Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Wind Load Calculation
RECEI�'�D �a0`d 10 7.0.6 FILEov-q eater tore HURRICANE SHUTTERS, IN PANELS •ACCORDIONS • BAHAMAS COLONIALS ROLL UPS . Property Information Building Information _j Owner: JAMES WOHLNER Wind Zone: 170 MPH. Address: 1680 Buttonbush Circle Exposure Category: B Palm City,F1349990 Minimum Building Dimension: 6 ft. Mean Roof Height: 15 ft. Risk Category: 1I F- Design Pressure Calculations Opening Location Device Devices Device Mas Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) L Pressure(psf) 1 Int 73-75 109 7 27.7 _ -30.3 2- Int 102 - 141 7 _._ _... 26.5 -29.1 3 End 76 80 7 28.2 -35.9 - --- -- - - ---- - - - --- - - - ----------- 4 ------- -- 4 Int 76 80 7 28.2 -30.9 ...... _.....- -..... _._.... -- ---- 5 Int 160.5 111 7 26.1 -28.7 ......_.. - - -- .. - - - - - -- - ------ -- -- --. _......._ - - - - - 6 End 56.5 95 7 28.5 36.4 7 End 53.25 50 7 29.9 -39.2 8 Int 53.25 50 7 29.9 -32.6 9 Int 56.5 106 7 28.3 -30.9 10 Int 79.25 162 7 26.7 -29.4 -- - ----------- - -- -- -- -- - --- ..._.-- -- - --- -- ... --- - - - ._._...__... 11 Int 46.75 78 7 29.3 -31.9 ---.......----- - ...- ---... - --... ._. --..._.. _. ._.. 12 Int 160.5 111 7 26.1 28.7 13 Int 72.75 111 7 27.7 -30.3 14 End 37 58 7 30.4 -40.1 15 Int 37 70 7 30.0 -32.6 -- --- -- - -- -------- - - -- --... - - --- - -- - .. - - - - - - - 16 Int 59.75 71 7 29.0 -31.6 ---------------- ---- -----------...------------ - ----- -- -- ---- -- - ---------__._. -- -- -- - --- ----_.-- - 17 Int 46.75 71 7 29.5 -32.1 -- -- - - - - --- - - - -- - - - -- -- _ .___....._. . - ----- 18 Int 46.75 71 7 29.5 -32.1 --... ----- ------ --- - - ---- - -------- ----- ----- - - - --- - -- - - - - -- --- - - - 19 Int 46.75 71 7 29.5 -32.1 -.20 Int 160.5 42' 7 27.5 30.2 21 Int 286 42 7 25.2 -27.9 Prepared in accordance with:ASCE 7-10,Chapter 30,Wind Loads-Components and Cladding.Sth Edition(2014)Florida Building Code. Page 1 of 1 Identification Schedule for Opening Protective Device or System (The following mininnmt in ornration shall be provided to facilitate plat review and inspection of the proposed installation,opening,protective device or system) Address: 1680 Buttonbush Circle, Palm City, Fl 34990 Tvpe of Structure: PERMIT#: Dev. Device Device Opening Opening Shutter Shutter #Storni Anchor Header # Type Manufacturer Approval Width Height Width Height Bars Req. Spacing Reinf. Req 1. Accordion ASSA FBC 73.75 109 73.75 109 10 No `T' n 2. Accordion ASSA FBC 102 141 102 141 10 No 3. Accordion ASSA FBC 76 80 76 80 1.0 No 'o 4. Accordion ASSA FBC 76 80 76 80 10 No 0 5. Accordion ASSA FBC 160.5 111 160.5 111 10 No �_, CD 6. Accordion ASSA FBC 56.5 95 56.5 95 10 No Ca 7. Accordion ASSA FBC 53.25 50 53.25 50 10 No C73 8. Accordion ASSA FBC 53.25 50 53.25 50 10 No 9. Accordion ASSA FBC 56.5 106 56.5 106 10 No 10. Accordion ASSA FBC 79.25 162 79.25 162 10 No 11. Accordion ASSA FBC 46.75 78 46.75 78 10 No 1.2, Accordion ASSA FBC 1.60.5 111 160.5 111 10 No 13. Accordion ASSA FBC 72.75 111 72.75 111 10 No 14. Accordion ASSA FBC 37 58 37 58 10 No , 15. Accordion ASSA FBC 37 70 37 70 10 No 16. Accordion ASSA FBC 59.75 71 59.75 71 10 No 17. ' Accordion ASSA FBC 46.75 71 46.75 71 10 No 18. Accordion ASSA FBC 46.75 71 46.75 71 10 No 19. ' Accordion ASSA FBC 46.75 71 46.75 71 10 No 20. Accordion ASSA FBC 160.5 42 160.5 42 10 No 21. Accordion ASSA FBC 286 42 286 42 10 No i