HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 4 RECEIVED NOV 15 206 f�t1■� low acts tome Lod In User Registration Hu Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map U.A s Search _ •C J� Busines.��, Product Approval 3 Professional `:l �- USER:Public Usa a j,�t-t,.ttSF iiyfi t JJJJ L,��c Prmittt ticmv3i Mem,> S.-amh>Amncatkm t jct>Application Detail NII f _ y FL# FL1956-1112 `" `T't." '� Application Type Editorial Change Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer TAMKO Building Products,Inc. Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 East 2305 kerri—eden@tamko.com Authorized Signature Kerri Eden kerri—eden@tamko.com Technical Representative Kerri Eden Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri_eden@tamko.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Certification Mark or Listing Certification Agency LIL LLC Validated By Robert J.M.Nieminen,PE J Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 09/17/2015 http://iv,,vw.floridabuildi ng.org/pr/pr_app_dtl.aspx?param=NvGEVXQWtDgs%2fmGFoyT6... 3/23/20.16 Florida Building Code Online Page 2 of 4 Date Validated 10/06/2015 Date Pending FBC Approval Date Approved 10/09/2015 Summar,of Products FL# Model,Number Description or Name 1956.1 Elite Glass-Seal 'A three tab asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 RI l G CAC Tarnko dery Conf FL 1956 2p15,adf HVHZ:No F4.1956 R12 C C,J_q UL [ertincatian 10-11-12.ndf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 R12 II Glass Seal Elite_Gl� s_S•°al 32g in t.pdf Other:Asphalt shingles Verified By:Robert Nieminen 59166 shall be used only on roof Created by Independent Third Party: No slopes of 2:12 or greater. Evaluation Reports Nails must be used as the Created by Independent Third Party: method of attachment. 1956.2 Glass-Seal A three tab asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FU956 R12 C CAC FL1956 RI I C CAC Tamko 5zry Conf FL 1456" 2015.rn;f HVHZ:No ELJ95b P,12 C CAC UL ce trfic�t :10 11,1 Z pelf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A �t,79 6 P_ir 1Ii Cha>s Seal [lit=Glass Seal Apo—,as—t—PW Other:Asphalt shingles Verified By:Robert Nieminen PE 59166 shall be used only on roof Created by Independent Third Party: No slopes of 2:12 or greater. Evaluation Reports Nails must be used as the Created by Independent Third Party: method of attachment. 1956.3 1 Heritage A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in F,1956 F1_C_C�C FI.1_R59Pi�C cAc Z rel q Scry Conf �g '01$,pdf HVHZ:No FL1.955 Fl� C C'.AC UL ce;tihcgtion 10-11•}.2.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A F�1 6 R1 11 HerF .I P_p insk ndf Other:Asphalt shingles FL 1956 r i2 it ht��i[a F 3 st.�clf shall be used only on roof F119S6 RIS_I�}prjt�e T aoo ir1St.DCIf slopes of 2:12 or greater. Verified By:Robert J.M.Nleminen FL 59166 Nails must be used as the Created by Independent Third Party:No method of attachment. Evaluation Reports Created by Independent Third Party: 1956.4 Heritage 30 A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use In FL1956 R12 C CAC FL19Sf, R1k__�j CAC T?mk0 SP.r;!Conf L 1.956 2p15.c_t+f HVHZ:No FL1956 R12 C CAC UL cer*ifx"ntiel[ 10_I1-12.rdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A EL]255 R17_ [I h&r'a g 30 aag in5t ar?ri I . 411 Other:Asphalt shingles E_'-'1_9L56 R32 iI heL't_ag? 30 ap _it�st f apyrl lU. df shall be used only on roof Verified By:Robert Nieminen PE 59166 slopes of 2:12 or greater. Created by Independent Third Party:No Nails must be used as the Evaluation Reports method of attachment. Created by Independent Third Party: 19-915.51 Heritage 50 A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 RI C CAC 1=L=95CRI I_C CAA 'nl oo31erJ Coq FL 1956 ?915. cf HVHZ:No FL1956 R1-1 Ccertifcatigta 10.11-i2.pCll Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 R12 11 t critage 50 a,-r., in4t aprii 10.pdf Other:Asphalt shingles El 1'56 R12 II hcritatle 50 anp in=,t f ar?ril 10.fidf shall be used only an roof Verified By:Robert Nieminen PE 59166 slopes of 2:12 or greater. Created by Independent Third Party: No Nails must be used as the Evaluation Reports method of attachment. Created by Independent Third Party: http:U,.-k,%viv.floridabuilding.org/pr/pr_app_dt1.aspx?param=wGEVYQNN tDgs%2finGFoyT6... 3/23/2016 Florida Building Code Online Page 3 of 4 1956.6 Heritage Premium A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use inLim g56 R]2 C GAC F1-1.956 R11 -CAC CAC Tamko Sen Conf FL 1956 2015,pdf HVHZ:No E1.1g56 R12 C CAC UL certification 10-1.1.12,pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL_�956 R12 Il Heritage Premium D P app inst.odf Other:Asphalt shingles FL1956 R12 II Heritage Premium F app jrjsLpdf shall be used only on roof FL1956 R12 lI Hadtagg Prernium T app inst.pdf slopes of 2:12 or greater. Verified By:Robert Nieminen 59166 Nails must be used as the Created by Independent Third Party:No method of attachment. Evaluation Reports Created by Independent Third Party: 1956.71 Heritage Vintage A heavy weight dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in &J_956_R!2 C CAC FL1956 R11 C CAC Tamko Sery Ck. t FL 1956 201.5.pdf HVHZ:No FL1956 R12 C CkC UL shingle matrix.Ndf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 P,12 if Heritage 1lintape apn inst.pdf Other:Asphalt shingles Verified By:Robert].M.Nieminen PE 59166 shall be used only on roof Created by Independent Third Party:No slopes of 2:12 or greater. Evaluation Reports Nails must be used as the Created by Independent Third Party: method of attachment. 1956.8 Heritage Vintage Hip and ridge shingles 12 X 12 Hip and Ridge Limits of Use Certification Agency Certificate Approved for use in EL1956 R12 C CAC F11956 RI1 C CAC l�amko Ser.,Conf FL 1956 2015.pf HVHZ:No FL1956 R12 C CAC UL sninn le mqlri?(,pdF Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 FIZ 1' TAr°11<0(-) Hpritage«5 t' % 12 Hip and Ridge Application Tnstructions 00f Other:Asphalt shingles Verified By:Robert).M.Nieminen PE 59166 shall be used only on roof Created by Independent Third Party:No slopes of 2:12 or greater. Evaluation Reports Nails must be used as the Created by independent Third Party: method of attachment. 1956.9 Heritage A dimensional asphalt shingle. Woodgate Limits of Use Certification Agency Certificate Approved for use in ELL".5 C FL19S6 R11 C CAC Tamko Ser- HVHZ:No FL1956 R12 C QAC UL certification 10-11-12.odf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09%17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A F-1956 R12 IS Heritage Woodgate D app in-Mpdf Other:Asphalt shingles FI-1.956 R12 SI Heritage Woodn ate F app inst.odf shall be used only on roof Verified By:Robert Nieminen 59166 slopes of 2:12 or greater. Created by Independent Third Party:No Nails must be used as the Evaluation Reports method of attachment. Created by Independent Third Party: 1956.10 Heritage XL A dimensional asphalt shingle. Limits of Use . Certification Agency Certificate Approved for use in FI9S�R.2 C AC FL1956_.B.l1_Q-CAC Tamko Sery C �FL_1p56 201S.Fr HVHZ:No FL1956 R1.2 C CAC UL eertifieafion 10- 1-12.pof Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 R12 11 heritage xl app inst d april 10.odf Other:Asphalt shingles FL1956 R12 I[ herita4e xi app inst f aRril 10.pdf shall be used only on roof Verified By:Robert Nieminen PE 59166 slopes of 2:12 or greater. Created by Independent,Third Party: No Nails must be used as the Evaluation Reports method of attachment. Created by Independent Third Party: 1956.11 Hip and Ridge Hip and ridge shingles [Shingles Limits of Use. Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 Ri C CAC_ mko Sery CMiff`_EL 5.pdf HVHZ:No FL1956 R12 C C.AC UL certification 10-11 12.pdf http://w,%v%v:floridabuilding.org/pr/pr_app_dtl.aspx?pa-ram=wGEVXQwtDgs%2finGFoyT6... 3/23/2016 Florida Building Code Online Page 4 of 4 Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 'Impact Resistant:N/A Installation Instructions Design Pressure:N/A ?? 6_3.1 .It_��Sb�? HiQ�. fn.i Radf Other:Hip and Ridge El_LIJ5& R12 11_12 xl _)_ii RidtLg,ACpticatiun SnstlitCttans.pdf shingles shall be used only FL1956 R12 It 12-1-4x:12 HID id a Sealant Dab tlilllustration .adf on roof slopes of 2:12 or FLI.956 R12 iI 12x12 HipR.icloe Sealant Dab IllustrAdoa ,dff greater.Nails must be used Verified By:Robert Nieminen 59166 as the method of Created by Independent Third Party:No attachment. Evaluation Reports Created by Independent Third Party: Oa.:k Nest Contact Us::1940 North Monroe Street,Tallahassee FL 32399 phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007.2013 State of Flor.d tom,::Pjvan.Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records,If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,pease contact 850.487.1395.•pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.if you do not wish to supply a personal address,please provldethe Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please dick h-- Product Iry.Product AAppprrovaf Adepts: Nl'llrll l'�:'t:c,t'•: http://,svww.floridabuilding.org/pr/pr_app dtl.as.pY?param=wGEVX'QwtDgs%2fmGFoyT6... 3/2312016 Application Instructions for TAMK01 HERITAGE& 30 BUIir,DING PRODUCTS 6.111NATBD ASPHALT SNiNGUS Dallas, TX e Tuscaloosa,AL a Phillipsburg, K&9 Joplin, MO THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS,INC.ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING FROM FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS. THIS PRODUCT IS COVERED BY A LIMITED WARRANTY,THE TERMS OF WHICH ARE PRINTED ON.THE WRAPPER. IN COLD WEATHER(BELOW 40°F),CARE MUST BE TAKEN TO AVOID DAMAGE TO THE EDGES AND CORNERS OF THE SHINGLES. IMPORTANT.It is not necessary to remove the plastic strip from the back of the shingles. 1.ROOF BECK &FASTENERS These shingles are for application to roof decks capable of receiving WIND CAUTION: Extreme wind velocities can damage these and retaining fasteners,and to inclines of not less than in.per foot shingles after application when proper sealing of the shingles For roofs having pitches 2 in.per foot to less than 4 in_per foot,refer does not occur.This can especially be a problem if the shingles to special instructions titled"Low Slope Application".Shingles must are applied in cooler months or in areas on the roof that do not be applied properly,TAMKO assumes no responsibility for leaks or receive direct sunlight. These conditions may impede the sealing defects resulting from improper application,or failure to properly of the adhesive strips on the.shingles.The inability to seal down prepare the surface to be rooted over. may be.compounded by prolonged cold weather conditions and/ NEW ROOF DECK CONSTRUCTION:Roof deck must be smooth, or blowing dust.In these situations,hand sealing of the shingles is dry and free from warped surfaces.It is recommended that metal recommended.To insure immediate sealing,apply 4 quarter-sized drip edges be installed at eaves and rakes. dabs of TAM-PROF Premium.SBS Adhesive or TAMKO Tam-Seal Adhesive on the back of the shingle 1 in.(25mm)and 13 in.(330mm) PLYWOOD:All plywood shall be exterior grade as defined by the in from each side and 1 in, (25mm) up from the bottom of the Engineered.Wood Association.Plywood shall be a minimum of 3/8 shingle.Press shingle firmly into the adhesive.For ma)dmum wind in.thickness and applied in accordance with the recommendations resistance along rakes;cement shingles to the underlayment and of the Engineered Wood Association. each other in a 4 in.(.102mm)width of TAM-PRO SBS Adhesive or SHEATHiNG.BOAROS:'Boards shall be well-seasoned tongue- TAMKO Tam-Seat Adhesive.Caution:Apply ONLY a thin unifonr and-groove boards and not over 6 in.nominal width.Boards shall layer of adhesive less than 1/8 in.(3mm)thick.Excessive amounts be a 1 in. nominal minimum thickness. Boards shall be properly can cause blistering of the shingles and may soften the asphalt in spaced and nailed. certain underlayments resulting in the asphalt flowing,dripping and staining.Shingles must also be fastened according to the fastening 2.VENTILATION instructions described below. Inadequate ventilation of attic spaces can cause accumulation of Correct placement of the fasteners is critical to,the performance moisture in winter months and a build up of heat in the summer. of the shingle. if.the fasteners are not placed as shown in the These conditions can lead to: diagram and described below,this will result in the termination of TAMKO's liabilities under the limited warranty.TAMKO will not be 1.Vapor Condensation responsible for damage to shingles caused by winds in excess of 2.Buckling of shingles due to deck movement. the applicable mph as stated in the limited warranty.See limited 3.Rotting of wood members. warranty for details. FASTENING PATTERNS:Fasteners must be placed 6-1/8 in.from 4.Premature failure of roof, the bottom edge of the shingle, penetrating through the common To insure adequate ventilation and circulation of air,place louvers bond,and located horizontally as follows: of sufficient size high in the gable ends and/or Instal)continuous 1)Standard Fastening Pattem.(For use on decks with slopes 2 in. ridge and soffit vents. FHA minimum property standards requite per foot to 21 in,per foot.)One fastener 1 in,back from each end one square foot of net free ventilation area to each 150 square feet and one 13-1/2 in.back from each end of the sh;ngle for a total of 4 of space to be vented,or one square foot per 300 square feet if a fasteners.(See standard fastening pattern illustrated below). vapor barrier is installed on the warm side of the•ceiling or if at least one half of the ventilation is provided near the ridge.If the ventilation STANDARD FASTENING PATTERN openings are screened,the total area should be doubled. FASTENERS NAILZONE COMMON BOND 11 IS PARTICULARLY IMPORTANT TO PROVIDE ADEQUATE VENTILATION. s-1I8" EXPosuREs-s>e^ 1"►� �- 12-1/2"-+{a- 12-3/8" 12-1/V-- �-1" (Continued) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11109 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800=368-2055 Southeast District 2300 35th St.; Tuscaloosa,AL 35401 800-228-2656 tamko.COt11 Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave.. Denver.CO 80216 800-530-8868 1 a (CONTINUED from page 1) ITAIR&OJ HERITAGE0 Ro BUILt11NG PROt1UC't'G URINATED ASPHALT°SHINGLES Dallas, TX • Tuscaloosa, AL 6 Phillipsburg, KS • Joplin, MO 2) Mansard Fastening Pattern. (For use on decks with slopes be a minimum of 1-1/4 in,for new construction and 1-1/2 in. for greater than 21 in.per foot.)One fastener 1 In,back from each end reroofing thus allowing a minimum deck penetration of 3/4in.The and one fastener 8-1/2 in.back from each end and one fastener 16 crown of.the staple must be parallel to the length of the shingle. in.back from each end for a total of 6 fasteners per shingle. (See The staple crown should be driven flush with the shingle surface. Mansard and High Wind Fastening Pattern illustrated below.) Staples that are crooked,underdriven or overdriven are considered MANSARD AND HIGH WIND FASTENING PATTERN improperly applied. FASTENERS NAIL ZONE Property Driven Improperly Driven COMMON uneLr&rven mvwdrrven crooked DOND ��►I _risQhall . _ 'SIIinP�s 6"L F SURE 5-SM" _-•i \ 62tking . ��{ Iia-trr�r{.-z-trz•�{�-�-a+o�+}�_T-in"-►;.-�-trz°-H fit" 3) High Wind Fastening Pattern. (For High Wind Application QAka QN;ALL FASTENERS MUST BE DRIVEN INTO THE NAIL requirements)One fastener 1 In.back from each end.One fastener ZONE/COMMON BOND AS SHOWN IN THE DIAGRAM ABOVE. 8-1/2 in.back from each end and one fastener 16 in.back from each 4.UNDERL'AYNCHT end fora total of six(6)fasteners per shingle.In addition to this shingle fastening pattern requirement.for High Wind Application,TAMKO UNDERLAYMENT:An underlayment consisting of asphalt saturated also requires the use of the following TAMKO products: TAMKO felt must be applied over the entire deck before the installation'of felts or underlayments;TAMKO.Moisture Guard Plus underlayment TAMKO shingles.Failure'fo add underlayment can cause premature at all eaves,rakes,and valleys;TAMKO or TAM-PRO cements and failure of the shingles which is not covered by TAMKO's limited coatings products where required;TAMKO ventilation where required, warranty.Apply the felt when the deck is dry.On roof decks 4 in. TAMKO starter shingles if available in area,and TAMKO Hip and Ridge per foot and greater apply the felt parallel to the eaves lapping each- . shingles installed on all hips and ridges.Along rakes,cement shingles course of the felt'over the lower course at least 2 in.Where ends to the underlayment and each other in a 4 in.(102 mm)width of TAM join, lap the felt 4 in. If left exposed. the underlayment.telt may PRO SBS Adhesive or TAMKO Tam-Seal Adhesive.Also,see local be adversely affected by moisture and weathering. Laying of the building codes for proper nailing application.High Wind Application underlayment and the shingle application must be done together. is offered on new construction or complete tear-off applications only, products which are acceptable for use as underlayment are: It is not offered for recover applications.If High Wind Application requirements are not followed,the High Wind Application Warranty - TAMKO No.15 Asphalt Saturated Organic Felt MPH, as stated on Table I in the Limited Warranty, reverts to the - Anon-perforated asphalt saturated organic felt which meets Standard Application Wind Warranty MPH limit.(See Mansard and ASTM:D226,Type I or ASTM D4869,Type I High Wind Fastening Pattern Illustrated above.) - Any TAMKO non perforated asphalt saturated organic felt NAILS:TAMKO recommends the use of nails as the preferred method - TAMKO TW Metal and Tile Underlayment,TW Underlayment Of application. Standard and Moisture Guard Plus"(additional ventilation may be pp type roofing nails should be used. Nail required.Contact TAMKO's Technical Services Department shanks should be made of minimum 12 gauge wire,and a minimum head diameter of 3/8 in.Nails should be long.enough to penetrate for more information.) 3/4 in,into the roof deck.Where the deck is less than'314 in.thick, In areas where ice builds up along the eaves or a back-up of water the nails should be long enough to penetrate completely through, from frozen or clogged gutters is a potential problem,TAMKO's plywood decking and extend at least 1/8 in.through the roof deck. Moisture Guard PluO waterproofing underlayment(or any specialty Drive nail head flush with the shingle surface. eaves flashing product) may be applied to eaves, rakes, ridges, valleys, around chimneys, skylights or dormers to help prevent prop'(_).wty f mn `mp0�riyDr1va3+8"min dlometn unmrddvrn overdrlvan crmkM water damage.Contact TAMKO's Technical Services Department for more information. — _ Asphalt � SM-914_ TAMKO does not recommend the use of any substitute products ON PEA, . �Nr*g as shingle underlayment. S.APPLICATION INSTRUC' ONS slra+9ht,goad Pr ft.".. tn.6equete tin deep.CIOs Inedett.�ste . - red ttueb 61th shfrtgfa curfew pon,YSiet»,t .+dnytd nrx+var�a. START _ CODU�SE:Astarter course may consist of TAMKO Shingle. Starter,self-sealing 3-fab shingles or a 9 inch wide strip of mineral STAPLES:If staples are used.in the attaching.process, follow the surface roll roofing.If self-sealing 3-tab shingles are used,remove above instructions for placement.All staples must be driven with the exposed tab portion and install with the factory applied adhesive pneumatic staplers.The staple must meet the following minimum adjacent to the eaves. Attach the starter course with approved dimensional requirements.Staples must be made froma minimum fasteners along a line parallel to and 3 in,to 4 in.above the eaves 16 gauge galvanized wire.Crown width must be at least 15/16 In. edge.The starter course should overhang both the eaves and rake (staple crown width is measured outside the legs).Leg length should edges 114 in.to 3/8 in. (Continued) Central District 220 West 4th St., Joplin,MO 64801 800,641-4691 ;troy Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800443-1834 NFL„ q� h Western District 5300 East 43rd Ave Denver CO 80216 800-530-6868 (CONTINUED from page 2) TAMKO HERITAGE® 30 BUILDING PRODOCTS 6AMINATED ASPHA6T SHiNG6CS . Dallas, TX •Tuscaloosa, AL • Phillipsburg, KS • Joplin, MO SHINGLE APPLICATION;Start the first course with a full:size shingle S.LOW SLOPE APPI61CATiON and overhang the rake edge 1/4 in.Cut 10-3/8 in.from afull shingle On pitches 2In.per toot to4 in.per f oot cover the deck with two layers to form a shingle 29 in.long.Use this to start the second course(see of asphalt saturated fell.Begin by applying the felt in a 19 in.widestrip diagram below).Cut a 23 in.long shingle to start the third course.Use along the eaves and overhanging the drip edge by 1/4 to 3/4 in.Place the remaining 16-3/8 in.piece of shingle to start the fourth course and a full"36 in,wide sheet over the 19 in.wide starter piece,completely use the remaining 10-3/8 in.piece to begin the fifth course.Continue overlapping it.All succeeding courses will be positioned to overlap the up the yake in as many rows as necessary using the same formula preceding course by 19 in..lf winter temperatures average 25°F or less, as outlined above.The butt of the shingle should be aligned with thoroughly cement the felts to each other with TAM-PRO or TAMKO the top edge of the.sawtooth of the underlying shingle for a 5-5/8 in. plastic Roof Cement from eaves and rakes to a.point of a least 24 in. exposure.(see shingle application drawing illustrated on this.panel). inside the interior wall line of the building.As an alternative,TAMKO's When you_make your final cut at the roof's edge,flip any pieces that Moisture Guard Plus"self-adhering waterproofing underiayment may are 8 in,or longer back onto the roof.These pieces can be worked be used in lieu of the cemented felts. in anywhere without creating zippers or color variations. NOTE;Do not align joints of shingle courses when working in cut 7'MAlISi1RD ROOF OR STEEP SLOPE ROOF pieces.Joints should be no closer than 4 in.from one another. If the slopeexeeeds2l in.perfoot(60),each shingle mustbe sealed with TAM-PRO SBS Adhesive or TAMKO Tam-Seal Adhesive immediately upon installation.Spots of cement must be equivalent in size to a$.25 piece and applied to shingles with a 5-5/8 in.exposure,use 6 fasteners 10,31&^ per shingle.See Section 3 for the Mansard Fastening Pattern. 8.111"O0'FiN11; repent courrs" i6-318^ 10-31V 2g^ Before re-rooting,be certain to inspect the roof decks.All plywood shall meet the requirements listed in Section 1. 8" Nail down or remove curled or broken shingles from the existing 16.318. 6.318 roof.Replace ail missing shingles with new ones to provide a smooth eke Pulp. base, Shingles that are buckled usually indicate warped decking l 10-318' or protruding nails. Hammer down all protruding nails.or remove 5th course them and refasten In a new location. Remove all drip edge metal - 23" 18318" and replace with new. dth course If re-roofing over an.existing root where new flashing is required 3rd course 3^ toprotect against ice dams(freeze/thaw cycle of water and/or.the. 2nd course 0-9" backup of water in frozen orclogged gutters),remove the old roofing 29 to a point at least 24 in. beyond the interior wail line and apply lst co""' ,.'Fun 10-3/8^ TAMKO's Moisture Guard Plus'waterproofing underlayment_Contact OeYe TAMKO's Technical Services Department for more information. Measurements will vary when nesting over an existing 5 in.exposure single.roof.Call TAMKO Technical Services for further information. -L Cut i-,i'el_6a*Nk m".19*.'a.to e W01 Cat. VIQW -1i. The nesting procedure described below is the preferred method for a re a'a•term �-- w reroofing over existing metric size shingles with a 5-5/8 in.exposure: See description below: @r_CouMg:Remove the tabs and an additional portion from the head of a.fuli size shingle so that its height is equal to the exposure of the existing shingles.Position the resulting strip over the existing roof edge'(with the factory-applied adhesive strip along the eaves). Cut approximately 6 in.from the rake end and apply the remaining portion at the eaves.Continue the starter strip by applying full length shingle strips cut to height as above,evenly along the existing root at the eaves.The existing roof should overhang the eaves far •f Es tats. s�.ai,m'n'ul4�,rJ,s:c�ya '� „�,uorw,�•.v.lea+e-a�a,o��r:rr�, enough to carry water off Into the gutter.If this is not the case, amn n, arnprc^9 SRngb3>un My ata cut andapply the starter strip so that it will provide sufficient overhang for proper drainage. ° ° "`�"� "''�'"`'"°`� " "'" ""` " Firs Core•Remove an amount from the butt ed a of a full-size 3.h^m ria .mer, i x�,rvr .r nv m.,R',i 4x:;r ��_U e 9 .a' ^'^°^r.ter°K"hw= shingle so that the remairiing portion of the shingle fits between the r:.n?w+,z,t�-ria ccC va^a:ton. " �^����aar•a• e. �.^•^ *m0^ butts of the existing third course_This course must also be applied cur pieces.Jol"shautd ho ro eJosa,than 4•from onn mother. evenly along the eaves edge of the new starter strip. (Continued) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 �vos Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 . 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamkoxom SouthwestDistrict 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 3 Id, (CONTINUED from page 3) MTAMK BERITAGW 30 89I6DING PRODUCTS 6AMINATE® ASPHA6T SHING16ES Dallas, TX ®Tuscaloosa, AL • Phillipsburg, KS • Joplin, MO Second and Succeeding Courses: Remove 10-3/8 in. from the FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE rake end of the first shingle In the second course, and continue CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT, with full width shingles for the remainder of the course, placing the top edge of each new shingle against the butt edge of the old shingle in the course above.This method should create an exposure of Nua Fast W.<l,- 1 G—d Flus a sa lo. [xL a u9d ii of 5-5/8 in.after the first course.When beginning the succeeding - mxtar my courses continue to follow the Heritage application instructions. (See section 5). '� ,• �,�°ter Existing _ \•�/ Ur+:r Liymer;t ��`��_ t:c•tavenara w'ithm r n;+ Dnpedge%•f ..i ',� \, 'hn v�tic•I slR.,�>.2 wd—bash Y<' Drip edge Gcm:nf2Y centen: ural cc a no New shingles ` `•`t �}` ,fir' = ma vvrtiu-'d u!dn,-`e. 5 5/8"exposure ID.HIP AND BILGE FASTENING DC'AIL exposure ,- Apply the shingles with a 5 in,exposure beginning at the bottom i of the hip or from the end of the ridge opposite the direction of the 9.VALLEY APPLICATION prevailing winds.Secure each shingle with one fastener on each side, 5-112 in.back from the exposed end and 1 in.up from the edge. Over the shingle underlayment,center minimum 36 in.wide sheet TAMKO recommends the use of TAMKO Hip 8 Ridge shingle of TAMKO Nail-Fast,Moisture Guard Plus"or a minimum 50 lb.roll products.Where matching colors are available,it is acceptable to roofing in the valley.Nail the felt only where necessary to hold it in place and then only nail the outside edges. use TAMKO's Elite Glass-Seal shingles cut down to 12 in.pieces. IMPORTANT*PRIOR TO INSTALLATION WARM SHINGLES TO Fasteners should be 1;4 in.longer than the one used for shingles PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING IMPORTANT: PRIOR TO INSTALLATION, CARE NEEDS TO BE SHINGLES TO FORM VALLEY. TAKEN TO PREVENT DAMAGE WHICH CAN OCCUR WHILE After valley flashing is in place: BENDING SHINGLE IN COLD WEATHER. • Apply the first course of shingles along the eaves of one of the Direction of prevailing wind intersecting roof planes and across the valley. Start 5•exposure here-- Note:For proper flow of water over the trimmed shingle,always start applying the shingles on the roof plane that has the lower 6 '; �. EFastener slope or less height. ,"i—n{" � `L,'`;_,-�5.f�2� • Extend the end shingle at least 12 in.onto the adjoining roof. Ili start Apply succeeding courses in the same manner,extending them -" - here 5°exposure across the valley and onto the adjoining root. • Press the shingles tightly into the valley. THESE ARE THE MANUFACTURER'S APPLICATION • Use normal shingle fastening methods. INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC.ASSUMES Note:No fastener should be within 6 in.of the valley centerline, NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING and two fasteners should be placed at the end of each shingle DEFECTS RESULTING FROM FAILURE TO FOLLOW THE crossing the valley. MANUFACTURER'S INSTRUCTIONS. • To the adjoining roof plane,apply one row of shingles vertically facing the valley and 2 in.back from the valley centerline. Note: For a neater installation, snaphalklithe TA K01i;,Moisture Guard Plus?,Nail Fastfl,TAM-PRO+0 and Heritag-eD are registered a cne over shingles for guidance. trademarks of TAMKO Building Products.Inc- Intormatlon included in these application instructions was current at time of pnnLrg,To • To complete the valley, apply shingles on the adjoining roof obtain a copy of the mast current version of these application instructions,visit us online plane by positioning the tip of the first shingle of each row at at tamko.com or call us at 800-641-4691. the 2 In,point from the centerline where the edge of the vertical shingle has been applied,covering the vertical shingle. Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11/09 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St„ Tuscaloosa,AL 35401 800-228-2656 tamko.c®m Southwest District 7910 S.Central Exp., Dallas.TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 i,