HomeMy WebLinkAboutWind Load Calculation Property Information Building Information Owner: Pokorny Wind Zone: 160 MPH. Address: 120 Beach Ave Exposure Category: B PortSt Lucie,Fl 34952 Minimum Building Dimension: 30 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 110 49 7 29.7 -32.4 ........... ___.... ................................ ........ ......... .. ._. ..._. ......... ................. ....................... ....... ....................... 2 Int 36 80 7 31.0 -33.8 __. .. .... ....... . .... .................. ......... .................................................. ............ . _ _._ . ........ ...... 3 Int 110 63 7 29.2 31.9 ..... ........ ......... ......... _........_.. ............ ._..... . ... ..... ...... ....._.. _ ...._._... 4 End 73 38 7 31.1 -40.7 ......._. . ..... ..._... . ........ ......... .............. ......... ..... ......................... ... ............................................ ...._... ............ ......... 5 End 73 38 7 31.1 -40.7 ......... . ......... _... _.__. . ........ ......................_ ......... ... ........ ............... 6 Int 73 38 7 31.1 33.8 ............. ..............-1-1 ........................... ................................._. . . ........ . _.__._ .......... ........... .................. .... _......._._ __._ 7 End 53 38 7 31.8 42.1 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.5th Edition(2014)Florida Building Code. Page 1 of I