EVALUATION REPORT OF
(i
METAL SALES MANUFACTURING.CORPORATION
`26 GA.5V-CRIMP PANEL.'
FLORIDA BUILDING CODE 5TH EDITION(2014)
FLORIDA PRODUCT APPROVAL
FL 14645.2=R2
ROOFING
METAL ROOFING
F
r"
Prepared For:
Metal Sales Manufacturing Corporation
}
545.South 30 Street,Suite 200
Louisville,KY 40202
Telephone: (502)8554300
Fax: (502)855-4290
Prepared By:
Bala Sockalingam,Ph.D.,P.E.
Florida Professional Engineer#62240
1216 N Lansing Ave.,Suite C
Tulsa,OK 74106
Telephone: (918)492-5992
FAX: (918)-493-3568
__.
' This report consists of
Evaluation Report(3 Pages including cover)
Installation Details (I.Page) s��t�e�r��►�r�c
OCKAL40
�
NO 62240 � y
ti _1 i r
Report No. C2010-2
Date:3.27.15 STATE OF
3•'30. 20 t�5_
6
;E
s��3
__...,...--
._.__... ........
-- —.-....._._..._._........_.._.__.._..._..._._........—...........__....----------_ . _ _..... __... ........_
..... _ ...._.__._..._.. ._... .._._._._._..---------—--......._...._.._....--. _.._...,_..
. ._ ..
-......._.._.------ —
FL 14645.2-R2
C2010-2
3.27.15
Page 2 of 3
Manufacturer: Metal Sales Manufacturing Corporation
Product Name: 5V-Crimp
Panel Description: 24"wide coverage with(5) 1/2" high ribs
Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A792) or painted steel (ASTM A755).
Deck Description: Min. 19/32" thick plywood for new and existing constructions.
Designed and installed as per FBC 2014.
Deck Attachment: 8d x 2.5" long ring shank nails or#8 x 2" long wood screws @ 6" o.c.
(Minimum) in the plywood field and edges
Underlayment: Minimum underlayment as per FBC 2014 Section 1507.4.5.1
Slope: 1/2:12 or greater in accordance with FBC 2014 Section 1507.4.2
Design Uplift Pressure: 84.5 psf @ fastener spacing of 24" o.c.
(Factor of Safety=2) 131.3 psf @ fastener spacing of 18" o.c.
149.6 psf @ fastener spacing of 12" o.c.
Fastener Pattern:
Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener
shall be of sufficient length to penetrate through the deck a minimum
of 3/8".
At panel ends 6 fasteners per panel width. (4 located adjacent to ribs and 2 between
ribs)
At intermediate 4 fasteners per panel width. (4 located adjacent to ribs)
Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard
Requirements for Metal Roofing Systems'.
Code Compliance: The product described herein has demonstrated compliance with FBC
2014 Section 1507.4
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum support spacing listed herein shall not be
exceeded. This evaluation report is not applicable in High Velocity
Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2014 Section 1505 and current
approved roofing materials directory or ASTM E108/UL790 report
from an accredited laboratory for fire ratings of this product.
es o.s.
PIAT: WlE•
PANEL FASTENER 1-1 Nmm
5V-CRIMP SEE DETAIL 1 SPACING PER ALLOWABLE
PRESSURE TABLE.
YYY ro
11
II I II
UNDER YLA MENT SHALL BE INSTALLED MINIMUM ATTACHMENT: 19/32"DTHICK (MIN.) o
AS PER MANUFACTURER'S INSTALLATION 8d x 2.5" LONG RING SANK NAIL
GUIDELINES OR #8 x 2" LONG WOOD SCREWS
MIN. 2X_WOOD RAFTER/JOIST/
TRUSS AT MAX. 24" O.C. SPACED ® 6" O.C. IN THE FIELD &
AT PLYWOOD EDGES
FASTENER PATTERN AT INTERMEDIATE LOCATIONS =
5V-CRIMP SEE DETAIL 1 24"
00
\ U N
U' w N
® Z r_-0
I^�o
x
}}
II � (nY I
N
UNDER MENT SHALL BE INSTALLED MINIMUM ATTACHMENT: 19/32"DTHICK (MIN.) WE_i00
I
AS PER MANUFACTURER'S INSTALLATION $d x 2.5" LONG RING SANK NAIL j c-4
GUIDELINES v� =Ino
MIN. 2X_ WOOD RAFTER/JOIST/ OR #8 x 2" LONG WOOD SCREWS I� 5u)
TRUSS AT MAX. 24" O.C. SPACED ® 6" O.C. IN THE FIELD & N goo
AT PLYWOOD EDGES
FASTENER PATTERN AT PANEL ENDS
TYPICAL PANEL INSTALLATION X-SECTION ALLOWABLE UPLIFT PRESSURE
FASTENER PRESSURE w
SPIN)G (PSF) w a
#9-16 OR #10-14 WOODSCREWS a a V
_ � m
WITH SELF SEALING WASHER AT 24 84.5 a
MAXIMUM SPACING OF 24" O.C. Q�
18 131.3 3 Z i�oa
SV-CRIMP 5�«
MIN 26 GA. 12 149.6
rn
GENERAL NOTES N
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE (FBC).
2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.017"). EFFECTIVE COVERING
WIDTH OF PANEL = 24'.
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
SPECIFIED ON THIS DRAWING.
UNDERLAYMENT PLYWOOD 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS
19/32"THICK (MIN.) PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS
ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING.
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & HE FLORIDA
BUILDING CODE. IF A BETTHE MINIMUM
DETAIL 1 REQUIREMENTS OF THISDIFFERENCE DRAW NG &THE CODE, THENCODE SHALL CONTROL.
6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS wiN N REV.
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. 2010—Z
SNEEf N0.
OF 1
COOK & MENARD ARCHITECTURE INC.
806 Delaware Avenue, Fort Pierce, Florida 34950
PHONE(772)460-7751 FAX(772)460-4244
EMAIL cookmenard@yahoo.com
November 10,2016
St. Lucie County Building Department
Attn:Roof Permit Plan Review
2300 Virginia Avenue
Ft. Pierce, FL 34982
Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure located at
355 Palms Avenue,St Lucie County, Florida
Manufacturer: Metal Sales Manufacturing Corporation
Profiles: 26 GA.5V-Crimp Panel, FL#14645.3
Code: FBC 2014;Section 1507
Wind Speed: 165 MPH; Ultimate Design Wind Speeds
Exposure: B
Mean Roof Height: 15' Maximum
Pitch: 6/12"
Required Design Pressure: Zonel:-40.6 Zone 2:-57.4 Zone3:-107.9
Maximum Uplift Pressure: 41.6 psf@ fastener spacing of 36"o.c.
74.8 psf @ fastener spacing of 16"o.c.
196.75 psf @ fastener spacing of 8"o.c.
Fastener Pattern:
Type: #9-16 or#10-14 hex head wood screws with sealed washer. Fastener shall be of
sufficient length to penetrate through the deck a minimum of 3/8".
At panel ends @ 6"o.c.across panel width
At intermediate @ 12"o.c.across panel width
Underlayment 30#Felt
Roof Decking: 8d x 2.5" long ring shank nails or#8 x 2"long wood screws @ 6"o.c. in the plywood
field and @ 4"o.c.at edges
The above approved,as per Florida Building Code Compliance acceptances, 2014 Florida Building Code,and the
Manufacturer's recommendations.
Respectfully Submitted,
Peter B.Cook
Cook& Menard Architecture, Inc.
Florida Registration No. AA0003494, NCARB Certification No. 31789
FL 14645.3-R2
C2010-3
3.27.15
Page 2 of 3
Manufacturer: Metal Sales Manufacturing Corporation
Product Name: 5V-Crimp -
Panel Description: 24" wide coverage with(5) 1/2" high ribs
Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A792)or painted steel (ASTM A755).
Deck Description: Min. 19/32" thick plywood for new and existing constructions.
Designed and installed as per FBC 2014.
Deck Attachment: 8d x 2.5" long ring shank nails or#8 x 2" long wood screws @ 6" o.c.
(Minimum) in the plywood field and @ 4" o.c. at edges
New Underlayment: Minimum underlayment as per FBC 2014 Section 1507.4.5.1.
Required for new construction and optional for reroofing construction.
Existing Underlayment: One layer of asphalt shingles over one layer of#30 felt. For reroofing
(Optional) construction only.
Slope: 1/2:12 or greater in accordance with FBC 2014 Section 1507.4.2
Design.Uplift Pressure: 41.6 psf @ fastener spacing of 36" o.c.
(Factor of Safety=2) 74.8 psf @ fastener spacing of 16" o.c.
196.75 psf @ fastener spacing of 8"o.c.
Fastener Pattern:
Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener
shall be of sufficient length to penetrate through the deck a minimum
of 3/8".
At panel ends @ 6" o.c. across panel width
At intermediate @ 12" o.c. across panel width
Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard
Requirements for Metal Roofing Systems'.
Code Compliance: The product described herein has demonstrated compliance with FBC
2014 Section 1507.4
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum support spacing listed herein shall not be
exceeded. This evaluation report is not applicable in High Velocity
Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2014 Section 1505 and current
FL 14645.3-R2
C2010-3
3.27.15
Page 3 of 3
approved roofing materials directory or ASTM E108/UL790 report
from an accredited laboratory for fire ratings of this product.
Supporting Documents: TAS 125 Test Reports
Farabaugh Engineering and Testing Inc
Project No. T181-05,Reporting Date 7/21/05 (Tests#1 &2)
Project No. T240-09, Reporting Date 9/22/09
Architectural Testing, Inc.—West Palm Beach, FL
(Formerly Hurricane Test Laboratory,LLC)
Project No. 0103-0712-09, Reporting Date 9/1/09