HomeMy WebLinkAboutEngineering T1 EMU R IGHT
1918 Corporate Drive
WID 'O W S Boynton Beach,FL 33426
NPh.561-922-6747
Fax.561-292-3562
Property Information Building Information
Owner: Kevin or Kathleen Purssing Wind Zone: 175 MPH.
Address: 5413 sunset blvd Exposure Category: D
Fort Pierce,FL 34982 Minimum Building Dimension: 27 ft.
Mean Roof Height: 21 ft.
Risk Category: 11
Design Pressure Calculations
Opening Location Device JDevice Device Max Positive Max Negative
Number Zone Width(in) Height(in). Elevation(ft) Pressure(ps; Pressure(psf)
I Int 48 47 7 50.0 -54.4
-- --..............--- — -----—---..-.-_._............_................-----..................................................----_............ ---- _............_..– -------- -----..................
..-- --- -- —
2 Int 48 47 7 50.0 -54.4
3 Int 31 61 7 50.6 -55.0
4 Int 31 61 7 50.6 -55.0
St. Lucie C:oi;n y; FL
Prepared in accordance ivith:ASCE 7-10.Chapter 30. Wind Loads-Components and Cladding.5th Edition(2014)Florida Building Code.
Page 1 of 1
WINDOW & DOOR OPENING INFORMATION
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Corner Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS
NUMBER or Interior OR DOOR TYPE NUMBER (+)PSF (-)PSF (+)PSF (-)PSF TESTED DIMENSIONS MULLION REQ Y/N
SIZE REQ Y/N/NA
1 Int W 7/8"Lami IG 15-0618.03 55 55 50 54.4 74X63 48x47 N N
2 Int W 7/6°LamilG 15-0618.03 55 55 50 54.4 74X63 48x47 N N
3 Int W 7/B"Lam IG 15-0618.02 55 55 50.6 55.0 53X77 31x61 Y N
4 Int W 78"LwniIG 15-0618.02 55 55 50.6 55.0 53X77 31x61 Y N
E
►11 �
;u