HomeMy WebLinkAboutProduct Approval (2) r EXTERIOR RESEARCH&DESIGN, I.I.C. Certificate of Authorization#9503 QOTRINITY ERD � 353 CHRISTIAN STREET, UNIT#13 F.10`ECEIVED OXFORD, CT 06478 PHONE: (203) 262-9245 NOV 2 2 2016 FAX: (203) 262-9243 EVALUATION REPORT Polyglass USA, Inc. St. Lucie County,FL Evaluation Report P12060.02.09-R20 150 Lyon Drive FL5259-R24 Fernley, NV 98408 Date of Issuance:02/24/2009 Revision 20:07/22/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 12. Prepared by: The facsimile seal appearing was authorized by Robert Nieminen, P.E.on 07/22/2015. This does not serve as an electronically Robert J.M. Nieminen,P.E. .; ••.; t,•+ _ signed document. Signed,sealed hardcopies have been Florida Registration No.59166,Florida DCA ANE1983 ;0�l • transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. QOTRINITYIERD' ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Uplift FM 4474 2004 1504.6 Accelerated Weathering ASTM G154 2006 1504.6 Accelerated Weathering ASTM G155 2005 1507.2.3,1507.3.3,1507.5.3,1507.7.3, Physical Properties ASTM D226 2006 1507.8.3,1507.9.3 1507.2.4,1507.2.9.2,1507.5.3,1507.7.3 Physical Properties ASTM D1970 2009 1507.11.2 Physical Properties ASTM D6164 2005 1507.11.2 Physical Properties ASTM D6222 2008 1507.3.3 Installation Practice FRSA/TRI April 2012 2012 1523.6.5.2.1 Physical Properties TAS 103 1995 3. REFERENCES: Entity Examination Reference Date FM Approvals(TST 1867) Wind Uplift 3004091 01/12/2000 PRI(TST 5878) Physical Properties PRI01111 04/08/2002 PRI(TST 5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI(TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI(TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI(TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI(TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI(TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI(TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI(TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI(TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI(TST 5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI(TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI(TST 5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI(TST 5878) Physical Properties PUSA-088-02-01 07/29/2009 MTI(TST 2508) Physical Properties JX20H7A 04/01/2008 MTI(TST 2508) Physical Properties RX14E8A 01/29/2009 ERD(TST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD(TST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD(TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD(TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD(TST 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD(TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD(TST 6049) Physical Properties P13450.08.09 08/13/2009 ERD(TST 6049) Wind Uplift P30540.11.09-R1 11/30/2009 ERD(TST 6049) Physical Properties P11030.11.09-1 11/30/2009 ERD(TST 6049) Wind Uplift P11030.11.09-2 11/30/2009 ERD(TST 6049) Physical Properties P11030.11.09-3 11/30/2009 ERD(TST 6049) Physical Properties P33360.06.10 06/25/2010 ERD(TST 6049) Physical Properties P33370.03.11 03/02/2011 Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20 Certificate of Authorization 119503 FL5259-R24 Revision 20:07/22/2015 Page 2 of 12 QOTRINITYIERD Entity Examination Reference Date ERD(TST 6049) Physical Properties P33370.04.11 04/26/2011 ERD(TST 6049) Physical Properties P37300.10.11 10/19/2011 ERD(TST 6049) Physical Properties P40390.08.12-1 08/06/2012 ERD(TST 6049) Physical Properties P40390.08.12-2 08/07/2012 ERD(TST 6049) Physical Properties C41420.09.12-3 09/11/2012 ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013 ERD(TST 6049) Physical Properties P45370.04.13 04/26/2013 ERD(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013 ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013 ERD(TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013 ERD(TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013 ERD(TST 6049) Physical Properties P45270.05.14 05/12/2014 ERD(TST 6049) Physical Properties 6020.07.14-1 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-2 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-3 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-4 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-5 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-6 09/08/2014 ERD(TST 6049) Physical Properties P46520.10.14 10/03/2014 ERD(TST 6049) Physical Properties P44360.10.14 10/07/2014 ERD(TST 6049) Physical Properties P43290.10.14 10/17/2014 ERD(TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015 ERD(TST 6049) Physical Properties P40390.04.15 04/03/2015 ERD(TST 6049) Wind Uplift PLYG-SC8905.15 07/22/2015 ICC-ES(EVL 2396) IBC Compliance ESR-1697 11/01/2014 Miami-Dade(CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015 Polyglass USA Manufacturing Affidavit Products Current 02/18/2009 Polyglass USA PA Affidavit Mule-Hide Cross Ltg 03/01/2008 Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011 UL,LLC.(QUA9625) Quality Control Service Confirmation,R14571 Exp.08/08/2015 UL,LLC.(QUA9625) Quality Control Service Confirmation,MTS PLUS Exp.07/01/2017 4. PRODUCT DESCRIPTION: 4.1 Mechanically Fastened Underlayments: 4.1.1 Elastobase is a fiberglass reinforced,SBS modified bitumen base sheet. 4.1.2 Elastobase P is a polyester-reinforced,SBS modified bitumen base sheet. 4.2 Self-Adhering Underlavments: 4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with polyolefinic film surface;meets ASTM D1970 and TAS 103. 4.2.2 Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with poly-film surface;meets TAS 103. 4.2.3 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. 4.2.4 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103. 4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane,glass-fiber/polyester reinforced, with a granular surface;meets ASTM D1970 and TAS 103. 4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester fabric surface; meets ASTM D1970 and TAS 103. Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-1120 Certificate of Authorization#9503 F1.5259-1124 Revision 20:07/22/2015 Page 3 of 12 Q0TP'uN1TYJERD 4.2.7 Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (FR) are polyester reinforced,APP modified bitumen cap sheets; meet ASTM D6222. 4.2.8 Polystick Dual PrOTM is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polyester fabric surface;meets ASTM D1970. 4.2.9 Polystick Tile PrOTM is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polyester fabric surface; meets ASTM D1970 and TAS 103. 4.3 Mechanically Fastened and/or Bonded Underlayments: 4.3.1 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced,SBS modified bitumen cap sheets; meet ASTM D6164. 4.3.2 Polyflex G and Polyflex G FR are polyester reinforced,APP modified bitumen cap sheets;meet ASTM D6222. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS Underlayment Asphalt Shingles Nail-On Tile Foam-On Tile Metal wood Shakes& Slate Shingles Yes Yes Elastobase Yes (base layer in 2-ply (base layer in 2-ply Yes Yes Yes system) system) Yes Yes Elastobase P Yes (base layer in 2-ply (base layer in 2-ply Yes Yes Yes system) system) Polystick MTS Yes Yes No Yes Yes Yes Polystick MTS PLUS Yes Yes No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes Polystick TU P Yes Yes Yes No Yes Yes See 5.5.1 Polystick TU Plus Yes Yes Yes Yes Yes Yes See 5.5.1 Polystick TU Max No Yes Yes Yes No No See 5.5.1 Polystick Dual Pro Yes Yes No Yes Yes Yes Polystick Tile Pro Yes Yes Yes Yes Yes Yes See 5.5.1 Elastoflex S6 G Yes Yes Yes No Yes Yes See 5.5.1 Elastoflex S6 G FR Yes Yes No No Yes Yes Polyflex G Yes Yes Yes No Yes Yes See 5.5.1 Polyflex G FR Yes Yes No No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes No Yes Yes See 5.5.1 Mule-Hide SA-APP Cap Sheet Yes Yes Yes No Yes Yes or SA-APP Cap Sheet(FR) See 5.5.1 Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-1120 Certificate of Authorization#9503 F1.5259-1124 Revision 20:07/22/2015 Page 4 of 12 QO TRINITY I ERD 5.5.1 "Foam-On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. ✓ 3MTm 2-Component Roof Tile Adhesive AH-160 FL6332 : Polystick TU P, Polystick TU Plus, Polystick TU Max, p ( ) Y Y Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR)or Tile Pro. ✓ 3M'"' Foam Roof Tile Adhesive RTA-1(FL6276): Polystick TU P, Polystick TU Plus, Polystick TU Max, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR) or Tile Pro ✓ Dow TileBond(FL717): Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro ✓ Convenience Products'Touch 'n Seal StormBond Roof Tile Adhesive (FL14506): Polystick TU Plus, Polystick TU Max 5.6 Allowable Substrates: 5.6.1 Direct-Bond to Deck: Polystick(all variations), Dual Pro,Tile Pro, Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)self-adhered to: ➢ New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood;ASTM D41 primed existing plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex S6 G or S6 G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or G FR torch-applied to: ➢ ASTM D41 primed structural concrete. 5.6.2 Bond-to-Insulation: Polystick (all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR) self-adhered to: ➢ ASTM C1289, Type Il, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard; Dens Deck Prime;or SECUROCK Gypsum-Fiber Roof Board. Elastoflex S6 G or S6 G FR in hot asphalt to: ➢ Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board. Polyflex G or G FR torch-applied to: ➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FBC Section 1504.3.1. Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-1120 Certificate of Authorization#9503 FL5259-1124 Revision 20:07/22/2015 Page 5 of 12 QOTRINITYIERD 5.6.3 Bond to Mechanically Attached Base Laver: Polystick (all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self-adhered to: ➢ ASTM D226,Type I or II felt; Elastobase; Elastobase P or Mule-Hide Nail Base. Elastoflex S6 G or S6 G FR in hot asphalt to: ➢ ASTM D226,Type I or II felt; Elastobase; Elastobase P or Mule-Hide Nail Base. Polyflex G or G FR torch-applied to: ➢ Elastobase; Elastobase P or Mule-Hide Nail Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12),Appendix A,Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC Section 1504.3.1. 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04- 12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads. 5.6.4.1 Maximum Design Pressure=-90 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional)PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus, Polystick TU Max, Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. 5.6.4.2 Maximum Design Pressure=-135 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional)PG100 or ASTM D41 Joints: Min.4-inch wide strips of Elastoflex SA-V over all plywood joints. Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. 5.6.4.3 Maximum Design Pressure=-315 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max,Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. 5.6.4.4 Maximum Design Pressure=-622.5 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: PG100 or ASTM D41 Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.5 Maximum Design Pressure=-30.0 psf*. Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus, Polystick TU Max, Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20 Certificate of Authorization#9503 F1.5259-1124 Revision 20:07/22/2015 Page 6 of 12 QOTRINITYIERD 5.6.4.6 Maximum Design Pressure=-37.5 psf*. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus, Polystick TU Max, Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. 5.6.4.7 Maximum Design Pressure=-37.5 psf*. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: One(1)or two(2)layers ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt. 5.6.4.8 Maximum Design Pressure=-45 psf*. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: One(1)layer ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus, Polystick TU Max, Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex S6 G,applied in full mopping of hot asphalt. 5.6.4.9 Maximum Design Pressure=-45 psf*. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Two(2)layers ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus, Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex S6 G,applied in full mopping of hot asphalt. 5.6.4.10 Maximum Design Pressure=-45 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.11 Maximum Design Pressure=-52.5 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.12 Maximum Design Pressure=-52.5 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max, Polyflex SAP, Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. Exterior Research and Design,LLC. Evaluation Report P12060.02.09-1120 Certificate of Authorization#9503 FL5259-R24 Revision 20:07/22/2015 Page 7 of 12 QOTRINITYIERD 5.6.4.13 Maximum Design Pressure=-52.5 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.14 Maximum Design Pressure=-60 psf. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.15 Maximum Design Pressure=-60 psf. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.16 Maximum Design Pressure=-90 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.17 Maximum Design Pressure=-90 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.18 Maximum Design Pressure=-90 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt. 5.6.4.19 Maximum Design Pressure=-97.5 psf. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c.at the 4-inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max, Polyflex SAP, Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. 5.6.4.20 Maximum Design Pressure=-105 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20 Certificate of Authorization#9503 FL5259-R24 Revision 20:07/22/2015 Page 8 of 12 QOTwN1TYJERD 5.6.4.21 Maximum Design Pressure=-112.5 psf. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer at all tin-caps Base Ply: Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. 5.6.4.22 Maximum Design Pressure=-120 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: CMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.23 Maximum Design Pressure=-120 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt. 5.6.4.24 All other direct-deck, adhered Polyglass underlayment systems beneath foam-on tile systems carry a Maximum Design Pressure of-45 psf. 5.6.4.25 For mechanically attached base sheet in a 2-ply system,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design.pressure determined in accordance with FRSA/TRI April 2012 (04-12),Appendix A, Table 1A or FBC 1609. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117, FM LPDS 1-29 and ANSI/SPRI WD1. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 5.7 Exposure Limitations: Elastobase or Elastobase P shall not be left exposed for longer than 30-days after installation. Polystick IR-Xe shall not be left exposed for longer than 90-days after installation. Polystick MTS, MTS PLUS,TU P, TU Plus,TU Max, Dual Pro or Tile Pro shall not be left exposed for longer than 180- days after installation. Polyflex SAP or SAP FR, or Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive-set tile, in which case the maximum exposure is 30 days. Elastoflex S6 G or S6 G FR or Polyflex G or G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive-set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure is 180 days. Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20 Certificate of Authorization#9503 FL5259-R24 Revision 20:07/22/2015 Page 9 of 12