Loading...
HomeMy WebLinkAboutEngineering RECEIVED NOV 10 2016 PAUL WELCH INC. Mechanical Electrical Civil Engineering 0 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie,FL 34984 Phone(772) 785 - 9888 p� E-mail pwelchinc@aol.com November 10, 2016 'Re: Rollins Re-Roof 10851 S Ocean Dr. #27 Jensen Beach, FL 34957 SCOPE OF WORK: Install new Metal Roof(Extreme Metal Fabricators, LLC "5-V Crimp"FL#17022.1)at above referenced address over new underlayment, and existing plywood sheathing. DESIGN CRITERIA: FBC 2014 ASCE7-10 PROJECT DATA: BUILDING HIEGHT= 10'-0" A=3' MEAN ROOF HIEGHT=<20' 'ROOF ANGLE=2:12 SHAPE=PITCHED GABLE ADJUSTMENT FACTOR= 1.00 IMPROTANCE FACTOR= 1.00 WIND VELOCITY V ult= 165MPH WIND VELOCITY V asd= 128 MPH EXPOSURE=D ENCLOSURE CLASS =ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT=-0.18 APPLIED UPLIFT DESIGN PRESSURES PER ASCE(PSF): ZONE 1 (Field)=-40.3 ZONE 2 (Perimeter/Ridge)_-68.0 ZONE 3 (Corners)_-99.8 Paul Welch Inc. Paul Wel&P-E Reg:-N- 29945 I�obembex'f `2016' '1 o.i 10851 Ocean Dr.#27 Jensen Beach,FL �' 1 O,o3 METAL ROOFING ATTACHMENT REOUIREMENTS: Metal roofing to be attached with corrosion resistant Hex-Head wood screws#10 x 1 minimum with weather sealing washers(minimum 3/16"penetration through deck). Fasteners shall be placed through the panel ribs at 12"on center across panel width and spacing along the ribs as follows: .ZONE 1 (Field):FASTENER SPACING= 16" O.C. ZONE 2 (Perimeter/Ridge): FASTENER SPACING= 16"O.C. ZONE 3 (Comers): FASTENER SPACING=8" O.C. NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF SLOPES UNDER 3 VERT. :12 HORZ. Design uplift Pressure for attachment as per above: Product Design Pressure:Zones 1 &2: -93.5PSF/Zone 3: -101PSF Therefore O.K. UNDERLAYMENT• Underlayment shall be in accordance with manufacturer's guidelines, FBC 1507.4.5.1,and FBC 15074.5.2. Underlayment shall be Approved 30#Roofing Felt or UDL 25 plus NOA# 13- 0730.01. DECK INSTALLATION: Re-nail all plywood sheathing(15/32"thick minimum)with 8D ring-shank nails at 4"O.C. perimeter and 6" O.C. field for all zones. All work to be in compliance with product approval (FL# 17022.1), (NOA# 13-0730.01.), manufacturer's specifications,and the Florida Building Code 2014. Paul Welch Inc. Paul-Welch P.E.-'Reg.No.29945 1��Novemlierfl0 201b 10851 Ocean Dr.#27 Jensen Beach,FL .-• _ .': nom:, t .:•� I i K * M A -------------- y IMI li I i • illi H li f - j I `j i ROOF ZONE PLAN A=3' ZONE DESIGNATION(TYPICAL) NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF SLOPES UNDER 3 VERT. :12 HORZ. P� 7t1+V rllch;Ic. Paul W�lch,�F'E"Reg�o;29945 10851 Ocean Dr.#27 Jensen Beach,FL