HomeMy WebLinkAboutEngineering COOK & MENARD ARCHITECTURE INC.
806 Delaware Avenue, Fort Pierce, Florida 34950
NONE (772) 460-7751 FAX(772)460-4244
Nov P � EMAIL cookmenard@yahoo.com
October 26, 2016
5alnt Lucie County Building Department
Attn: Roof Permit Plan Review
2300 Virginia Avenue
Ft. Pierce, FL 34982
Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure located at
6511 Fort Pierce, Saint Lucie County, Florida
Manufacturer: Gulf Coast Supply & Manufacturing
Profiles: 26 GA GulfLok Roof Panel FL.#11651.12
Code: FBC 2014; Section R 905.10
Wind Speed: 160 MPH; Ultimate Design Wind Speeds
Exposure: B
Mean Roof Height: 30' Maximum
Pitch: 4/12
Required Design Pressure: Zone1: -38.2 Zone 2: -53.9 Zone3: -101.4
Maximum Uplift Pressure: Fastener spacing: -108.5 psf @ 12" o.c.
Fasteners: #9-15x 1.5" w/sealing washing through panel rib, with'/" minimum penetration
spaced @ 12"o.c. zone 1,2,3
Underlayment: Soprema, Inc. FL# 2569.1 Resisto is a self-adhering, glass-mat reinforced,
sand-surfaced, sbs modified bitumen_
Roof Decking: Existing plywood sheathing to be nailed w/8d x2"ring shank nails @ 6" o.c. thru
out Zone 1,4" o.c. perimeter& 6" o.c. field Zone 2, and 4" o.c.thru out Zone3
The above approved, as per Florida Building Code Compliance acceptances, 2014 Florida Building Code, and the
Manufacturer's recommendations.
t
Respectrfully Submitted
1 } k k�,`.:
fsh� �rte-`. tib k ate-✓q'' -
.A
hs
-Peter B Cook
Cook& Menard Architecture; Inc.'
Florida Registration No. AA0003494, NCARB Certification No. 31789