Loading...
HomeMy WebLinkAboutProduct Approval orida Building Code Onlifieiittp:itwww.iioriaat)ulictmg.oi:gipripil-iipp__�ULL.dbpx'jjttLa111—W"jj..�V./%�... RECEIVED NOV M 2016 ........ 13 BCM Home Log In User Registration Hot To plcs Submit Surcharge Stats&Facts Publications F5C Staff SCIS Site Ma Bu si Product Approval Profess i 6'1'(a j USER:Public User >Rj-_dkg&_qr Anokation Search.ch.>Ai)&at:*�q �st>Application Detail FL FL2569-Rl1 Application Type Revision Code Version 2014 Application Status ApproMed Comments Archived Product Manufacturer Soprema,Inc. (Canada) Address/Phone/Email 1640 rue Haggarty Drummondville, NON-US 00000 (819)47B-2400 Ext 3327 memathieu@s.oprema-ca Authorized Signature Marc-Etienne Mathieu memathieu@sqprema.ca Technical Representative Marc-Etienne Mathieu Address/Phone/Email 1688 lean-Berchmans-Michaud Drummondville,NON-US 00000 (819)478-2400 Ext 3327 memathie.u@soprem.a.ca Quality Assuranc6 Representative Jean-Francois Cote, Ph.D. Address/Phone/Email 1640 rue Haggarty Drummondville (888)811-3145 jfcote@soprema.ca Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect o Florida Professional Engineer. Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed -Robert J. M. Nieminen the Evaluation Report - Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/16/2017 Validated By John W. Knezevich, P*JE f3 1/5/2016 3:08 PM oridaBuildingCode Online nttp:iiwww:Fiorlaaouuaing.orgrpripf�_:app_u«.aspa:pata,rt—wit vn... ;, Validation Checklist-Hardcopy Received Certificate of Independence FL2569_R11 CUI 2015 t]'_1_ COI Referenced Standard and Year(of Standard) Standard ASTM D1970 ASTM D6163 ASTM D6164 FM 4474 FRSA/TRI April 2012 (04-12) TAS 103 TAS 110 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/15/2015 Date Validated 10/19/2015 Date Pending FBC Approval 10/21/2015 Date Approved 12/15/2015 Summary of Products iFL# Model, Number or !Description Name f 2569.1 Soprema Roof Self adhering roof underlayments Underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL2569 R11 Ii "2015 10 FINAL FR SOPREMA. CA UNDcRLA`P Approved for use outside. P 1,1,pd HVHZ:Yes 1 Verified By: Robert Niemineri, P.E. PE-59166 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-90 Evaluation Reports Other: 1.) Refer to ER Section 5 for FL2a69 R11 AE 2015 IQ FINAL ER SOPREMA.CA UNDERLAY Limits of Use, 2.)The design pressure R11. noted'herein pertains to underlayment Created by Independent Third Party: Yes systems used.beneath adhesive-set tile' systems. Refer to ER Section 5.6.4 for details. each Next Contact Us::1940 North Monroe Street Tallahassee FL 32399 Phone:850-487=1824 The State of Florida is an AA/EEO employer. nvraht 2007 2013 State of Florida.::privacy Statement:;Accessibility Statemen@ BI Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records req F3 1%5/2016 3:08 PM oijda Building Code Online nttp:i/www.rioriaaduitaing.orgipr/pr_dpp_uu,dSpxcpdrdttl—Wkiz v n..: electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questlons,please contact 850.487. Section 455.275(1),Florida Statutes,effective Octo ber 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department wi they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.D supply a personal address;please provide the Department with an email address which can be made available to the public.To determine W yo Chapter 455,F.S.,please clickeh re,. Product Approval Accepts: '3 1/5/201.6 3:08 PM -' EXTERIOR RESGARCH&DGSIG �LkC. Certificate of Authorization#_9503 3S3CHRGT�NSTREE�UN|T#I3 Ek��� ��11 411 1 ���� OXFORD,CT 06478 � PHONE:(ZO3)26Z-824S FAX:(ZO3)IG3'9Z43 EVALUATION REPORT — Soprema, Inc. Evaluation Report S18010.06.09-R9 1o*vrue Haggerty PrummondviUe,Du6bec]%[5PQ Date mfIssuance:06/1S/20OB Canada __,__^ �en��/� ;1 � �/1��2015 SCOPE" This Evaluation Report.is issued under Rule 61G20'3 and the applicable rules and regulations the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the pvoduct nnder the Florida Building Code and Florida Building Code, Residential Volume. The prodbctm described herein have been evaluated for compliance with the S thEdidon (2014) Florida Building Code sections noted herein. DESCRIPTION: SopmemmaRoof Undm Luosummr Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. � CONTINVED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of bP.E. this Evaluation* Report bythe named client constitutes agreement to notify Robert m/emn/nen' p' ' /fthe product changes orthe referenced Quality Assurance documentation changes. Trinity|ERDrequires acomplete review ofthis Evaluation Repo rt relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity I ERD Evaluated" may be displayed in odyettisinQUternture' |fany portion ofthe Evaluation Report iadisplayed,thenitshaUbedonmin'itsentirety. |mSpecTIOm: UpoumequestocopyofthisentiveEva|uationReportyhaUbeprovi6edtothouser6Ythemanufactureror its.distributors and shall be available for inspection at theJob site-at the request of the Building Official. This Evaluation Report consists ofpages 1through l Prepared by: ' ----- ` Robert J.M. Niemo]mem,P'E' The~ ~^ ~^"~~'~"~~=thonzed by Robert ^~—'~^ ^a."^wu21z1,.This does not serve.as=^lectio"icawsigned Florida Registration No.59156,Florida DCA ANB983 � �����"���������� - rrodu=*mro=/^u°m*trai* and mthe named a*= . ccm`"ICATIuwupINDEPENDENCE: 1. TMnity[ERQdoes not have, not does |tintend tnacqulneorwill it acquire, afinancial interest in any company manofactur(ng-or distributing products uevaluates. .2. Trinityl ERD Is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. a. Robert Nleminen,P.E.does not have nor will acquire,a financial interestin any Company manufacturing or distributing products for which the.exo|uat|nnreports are being issued. 4. Robert Nierninen,R.E.does not have, nor will acquire,a financial interest in any other entity involved in't[Te approval process of the , product. s. This /,a building code evaluation. Neither Trinity|com nor Robert m/emmen' P.s. are,in anyway,theoe,/onerpfRecord for any project on Which this am(uadnn Kepor�or previous versions thereof,is/was used for permitting ordesign guidance unless retained specifically for that purpose. ' ' ` IN I ROOFING COMPONENT EVALUATim 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is'subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. STANDARDS: Section Property Standard Year 1504.3.1 Wind Resistance FM 4474 2004 1507.2.4,1507.2.8, Physical Properties ASTM D1970 2009 1507.2.9.2,1507.4.5.1, 1507.5.3,1507.7.3 1507.11.2 Physical Properties ASTM D6163 2000 1507.11.2 Physical Properties ASTM D6164 2005. 1523.6.5.2.1 Physical Properties TAS 103 1995 TAS110 Accelerated Weathering TAS 110 - 2000 1507.3..3 Installation Practice FRSA/TRI April 2012(04-12) 2012 3. REFERENCES: Entity Examination Reference Date ERD(TST6049) ASTM D1970/TAS 110 29`68.05.04-2 05/14/2004 ERD(TST6049) Physical Properties 2757.02.05 02/03/2005 ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005 ERD(TST6049) Wind Resistance 2778.07.05 07/.15/2005 ERD(TST6049) Wind Resistance 2779.11.05-R1 04/18/2007 ERD(TST6049) TAS 103/TAS 110 S7120.11.07-2 11/02/2007 ERD(TST6049) ASTM D1970/TAS 110 513190.02.09-R1 04/01/2010 ERD(TST6049) ASTM D1970/TAS 110 531370.03.10-1-R1 04/07/2610 ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.10-R1 09/09/2010 ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.09-112 10/05/2010 ERD(TST6049) ASTM D1970 . 537210.11.11 11/09/2011 ERD(TST6049) ASTM D1970 540540.02.13-1 02/19/2013 ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.14-1 02/21/2014 ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015 M-D(CER1592) HVHZ Compliance 09-1005.02 11/04/2010 M-D(CER1592) HVHZ Compliance 13-0530.02 11/27/2014 ]CC-ES(EVL2396) 2012,2009 and 2006 IBC Compliance ESR-1524 10/01/2014 PRI (TST5878) Physical Properties SOP-064-02-01 12/03/2013 Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 05/29/2015 UL,LLC(QUA9625) Quality Control Service Confirmation EXp.10116/2017 4. PRODUCT DESCRIPTION: 4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof underlayment. 4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths;36 and 45 inch. 4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment;available in 3.3 ft x 65 ft rolls. Exterior Research and Design,LLC. Evaluation Report S18010.06.09-119 Certrykote ofAuthor)zotron#9503 fL2569-R11 .. . Revision 9-10/12/2015 Page 2 of 7 ^ i^ T�� `� ) 17 � 4.4 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, high temperature, S85 modified bitumen roof undodayment 4�5 Laetobnnd Pro HT-N is a se|f-adhering, woven polyethylene surfaced, SBS modified bitumen roof undedoymentavailable intwo widths;36and 4Sinch. 4.6 Lagobond Pro HT-S is o self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumenroof under|ayment. 4'7 Lastobnnd 195 is a se|f-adherin8' glass-mat reinforced,. sand-surfaced, SBS modified bitumen roof undedayment 4.8 Lastobnnd is a self-adhering- glass-mat reinforced, sand-surfaced, SBS modified bitumen roof undm1ayment. 4.9 La�nbond Eco is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof ' undedaymwnt. 4.10 LontobondSmooth Seal HT|s a solfadhohng, glass-mat reinforced, 0|m-.surfaced SBS modified bitumen roofundedayment 4.11 RESISTO LB1236 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof undeduyment,with a36'inchsheet width. 4.12 PdmeSourceGrip-RiteEave &VaUeyPm¢ectorisese|f'adhehnA,8|ass-matnainforced,sand'yurfaced'S83 modiHedbitvmenroofundeduyment'w}tha36'inchsheetxv|dth. 4.13 RE8STO L81244 is a xe[f-adhering, glass-mat reinforced, sand-surfaced, S85 modified bitumen rpu[ undadaymantwith a44'inchsheet width. 4.14 Co[obene FR SR is o self-adhering, fiberglass reinforced, granule-surfaced, SBS modified bitumen roof under|ayment 4-15 Uni|ay (e) is mechanically attached, polyester reinforced, granule-surfaced, SBS. modified bitumen roof ondedaymemt. 5" Uxximoms: 5.1 This is a building code evaluation. NeitherTdnity[ERD nor Robert Nieminen, P.E. are, in any . the Designer ofRecord for any project.unwhich this Evaluation Report, orpreviouo-versionsthereot is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Eva|uot\onReport isnot for use inthe HVHZ. S3 Fire Classification iynot part ofthis.report; refer tocurrent Approved goofing Materials Directory for fire ' ratings-of this product. ` E.4 Soprema Roof Underlayrnents may be used with any prepared roof cover where the product is specifically referenced within FBCapproval documents. |fnot listed,arequest may bemade tothe AH] for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable.roof covers applied atop the undedoymantsare follows: TAKE 1: ROOF COVER OPTIONS Underlayment Asphalt Nail-On Foam-On Metal Wood Shakes& Slate Shingles Tile Tile Shingles Yes Lastobond TU HT Yes Yes Yes Yes Yes See 5.5.1 RESISTO SA SMOOTH PLY 40 Yes No No No Yes YesLastobond Shield HT/Pro HT-S Yes No No Yes Yes Yes Lastobond/Lastobond 195 Yes No No No Yes Yes Exterior Research and Design,LLC. Evaluation Report s1on1o.0soe-Ry c=tfica*ofxm*drimtio"*9503 rL25e-Rll ` Revision 9:10/12/2015 Page smr RIN ` RED TABLE 1: RooF COVER OpT10Ns Underlayment Asphalt Nail-On Foam-On Metal Slate Wood Shakes& Shingles Tile Tile Shingles Lastobond ECO /RESISTO 1_131236,Grip-Rite Eave&Valley Yes. No No No Yes Yes Protector/RESISTO LB1244 Lastobond Smooth Seal HT Yes No No Yes Yes Yes Yes Colphene FR GR Yes Yes See 55.1 No Yes Yes Yes Yes Unilay(e) Yes Batten Only See 55.1 No No No 5.5.1 "Foam-On Tile" is limited to.use of the following adhesives unless tensile adhesion/ long term aging data from an.accredited testing laboratory is provided. Underlayment Adhesive(s) Lastobond TU HT 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)or Dow Chemical TileBond'l"Roof Tile Adhesive(FL717) Colphene FR GR 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332) Unilay(e) 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332) 5.6 Allowable substrates are noted below: 5.6.1 Direct-Bond to Deck: . Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HTS, Lastobond TU HT, Lastobond, Lastobond 195,. Lastobond ECO, RESISTO LB1236, Grip-Rite Eave & Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to: > Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D41 primed Southern Yellow Pine;ASTM D41 primed structural concrete. Colphene FR GR applied to: r Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete. Note: While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours. > Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation ofthe self-adhering underlayment. 5.6.2 Bond-to-insulation: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Lastobond TU HT, Lastobond,. Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave & Valley Protector, RESISTO L51244, Lastbbond Smooth Seal HT or Colphene FR GR applied to.: 8 Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile systems(Lastobond TU HT only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D or TAS 114,Appendix J. Exterior Research and Design,LLC. Evaluation Report 518010.06.09-R9 Certifrcate ofAuthorizatiob#9503 FL2569-R11 Revision 9.10/12/2015 Page 4 of � . . N 5.6.3 Bond to MechanicaliV Attached Base Laver: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave & Valley Protector,RESISTO LB124.4, Lastobond Smooth Seal HT or Colphene FR GR applied to: > ASTM D226,Type I or 11 felt;Sopra-G; Modified Sopra-G. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems (Lastobond TU HT only), base layer shall be attached in accordance with FRSA/TRI April 2012(04-12).. .5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on the systems;where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-ori the applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind pressures. 5.6:4.1 Maximum Design Pressure=-45.0 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional) Elastocol Stick or Elastocol 600c Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. 5.6.4.2. Maximum Design Pressure=-67.5 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: Elastocol 600c Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. 5.6.4.3 Maximum Design Pressure=-60.0 psf. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps(FBC 1517.5.2)spaced 6-inch o.c.at the 4-inch laps and.6-inch o.c.in three,equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered 5.6.4.4 Maximum Design Pressure=-90:0 psf. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Underlayment: Unilay(e) mechanically attached with Soprafix Polymer Batten Bar (PB8) or Soprafix Metal Batten Bar(MBB) with Soprema#15-EL fasteners spaced 6-inch o.c.within the 5- inch wide, self-adhering side laps. End laps are 64nch wide and sealed using either heat-welding or hot-air welding techniques. 5.7 Exposure Limitations: Lastobond, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236, Grip-Rite Eave & i Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after installation. Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond Pro HT-S shall not be left exposed for longer than 90-days after installation. Lastobond TU HT or Colphene FR GR or Unilay(e)shall not be left exposed for longerthan 180-days.after installation. Exterior Research and Design,LLC. Evaluation Report 528010:06.09-R9 Certificate of Authorisation#9503 FL2569-RIl :Revision 9s 10/1212015. Pages of 7 TRINII ITU 6. INSTALLATION: 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick or Elastocol 600c(if applicable). 6.3 Lastobond TU HT Lastobond Shield Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,_Lastobond Shield HT Lastobond Pro HT-S,Lastobond Lastobond 195 Lastobond Eco.Lastobond Smooth Seal HT,RESISTO L81236 Grip-Rite Eave&Valley Protector RESISTO LB1244 or Colphene FR GR: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 Non-Tile Applications: While priming is optional,Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover Is not slated for installation within.24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of rel.ease.fiim. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane tight..Firmly roil the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques. When installing at slopes above 8:12,Soprema recommends back-nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction: For valleys,apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam-on tile applications, reference is made to Section_5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRl April 2012(04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. 66.4. Unila e : 6.4.1 Non-Tile Applications or Nail-On,Battened Tile Applications: Reference is made to Table 1 herein and FRSA/TRI April 2012(04-12) Installation Manual(if applicable). Apply sheet parallel to the roof edge and, starting at the eave with the selvedge-edge upslope, mechanically attach the 5-inch wide selvedge-edge to the wood deck with nails and tin caps or round cap- nails spaced 36-inch o_c. Apply the second course in a water-shedding manner with self-adhering side- laps. Vigorous hand or motorized roller pressure is applied to the self-adhering laps to ensure a watertight application. Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques. Exterior Research and Design,LLC. Evaluation Report S18010.06.09-R9 Certificate ofAutharization#9503 FL2569-R11 Revision 9.:10/12/2015 Page 6 of 7 yEL't..�t5 ��• F ? Tile(if applicable)shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment: 6.4.2 Foam-On Tile Applications: Reference is made.to FRSA/TRI April 2012 (04-12) Installation Manual, Table 1 herein and Section 5.6.4.4 herein. Apply sheet parallel to the roof edge and; starting at the eave with the selvedge-edge upslope, mechanically,attach the 5-inch wide selvedge-edge-to the wood deck Soprafix Polymer Batten Bar(PBB)or Soprafix Metal Batten Bar (MBB) with Soprema #15-EL fasteners spaced 6-inch o.c. Apply the second course in a water-shedding manner with self-adhering side-laps. Vigorous hand or motorized roller pressure is applied to the self-adhering laps to ensure a watertight application. Vertical seams should be 6-inches and staggered not less than 24t from vertical seams in the course below. All over-granule end-laps shall be sealed using either.heat-welding or hot air welding techniques. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to .the underlayment. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building official or Authority Having Jurisdiction in order to properly evaluate the.installation of this.product. 8. MANUFACTURING PLANTS: Contact the manufacturer or the named QA entity for information on plants covered under Rule 61620-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com -END OF EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation.Report S18010.06.09-119 Certiflcate of Autharization.k9503 FL2569-R11 Revision 9:10/12/2015 Page 7 of 7