HomeMy WebLinkAboutProduct Approval 11128f2Q16 Florida Building Code Online
ue... ,. ,., k
SCtS tiarne Lay fn lir fetystratian i Hat ibpits t Submit Surderp 4 Stats 8 Fads } Pubfiiradam FK Staff 4 BM Site Map y links , Seardr
Fk ncb
rO.,
Product Approval
S; USUL-Pubic User
S��GraX:3�i'��R�Yi
Product Appmval Menu>Pr°dad or Application Search>Apr4ication List>Appl(tation Detail
FL.# FL5444-119
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer CertainTeed Corporation-Roofing
Address/Phone/Email 18 Moores Road
Malvern,PA 19355
(610) 651-5847
mark.d.harner@saint-gobain.com
Authorized Signature Mark Harrier
mark.d.harner@saint-gobain.com
Technical Representative Mark D.Harner
Address/Phone/Email 18 Moores Road
Malvern,PA 19355
(610) 651-5847
Mark.D.Harner@saint-gobain.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
nonda Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/03/2017
Validated By John W.Knezevich,PE
's Validation Checklist-Hardcopy Received
Certificate of Independence FL5444 R9 COI 2016 01 COI Nieminen.Ddf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161,Class F 2009
ASTM D3462 2009
ASTM D7158,Class H 2008
Equivalence of Product Standards
Certified By
Sections from the Code
hripsJ/www.flaridablrilding org/pr/pr_appO.aspx?param=wGEVXQwtDratah1g07CSsoycOr128CcpCIS%2f�cD10m5s°lp3d 1/2
11/2812016 Fludda WIding Code Online
Product Approval Method Method 1 Option D
Date Submitted 07 1612016
Date Validated 02/16/2016
Date Pending IBC Approval 02117/2016
Date Approved 04/12/2016
SummarV of Products
Ft # Model,Number or Name Description
5444.1 CertainTeed Asphalt Roofing 3-tab,4-tab,strip(no-cut-outs),laminated and architectural
Shingles asphalt roof shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL5444 R9 H 2016 02 FINAL ER CERTAINTEED Asphalt
Approved for use outside HVHZ:Yes Shingle FL5444-R9.pdf
Impact:Resistant:N/A Verified By:Robert Nieminen,PE PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other.Refer to ER Section 5 for Limits of Use Evaluation Reports
FL5444 R9 AE 2016 02 FINAL ER CERTAINTEED Asphalt
Shingle FL5444-R9.pdf
Created by Independent Third Party:Yes
SacR Prext
Contact Us::2601 Blair Stone Road.Tallahassee FL 32349 Phone:850-987-1824
The State of Florida is an WEED employer.Copyright 2(07-2013 State of Florida.::Privacy Statement::Atcessibirrty Statement:.,Refund statement
Under Florida law,email addresses are public records If you do not wart your e-mail address released in response to a pub0o-nennds request,do not send electronic
mal to this entity.Instead,contact the office by phone or try traditional mail.If you have any questions,please contact 850.487.1395.int to Section
456.275j1),Florida Stables,effective October 1,2012,lirsnseestoansed under-Chapter 455,F.S.must provide the Department with an email addles;it 40"have
one.The emals provided may be used for official communication ation with the licensee-However email are public record.If you do not wish to sup*a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under chapter
4SS.F.S.,plazse dick hie.
Product Approval Accepts.
Credlt Card
Safe
httpsJ/www.flcridabuilding.org/pr/pr app dffimpx?param=wGEVXQwtDgtahlgO7CSsoycOr128CcpCISg/gA3bcD1Om5s°/g3d 212
W280116 Floridly Building Code Offline
(XP
RMI:Hone 4 Lzq fit i User fm d Hat Ttlpifs f SW=ft SY¢d¢rg StM 8 Fans t � 3 Mc Staff j am Sfi'Flap { Lucks j Search
a 3 .
Y` Ig Iu Product Approval
tUSER:Public User
Product Approval Menu>Product or Aonlication Search>Application List
- � Search Criteria Refine Search
Code Version 2014 FL# ALL
Application Type ALL Product Manufacturer CertainTeed Corporation-Roofing
Category Roofing Subcategory Asphalt Shingles
Application Status ALL Compliance Method ALL
Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL
Product Model,Number or Name ALL Product Description ALL
Approved for use in HVHZ ALL Approved for use outside HVHZ AU-
Impact
LLImpact Resistant ALL Design Pressure ALL
Other ALL
Search Results-Appfkcaflons
IMg Manufacturer validated 8 status
FL5444-R9 Revision CertainTeed Corporation-Roofing John W.Knezevich, PE Approved
History Category:Roofing (954)772-6224
Subcategory:Asphalt Shingles
"Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
Conrad Its::Mill Blair SbNw Read,Tallahassee FL 32399 Phone:893487-1824
The State of Florida Is an AARM employer..Cawright 201I7-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Wilder Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send elec rook
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have arty questiom,please corrtact 85o.487.M9,*Pposmnt to Sedion
455.275(1),Florida Stites,effective October 1,2012,licensees licensed under Chapter 455,FS.must provide the Department with an mail address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter
455,F,S.,please dick here.
Product iApp—al Accept-
Credit Car"tl
Safe .
h1M:is9/wwwJlon labtelding orW1pr app Ist aspx 111
MIAMF lDE ii11AMI RADE COUNTY
ePRODUCT CONTROL SECTION
11805 SW 26 Sh=t Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99
NOTICE OF ACCEPTANCE (NOA) www.miamidade eavimenumy
Interwrap,Inc.
32923 Mission Way
Mission,BC,Canada V2V-6E4
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials_The
documentation submitted has been reviewed and accepted by Miami Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control
Section (fn Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Titanium®UDL-25 PLUS,Titanium®UDL-30,Titauium®UDL-50,UDL TT,UDL TF,
UDL TTMC-300,RhinoRoof U10,RhinoRoof U15,RhinoRoof U20,Titanium UDL25,and
RhinoRoof RSA Synthetic Underlayments
1 ABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement:"Miami Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 13-0610.01 and consists of pages 1 through 5.
The submitted documentation was reviewed by Alex Tigera.
NOA No.:14-0603.18
r+wMMADEcoUNrr Expiration Date: 08/08/18
Approval Date: 06/11/15
Page 1 of 5
ROOFING COMPONENT APPROVAL
Ca a : Roofing
Sub-Catmory: Underlayment
Material: Polypropylene
SCOPE:
This acceptance is for Titanium'UDI-25 PLUS,Titanium®UDL-30,Titanium®UD1-50,UDL TT,UDL TIS',
UDL TTIVIC 300,RhinoRoof U10,RhinoRoof U15,RhinoRoof U20,Titanium UDL25,and RhinoRoof RSA
Synthetic Underlayments as described in this Notice of Acceptance,for use with approved prepared roof assemblies
where ASTM D226 Type underlayment is specified and installed with prescribed approved fasteners and fastener
densities.Designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the
Florida Building Code
PRODUCT DESCRIPTION:
Test Product
Product Dimensions Specification Description
Titauin4I UDL-25 PLUS 48"x 250'rolls ASTM D226 Woven synthetic polymer underlayment with one
Manufacturing Type I&lI side coated with UV protected and slip resistant
Location#1 polymer stabilized polypropylene on both sides.
Titanium'UDL-30 48"x 250'rolls ASTM D226 Woven synthetic polymer underlayment with two
Manufacturing Type I&H sides coated with UV protected and slip resistant
Location#1 polymer stabilized polypropylene on both sides.
Titanium®UDL-50 48"x 250'rolls ASTM D226 Woven synthetic polymer underlayment with two
Manufacturing Type I&H sides coated with UV protected and slip resistant
Location#1 polymer stabilized polypropylene on both sides.
UDL TT 48"x 250'rolls ASTM D226 Woven synthetic polymer underlayment with one
Manufacturing Type I&lI side coated with UV protected and slip resistant
Location#1 polymer stabilized polypropylene on both sides.
UDL TF 48"x 250'rolls ASTM D226 Woven synthetic polymer underlayment with two
Manufacturing Type I&H sides coated with UV protected and slip resistant
Location#1 polymer stabilized polypropylene on both sides.
UDL TTMC-300 48"x 250'rolls ASTM D226 Woven synthetic polymer underlayment with two
,Manufacturing Type I&H sides coated with UV protected and slip resistant
I Location#2 polymer stabilized polypropylene on both sides.
RhinoRoof U10 42"x 286'rolls ASTM D226 Woven synthetic polymer underlayment with two
Manufacturing Type I&11 sides coated with UV protected and slip resistant
Location #3 polymer stabilized polypropylene on both sides.
MQAMH]AQE CNOA No.:14-0603.18
OUNTY
. , Expiration Date: 08/08/18
Approval Date: 06/11/15
Page 2 of 5
RhinoRoof U15 42"x 286'rolls ASTM D226 Woven synthetic polymer underlayment with two
iaanufactin,hig Type I and U sides coated with UV protected and slip resistant
Location #3 polymer stabilized polypropylene on both sides.
RhinoRoof U20 42"x 286'rolls ASTM D226 Woven synthetic polymer underlayment with two
Manufacturing Location#3 Type I and U sides coated with UV protected and slip resistant
polymer stabilized polypropylene on both sides.
Titanium UDL25 48"x 250'rolls ASTM D226 Woven synthetic polymer underlayment with two
Manufacturing Location#3 Type I and H sides coated with UV protected and slip resistant
polymer stabilized polypropylene on both sides.
RhinoRoof RSA 36"x 67'rolls ASTM D1970 Unreinforced polymer modified bitumen material
Manufacturing Location#4 adhered to the underside of a polymer-coated,
synthetic woven sheet. The underside is backed
with a release film
MANUFAC7URING LOCATIONS:
1. MLI
2. ML2
3. M13
4. ML4
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Intertek Testing Services #3031783 TAS 104 02/19/03
3119607COQ-003B ICC-ES AC48 02/20/08
3124826-01. ASTM E108 02/19/08
3124826MED-007 ASTM El 08 02/25/08
311801 OCOQ-003 ASTM D226 02/20/08
3130639COQ-002A ASTM D226 02/20/08
3146738COQ-003A ASTM D226 06/20/11
3146738COQ-003B ASTM D 1876/TAS 117 03/28/08
101465036COQ-001 ASTM D1970 06/27/14
100539395COQ-006 ASTM D226 06/02/14
101863861 COQ-001A ASTM D226 10/28/14
101823107COQ-011 ASTM D226 12/09/14
Trinity I ERD I15010.05.10 ASTM D4798/D226 05/14/10
138010.08.11 ASTM D226 08/11/11
I35520.08.11 ASTM D2523/D1781 08/17/11
NOA No.: 14-0603.18
ranaaE couly Expiration Date: 08/08/18
Approval Date: 06/11/15
Page 3 of 5
i
INSTALLATION SPECIFICATIONS:
Titanium' UDL-25 PLUS, Titanium@ UDL-30, Titanim® UDL-50, UDL TTMC-300, UDL TT, UDL TF,
RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic
Underlayments
1. Titanium@'UDL-25 PLUS,Titanium'UDL-30,Titanium'-UDL-50,UDL TTMC-300,UDL TT,UDL TF,
RhinoRoof U10,RhinoRoof U15,RhinoRoof U20,Titanium UDL25,and RhinoRoof RSA Synthetic
Underlayments shall be installed in strict compliance with applicable Building Code.
2. Titanium@ UDL-25 PLUS,Titanium UDL-30,Titanium UDL-50,UDL TTMC-300,UDL TT,UDL TF,
RhinoRoof U10,RhinoRoof U15,RhinoRoof U20,Titanium UDL25,and RhinoRoof RSA Synthetic
Underlayments shall be installed with a minimum 4-inch head lap in a shingle layer fashion.
3. Titanium`'UDL-25 PLUS,Titanium®UDL-30,Titanium'UDL-50,UDL TTMC-300,UDL TT,UDL TF,
RhinoRoof Ul 0,RhinoRoof U15,RhinoRoof U20,and Titanium UDL25 Synthetic Underlayments shall be
fastened with Miami Dade approved corrosion resistant tin-caps and 12 gauge 1 '/4"annular ring shank nails,
spaced 6"o.c. at all laps and three staggered rows fastened 12"o.c.in the field of the roll.
4. Titanium'UDL-25 PLUS,Titanium'UDL-30,Titanium@ UDL-50,UDL TTMC-300,UDL TT,UDL TF,
RhinoRoof U l0,RhinoRoof U 15,RhinoRoof U20,Titanium UDL25,and RhinoRoof RSA Synthetic
Underlayments may be used with Asphaltic shingles,Wood shakes and shingles,Non-structural metal roofing,
and quarry slate.Titanium`°UDL-30,Titanium@ UDL-50,UDLTTMC-300,UDL TT,UDL TF,RhinoRoof
U 10,RhinoRoof U 15,RhinoRoof U20,Titanium UDL25 and RhinoRoof RSA Synthetic Underlayments shall
not be used as roof tile underlayments.
S. For Roof Tile applications;Titanium@ UDL-25 PLUS may be used as an anchor sheet in roof file applications
when used in combination with a top membrane layer,consisting of a Miami-Dadc approved TAS 103 self-
adlicring undcrlaymcnt.(Scc current NOA listing of approved TAS 103 self-adhering undcrlaymcnt for
installation guidelines and limitations of use).
6. For fire classification of specific roof assemblies using Titanium'F" UDL-25 PLUS, Titanium`s UDL-30,
Titanium@ UDL-50,UDL TTMC-300,UDL TT,UDL TF,RhinoRoof U10,RhinoRoof U15,RhinoRoof U20,
i Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments refer to a current Approved Roofing
Materials Directory for fire ratings of this product.
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly
evaluate the installation of this material.
NOA No.:14-0603.18
�ntuwt zulz COUNTYNOA
Date: 08/08/18
Approval Date: 06/11/15
Page 4 of 5
y �
IAMITATIONS:
1. Fire classification is not part of this acceptance,refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
3. Titanium UDL-25 PLUS, Titanium' UDL-30, Titanium® UDL-50, UDL TTMC-300, UDL TT, UDL TF,
RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic
Underlayments shall be applied to a smooth,clean and dry surface with deck free of irregularities.All nails in
the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep the deck
thoroughly to remove any dust and debris prior to application.
4. Titanium`s UDL-25 PLUS, Titanium? UDL-30, Titanium® UDL-50, UDL TTMC-300, UDL TT, UDL TF,
RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic
Underlayments shall not be hot mopped,refer to manufacturer's published literature for product compatibility.
5. Titanium' UDL-25 PLUS, Titanium's UDL-30, Titanium® UDL-50, UDL TTMC-300, UDL TT, UDL TF,
RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic
Underlayments shall not be applied over an existing roof membrane as a recover system.
6. Titanium UDL-25 PLUS, Titanium UDL-30, Titanium UDL-50, UDL TTMC-300, UDL TT, UDL TF,
RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic
Underlayments shall not be left exposed as a temporary roof for longer than 30 days of application.
7. UDL TMC-300 Synthetic Underlayment shall not be left exposed as a temporary roof for longer than 180
days of application.
8. Titanium's UDL-25 PLUS, Titanium' UDL-30, Titanium® UDL-50, UDL TTMC-300, UDL TT, UDL TF,
RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic
Underlayments are components used in roof system assemblies.Roof system assemblies are approved under a
specific Notice of Acceptance. Refer to Prepared Roofing system Product Control Notice of Acceptance for
listed approval of this product with specific prepared roofing products.
9. Titanium' UDL-25 PLUS, Titanium' UDL-30, Titanium' UDL-50, UDL TTMC-300, UDL TT, UDL TF,
RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic
Underlayments may be used with any approved roof covering Notice of Acceptance listing Titanium'UDL-25
PLUS, Titanium"s UDL-30, Titaniume UDL-50, UDL TTMC-300, UDL TT, UDL TF, RhinoRoof U10,
RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments as a
component part of an assembly in the Notice of Acceptance. If Titanium's UDL-25 PLUS,Titanium UDL-
30, Titanium'UDL-50, UDL TTMC-300, UDL TT,UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof
U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments are not listed, a request may be made
to the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Department for
approval provided that appropriate documentation is provided to detail compatibility of the products;wind
uplift resistance,and fire testing results.
10. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo
and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County
Product Control Seal as shown below.
CNLAMHW=2ADEC0=UNMW
11. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.:14-0603.18
MIAMFDADfi COUNTY Expiration Date: 08/08/18
Approval Date: 06/11/15
Page 5 of 5
EXTERIOR RESEARCH&DESIGN,LLC
tertiftcate Of AuthoiizzoGon#9503
TR.1N1TY:`ERD' 353 CHRISTIAN STREET,UNIT#13QXFORD,CT 06478
P.HONEt(203)2627,9245:
FAX:(203)262-9243.
EVALUATION REPORT
CertainTeed Corporation. Evaluation Report 3532.09.05=1110-
18'Moores Road. _ FM44-R9
Malvern,PA 19355 Date of Issuance;09/22/2005
Revision 1002/16/Z616
SCOPE:
This Evaluation.:Report is,.issued under Rule 61620-3 and the applicable'rules. and.regulations governing the use.of
construction materials in:the:State of.Florida.The documentatlon.submitted has been reviewed:.by-Roberk.Nieminen,P.E.for,
use of the product.undee the Florida'Buildmg.Code:and Florida Building Code,.Residential Volume: The products;described ..
herein have.been evaluated for compliance with the 5'Edition(2014)Florida Building Code sections noted herein:
:DEscRIPnom CeitainTeed Asphalt Roofing:Shingles..
LaBEunto. tabehng:shall be in accordance with the requirements of the Accredited:Quality Assurance Agency noted herein
and FBC 1507.2.1.1 ..
CONTINUED COMPLIANCE:. This Evaluation Report is.valid until:such time as the named products) changes; the referenced
C!uality Assurance•.documentation changes,or provisions of the;Code.that relate to.the product change..Acceptance of this
Evaluation Report by:the named client constitutes agreement tO.notify Robert:Nieminen;P.E :if.the,prOduct changes or the
referenced.Quality Assurance documentations changes TnnityIERD requires a-complete:;review of this Evaluation Repprt ;
.relative to.updated Code nr tlWrements with`each Code Cycle::
ADvamsEmEW: The Evaluation Report number preceded-by the words:"TrinitylERD Evaluated" may be displayed. in
advertising literature: If anyportion of the Evaluation Report:is;displayed;then it shall be.done.in.its entirety:
(N5PECTION:'Upon request;a COpyOf.thiS enfire.Evalu.ation:Report,shall be provided.to the'user by the manufacturer or its
distributors.and shall.be available;for inspection at:the job site at the:requeAt 6f;the Building Official:
This Evaluation;Report consists of pages l through 12.
:Prepared by:
Robert)M Nieminen,.P.E: ne��sealappearirewwa4horizadbyEugmnN,emmen,
' - Ps-an 02/16/2076.This does not serve as an elecfmnicaliy s�gd.'..
Florida.Registration.No.:59166;;Florida DCA:ANE1983 t ,, r� , a;:�7 d«Vmentsteed,sealedtnrd�opieshavebeentermedtothe:
.__ .. ..di,Tn,ar s` ProductAPprovalAdm4nistratorand tothenamediLent
CERTIFICATION OF INDEPENDENCE:
1 Trinity.)ERD does-not have,.nor.does it intend to acquire or�n►ill it acquire,a.financial.interest:in any company manufacturing.or
distributing products it evaluates.
2 Trinity I ERD Knot owned,operated or controlledby any company manufacturing or distributing products it,evaluates_.
3 , .Robert Nieminen,.P.E.does not have,norwill.acquire,'a financial interest in any co mpany.manufacturng or distributing products for
which the evaluation reports are beinglssued:
4: Robert Nieminen,P.E.does:not.have,nor will acquire,a financial Interest in:any other entity involved in the approval:process of the
product.:.
5. -This is a building:code evaluation. Neither:Trinity(ERD nor Rob KE.are,,in any way;the Designer of`Record focany:
Project on which this Evaluation.Report,or previous versions thereof,is/was used'for permitting'or design guidance unless retained
specifcallyfor that purpose"_.
1� 1 I1� ERS
ROOFING SYSTEMS EVALUATION
1. .::SCOPE:,
Product Category, Roofing
Sub-Category: Asphalt Shingles
Compliance Statement;': :CertainTeed Asphalt Roofing Shingles,as`produced by CertainTeed Corporab6n have demonstrated
compliance with the follolraihk sections of.the Florida Building Code:and Florida Building Code,Residential Volume through testing
in accordance with the foiiowing:Standard& Compliance issubjectto:the installation Rouwrements and Limitations)Conditions of
Use set forth herein.
Z ` :STANDARDst
Section , . Pra er Standard Year
1507.2.5,11905:2:4 Physical Properties ASW D3462 2009
1507,2.7:1,R9U5:2 6,i WindResistance ASTM-D3161.Class,F: :: 2009
1507.2.7:1,11905.2.6.1 Wind Resistance ASTM p7158 Class N 2008
3.:. REFERENCES
Enti Examination Reference : date:
UL(TST 1740) ASTM 03161:: 941U.9632 05/15/1998
UL(TSi 174(1) ASTM 03161: 99NK26506 11[23/1999
UL(TST,1740) ASiM 03161 03CA12702 05/27/2003:
UL_(TST 1740). :. ASTM:0316103CA12702 06/16/2003
UL(TST1740)
ASTM D3161:
03NK29847 ': 10/03/2003
MUST 1740) ASTM D3161 "CA 32 05/24/2004
UL(TST 1740): ASTM D3161 "04CA32986 12/03/2004
UL(TST 1740)_ . ASTMD3161 05NK07049 : - 04/15/2005
UL(UT V40). 'A5m,63161:. 05NK16778 05/12/2005
UL(TSr 1740): ASI M:03161.` 05CA16778 05/12/2005
UL(T5T 1740) ASiM.03161.. 05NK14836 05/22/2005
UL(TST 1740) : ASTM D3161:: 05NK22800 06122/2005
UL(TST 1740).: ASTM D3462 11684 09/21/2005
(TST 1740) ASTM 07158. 05iVK08037 06)28/20
UL 06
V1,(TST 1740) ASTM:D3161:&D3462 09CA28873 07/23/2009
(JL(TST 1740) ASTM D3462': 10CA41303... 14/07/2014
UL(TST 1740} ASTM D3161' 10CA41303 16/08/2010
UL(TWT 1740) ASTM 07158. 10CA41303: . 10[27/2010
UL(TST.1740) ASPM D3161&0346.2 10CA44960 :. 11/11/2010.
UL LLC(TST%28)_ ASTMD3161„D3462;&D7158:. 13CA32897 11/21/2013
UL LLC(TST 9628) ASTM D3161 D3462- TFWZ:R684 04/22/2014
UL LLC(TST 9628): ASTM 07158' TGAH R684. 04/22j2D14
UL LLC(TST 9628): ASTM.031b1&03462: -: : 4786334434`: 05/16/2014
UL LLC(TST 9638):. ASTM D3161&D3462 4786570826 02%12/2015
UL LLC(TST 9628) A5TM.D3161,.D3462:&.D7158: : 4786570717 12/16/2015
UL LLC(TST 9628). ASTM 03161`&03462` 4787195678: 02/09/2016
UL LLC(QV 9625) Quality Control Service Confirmation Expo aT/o312017
4 PRODUCT DESCRIPTION;
41 CT20"',XT-.25,XT-:30 and:X7' 30111 are fiberglass reinforced,3-tab asphalt roof`shingies:
4.2 Carriage House Shangleg,.;Centennial .Slate'°', Grand Manor' Shan9le , Landmarklm Landmark'" iR,
Landmark'" Pro,.Landmark"" Premium, Landmark1°' TL, Landmark' Solaris and.landmark'"' Solans IR are.
fiberglass reinforced;laminated asphalt roof shingles.
4.3 NorthGate"'is a:fiberglass reinforced,lamlrlated,5BS modified:bitumen roof shingle.
Exterior Research and;Design LLG Evaluation Report3532.09AS-R10
Cerw6gw oT Authonza6on#9509 F15�i44R9
Revision I0r02/16/2011,
Page 2 of12
R
TRINITY
4.4 Presidential Shake'",Presidential Shake's IR Presidential Shake TL7 and Presidential Solaris"°are fiberglass,
reinforced,.architectural asphalt roof:shingles:.
.4.S. Hatteras" Highland Slate m:and Highland.Slate!m IR are.fiberglass reinforced;4-tab asphalt.roof.shingles
4.6 Patdotw is.a:fiberglass reinforced asphalt:roof strip-shingle-(with no cut-outs) providing_ as laminated,
appearance through.an intermittent shadow line with contrasting blend:drops forcolor definition.
.4:7 Presidential;:Accessory, Accessory for Hatteras, Shangle Ridge"'; Shadow Ridge"', Cedar:Crest""; Cedar
Crest'" IR;_NorthGate Ridge and NorthGate Accessory.are fiberglass reinforced accessory shingles for hip
and.ridge installation.
4 8 Any of the abovelisted.shingI smay be produced:in AR(algae resistant)versions:.
S; LVATTAT1ONS;
5.1 This is a.building code evaluation. Neither TrinityjERD nor Robert Nieminen;P.E:.are, in.anyway;the
Designer of.Record-for any project on which this Evaluation Report, orprevious versions thereof, is/was
used for permitting or.design guidance unless retained specifically.for#hat:purpose:
5:2. This.EvaluationReport is notfor.use.in the.,WVHZ
53 Fire.Classification is not part of this Evaluation Report; refer to current Approved Roofing 'Materials,
Directory for fire ratings of this:
5.4 Wind Classification:.
5:4.1. All shingles noted:herein are Classified in accordance with FBC:Tables 1507.2-7,61 and R905.2.6:1 to ASTM
D3161,Class F an
dJor ASTM D7158;.Gass H, indicating theshingles are acceptable for us.in all wind zones .
up to Vm=150 mph (V, 194.mph). Refer:to Section 6 for installation requirements to meet this.wind
rating.
5.4.2 Presidential Accessory,Accessory'for Hatteras,Shingle Ridge;Shadow Ridge;:Cedar Crest;NorthGate Ridge.
and NorthGate Accessory hip&,ridge shingles have been.evaluated.in:accordance with ASTM D3161;.Class
F. :All except.NorthGate::Ridge.and North Accessory require use.of BASF Sonolastic NPI adhesive or
Henkel PL® Polyurethane Roof &. Flashing Sealant, applied-as specified in manufacturer's application
instructions; for use.in wind zones up to:V�=.150 mph(V„it:-194 mph).
5.4.3. Classification by ASTM D7158 applies to exposure category.B or.C:antl a:•building height;of.60;feet.or less.
Calculations by a qualified-design professional.are.-required for conditions outside,these limitations.:
Contact the shingle manufacturer for data specific to eachahingle.
5 4 3;1;. Analysis in accordance with,`AST..M D7158 indicates the measured uplift resistance-:(RT)forthe;CertainTeed
asphalt roofing shingles listed:in:Section.4.1 through 46'(except Presidential Solaris:-) exceeds.the
calculated uplift force (FT):at a,maximum.design-wirid-speed of V,s = 150 mph (V.it'=.194.mph) for
residential buildingslocated;in:Ex osure D conditions with:no:to
p pographical variations(flat terrain)having : :.
a mean roof'height]ess than or equal to 60feet. sl
The shingles are permissible:..under Code for installation in.these:conditions :using the installation
procedures. detailed. in this Evaluation. Report and CertainTeed minimum requirements; subject..to
minimum 'codified. fastening requirements established within any locale jurisdiction,,which: shall take
:precedence: :
5.5' AlLproducis in the:roof assembly shall have:quality assurance audits in accordance with the Florida Building
Code and F.A.C.Rule 61G20=3.
6: -.:INsrALLAMON:
6.1_ Roof deck, slope, underlayment and fasteners shall :comply with FBC 1507.2 / 8905:2 and the shingle
manufacturer's minimum requirements.
Exterior Research and Design,LLC. Evaluation Report 3532.09.05410
rnte o Autliorimtion 69503 FL54"R9
- Revision 10:02/16%2016`
Page 3_of'11
0
ERD
3
6.11 Underlayment shall. be acceptable to Cer'tainTeed`Corporation:and "I hold;current Florida.Statewide
Product Approval,: or be Locally:,Approved per Rule'61G2O 3 .per FBC Sections 1507:2.3, 1507.2.4-or .
R9O5:2.3.
6.21 Installation of asphalt shingles shall%comply,with the manufacturer's current published instructions,:using.
minimum four(4)Waits pes shingle in accordance:,ra A FBC 1507.2.7 or Section 1190-5 2.6 a»d the. mi»imam
requi remenis.herein
6.2.1. Fasteners., shah be in accordance:with :manufadurees:"published requirements, but not less than...FBC
1507:2.6 or.R9O5 2.5: Staples are not permitted.
6.2.2 Where the roof slope"exceeds 21 units vertical in 12 units hor¢ontal,use the"Steep Slope"°directions
6.3 CertanTeed;asphaltshingles ars acceptable for use in reroof(tear-off)or recover applications,subject toahe
limitations set forth;in FBC Section 151O and`certainTeed published i»staliation instructions
6.341: MO71 XT''e°n XT-30.XT-30 IR:-
LOW AND ST 0100 SLOi'E STEEP SLORE :
ENGLISH 12':": 12 12 Usrfonrf,
{305 rrnj-+ {3tl5 tmn} (305 nupj-�{
shin'gte(Rigors 11-4).. rooting cement meeting;a$Tbi D458&
1 ( mm} Sealant t ( Vii} TYttc li is suglea
5
tt2 Pa ——— —— —"——
METRIC jsls,: 3tfs =.if 13tls`
Roofing Cement
(2a tnmj Sealant 1 (25 mi Rppfyl'{25aanl JpoL of aspl alt ro4li�g nen[ -
UndettaCh fab ra(net.
6; •; fdgtirsll�i"ttrafo�rna�fsruuJs£rsjwdsofnspller�aardoasdaistrja
dCAUTIO�L•`Eecessire-use of roating cement can causestiingles
to blister,
ffigrirs 11 3:trs�+fournails;�,ret�ryfdllsbkr�e::
6.3.1.1 Nip&Ridgei Cut Shingles
(25' .: �t_j� �,rRemrne ,�,
{► 12 ( mm}
� i25 yaes mn•\
305mm}
Shdngte Sit�ngte 'S�tngte sho�m
. : 5518 ml Dexo �a1`,l
Ixaure'I""l=?rt(.ltd d�lzs;dl7t drinx:bracE_Yo»t®Le sGsu N
��1A5 m aQ
(rsgksbdh�rertsimsssEmast); ��,{?
Flgu,Rt 112�-Iru(alladesn bfcpps dlorig tUe bdps mal rldyes: ..". . . .
Note::For ASTM W161 Class F, use BASF:.Sonolastic NP`1 adhesive or.Henkel':PL® Polyurethane Roof.&
Flashing Sealant,inaccordance with:manufacturer's:instrtiions_
Exterior Research and;Destgn;LLC. Evaluation Report 3532,09 05 RIO
[er6JartenfAuthonioGugg9503.:' ":' 145494-R9
:
Revision 10'02/16/2016
Page 4 of 11'
W- �iNITYIERD.. .
6.3.2 Carriane House Shani;lee,Centennial Slatdl and Grand Manor Shani=leec
lOW AND: STEEP SLOPE,.. .
STANDARD SLdPE rrespots of asphalt roofing cemear.foi etrr}
l tie scn m nails and th
full Grand�fanorSiutngle.:use Cine uail<and three spots a[asphall
use lire nails[or cher}(ull Shangle,:. roofing cen e�ri?.(ul(farri3ge Hoa
i6f for ce Shanglc aqd Centrnmal
qe:Apply asp6aii.rooGog eelnen(1'(2>mm)f�oin etl��e;of shmglc:°
(Fl uw175):Asphalt roofing cement m�rUag;4S[�f Wi58f,:71peif
V' i is cnestrd.,
miri).
(16nan} 122Unun) .
t}S tion} (25tmm)
F iue 17�•tue irr nails area n11 Grrur!Slirr'orSlrrui+ � �_
g f . I �l �_ sra g�B••
(darraer�e:/l�{utas(�rngle;;orGi+nlenulalSlW. {,S6'rrum)�t �� (227 mm}
125rten) "Odwgcametd
Rgure 1;7-5.-R7eminstaffliig Grn+til:1/anor5bamgtm on steed sloA
wsffea natlsrurd lkmdmfs ofa*ball roiifrng wnienl.
6:3.2.1 Nip&,Ridge:Shangle®Ridge
12. 18Exposure ,' Rernove tape
from the right.side
and fasten
SECOND
Fasten theme
deft side RIGHT
Remove..
3has Tape: : FIRST
LEFT'
� oSg � (ge skl i lesF,trr17,19 hlstnllltidtfcRd
Rgre.17SGangleAte on hips
an.d'ridges.
Note: For.ASTM 33161 .loss F, use:BASF Sonolastfc NP 1 adhesive or Henkel PL® Polyurethane Roof.&;
Flashing Sealantin accord..ence:with manufacturer's instru. tons.,
Exterior Research and Design,llC. .. Evaluation Report 3532.09.05-R10
Catifrcwte ofAud�orirctioii u95o3: FLS"4-M
RevisiorrJOc 02/16/2016
Page 5 of 12'
TFUNITYJERD.
6.3:3 .. Landmark"';.landmark" 1% Landmark o Pro '(formerly landmark'" Ptus). Landmark'" Premium,.
Landmark"'.Ti;landmark'Solaris,Landmark'"Solaris IR,NorthGatec
LOW AND.STANDARD SLOPES:
METRIC I)IJAWSIONS .14..
1
mm).; (345 mm}-►�
'� 1 (25 mm) Release Tape 1 (25 mmj
Na�fable� ,_
Area
LANDh1ARK;TI.
13th 13" 13tPz'
mm)-• -(33Q:mm) }- (343 mm)-►�
105
mm -► �-
y ..
Gigurl3 fraJ.�ejorrr�{nilsfore�e�•frrlls�ii{�le.,
NorthGate
%UD
tiaarca t2" tura. 1r
a3lEA (305 mm).-a (375 mm) -i -(305 mm)
r Ra1ng Lr's
t +-1..(25 mm) 'ppe nai lre . .r(25 mm)-►
Jam
liaArtg areae for layv and stamlard sbssas 4 '+2;12 m 2112):.
N31 tie;a�nu{q�rB Frn�;trss�3ss' tsabtn�.
Use six n tils:'w fonts.w o.asphah rooGngcemen'for everiy'fiill` -
Iaminalm sh in Asphalt ioo!)nv0emshouldpiect
A'TAtD4586;a}pc it;1pply I spo(s of a3pLalt roofing cenrent:itarli
each corner stud a1 aliont t2"1o't3"inYront.each ed ec
METRIC:DIMENSIONS
1 r,25 rran.
t ReleasATape; I:.
NO keal -
05 inm} - (25(n
Roofing Cement
Exterior Research and.De§i n,LLC:
Rl1Evaluation Re . . S
GeWP-mW ofAUMorizption#Z03
F15944R9:
Revision lOc 02/16/2016;
Page 6 of 12'
LANDMARK,TL
343.mmY (330 mm) {343'mm
iTO1
t: l
(25mm 1+— -- (25 mm)
Roiling CementI.
Feg►t 13S,Uslesixrr.09?dp!4fONS of, .
aspG�ttioo,ffngcenre�ton sfaeps(o�ac
NorthGatec
NEEP 12" 14-3/4" 12°
SLOPE_. [- (305 mm ---(365 nirrrr ----(305 mm}-►1
NAILING —.(3755Npi' ImitsAREAt1 oween ,r wmm) 1 (25'mm)es.
7.
Roo
{
,ng ement.
ailing areas.far steep slopes:(greaier than 21 12)
and"StonniNailing,�. .
Nail Ww6en lower 2 na16nes as,shown above,
6.3:3:1 Hip&Ridge;Option 1: Shadow Ridge"'or Noth.Gate Accessory. .
Rpre 1316 Shadmn Rtdi,ac�ory sbfngles lkwb;eu 45jy o»
r[rrtts b nra@e72tvrdivl i4d- ippkua
12' 97Pg°
(305mm)' (250inm)
G 8 -015/16°—►}�-41511fi
(150mm) (iWmm): (125inm) I (125*n
t'
Notch for Pldchfor
Cen(ermg: .`:. ;Centering'
12 13/4'
(305mm) ` f (337mm) R°.
PlotchrforA►ignmentto NotchesiorAlignmeMto 5
the Top Edge of the Prevbus T the Top Edge,of the Prevous
(11l�nm)` (196mm?.
Cap for F.(125mn)Expo§ue Captor5518'(i41mm)Exp�ti
Eng i6b'Dimensi6n
Metric Ditnensan
ShadowAldge'0 Shadow Ridge"''
Exterior Research andbWgn,LLL Evaluation Report 353109.05-RIO
CerbficaM ofAu�oriza�i�n p95D3.' FLS""-R9
Reyislon 10:02/16/2016.
Page 7 of 12 ..
T -INN Y[ERCP
WWI
{2SA Istat).
31S+1G'(125rttn)
f 13:-
--{333 mm)
CertpGssl PJtch 4
165 mm)I 168'mm)�:
to 114 A
Align Centering
S1DL"itCS to 1�p 7 131!4'" ` _ Notcti ..
C C£
(337 mm)
gSteneUSGAt415t< Align these 75V .
I notches tap
of . (184 mm)
1 edge of
PneMioumcourse.
Northdate Ridge:. NordlGate,Accessory
i2.. .
_Laymg NoOefi
I
E ) I(
Agttre 13 20 64-49169nokm$to iasrttersbhtgkS on btpsand
ifilge;mu4d 7o&mte ibe cor t arj 'Ozra
Note For ASTM D3161 Class F of.Shadow RidgeTM;.use:BASF Sonolastic NP 1.adhesive or. Henkel PL®`
Polyurethane Roof.&.Flashing Seala�It in accordance Wlth:manufacturee.s instructions
:.6.3.3.2` Hip&::Ridge;Option 2; Cedar Crest7,Cedar Crest 'IR..
Use two fasteners pet.shingle. For-.the starter shingle,.:place fastener,1-Inch from each side edge and
about 2-inch up from the_Starter.shingle.'S exposed butt..edge., For each ful,I Cedar Crest:shingle, place
fasteners 8-5/8-inch up.from Its-exposed:butt:edge and l-inchfrom each:side',edge.
w.
Ma
_ -
. - - -
Exterior Research and sign;.iit Evaluatlan Report.3532,09 05-R10
Ce/bTwuW of AuthorizdBon NM3;
EL54?19-R9 _
Revision 16:02/16/.2016:
Page 8 of'12
i �
R4NITY�ERD
Note: For:ASTM[)3161-Class F,use.BASF'Sonolastic NP 1 adhesive or Henkel PLS Polyurethane Roof'&.
Flashing Sealant to.hand-seal Cedar Crest shingles.-: Apply:NP 1,or PL adhesive from the..middle.of the.
shingle's raised overlay orr the:top.piece'and extending approximately`4-inch along:the sides of the
headlap along a line%to;l-inch'from each side of the shingle's headlap: Immediately align and apply the
overlying shingle;gently pressing;tab sides into the.adhesive,and install nails. To secure the.other side,
apply a i-inch diametersot of of NO 1 or PLadhesive betwie'en the shingle layers.
d
(omni) w- 102mm
3ti
_(25 ioml
...-' •fhv'Nj'i@tA•sZx:
`6.3.4 Presidential Shake"" Presidential Shak6m IR Presidential Shake T&,PresidentialSolaris'"•
LOW AND STANDARD SLOPS STFER:SLOPF
For lou and standard slopes,use live nails for each.full presidential For steep slopes,use Nne.nalls for each Fall Pre�denilal shingle and
shingle as shown;beloiti meter spots of asphalt roolll cemen
apply l'dhii t utter each sldngle tab
�fter'apPtft:$:nails lm belvreen die'naWtigguide lines;apply.4 tGails i
Naiind: AO'— above tab cutouts ludUg ceitabi tabs of oter4ing"gkeoVer tudls
Guide.luies (1016rnm)
51f4 .
(133 inn)
• A •• • • •
iP2 nan} ( 1�} j
NOTE Appry'natls on painted guideline
Fig=lGd Fark�?ng.Presldendol`rmd Precldettwl TL Stenos
1'diameter aspliallrooting cement
' sLhigleson Fmnandsltmdme�s(opets
RkjT16-7_F-ftivPwidenfiadatdPresldentfaf'TJL`S(n .
sfrhtgtgs on s(-p lnpix
6.3.4:1.. Hip&Ridge;.Qption.l Pres dential'Accessory .
PRESIDENTIAL ACCESSORY.
Presidential accessoryslltigles.can be used for covering hipsand
ridaes:.Apply:sliingles up ao the ridge (expose:no.more than 7'Pram.
_ .
the tiottonl edge of.the„tooth''Fasten:each accessory.with t.m#as:
teners.The,fasteners Must be 1314'long or;longer,so they penetrate'
either 3/47;Into the-deck.6 ompleelpIhrongh the.deck Presidential_
accessorycomes in two ditterent sizes..Accessory produced In .
Blrmingham,Ai:.is•12•x 12 ,Portland,•4R<produces 9�/s'x131/4.
accessory'_..
Note:For.ASTM D3161-Gass FuseBASF Sonolastic NR 1 adhesive or Henkel.PL® Polyurethane-Roof.&
Flashing Sealant in accordance with mani facturel'sinstructions
6.3:4.2 tiny &:Ridge,.Option_ 2: Refer to instructions:herein for Cedar,crest , Cedar Crest'"' 'IR hip.and ridge
-
Exterior Research and:Design,UC Evaluation Report"3532.09.OrR10
Cer6]icate ojAuthorjWean nsm F75444-R9
Revlsion 30:02/16/2016
Page 9 of n.
l"R{ {T . ERD
6:3.5 Hatteras'"':
10W'STMNDARIDAMDSTEEPSLOPE 1 worSm) .rnmm) I.(23om+o) ( min) 1
7' 9.
I'{230 mm) 00mm). .tom►tnro): (230 W;) x(25 rcm)
x(25 mmj (25 tnm)�. (2u1�n4
t w,
—RaallogCemcot
(240 mrnj
F4an 15.#fWv)i{q llallemall Orep AM
Forsicep slolxi;n e Gre nri3;ynd rlgle spins nf.ss�itiill taaGng . '
Fi/nor IS:3:dbYire�utg'I►�lirmx{611rkie ou crin�nifQrcarh tu13 ttutriis'�R�ia�rat sl�o��ti oiro�r,appijl
LrmaradSSnir3imr57opes:.. (25eum}dzmacxr;jwt�nfroo6m Umrm(,bT f D.4S ?�1!�11"
for**I slunk n).loipes,wefne niiik fdr rKb'60. sn Wed)nndrr t:'cli mb,rurnt Press sidn a into phce dr uW
Iktlleru shingle t aMmti a"v. espose cemegL
C t(iTlO�c_ibo much fooling ecmentrw causeshingles to bWer. .
6:3.5:1: Hip&Ridge;-Option l;Accessory for.Hatteras .
1 .
Fasten 6nfti si>!�;
err.
1 2
3
Figura 1514:;18 tGree prece rt iifs sepurnls fo mike
4Aa#er[rs9c�essU %s6�n mss:, �.
Note: For ASTM D3161=Class F;use BASF:Sonolastic NP 1 adhesive or Henkel-PL® Polyurethane Roof&
Flashing Sealant in.accordance with manilbcturer's instructions.'
6:3.5.2 Hip_Si Ridge;Option Z.Cut Hatteras.5hingles
.-9
{230 m
d6O mm) `.
Cap CapCap,. Cap
Stingie Shii►gle' Shingle ShinglF.
e
AI 15 2&cut liaftcfas sLinges fo:itia,FeCozy c�* F+„ttre3;j5-.21.-:Insid4dion'qf cstJu tslo>ig fl!/rs:,wd rfd�s
Note: For ASTM':D3161.=Class F use BASF Sonolastic NP:1:adhesive or Henkel PL® Polyurethane Roof`&
Flashing Sealant,in.accordance with.manufacturer's instructions.
Exterior Research and.Design,Lit. Evaluation Report 3532.04 05=Rl0
G�tiTrcote ojAutllo�im6on►195D3: F1125444R4
Revision 10:02/16/2016:
Page 10 of 32"
ER
6.3:6 Highland Slate"',Miehland State"'!R:
LOW AHR STANDAt;D;SlOP STEEP3LOPe
g . ._ UseFlVEn2MandEIGlffSpota_ofz pitiooangcemenf=for each
full:,Hlgidand SL�te shitigle:.For:ir>iamt Daae,Six nails are required;
Apply 1'diameter spoil of:;tsptiaitrooling cement nndereacb lab .
aet � cometc�
AsphaltroaSngcnt meefutg ASIM D:4>.SG Yppe H is suggested::,
t��d
. 9X mstrxai�ffi 1•t2irsmj '., '
— SMrzt':s(fs1't25arnt
'wlaul as:Ywsn�: -
Ffgurrs:f�•3t�u.+f11'Enallsfirct�r}1ll�E�lrmdS� sbt��le — pooihi9' -
Flgrar if 3d:(lse Fl}Ti nail and eigk 001s ofasplall
roAfnrg avitnt utuler earl'roli,iww..
•GAU'YfiN1._1v+ieessire nseot rnofing.cemenCcah cause shingles
to blister
6 3 6.1. Hip.&Ridge,Option 1'Refer to.instructions:herein for Cedar C 6A-.,Cedar CreAl IR,or Shangle.Ridge'"'
hip,and:ridge shingles. .
6.3.7 . 'r• ..
Patriot .. -
LOW AND:STANDARD SLOPE. STEEP3LOPE_
UseFOUR.nails.6r eveiy hill slIingle ,)cited t<ti.shown belo`t f3se FObR nail and font spots. nsph�lt coo ting cement far t ren_Self
shipgk:ts shown Ixl0. kvil.ilt iuofMg c4 cwt tiieciing 1ti7;;\1 I}9586 .-
7ipe 11 i4 su �iKtexl, 1pp1} I'(25.mml spots of asphidt rrroling
Sralira cm.enhts shown.
t ;
CAt"170N CSCCIM use of rool'mg cement can cause shingtes w blister
itd+F-ri
(r3rur)
1?5smmj L' r
ssra':t 074 ' secs}"
1 RconOp Cement ..
(oma). {3�rsaj
Hip&Ridge Refer to mstructions.hereinlor•Cedar Crest' ,Cedar Cresfm IR,:-
Shadow Ridge'",NorthGate
or Shangie Ridge"'hip and ridge shingles.:: .
7. . .-LABEUNG:
7.1: Each. unit shall bear a permanent:label with the manufacturer's name, logo, city,.state.and logo of.the
Accredited Quality"Assurance Agency:noted herein:
7.2 Asphalt shingle wrappers shall indicate compliance:with one of the required classifications.detailed'in.F9I
Table 1507.2:7.1/_R905.2.6:1.
Exterior Research and Design,.LLC_ Evaluation Report 3532 09 Os R10"
CertifcaW cfAuthadzWon#950.
1:1.5444-119
Revision 10:1)2/15/2016:
Page 11 of 12'
1�R1II1�( ERD
8.. BUILDING PERMIT REQUIREMENTS:
As required.by the,Building OfFicial`.or Authority Having Jurisdiction in order to.properly evaluate the.installatiori of
this product:
9. MANUFACTURING PLANTS: _
Contact the named QA entity for information on:wW plants produce products covered`6y Florida Rule'61G20-3'QA
requirements:
10 QuALffyAssURANCE ENTITY.'
UL LLC.=QUA9625;(414)248-6409;-karen.b6chmann@Us.ul:com
END OF19VALUATION REPORT-
Exterior Research end Design,LLC. Evaluation Report 3532.09.05 R10
GeitijOW of AnOhonza(ion g95o3
FOO-R9
- - Revision lo:A2/16/2016`