Loading...
HomeMy WebLinkAboutProduct Approval RECEI`V:D NOV 13 7011b MIAMI-DADS COUNTY MIAMhI WE ��, S.�,s�� PRODUCT CONTROL SECTION ""4' T. 11805 SW 26 Street.Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE.ADMINISTRATION DIVISION T(786)315-25901:(786)315-2599 NOTICE OF ACCEPTANCE (NOA) tivwivaniauiidstdeso�lerouonty GAF 1 Campus Drive C y Parsippany,NJ 07054 FILE SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid.after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the Nigh.Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Timberline HD'`",Timberline Natural Shadow"',and Timberline American Harvest Shingles LABELING: Each unit shall bear a permanent label Willi the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after it renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and.removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 13-0419.04 and consists of pages 1 through 6. The submitted documentation was reviewed by Juan E. Coilao, R.A. NOA No.: 14-.1022.20 MIAMI-DADECOUN7Y ! ; Expiration Date:02/21/17 1 Approval Date: 02/05/15 t` ,r Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Asphalt Shingles Materials: Laminate Deck Tvne• Wood SCOPE This approves GAF Timberline HDp',Timberline Natural Shadow' ,and Timberline American Harvest`' Shingles as manufactured by GAF as described in Section 2 of this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications GAF Timberline HVR 13 /:�'x 39'/8" TAS 110 Fiberglass reinforced heavy weight asphalt Mangpcluring roof shingle,with a laminate profile Locations#1,2,3,4;S,6,7 GAF Timberline Natural 13 �/, x 39 31s TAS 110 Fiberglass reinforced heavy weight asphalt Shadow`"` roof shingle,with a laminate profile Manufcrcturirtg Locations#1,2,3,4,5,6,7 GAF Timberline American 13 '/4"x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt Harvese roof shingle,with a laminate profile MangMcluring Locations#2,4,5,6 MANUFACTURING LOCATION 1. Tampa,FL 2. Michigan City, IN 3. Baltimore,MD 4. Myerstown, PA 5. Ennis,TX 6. Tuscaloosa, AL 7. Dallas,TX NOA No.: 141022.20 � ;COUNTY Expiration Date:02/21117 Approval Date:02/05/15 Page 2 of 6 EVIDENCE SUBMITTED Test Auency. Test Identifier Test Name/Report Date Underwriters Laboratories,Inc. ASTM D3462 I l CA48924 10/24/11 Underwriters Laboratories,Inc ASTM D3462 1 OCA21994 04/22/11 Underwriters Laboratories,Inc ASTM D3462 I OCA28717 07/26/11 Underwriters Laboratories,Inc. ASTM D3462 OSCA47541 11/10/06 Underwriters Laboratories, Inc. ASTM D3462 06CA31580 11/30/06 PRI Asphalt Technologies, Inc. ASTM D3462 GAF=101-02-02 11/02/05 Underwriters Laboratories, Inc. ASTM D3462 06NKOS 159 08/09/06 PRI Asphalt Technologies,Inc. ASTM D3462 GAF-098-02-02 11/08/05 Underwriters Laboratories, Inc. ASTM D3462 02NK41809 08111/02 Underwriters Laboratories,Inc. ASTM D3462 03N.K26444 10/17/03 Center for Applied.Engineering ASTM D3462 257989 05/13/97 Underwriters Laboratories,Inc. TAS 107 01NK45803 04/13/94 Underwriters Laboratories, Inc. TAS 107 06NK05159 08/09/06 Underwriters Laboratories,Inc. TAS 107 04NKO4273 02/20/04 Underwriters Laboratories, Inc. TAS 107 OSCA42840 1 Ill I/O5 Underwriters Laboratories, Inc. TAS.107 02NK4181 1 11/11/02 Underwriters Laboratories,Inc. TAS 107 03CA35209 10/17/03 Underwriters Laboratories,Inc. TAS 107 04CA13.850 08/30/04 Center for Applied.Engineering TAS 100 257989 04/01/97 PRI Asphalt Technologies, Inc. TAS 100 GAF-044-02-01 01/13/04 PRI Asphalt Technologies, Inc. TAS 100 GAF-098-02-01 11/08/05 PRI Asphalt Technologies,Inc. TAS 100 GAF-101-02-01 11/09/05 PRI Asphalt Technologies, Inc. TAS 100 GAF-1 16-02-02 03/23/06- PRI 3/23/06PRI Asphalt Technologies, Inc. TAS-100 ELK-083-02-01 10/16/02 ELK-084-02-01 10/15/02 ELK-085-02-01 10/14/02 ELK-086-02-01 10124/02 ELK-087-02-01 10/21/02 .ELK-088-02-01 1.0/1-6/02 ELK-107-02-01 10/09/03 ]ELK-108-02-01 10/09/03 ELK-1 09-02-01 10/09/03 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved. Roofing Materials.Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida. Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA.No.: 14-1022.20 rtu►MNnADe COUNTY Expiration Date:02/21/17 I APPROVED Approval Date:02/05/15 Page 3 of 6 INSTALLATION 1. Shingles shall.be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS J 15 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail'A',attached. 5. Nailing shall be in compliance with Detail'B', attached. LABELING Shingles shall bear the imprint or identifiable marking of the manufacturer's name orlogo, city and state of manufacturing facility, and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAWDADE COUNTY BUILDING PERMIT REQUIREMENTS 1. Application for building.permit shall be accompanied by copies of the following: 11 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. MIAMFDADE COUNTY NOA No.: 14-1022.20 Expiration Date:02/21/1.7 Approval pate:02/05/15 Page 4 of 6 DETAIL A COURSE LAYOUT DECK FULL 5th 17" OFF 4th 11"OFF 3rd 6"OFF 2nd FULL 1st MIAM6DADE COUNTY NOA No.: 141022.20 Expiration Date: 02/21/17 Approval Date:02/05/15 Page 5 of G DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN #-�----- 39-3/811 {t m) 14-1/Z'-17-1/2" 14-117'-17-1/2" lob (366-445mm) (368-445mm) ail guide line //��� 6-1/2"-9-1/2" 6-1/2"-9-1/2" 3-1IT ass-2et�m (ISS-241-1 53/4"-6-114" (337mm} (146mm-1,69mm) rrr-2-r2• from bottom of shingle elf seal adhesive on back ENHANCED NAILING PATTERN - six nails pershingle* required by some local codes and required for enhanced vdrvd coverage on certain products. See tirnited warranty(or details. These shingles MUST be nailed a nominal 6"(152mm)from bottom of of shingle, above the cut outs,as shown. Nails must not be.exposed.. END OF THIS ACCEPTANCE NOA No.: 14-1022.20 MunMnaaECOU Expiration Date:02/2.1/17 Approval Date:02/05/15 Page 6 of 6