Loading...
HomeMy WebLinkAboutEngineering COOK & MENARD ARCHITECTURE INC. 806 Delaware Avenue, Fort Pierce, Florida 34950 NONE (772) 460-7751 FAX(772)460-4244 Nov P � EMAIL cookmenard@yahoo.com October 26, 2016 5alnt Lucie County Building Department Attn: Roof Permit Plan Review 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure located at 6511 Fort Pierce, Saint Lucie County, Florida Manufacturer: Gulf Coast Supply & Manufacturing Profiles: 26 GA GulfLok Roof Panel FL.#11651.12 Code: FBC 2014; Section R 905.10 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Exposure: B Mean Roof Height: 30' Maximum Pitch: 4/12 Required Design Pressure: Zone1: -38.2 Zone 2: -53.9 Zone3: -101.4 Maximum Uplift Pressure: Fastener spacing: -108.5 psf @ 12" o.c. Fasteners: #9-15x 1.5" w/sealing washing through panel rib, with'/" minimum penetration spaced @ 12"o.c. zone 1,2,3 Underlayment: Soprema, Inc. FL# 2569.1 Resisto is a self-adhering, glass-mat reinforced, sand-surfaced, sbs modified bitumen_ Roof Decking: Existing plywood sheathing to be nailed w/8d x2"ring shank nails @ 6" o.c. thru out Zone 1,4" o.c. perimeter& 6" o.c. field Zone 2, and 4" o.c.thru out Zone3 The above approved, as per Florida Building Code Compliance acceptances, 2014 Florida Building Code, and the Manufacturer's recommendations. t Respectrfully Submitted 1 } k k�,`.: fsh� �rte-`. tib k ate-✓q'' - .A hs -Peter B Cook Cook& Menard Architecture; Inc.' Florida Registration No. AA0003494, NCARB Certification No. 31789