Roof Cement 6.3.7 Minimum Nailing—DuraRidgeTm Hip&Ridge Shingles: Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. IProvaiing Wind Diracdon To en plan Diroaion dornimnto divoac Diroc&ndolviamoprodomimnco II" Vistasuperlor 1-IH S /NO r OenM Condng SurolJaH' Ckro Clow I I I a�oc I I I F I I I I a_I�^' U l a I ® 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(414)248-6409; karen.buchmann@ul.com - END OF EVALUATION REPORT- Exterior EPORT-Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-116 Certificate ofAutharization 119503 FL10674-R11 Revision 6:10/15/2015 Page 7 of 7