HomeMy WebLinkAboutEVALUATION REPORT i it EXTERIORiRESEARCH&DESIGN,LLC. Certificate of Authorization#9503 "TkNrry( 353 CHRISTIAN STREET,UNIT#13 ERD i OXFORD,CT 06478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R7 One Owens Corning Parkway FI-10674-1112 Toledo,OH 43659 Date of Issuance:02/06/2012 Revision 7: 04/18/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted haslbeen reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code; Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code l; sections noted herein. j I DESCRIPTION: Owens Corning Asphalt Roof Shingles j LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement Ito notify'Robert Nieminen,P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD 'requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity[ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: t�pw1anuy,� I'' -� The facsimile seal a'p'pearing was authorized by Robert Nieminen, Robert J.M.Nieminen P.E. 1y7, goy a� s.\ P.E.on 04/18/2016.This does not serve as an electronically signed J/,ur,.pns�s - document.sI ned�sealed hardco ies have been transmitted to the Florida Registration No.59166,Florida DCA ANE1983 t' a P Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in,any company manufacturing or distributing products it evaluates. 2. Trinity ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or,distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way;the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting orldesign guidance unless retained specifically for that purpose. i' i! III I 1 r �I li i I I' TRINITY!ERD ROOFING SYSTEMS EVALUATION: I 1. SCOPE: " Product.Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 { 2008 3. REFERENCES: Entity Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 1 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs LI Various UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme*are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire'""are fiberglass reinforced,5-tab asphalt roof shingles. I' 4.1.4 Duration', TruDefinition® Duration, Duration Premium Cool, TruDefinition; Duration Designer Color Collection, TruDefinition Oakridge, Oakridge® and WeatherGuard� HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire® Hip & Ridge Shingles, High Ridge, WeatherGuard� HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidgeTm Hip&Ridge Shingles are fiberglass reinforced,hip andiridge asphalt roof shingles. 4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous�versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 FL10674-1132 Revision 7:04/18/2016 Page 2 of 8 i, i' TRINITY j ERD 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with' FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating thin shingles are acceptable for use in all wind zones up to Vasil=150 mph (V„it=194 mph). Refer to Section 6!for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip&ridge shingles,Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class•F,indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph (V„It=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. it 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule 61G20-3. I� 6. INSTALLATION: i 6_1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6_2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current$ublislied instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 o'r R905.2 , with the following exceptions: ➢ Berkshire shingles require minimum five(5)nails per shingle. ➢ WeatherGuarda HP shingles require minimum six(6)nails per shingle. ➢ Devonshire'"shingles require minimum six(6)nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per stripi Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requiremll ents, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Felt underlayment Deck Fellunderlayment I! Deck Se�e dkV Self-adhered undedayment WeatherLocka underlayment ' Drip edge Drip Drip edge Drip— edge edge . Nags located Nails located 2"- fromeave 2"-3"from eave Install first Self-sealing adhesive Setr�e�ng adhesive Starter Strip elf-sealingan cave Instal first Starter Strip Plus poshlonedalongeave P 9 with6'removed shingle with 6"removedStarter Strip shingle overhangs eaves and rakes/ Starter Strip Plus overhangs eaves and rakes 114-3/4' ' MV--VA" j Exterior Research and Design,I.I.C. i Evaluation Report 037940.02.12-R7 Certificate of Authorization 119503 FL10674-R12 Revision 7:04/18/2016 Page 3 of 8 w;1 f 1 TRINITY ERS 6.2.6 Minimum Nailing—Classic®&Supreme: z'II Normal Mansjd* Area pans Normal Mansard or Aren,para Wind Areas High desv-n.s y Wind Areae High Wind deavanes y Area pare vientos normales Areasvientos faartes Area para vientos normalee l:Areas vientos fuertes t• Bl'.. 1" - (AI, �• t° 2° lel 'Z° t° tt• tr tzt •— tzt • s N 5"Exposure 6 5/8"Exposure; ;P. Exposlawn Exposiei6n I I,1 .,Illi 6.2.7 Minimum Nailing—Berkshire®: ,a Sealant strip Sealant strip La tira de sell ador La tlra de selladar Go i 9V Sof syfl t 81 Standard srlt stn°t„ r r 1,1 Standard Fastening Pattern 6-Nail FastIening Pattern a Sealant strip i Lafba deselladar �t1e'_.--tee. 'ef ►-eY '• W218 y2" 8 VV 8 Asphalcreeling cement I'll Cemeoto;0etaohodeaslatW '�;}' i Mansard or Steep Slope Fastening Pattern, I' ;Lail i i II, Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 j l'i; F1.10674-R12 14. Revision 7:04/18/2016 Page 4 of 8 ,.h I'll, TRINITY I ERD 6.2.8 Minimum Nailing—Devonshire'^": I �IJ ,ji 7" 8" 8- nn ,n 'I' V Id Na r ;il 47 qwm _ ll'Nails r r U t r exposure Sealant location lw a Exposici6n de 5.5/8 pulg Ubicaci6n del sellador �W Ten 1"Spots'of Asphalt Roof Cement Standard 6-Nail Fastening Pattern Mansard for Steep SI'gpe Fastening Pattern 6.2.9 Minimum Nailing—Duration®,TruDefinition® Duration, Duration® Premium Cool &TruDefinition Duration® Designer Color Collection: I 4-Nall Fastening Pattem 6•4all Fastening Pattern I SmNalIVI 5tening area VACN III r-Sme bunt m.Inaare dth Nail,lypic '. Naa;7yplCai 1 12" 1" 1^ 12" { I 19 F— j I a u,eo �vw • t,».rc P•w"oe .n _'o.4sm�as.w,rY,�.t4 �7u«w. ..mrt:ux ,� �s ;n baa. r_ Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 sunNaiFB rastsnhg ae°rnaul 3�j'I all.TyPioal Ijj � .xses=.� w.r-• �.w,�"�'•—^++.iz"-� ;III A, `J III Ioj Four 1^Spalls°(ASpNit Roofna Cement Mansard or Steep Slope Fastening Pattern 31G ' Y1 %i II ' Exterior Research and Design,I.I.C. !Evaluation Report 037940.02.12-1117 Certificate of Authorization#9503 FL10674-R12 'h Revision 7:04/18/2016 Page 5 of 8 {i + 'I TRINITY j ERD IIS 6.2.1 Minimum Nailing—TruDefinition®Oakridge",Oakridge®: I' 4.Nall Pattern 6 Nall Pattern i. Esquema con 4 davos Esquema con 6 x Javos r r 5518"Exposure Nails 6 518"Exposure. Nails &poSiolde5618putg Ctavos Exposid6a'do66/8pufg. 5518"Exposuie C�jv� 5.6/8"Exposure aposkionde'66/8&1g. Exposrcioade66/Bputg. Standard Fastening Pattern 6-Nail Fast'e"'ping Pattern Fastening for Slopes Greater Than 21:12 ±I SuroaaWasteningdr6awtdth it n4 Typicer +^ u- +r +^ i Four 1-Spots of Asphalt Roofing C—t I Mansard or Steep Slope Fastening Pattern 'I i 6.2.1 Minimum Nailing—WeatherGuard"HP: I ' I j1 I q , l 'I I.I ,I ii i ai Exterior Research and Design,LLC. Evaluation Report 037940.02.12-117 Certificate of Authorization#9503 F1.10674-11112 Revision 7:04/18/2016 j Page 6 of 8 I I it I I' I'I i, I 14 TRINITY I ERD 6_3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard*HP Hip and Ridge Shingles and ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,using four (4) nails per shingle. Installation of DuraRidge'" Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the ulse of hand-sealing for wind warranties. i i 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig.1 Fig.2 t— PI btradcu on nbVllnd Topmew '! S[Myi w / A III Nails i... A Nails IH it Nails 4 t^;..Z. "Laninatel .,i7Li 4- PICCU 4 I I I I I j 1 P i I 1 I j I i I I' n tr q,I 6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge: I Fig.C Hip&Ridge Shingle Fastening 44 Fig. —breclb9wuw P TopVbw A (lolls A tlalis Nails Z' i I F I I I I I s—� Esposure V. Exposwe i 17 III I 1 i i Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 i FL10674-R12 Revision 7:04/18/2016 Page 7 of 8 ii 'jl |~ 'l|" .` 9�INITYJERD 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard Wind Direction Sealant Strip Fastening Pattern 12, Sealant Fasten 711? 6 7 11z Exposure Cove,1xo F. ked 'Roof Cement iA - 6.3.6 Minimum Nailing—DuraRidge"I Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. N4nCitrigWincl Diroction Top View Nalig------------------ IRMA � 7' LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required'classifications detailed in F8C Table 15O7.ZJ.1/R9OS.Z.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properil,,V evaluate the installation of if this product. | ' . 9' &UAmup4cTummsPuux7s: Contact the named QA entity for information on which plants produce products covelred by Florida Rule 9N'3 QA requirements. |� 10. QuAun(AssunAwcc2mTnY: !� |� ULLLC—OWA96IS;(414)248'6409 - END OFEVALUATION REPORT' |� .� ! � | Exterior Research and Design,uc Evaluation Report 037940.02.12-R7 Certificate ofAuthorization m95a |` nL10674-n12 | Revision 7:04/18/2016 ' Page nmx i� K / 1u ��