Loading...
HomeMy WebLinkAboutDrawing 53" X 80" 1 REPLACE DOOR&SIDELIGHT IN 1 OPENING ONLY. NEW DOOR&SIDELIGHT TO BE IMPACT RESISTANT- SHUTTERS NOT REQUIRED. OPENING PRODUCT DESIGN OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS NO. WIDTH. HGT. I FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG. 1 53 80 29.44 1 4 46.8 1 -51.0 FL8228.7 52.0 1 -52.0 FRONT ENTRY-LSMI REPLACE EXISTING DOOR&SIDELIGHT AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOOR&SIDELIGHT. NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. ALL DOOR&SIDELIGHT FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 3/16"TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES MEAN ROOF HEIGHT= 22 FT 9 IN HEYNE RESIDENCE 115 PEPPER LANE DOOR REPLACEMENT PLAN JENSEN BEACH, FLORIDA