HomeMy WebLinkAboutDrawing 53" X 80"
1
REPLACE DOOR&SIDELIGHT IN 1 OPENING ONLY.
NEW DOOR&SIDELIGHT TO BE IMPACT RESISTANT-
SHUTTERS NOT REQUIRED.
OPENING PRODUCT DESIGN
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO. WIDTH. HGT. I FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG.
1 53 80 29.44 1 4 46.8 1 -51.0 FL8228.7 52.0 1 -52.0 FRONT ENTRY-LSMI
REPLACE EXISTING DOOR&SIDELIGHT AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOOR&SIDELIGHT.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR&SIDELIGHT FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 3/16"TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT= 22 FT 9 IN
HEYNE RESIDENCE
115 PEPPER LANE DOOR REPLACEMENT PLAN
JENSEN BEACH, FLORIDA