FL FL2569-Rl1
Application Type Revision
Code Version 2014
Application Status ApproMed
Comments
Archived
Product Manufacturer Soprema,Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON-US 00000
(819)47B-2400 Ext 3327
memathieu@s.oprema-ca
Authorized Signature Marc-Etienne Mathieu
memathieu@sqprema.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 lean-Berchmans-Michaud
Drummondville,NON-US 00000
(819)478-2400 Ext 3327
memathie.u@soprem.a.ca
Quality Assuranc6 Representative Jean-Francois Cote, Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect o
Florida Professional Engineer.
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed -Robert J. M. Nieminen
the Evaluation Report -
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/16/2017
Validated By John W. Knezevich, P*JE
f3 1/5/2016 3:08 PM
oridaBuildingCode Online nttp:iiwww:Fiorlaaouuaing.orgrpripf�_:app_u«.aspa:pata,rt—wit vn...
;, Validation Checklist-Hardcopy Received
Certificate of Independence FL2569_R11 CUI 2015 t]'_1_ COI
Referenced Standard and Year(of Standard) Standard
ASTM D1970
ASTM D6163
ASTM D6164
FM 4474
FRSA/TRI April 2012 (04-12)
TAS 103
TAS 110
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/15/2015
Date Validated 10/19/2015
Date Pending FBC Approval 10/21/2015
Date Approved 12/15/2015
Summary of Products
iFL# Model, Number or !Description
Name f
2569.1 Soprema Roof Self adhering roof underlayments
Underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL2569 R11 Ii "2015 10 FINAL FR SOPREMA. CA UNDcRLA`P
Approved for use outside. P 1,1,pd
HVHZ:Yes 1 Verified By: Robert Niemineri, P.E. PE-59166
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-90 Evaluation Reports
Other: 1.) Refer to ER Section 5 for FL2a69 R11 AE 2015 IQ FINAL ER SOPREMA.CA UNDERLAY
Limits of Use, 2.)The design pressure R11.
noted'herein pertains to underlayment Created by Independent Third Party: Yes
systems used.beneath adhesive-set tile'
systems. Refer to ER Section 5.6.4 for
details.
each Next
Contact Us::1940 North Monroe Street Tallahassee FL 32399 Phone:850-487=1824
The State of Florida is an AA/EEO employer. nvraht 2007 2013 State of Florida.::privacy Statement:;Accessibility Statemen@ BI
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records req
F3 1%5/2016 3:08 PM
oijda Building Code Online nttp:i/www.rioriaaduitaing.orgipr/pr_dpp_uu,dSpxcpdrdttl—Wkiz v n..:
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questlons,please contact 850.487.
Section 455.275(1),Florida Statutes,effective Octo ber 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department wi
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.D
supply a personal address;please provide the Department with an email address which can be made available to the public.To determine W yo
Chapter 455,F.S.,please clickeh re,.
Product Approval Accepts:
'3 1/5/201.6 3:08 PM
-' EXTERIOR RESGARCH&DGSIG �LkC.
Certificate of Authorization#_9503
3S3CHRGT�NSTREE�UN|T#I3
Ek���
��11 411 1 ���� OXFORD,CT 06478
� PHONE:(ZO3)26Z-824S
FAX:(ZO3)IG3'9Z43
EVALUATION REPORT —
Soprema, Inc. Evaluation Report S18010.06.09-R9
1o*vrue Haggerty
PrummondviUe,Du6bec]%[5PQ Date mfIssuance:06/1S/20OB
Canada __,__^
�en��/� ;1
� �/1��2015
SCOPE"
This Evaluation Report.is issued under Rule 61G20'3 and the applicable rules and regulations the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the pvoduct nnder the Florida Building Code and Florida Building Code, Residential Volume. The
prodbctm described herein have been evaluated for compliance with the S thEdidon (2014) Florida Building Code
sections noted herein.
DESCRIPTION: SopmemmaRoof Undm
Luosummr Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein. �
CONTINVED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
bP.E.
this Evaluation* Report bythe named client constitutes agreement to notify Robert m/emn/nen' p' ' /fthe product
changes orthe referenced Quality Assurance documentation changes. Trinity|ERDrequires acomplete review ofthis
Evaluation Repo rt relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity I ERD Evaluated" may be displayed in
odyettisinQUternture' |fany portion ofthe Evaluation Report iadisplayed,thenitshaUbedonmin'itsentirety.
|mSpecTIOm: UpoumequestocopyofthisentiveEva|uationReportyhaUbeprovi6edtothouser6Ythemanufactureror
its.distributors and shall be available for inspection at theJob site-at the request of the Building Official.
This Evaluation Report consists ofpages 1through l
Prepared by:
'
-----
`
Robert J.M. Niemo]mem,P'E' The~ ~^ ~^"~~'~"~~=thonzed by Robert
^~—'~^
^a."^wu21z1,.This does not serve.as=^lectio"icawsigned
Florida Registration No.59156,Florida DCA ANB983 � �����"����������
- rrodu=*mro=/^u°m*trai* and mthe named a*= .
ccm`"ICATIuwupINDEPENDENCE:
1. TMnity[ERQdoes not have, not does |tintend tnacqulneorwill it acquire, afinancial interest in any company manofactur(ng-or
distributing products uevaluates.
.2. Trinityl ERD Is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
a. Robert Nleminen,P.E.does not have nor will acquire,a financial interestin any Company manufacturing or distributing products for
which the.exo|uat|nnreports are being issued.
4. Robert Nierninen,R.E.does not have, nor will acquire,a financial interest in any other entity involved in't[Te approval process of the
,
product.
s. This /,a building code evaluation. Neither Trinity|com nor Robert m/emmen' P.s. are,in anyway,theoe,/onerpfRecord for any
project on Which this am(uadnn Kepor�or previous versions thereof,is/was used for permitting ordesign guidance unless retained
specifically for that purpose.
'
'
` IN I
ROOFING COMPONENT EVALUATim
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the Florida Building Code through testing in accordance with the following Standards.
Compliance is'subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
STANDARDS:
Section Property Standard Year
1504.3.1 Wind Resistance FM 4474 2004
1507.2.4,1507.2.8, Physical Properties ASTM D1970 2009
1507.2.9.2,1507.4.5.1,
1507.5.3,1507.7.3
1507.11.2 Physical Properties ASTM D6163 2000
1507.11.2 Physical Properties ASTM D6164 2005.
1523.6.5.2.1 Physical Properties TAS 103 1995
TAS110 Accelerated Weathering TAS 110 - 2000
1507.3..3 Installation Practice FRSA/TRI April 2012(04-12) 2012
3. REFERENCES:
Entity Examination Reference Date
ERD(TST6049) ASTM D1970/TAS 110 29`68.05.04-2 05/14/2004
ERD(TST6049) Physical Properties 2757.02.05 02/03/2005
ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005
ERD(TST6049) Wind Resistance 2778.07.05 07/.15/2005
ERD(TST6049) Wind Resistance 2779.11.05-R1 04/18/2007
ERD(TST6049) TAS 103/TAS 110 S7120.11.07-2 11/02/2007
ERD(TST6049) ASTM D1970/TAS 110 513190.02.09-R1 04/01/2010
ERD(TST6049) ASTM D1970/TAS 110 531370.03.10-1-R1 04/07/2610
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.10-R1 09/09/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.09-112 10/05/2010
ERD(TST6049) ASTM D1970 . 537210.11.11 11/09/2011
ERD(TST6049) ASTM D1970 540540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.14-1 02/21/2014
ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015
M-D(CER1592) HVHZ Compliance 09-1005.02 11/04/2010
M-D(CER1592) HVHZ Compliance 13-0530.02 11/27/2014
]CC-ES(EVL2396) 2012,2009 and 2006 IBC Compliance ESR-1524 10/01/2014
PRI (TST5878) Physical Properties SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 05/29/2015
UL,LLC(QUA9625) Quality Control Service Confirmation EXp.10116/2017
4. PRODUCT DESCRIPTION:
4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof
underlayment.
4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment available in two widths;36 and 45 inch.
4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment;available in 3.3 ft x 65 ft rolls.
Exterior Research and Design,LLC. Evaluation Report S18010.06.09-119
Certrykote ofAuthor)zotron#9503 fL2569-R11
.. . Revision 9-10/12/2015
Page 2 of 7
^
i^ T��
`� )
17
�
4.4 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, high temperature, S85 modified
bitumen roof undodayment
4�5 Laetobnnd Pro HT-N is a se|f-adhering, woven polyethylene surfaced, SBS modified bitumen roof
undedoymentavailable intwo widths;36and 4Sinch.
4.6 Lagobond Pro HT-S is o self-adhering, woven polyethylene surfaced, high temperature, SBS modified
bitumenroof under|ayment.
4'7 Lastobnnd 195 is a se|f-adherin8' glass-mat reinforced,. sand-surfaced, SBS modified bitumen roof
undedayment
4.8 Lastobnnd is a self-adhering- glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
undm1ayment.
4.9 La�nbond Eco is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
' undedaymwnt.
4.10 LontobondSmooth Seal HT|s a solfadhohng, glass-mat reinforced, 0|m-.surfaced SBS modified bitumen
roofundedayment
4.11 RESISTO LB1236 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
undeduyment,with a36'inchsheet width.
4.12 PdmeSourceGrip-RiteEave &VaUeyPm¢ectorisese|f'adhehnA,8|ass-matnainforced,sand'yurfaced'S83
modiHedbitvmenroofundeduyment'w}tha36'inchsheetxv|dth.
4.13 RE8STO L81244 is a xe[f-adhering, glass-mat reinforced, sand-surfaced, S85 modified bitumen rpu[
undadaymantwith a44'inchsheet width.
4.14 Co[obene FR SR is o self-adhering, fiberglass reinforced, granule-surfaced, SBS modified bitumen roof
under|ayment
4-15 Uni|ay (e) is mechanically attached, polyester reinforced, granule-surfaced, SBS. modified bitumen roof
ondedaymemt.
5" Uxximoms:
5.1 This is a building code evaluation. NeitherTdnity[ERD nor Robert Nieminen, P.E. are, in any . the
Designer ofRecord for any project.unwhich this Evaluation Report, orpreviouo-versionsthereot is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Eva|uot\onReport isnot for use inthe HVHZ.
S3 Fire Classification iynot part ofthis.report; refer tocurrent Approved goofing Materials Directory for fire
'
ratings-of this product.
` E.4 Soprema Roof Underlayrnents may be used with any prepared roof cover where the product is specifically
referenced within FBCapproval documents. |fnot listed,arequest may bemade tothe AH] for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable.roof covers applied atop the undedoymantsare follows:
TAKE 1: ROOF COVER OPTIONS
Underlayment Asphalt Nail-On Foam-On Metal Wood Shakes& Slate
Shingles Tile Tile Shingles
Yes
Lastobond TU HT Yes Yes Yes Yes Yes
See 5.5.1
RESISTO SA SMOOTH PLY 40
Yes No No No Yes YesLastobond Shield HT/Pro HT-S Yes No No Yes Yes Yes
Lastobond/Lastobond 195 Yes No No No Yes Yes
Exterior Research and Design,LLC. Evaluation Report s1on1o.0soe-Ry
c=tfica*ofxm*drimtio"*9503 rL25e-Rll
` Revision 9:10/12/2015
Page smr
RIN ` RED
TABLE 1: RooF COVER OpT10Ns
Underlayment Asphalt Nail-On Foam-On Metal Slate
Wood Shakes&
Shingles Tile Tile Shingles
Lastobond ECO /RESISTO
1_131236,Grip-Rite Eave&Valley Yes. No No No Yes Yes
Protector/RESISTO LB1244
Lastobond Smooth Seal HT Yes No No Yes Yes Yes
Yes
Colphene FR GR Yes Yes See 55.1 No Yes Yes
Yes Yes
Unilay(e) Yes Batten Only See 55.1 No No No
5.5.1 "Foam-On Tile" is limited to.use of the following adhesives unless tensile adhesion/ long term aging data
from an.accredited testing laboratory is provided.
Underlayment Adhesive(s)
Lastobond TU HT 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)or Dow Chemical TileBond'l"Roof
Tile Adhesive(FL717)
Colphene FR GR 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
Unilay(e) 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck: .
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HTS, Lastobond TU HT, Lastobond, Lastobond 195,. Lastobond ECO, RESISTO LB1236, Grip-Rite Eave &
Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
> Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D41
primed Southern Yellow Pine;ASTM D41 primed structural concrete.
Colphene FR GR applied to:
r Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
Note:
While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends
priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within
24 hours.
> Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to
installation ofthe self-adhering underlayment.
5.6.2 Bond-to-insulation:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond,. Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave &
Valley Protector, RESISTO L51244, Lastbbond Smooth Seal HT or Colphene FR GR applied to.:
8 Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on tile systems(Lastobond TU HT only), insulation attachment shall be designed by a qualified
design professional and installed based on testing of the insulation/underlayment system in accordance
with FM 4474,Appendix D or TAS 114,Appendix J.
Exterior Research and Design,LLC. Evaluation Report 518010.06.09-R9
Certifrcate ofAuthorizatiob#9503 FL2569-R11
Revision 9.10/12/2015
Page 4 of
� .
. N
5.6.3 Bond to MechanicaliV Attached Base Laver:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave &
Valley Protector,RESISTO LB124.4, Lastobond Smooth Seal HT or Colphene FR GR applied to:
> ASTM D226,Type I or 11 felt;Sopra-G; Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on tile systems (Lastobond TU HT only),
base layer shall be attached in accordance with FRSA/TRI April 2012(04-12)..
.5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on the systems;where
the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-ori the applications.
Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has
already been applied). Refer to FBC 1609 for determination of design wind pressures.
5.6:4.1 Maximum Design Pressure=-45.0 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional) Elastocol Stick or Elastocol 600c
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
5.6.4.2. Maximum Design Pressure=-67.5 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: Elastocol 600c
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
5.6.4.3 Maximum Design Pressure=-60.0 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin
caps(FBC 1517.5.2)spaced 6-inch o.c.at the 4-inch laps and.6-inch o.c.in three,equally
spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered
5.6.4.4 Maximum Design Pressure=-90:0 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Underlayment: Unilay(e) mechanically attached with Soprafix Polymer Batten Bar (PB8) or Soprafix
Metal Batten Bar(MBB) with Soprema#15-EL fasteners spaced 6-inch o.c.within the 5-
inch wide, self-adhering side laps. End laps are 64nch wide and sealed using either
heat-welding or hot-air welding techniques.
5.7 Exposure Limitations:
Lastobond, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236, Grip-Rite Eave & i
Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after installation.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond
Pro HT-S shall not be left exposed for longer than 90-days after installation.
Lastobond TU HT or Colphene FR GR or Unilay(e)shall not be left exposed for longerthan 180-days.after
installation.
Exterior Research and Design,LLC. Evaluation Report 528010:06.09-R9
Certificate of Authorisation#9503 FL2569-RIl
:Revision 9s 10/1212015.
Pages of 7
TRINII ITU
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick or
Elastocol 600c(if applicable).
6.3 Lastobond TU HT Lastobond Shield Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,_Lastobond Shield
HT Lastobond Pro HT-S,Lastobond Lastobond 195 Lastobond Eco.Lastobond Smooth Seal HT,RESISTO
L81236 Grip-Rite Eave&Valley Protector RESISTO LB1244 or Colphene FR GR:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications:
While priming is optional,Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final
roof cover Is not slated for installation within.24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of rel.ease.fiim.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the
membrane tight..Firmly roil the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps
shall be sealed using either heat-welding or hot air welding techniques.
When installing at slopes above 8:12,Soprema recommends back-nailing in the overlap area at the top of
the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction: For valleys,apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foam-on tile applications, reference is made to Section_5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRl April 2012(04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
66.4. Unila e :
6.4.1 Non-Tile Applications or Nail-On,Battened Tile Applications:
Reference is made to Table 1 herein and FRSA/TRI April 2012(04-12) Installation Manual(if applicable).
Apply sheet parallel to the roof edge and, starting at the eave with the selvedge-edge upslope,
mechanically attach the 5-inch wide selvedge-edge to the wood deck with nails and tin caps or round cap-
nails spaced 36-inch o_c. Apply the second course in a water-shedding manner with self-adhering side-
laps. Vigorous hand or motorized roller pressure is applied to the self-adhering laps to ensure a watertight
application.
Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course
below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques.
Exterior Research and Design,LLC. Evaluation Report S18010.06.09-R9
Certificate ofAutharization#9503 FL2569-R11
Revision 9.:10/12/2015
Page 6 of 7
yEL't..�t5 ��•
F ?
Tile(if applicable)shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment:
6.4.2 Foam-On Tile Applications:
Reference is made.to FRSA/TRI April 2012 (04-12) Installation Manual, Table 1 herein and Section 5.6.4.4
herein.
Apply sheet parallel to the roof edge and; starting at the eave with the selvedge-edge upslope,
mechanically,attach the 5-inch wide selvedge-edge-to the wood deck Soprafix Polymer Batten Bar(PBB)or
Soprafix Metal Batten Bar (MBB) with Soprema #15-EL fasteners spaced 6-inch o.c. Apply the second
course in a water-shedding manner with self-adhering side-laps. Vigorous hand or motorized roller
pressure is applied to the self-adhering laps to ensure a watertight application.
Vertical seams should be 6-inches and staggered not less than 24t from vertical seams in the course
below. All over-granule end-laps shall be sealed using either.heat-welding or hot air welding techniques.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to .the
underlayment.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building official or Authority Having Jurisdiction in order to properly evaluate the.installation of
this.product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for information on plants covered under Rule 61620-3 QA
requirements.
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-