Loading...
HomeMy WebLinkAboutProduct Approval 11128f2Q16 Florida Building Code Online ue... ,. ,., k SCtS tiarne Lay fn lir fetystratian i Hat ibpits t Submit Surderp 4 Stats 8 Fads } Pubfiiradam FK Staff 4 BM Site Map y links , Seardr Fk ncb rO., Product Approval S; USUL-Pubic User S��GraX:3�i'��R�Yi Product Appmval Menu>Pr°dad or Application Search>Apr4ication List>Appl(tation Detail FL.# FL5444-119 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer CertainTeed Corporation-Roofing Address/Phone/Email 18 Moores Road Malvern,PA 19355 (610) 651-5847 mark.d.harner@saint-gobain.com Authorized Signature Mark Harrier mark.d.harner@saint-gobain.com Technical Representative Mark D.Harner Address/Phone/Email 18 Moores Road Malvern,PA 19355 (610) 651-5847 Mark.D.Harner@saint-gobain.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received nonda Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 07/03/2017 Validated By John W.Knezevich,PE 's Validation Checklist-Hardcopy Received Certificate of Independence FL5444 R9 COI 2016 01 COI Nieminen.Ddf Referenced Standard and Year(of Standard) Standard Year ASTM D3161,Class F 2009 ASTM D3462 2009 ASTM D7158,Class H 2008 Equivalence of Product Standards Certified By Sections from the Code hripsJ/www.flaridablrilding org/pr/pr_appO.aspx?param=wGEVXQwtDratah1g07CSsoycOr128CcpCIS%2f�cD10m5s°lp3d 1/2 11/2812016 Fludda WIding Code Online Product Approval Method Method 1 Option D Date Submitted 07 1612016 Date Validated 02/16/2016 Date Pending IBC Approval 02117/2016 Date Approved 04/12/2016 SummarV of Products Ft # Model,Number or Name Description 5444.1 CertainTeed Asphalt Roofing 3-tab,4-tab,strip(no-cut-outs),laminated and architectural Shingles asphalt roof shingles Limits of Use Installation Instructions Approved for use in HVHZ:No FL5444 R9 H 2016 02 FINAL ER CERTAINTEED Asphalt Approved for use outside HVHZ:Yes Shingle FL5444-R9.pdf Impact:Resistant:N/A Verified By:Robert Nieminen,PE PE-59166 Design Pressure:N/A Created by Independent Third Party:Yes Other.Refer to ER Section 5 for Limits of Use Evaluation Reports FL5444 R9 AE 2016 02 FINAL ER CERTAINTEED Asphalt Shingle FL5444-R9.pdf Created by Independent Third Party:Yes SacR Prext Contact Us::2601 Blair Stone Road.Tallahassee FL 32349 Phone:850-987-1824 The State of Florida is an WEED employer.Copyright 2(07-2013 State of Florida.::Privacy Statement::Atcessibirrty Statement:.,Refund statement Under Florida law,email addresses are public records If you do not wart your e-mail address released in response to a pub0o-nennds request,do not send electronic mal to this entity.Instead,contact the office by phone or try traditional mail.If you have any questions,please contact 850.487.1395.int to Section 456.275j1),Florida Stables,effective October 1,2012,lirsnseestoansed under-Chapter 455,F.S.must provide the Department with an email addles;it 40"have one.The emals provided may be used for official communication ation with the licensee-However email are public record.If you do not wish to sup*a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under chapter 4SS.F.S.,plazse dick hie. Product Approval Accepts. Credlt Card Safe httpsJ/www.flcridabuilding.org/pr/pr app dffimpx?param=wGEVXQwtDgtahlgO7CSsoycOr128CcpCISg/gA3bcD1Om5s°/g3d 212 W280116 Floridly Building Code Offline (XP RMI:Hone 4 Lzq fit i User fm d Hat Ttlpifs f SW=ft SY¢d¢rg StM 8 Fans t � 3 Mc Staff j am Sfi'Flap { Lucks j Search a 3 . Y` Ig Iu Product Approval tUSER:Public User Product Approval Menu>Product or Aonlication Search>Application List - � Search Criteria Refine Search Code Version 2014 FL# ALL Application Type ALL Product Manufacturer CertainTeed Corporation-Roofing Category Roofing Subcategory Asphalt Shingles Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model,Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ AU- Impact LLImpact Resistant ALL Design Pressure ALL Other ALL Search Results-Appfkcaflons IMg Manufacturer validated 8 status FL5444-R9 Revision CertainTeed Corporation-Roofing John W.Knezevich, PE Approved History Category:Roofing (954)772-6224 Subcategory:Asphalt Shingles "Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Conrad Its::Mill Blair SbNw Read,Tallahassee FL 32399 Phone:893487-1824 The State of Florida Is an AARM employer..Cawright 201I7-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Wilder Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send elec rook mail to this entity.Instead,contact the office by phone or by traditional mail.If you have arty questiom,please corrtact 85o.487.M9,*Pposmnt to Sedion 455.275(1),Florida Stites,effective October 1,2012,licensees licensed under Chapter 455,FS.must provide the Department with an mail address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455,F,S.,please dick here. Product iApp—al Accept- Credit Car"tl Safe . h1M:is9/wwwJlon labtelding orW1pr app Ist aspx 111 MIAMF lDE ii11AMI RADE COUNTY ePRODUCT CONTROL SECTION 11805 SW 26 Sh=t Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidade eavimenumy Interwrap,Inc. 32923 Mission Way Mission,BC,Canada V2V-6E4 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials_The documentation submitted has been reviewed and accepted by Miami Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control Section (fn Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Titanium®UDL-25 PLUS,Titanium®UDL-30,Titauium®UDL-50,UDL TT,UDL TF, UDL TTMC-300,RhinoRoof U10,RhinoRoof U15,RhinoRoof U20,Titanium UDL25,and RhinoRoof RSA Synthetic Underlayments 1 ABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement:"Miami Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 13-0610.01 and consists of pages 1 through 5. The submitted documentation was reviewed by Alex Tigera. NOA No.:14-0603.18 r+wMMADEcoUNrr Expiration Date: 08/08/18 Approval Date: 06/11/15 Page 1 of 5 ROOFING COMPONENT APPROVAL Ca a : Roofing Sub-Catmory: Underlayment Material: Polypropylene SCOPE: This acceptance is for Titanium'UDI-25 PLUS,Titanium®UDL-30,Titanium®UD1-50,UDL TT,UDL TIS', UDL TTIVIC 300,RhinoRoof U10,RhinoRoof U15,RhinoRoof U20,Titanium UDL25,and RhinoRoof RSA Synthetic Underlayments as described in this Notice of Acceptance,for use with approved prepared roof assemblies where ASTM D226 Type underlayment is specified and installed with prescribed approved fasteners and fastener densities.Designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code PRODUCT DESCRIPTION: Test Product Product Dimensions Specification Description Titauin4I UDL-25 PLUS 48"x 250'rolls ASTM D226 Woven synthetic polymer underlayment with one Manufacturing Type I&lI side coated with UV protected and slip resistant Location#1&#3 polymer stabilized polypropylene on both sides. Titanium'UDL-30 48"x 250'rolls ASTM D226 Woven synthetic polymer underlayment with two Manufacturing Type I&H sides coated with UV protected and slip resistant Location#1&#3 polymer stabilized polypropylene on both sides. Titanium®UDL-50 48"x 250'rolls ASTM D226 Woven synthetic polymer underlayment with two Manufacturing Type I&H sides coated with UV protected and slip resistant Location#1&#3 polymer stabilized polypropylene on both sides. UDL TT 48"x 250'rolls ASTM D226 Woven synthetic polymer underlayment with one Manufacturing Type I&lI side coated with UV protected and slip resistant Location#1 polymer stabilized polypropylene on both sides. UDL TF 48"x 250'rolls ASTM D226 Woven synthetic polymer underlayment with two Manufacturing Type I&H sides coated with UV protected and slip resistant Location#1 polymer stabilized polypropylene on both sides. UDL TTMC-300 48"x 250'rolls ASTM D226 Woven synthetic polymer underlayment with two ,Manufacturing Type I&H sides coated with UV protected and slip resistant I Location#2 polymer stabilized polypropylene on both sides. RhinoRoof U10 42"x 286'rolls ASTM D226 Woven synthetic polymer underlayment with two Manufacturing Type I&11 sides coated with UV protected and slip resistant Location #3 polymer stabilized polypropylene on both sides. MQAMH]AQE CNOA No.:14-0603.18 OUNTY . , Expiration Date: 08/08/18 Approval Date: 06/11/15 Page 2 of 5 RhinoRoof U15 42"x 286'rolls ASTM D226 Woven synthetic polymer underlayment with two iaanufactin,hig Type I and U sides coated with UV protected and slip resistant Location #3 polymer stabilized polypropylene on both sides. RhinoRoof U20 42"x 286'rolls ASTM D226 Woven synthetic polymer underlayment with two Manufacturing Location#3 Type I and U sides coated with UV protected and slip resistant polymer stabilized polypropylene on both sides. Titanium UDL25 48"x 250'rolls ASTM D226 Woven synthetic polymer underlayment with two Manufacturing Location#3 Type I and H sides coated with UV protected and slip resistant polymer stabilized polypropylene on both sides. RhinoRoof RSA 36"x 67'rolls ASTM D1970 Unreinforced polymer modified bitumen material Manufacturing Location#4 adhered to the underside of a polymer-coated, synthetic woven sheet. The underside is backed with a release film MANUFAC7URING LOCATIONS: 1. MLI 2. ML2 3. M13 4. ML4 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Intertek Testing Services #3031783 TAS 104 02/19/03 3119607COQ-003B ICC-ES AC48 02/20/08 3124826-01. ASTM E108 02/19/08 3124826MED-007 ASTM El 08 02/25/08 311801 OCOQ-003 ASTM D226 02/20/08 3130639COQ-002A ASTM D226 02/20/08 3146738COQ-003A ASTM D226 06/20/11 3146738COQ-003B ASTM D 1876/TAS 117 03/28/08 101465036COQ-001 ASTM D1970 06/27/14 100539395COQ-006 ASTM D226 06/02/14 101863861 COQ-001A ASTM D226 10/28/14 101823107COQ-011 ASTM D226 12/09/14 Trinity I ERD I15010.05.10 ASTM D4798/D226 05/14/10 138010.08.11 ASTM D226 08/11/11 I35520.08.11 ASTM D2523/D1781 08/17/11 NOA No.: 14-0603.18 ranaaE couly Expiration Date: 08/08/18 Approval Date: 06/11/15 Page 3 of 5 i INSTALLATION SPECIFICATIONS: Titanium' UDL-25 PLUS, Titanium@ UDL-30, Titanim® UDL-50, UDL TTMC-300, UDL TT, UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments 1. Titanium@'UDL-25 PLUS,Titanium'UDL-30,Titanium'-UDL-50,UDL TTMC-300,UDL TT,UDL TF, RhinoRoof U10,RhinoRoof U15,RhinoRoof U20,Titanium UDL25,and RhinoRoof RSA Synthetic Underlayments shall be installed in strict compliance with applicable Building Code. 2. Titanium@ UDL-25 PLUS,Titanium UDL-30,Titanium UDL-50,UDL TTMC-300,UDL TT,UDL TF, RhinoRoof U10,RhinoRoof U15,RhinoRoof U20,Titanium UDL25,and RhinoRoof RSA Synthetic Underlayments shall be installed with a minimum 4-inch head lap in a shingle layer fashion. 3. Titanium`'UDL-25 PLUS,Titanium®UDL-30,Titanium'UDL-50,UDL TTMC-300,UDL TT,UDL TF, RhinoRoof Ul 0,RhinoRoof U15,RhinoRoof U20,and Titanium UDL25 Synthetic Underlayments shall be fastened with Miami Dade approved corrosion resistant tin-caps and 12 gauge 1 '/4"annular ring shank nails, spaced 6"o.c. at all laps and three staggered rows fastened 12"o.c.in the field of the roll. 4. Titanium'UDL-25 PLUS,Titanium'UDL-30,Titanium@ UDL-50,UDL TTMC-300,UDL TT,UDL TF, RhinoRoof U l0,RhinoRoof U 15,RhinoRoof U20,Titanium UDL25,and RhinoRoof RSA Synthetic Underlayments may be used with Asphaltic shingles,Wood shakes and shingles,Non-structural metal roofing, and quarry slate.Titanium`°UDL-30,Titanium@ UDL-50,UDLTTMC-300,UDL TT,UDL TF,RhinoRoof U 10,RhinoRoof U 15,RhinoRoof U20,Titanium UDL25 and RhinoRoof RSA Synthetic Underlayments shall not be used as roof tile underlayments. S. For Roof Tile applications;Titanium@ UDL-25 PLUS may be used as an anchor sheet in roof file applications when used in combination with a top membrane layer,consisting of a Miami-Dadc approved TAS 103 self- adlicring undcrlaymcnt.(Scc current NOA listing of approved TAS 103 self-adhering undcrlaymcnt for installation guidelines and limitations of use). 6. For fire classification of specific roof assemblies using Titanium'F" UDL-25 PLUS, Titanium`s UDL-30, Titanium@ UDL-50,UDL TTMC-300,UDL TT,UDL TF,RhinoRoof U10,RhinoRoof U15,RhinoRoof U20, i Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments refer to a current Approved Roofing Materials Directory for fire ratings of this product. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this material. NOA No.:14-0603.18 �ntuwt zulz COUNTYNOA Date: 08/08/18 Approval Date: 06/11/15 Page 4 of 5 y � IAMITATIONS: 1. Fire classification is not part of this acceptance,refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. Titanium UDL-25 PLUS, Titanium' UDL-30, Titanium® UDL-50, UDL TTMC-300, UDL TT, UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments shall be applied to a smooth,clean and dry surface with deck free of irregularities.All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 4. Titanium`s UDL-25 PLUS, Titanium? UDL-30, Titanium® UDL-50, UDL TTMC-300, UDL TT, UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments shall not be hot mopped,refer to manufacturer's published literature for product compatibility. 5. Titanium' UDL-25 PLUS, Titanium's UDL-30, Titanium® UDL-50, UDL TTMC-300, UDL TT, UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments shall not be applied over an existing roof membrane as a recover system. 6. Titanium UDL-25 PLUS, Titanium UDL-30, Titanium UDL-50, UDL TTMC-300, UDL TT, UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments shall not be left exposed as a temporary roof for longer than 30 days of application. 7. UDL TMC-300 Synthetic Underlayment shall not be left exposed as a temporary roof for longer than 180 days of application. 8. Titanium's UDL-25 PLUS, Titanium' UDL-30, Titanium® UDL-50, UDL TTMC-300, UDL TT, UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments are components used in roof system assemblies.Roof system assemblies are approved under a specific Notice of Acceptance. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 9. Titanium' UDL-25 PLUS, Titanium' UDL-30, Titanium' UDL-50, UDL TTMC-300, UDL TT, UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments may be used with any approved roof covering Notice of Acceptance listing Titanium'UDL-25 PLUS, Titanium"s UDL-30, Titaniume UDL-50, UDL TTMC-300, UDL TT, UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments as a component part of an assembly in the Notice of Acceptance. If Titanium's UDL-25 PLUS,Titanium UDL- 30, Titanium'UDL-50, UDL TTMC-300, UDL TT,UDL TF, RhinoRoof U10, RhinoRoof U15, RhinoRoof U20, Titanium UDL25, and RhinoRoof RSA Synthetic Underlayments are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products;wind uplift resistance,and fire testing results. 10. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. CNLAMHW=2ADEC0=UNMW 11. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.:14-0603.18 MIAMFDADfi COUNTY Expiration Date: 08/08/18 Approval Date: 06/11/15 Page 5 of 5 EXTERIOR RESEARCH&DESIGN,LLC tertiftcate Of AuthoiizzoGon#9503 TR.1N1TY:`ERD' 353 CHRISTIAN STREET,UNIT#13QXFORD,CT 06478 P.HONEt(203)2627,9245: FAX:(203)262-9243. EVALUATION REPORT CertainTeed Corporation. Evaluation Report 3532.09.05=1110- 18'Moores Road. _ FM44-R9 Malvern,PA 19355 Date of Issuance;09/22/2005 Revision 1002/16/Z616 SCOPE: This Evaluation.:Report is,.issued under Rule 61620-3 and the applicable'rules. and.regulations governing the use.of construction materials in:the:State of.Florida.The documentatlon.submitted has been reviewed:.by-Roberk.Nieminen,P.E.for, use of the product.undee the Florida'Buildmg.Code:and Florida Building Code,.Residential Volume: The products;described .. herein have.been evaluated for compliance with the 5'Edition(2014)Florida Building Code sections noted herein: :DEscRIPnom CeitainTeed Asphalt Roofing:Shingles.. LaBEunto. tabehng:shall be in accordance with the requirements of the Accredited:Quality Assurance Agency noted herein and FBC 1507.2.1.1 .. CONTINUED COMPLIANCE:. This Evaluation Report is.valid until:such time as the named products) changes; the referenced C!uality Assurance•.documentation changes,or provisions of the;Code.that relate to.the product change..Acceptance of this Evaluation Report by:the named client constitutes agreement tO.notify Robert:Nieminen;P.E :if.the,prOduct changes or the referenced.Quality Assurance documentations changes TnnityIERD requires a-complete:;review of this Evaluation Repprt ; .relative to.updated Code nr tlWrements with`each Code Cycle:: ADvamsEmEW: The Evaluation Report number preceded-by the words:"TrinitylERD Evaluated" may be displayed. in advertising literature: If anyportion of the Evaluation Report:is;displayed;then it shall be.done.in.its entirety: (N5PECTION:'Upon request;a COpyOf.thiS enfire.Evalu.ation:Report,shall be provided.to the'user by the manufacturer or its distributors.and shall.be available;for inspection at:the job site at the:requeAt 6f;the Building Official: This Evaluation;Report consists of pages l through 12. :Prepared by: Robert)M Nieminen,.P.E: ne��sealappearirewwa4horizadbyEugmnN,emmen, ' - Ps-an 02/16/2076.This does not serve as an elecfmnicaliy s�gd.'.. Florida.Registration.No.:59166;;Florida DCA:ANE1983 t ,, r� , a;:�7 d«Vmentsteed,sealedtnrd�opieshavebeentermedtothe: .__ .. ..di,Tn,ar s` ProductAPprovalAdm4nistratorand tothenamediLent CERTIFICATION OF INDEPENDENCE: 1 Trinity.)ERD does-not have,.nor.does it intend to acquire or�n►ill it acquire,a.financial.interest:in any company manufacturing.or distributing products it evaluates. 2 Trinity I ERD Knot owned,operated or controlledby any company manufacturing or distributing products it,evaluates_. 3 , .Robert Nieminen,.P.E.does not have,norwill.acquire,'a financial interest in any co mpany.manufacturng or distributing products for which the evaluation reports are beinglssued: 4: Robert Nieminen,P.E.does:not.have,nor will acquire,a financial Interest in:any other entity involved in the approval:process of the product.:. 5. -This is a building:code evaluation. Neither:Trinity(ERD nor Rob KE.are,,in any way;the Designer of`Record focany: Project on which this Evaluation.Report,or previous versions thereof,is/was used'for permitting'or design guidance unless retained specifcallyfor that purpose"_. 1� 1 I1� ERS ROOFING SYSTEMS EVALUATION 1. .::SCOPE:, Product Category, Roofing Sub-Category: Asphalt Shingles Compliance Statement;': :CertainTeed Asphalt Roofing Shingles,as`produced by CertainTeed Corporab6n have demonstrated compliance with the follolraihk sections of.the Florida Building Code:and Florida Building Code,Residential Volume through testing in accordance with the foiiowing:Standard& Compliance issubjectto:the installation Rouwrements and Limitations)Conditions of Use set forth herein. Z ` :STANDARDst Section , . Pra er Standard Year 1507.2.5,11905:2:4 Physical Properties ASW D3462 2009 1507,2.7:1,R9U5:2 6,i WindResistance ASTM-D3161.Class,F: :: 2009 1507.2.7:1,11905.2.6.1 Wind Resistance ASTM p7158 Class N 2008 3.:. REFERENCES Enti Examination Reference : date: UL(TST 1740) ASTM 03161:: 941U.9632 05/15/1998 UL(TSi 174(1) ASTM 03161: 99NK26506 11[23/1999 UL(TST,1740) ASiM 03161 03CA12702 05/27/2003: UL_(TST 1740). :. ASTM:0316103CA12702 06/16/2003 UL(TST1740) ASTM D3161: 03NK29847 ': 10/03/2003 MUST 1740) ASTM D3161 "CA 32 05/24/2004 UL(TST 1740): ASTM D3161 "04CA32986 12/03/2004 UL(TST 1740)_ . ASTMD3161 05NK07049 : - 04/15/2005 UL(UT V40). 'A5m,63161:. 05NK16778 05/12/2005 UL(TSr 1740): ASI M:03161.` 05CA16778 05/12/2005 UL(T5T 1740) ASiM.03161.. 05NK14836 05/22/2005 UL(TST 1740) : ASTM D3161:: 05NK22800 06122/2005 UL(TST 1740).: ASTM D3462 11684 09/21/2005 (TST 1740) ASTM 07158. 05iVK08037 06)28/20 UL 06 V1,(TST 1740) ASTM:D3161:&D3462 09CA28873 07/23/2009 (JL(TST 1740) ASTM D3462': 10CA41303... 14/07/2014 UL(TST 1740} ASTM D3161' 10CA41303 16/08/2010 UL(TWT 1740) ASTM 07158. 10CA41303: . 10[27/2010 UL(TST.1740) ASPM D3161&0346.2 10CA44960 :. 11/11/2010. UL LLC(TST%28)_ ASTMD3161„D3462;&D7158:. 13CA32897 11/21/2013 UL LLC(TST 9628) ASTM D3161 D3462- TFWZ:R684 04/22/2014 UL LLC(TST 9628): ASTM 07158' TGAH R684. 04/22j2D14 UL LLC(TST 9628): ASTM.031b1&03462: -: : 4786334434`: 05/16/2014 UL LLC(TST 9638):. ASTM D3161&D3462 4786570826 02%12/2015 UL LLC(TST 9628) A5TM.D3161,.D3462:&.D7158: : 4786570717 12/16/2015 UL LLC(TST 9628). ASTM 03161`&03462` 4787195678: 02/09/2016 UL LLC(QV 9625) Quality Control Service Confirmation Expo aT/o312017 4 PRODUCT DESCRIPTION; 41 CT20"',XT-.25,XT-:30 and:X7' 30111 are fiberglass reinforced,3-tab asphalt roof`shingies: 4.2 Carriage House Shangleg,.;Centennial .Slate'°', Grand Manor' Shan9le , Landmarklm Landmark'" iR, Landmark'" Pro,.Landmark"" Premium, Landmark1°' TL, Landmark' Solaris and.landmark'"' Solans IR are. fiberglass reinforced;laminated asphalt roof shingles. 4.3 NorthGate"'is a:fiberglass reinforced,lamlrlated,5BS modified:bitumen roof shingle. Exterior Research and;Design LLG Evaluation Report3532.09AS-R10 Cerw6gw oT Authonza6on#9509 F15�i44R9 Revision I0r02/16/2011, Page 2 of12 R TRINITY 4.4 Presidential Shake'",Presidential Shake's IR Presidential Shake TL7 and Presidential Solaris"°are fiberglass, reinforced,.architectural asphalt roof:shingles:. .4.S. Hatteras" Highland Slate m:and Highland.Slate!m IR are.fiberglass reinforced;4-tab asphalt.roof.shingles 4.6 Patdotw is.a:fiberglass reinforced asphalt:roof strip-shingle-(with no cut-outs) providing_ as laminated, appearance through.an intermittent shadow line with contrasting blend:drops forcolor definition. .4:7 Presidential;:Accessory, Accessory for Hatteras, Shangle Ridge"'; Shadow Ridge"', Cedar:Crest""; Cedar Crest'" IR;_NorthGate Ridge and NorthGate Accessory.are fiberglass reinforced accessory shingles for hip and.ridge installation. 4 8 Any of the abovelisted.shingI smay be produced:in AR(algae resistant)versions:. S; LVATTAT1ONS; 5.1 This is a.building code evaluation. Neither TrinityjERD nor Robert Nieminen;P.E:.are, in.anyway;the Designer of.Record-for any project on which this Evaluation Report, orprevious versions thereof, is/was used for permitting or.design guidance unless retained specifically.for#hat:purpose: 5:2. This.EvaluationReport is notfor.use.in the.,WVHZ 53 Fire.Classification is not part of this Evaluation Report; refer to current Approved Roofing 'Materials, Directory for fire ratings of this: 5.4 Wind Classification:. 5:4.1. All shingles noted:herein are Classified in accordance with FBC:Tables 1507.2-7,61 and R905.2.6:1 to ASTM D3161,Class F an dJor ASTM D7158;.Gass H, indicating theshingles are acceptable for us.in all wind zones . up to Vm=150 mph (V, 194.mph). Refer:to Section 6 for installation requirements to meet this.wind rating. 5.4.2 Presidential Accessory,Accessory'for Hatteras,Shingle Ridge;Shadow Ridge;:Cedar Crest;NorthGate Ridge. and NorthGate Accessory hip&,ridge shingles have been.evaluated.in:accordance with ASTM D3161;.Class F. :All except.NorthGate::Ridge.and North Accessory require use.of BASF Sonolastic NPI adhesive or Henkel PL® Polyurethane Roof &. Flashing Sealant, applied-as specified in manufacturer's application instructions; for use.in wind zones up to:V�=.150 mph(V„it:-194 mph). 5.4.3. Classification by ASTM D7158 applies to exposure category.B or.C:antl a:•building height;of.60;feet.or less. Calculations by a qualified-design professional.are.-required for conditions outside,these limitations.: Contact the shingle manufacturer for data specific to eachahingle. 5 4 3;1;. Analysis in accordance with,`AST..M D7158 indicates the measured uplift resistance-:(RT)forthe;CertainTeed asphalt roofing shingles listed:in:Section.4.1 through 46'(except Presidential Solaris:-) exceeds.the calculated uplift force (FT):at a,maximum.design-wirid-speed of V,s = 150 mph (V.it'=.194.mph) for residential buildingslocated;in:Ex osure D conditions with:no:to p pographical variations(flat terrain)having : :. a mean roof'height]ess than or equal to 60feet. sl The shingles are permissible:..under Code for installation in.these:conditions :using the installation procedures. detailed. in this Evaluation. Report and CertainTeed minimum requirements; subject..to minimum 'codified. fastening requirements established within any locale jurisdiction,,which: shall take :precedence: : 5.5' AlLproducis in the:roof assembly shall have:quality assurance audits in accordance with the Florida Building Code and F.A.C.Rule 61G20=3. 6: -.:INsrALLAMON: 6.1_ Roof deck, slope, underlayment and fasteners shall :comply with FBC 1507.2 / 8905:2 and the shingle manufacturer's minimum requirements. Exterior Research and Design,LLC. Evaluation Report 3532.09.05410 rnte o Autliorimtion 69503 FL54"R9 - Revision 10:02/16%2016` Page 3_of'11 0 ERD 3 6.11 Underlayment shall. be acceptable to Cer'tainTeed`Corporation:and "I hold;current Florida.Statewide Product Approval,: or be Locally:,Approved per Rule'61G2O 3 .per FBC Sections 1507:2.3, 1507.2.4-or . R9O5:2.3. 6.21 Installation of asphalt shingles shall%comply,with the manufacturer's current published instructions,:using. minimum four(4)Waits pes shingle in accordance:,ra A FBC 1507.2.7 or Section 1190-5 2.6 a»d the. mi»imam requi remenis.herein 6.2.1. Fasteners., shah be in accordance:with :manufadurees:"published requirements, but not less than...FBC 1507:2.6 or.R9O5 2.5: Staples are not permitted. 6.2.2 Where the roof slope"exceeds 21 units vertical in 12 units hor¢ontal,use the"Steep Slope"°directions 6.3 CertanTeed;asphaltshingles ars acceptable for use in reroof(tear-off)or recover applications,subject toahe limitations set forth;in FBC Section 151O and`certainTeed published i»staliation instructions 6.341: MO71 XT''e°n XT-30.XT-30 IR:- LOW AND ST 0100 SLOi'E STEEP SLORE : ENGLISH 12':": 12 12 Usrfonrf, {305 rrnj-+ {3tl5 tmn} (305 nupj-�{ shin'gte(Rigors 11-4).. rooting cement meeting;a$Tbi D458& 1 ( mm} Sealant t ( Vii} TYttc li is suglea 5 tt2 Pa ——— —— —"—— METRIC jsls,: 3tfs =.if 13tls` Roofing Cement (2a tnmj Sealant 1 (25 mi Rppfyl'{25aanl JpoL of aspl alt ro4li�g nen[ - UndettaCh fab ra(net. 6; •; fdgtirsll�i"ttrafo�rna�fsruuJs£rsjwdsofnspller�aardoasdaistrja dCAUTIO�L•`Eecessire-use of roating cement can causestiingles to blister, ffigrirs 11 3:trs�+fournails;�,ret�ryfdllsbkr�e:: 6.3.1.1 Nip&Ridgei Cut Shingles (25' .: �t_j� �,rRemrne ,�, {► 12 ( mm} � i25 yaes mn•\ 305mm} Shdngte Sit�ngte 'S�tngte sho�m . : 5518 ml Dexo �a1`,l Ixaure'I""l=?rt(.ltd d�lzs;dl7t drinx:bracE_Yo»t®Le sGsu N ��1A5 m aQ (rsgksbdh�rertsimsssEmast); ��,{? Flgu,Rt 112�-Iru(alladesn bfcpps dlorig tUe bdps mal rldyes: ..". . . . Note::For ASTM W161 Class F, use BASF:.Sonolastic NP`1 adhesive or.Henkel':PL® Polyurethane Roof.& Flashing Sealant,inaccordance with:manufacturer's:instrtiions_ Exterior Research and;Destgn;LLC. Evaluation Report 3532,09 05 RIO [er6JartenfAuthonioGugg9503.:' ":' 145494-R9 : Revision 10'02/16/2016 Page 4 of 11' W- �iNITYIERD.. . 6.3.2 Carriane House Shani;lee,Centennial Slatdl and Grand Manor Shani=leec lOW AND: STEEP SLOPE,.. . STANDARD SLdPE rrespots of asphalt roofing cemear.foi etrr} l tie scn m nails and th full Grand�fanorSiutngle.:use Cine uail<and three spots a[asphall use lire nails[or cher}(ull Shangle,:. roofing cen e�ri?.(ul(farri3ge Hoa i6f for ce Shanglc aqd Centrnmal qe:Apply asp6aii.rooGog eelnen(1'(2>mm)f�oin etl��e;of shmglc:° (Fl uw175):Asphalt roofing cement m�rUag;4S[�f Wi58f,:71peif V' i is cnestrd., miri). (16nan} 122Unun) . t}S tion} (25tmm) F iue 17�•tue irr nails area n11 Grrur!Slirr'orSlrrui+ � �_ g f . I �l �_ sra g�B•• (darraer�e:/l�{utas(�rngle;;orGi+nlenulalSlW. {,S6'rrum)�t �� (227 mm} 125rten) "Odwgcametd Rgure 1;7-5.-R7eminstaffliig Grn+til:1/anor5bamgtm on steed sloA wsffea natlsrurd lkmdmfs ofa*ball roiifrng wnienl. 6:3.2.1 Nip&,Ridge:Shangle®Ridge 12. 18Exposure ,' Rernove tape from the right.side and fasten SECOND Fasten theme deft side RIGHT Remove.. 3has Tape: : FIRST LEFT' � oSg � (ge skl i lesF,trr17,19 hlstnllltidtfcRd Rgre.17SGangleAte on hips an.d'ridges. Note: For.ASTM 33161 .loss F, use:BASF Sonolastfc NP 1 adhesive or Henkel PL® Polyurethane Roof.&; Flashing Sealantin accord..ence:with manufacturer's instru. tons., Exterior Research and Design,llC. .. Evaluation Report 3532.09.05-R10 Catifrcwte ofAud�orirctioii u95o3: FLS"4-M RevisiorrJOc 02/16/2016 Page 5 of 12' TFUNITYJERD. 6.3:3 .. Landmark"';.landmark" 1% Landmark o Pro '(formerly landmark'" Ptus). Landmark'" Premium,. Landmark"'.Ti;landmark'Solaris,Landmark'"Solaris IR,NorthGatec LOW AND.STANDARD SLOPES: METRIC I)IJAWSIONS .14.. 1 mm).; (345 mm}-►� '� 1 (25 mm) Release Tape 1 (25 mmj Na�fable� ,_ Area LANDh1ARK;TI. 13th 13" 13tPz' mm)-• -(33Q:mm) }- (343 mm)-►� 105 mm -► �- y .. Gigurl3 fraJ.�ejorrr�{nilsfore�e�•frrlls�ii{�le., NorthGate %UD tiaarca t2" tura. 1r a3lEA (305 mm).-a (375 mm) -i -(305 mm) r Ra1ng Lr's t +-1..(25 mm) 'ppe nai lre . .r(25 mm)-► Jam liaArtg areae for layv and stamlard sbssas 4 '+2;12 m 2112):. N31 tie;a�nu{q�rB Frn�;trss�3ss' tsabtn�. Use six n tils:'w fonts.w o.asphah rooGngcemen'for everiy'fiill` - Iaminalm sh in Asphalt ioo!)nv0emshouldpiect A'TAtD4586;a}pc it;1pply I spo(s of a3pLalt roofing cenrent:itarli each corner stud a1 aliont t2"1o't3"inYront.each ed ec METRIC:DIMENSIONS 1 r,25 rran. t ReleasATape; I:. NO keal - 05 inm} - (25(n Roofing Cement Exterior Research and.De§i n,LLC: Rl1Evaluation Re . . S GeWP-mW ofAUMorizption#Z03 F15944R9: Revision lOc 02/16/2016; Page 6 of 12' LANDMARK,TL 343.mmY (330 mm) {343'mm iTO1 t: l (25mm 1+— -- (25 mm) Roiling CementI. Feg►t 13S,Uslesixrr.09?dp!4fONS of, . aspG�ttioo,ffngcenre�ton sfaeps(o�ac NorthGatec NEEP 12" 14-3/4" 12° SLOPE_. [- (305 mm ---(365 nirrrr ----(305 mm}-►1 NAILING —.(3755Npi' ImitsAREAt1 oween ,r wmm) 1 (25'mm)es. 7. Roo { ,ng ement. ailing areas.far steep slopes:(greaier than 21 12) and"StonniNailing,�. . Nail Ww6en lower 2 na16nes as,shown above, 6.3:3:1 Hip&Ridge;Option 1: Shadow Ridge"'or Noth.Gate Accessory. . Rpre 1316 Shadmn Rtdi,ac�ory sbfngles lkwb;eu 45jy o» r[rrtts b nra@e72tvrdivl i4d- ippkua 12' 97Pg° (305mm)' (250inm) G 8 -015/16°—►}�-41511fi (150mm) (iWmm): (125inm) I (125*n t' Notch for Pldchfor Cen(ermg: .`:. ;Centering' 12 13/4' (305mm) ` f (337mm) R°. PlotchrforA►ignmentto NotchesiorAlignmeMto 5 the Top Edge of the Prevbus T the Top Edge,of the Prevous (11l�nm)` (196mm?. Cap for F.(125mn)Expo§ue Captor5518'(i41mm)Exp�ti Eng i6b'Dimensi6n Metric Ditnensan ShadowAldge'0 Shadow Ridge"'' Exterior Research andbWgn,LLL Evaluation Report 353109.05-RIO CerbficaM ofAu�oriza�i�n p95D3.' FLS""-R9 Reyislon 10:02/16/2016. Page 7 of 12 .. T -INN Y[ERCP WWI {2SA Istat). 31S+1G'(125rttn) f 13:- --{333 mm) CertpGssl PJtch 4 165 mm)I 168'mm)�: to 114 A Align Centering S1DL"itCS to 1�p 7 131!4'" ` _ Notcti .. C C£ (337 mm) gSteneUSGAt415t< Align these 75V . I notches tap of . (184 mm) 1 edge of PneMioumcourse. Northdate Ridge:. NordlGate,Accessory i2.. . _Laymg NoOefi I E ) I( Agttre 13 20 64-49169nokm$to iasrttersbhtgkS on btpsand ifilge;mu4d 7o&mte ibe cor t arj 'Ozra Note For ASTM D3161 Class F of.Shadow RidgeTM;.use:BASF Sonolastic NP 1.adhesive or. Henkel PL®` Polyurethane Roof.&.Flashing Seala�It in accordance Wlth:manufacturee.s instructions :.6.3.3.2` Hip&::Ridge;Option 2; Cedar Crest7,Cedar Crest 'IR.. Use two fasteners pet.shingle. For-.the starter shingle,.:place fastener,1-Inch from each side edge and about 2-inch up from the_Starter.shingle.'S exposed butt..edge., For each ful,I Cedar Crest:shingle, place fasteners 8-5/8-inch up.from Its-exposed:butt:edge and l-inchfrom each:side',edge. w. Ma _ - . - - - Exterior Research and sign;.iit Evaluatlan Report.3532,09 05-R10 Ce/bTwuW of AuthorizdBon NM3; EL54?19-R9 _ Revision 16:02/16/.2016: Page 8 of'12 i � R4NITY�ERD Note: For:ASTM[)3161-Class F,use.BASF'Sonolastic NP 1 adhesive or Henkel PLS Polyurethane Roof'&. Flashing Sealant to.hand-seal Cedar Crest shingles.-: Apply:NP 1,or PL adhesive from the..middle.of the. shingle's raised overlay orr the:top.piece'and extending approximately`4-inch along:the sides of the headlap along a line%to;l-inch'from each side of the shingle's headlap: Immediately align and apply the overlying shingle;gently pressing;tab sides into the.adhesive,and install nails. To secure the.other side, apply a i-inch diametersot of of NO 1 or PLadhesive betwie'en the shingle layers. d (omni) w- 102mm 3ti _(25 ioml ...-' •fhv'Nj'i@tA•sZx: `6.3.4 Presidential Shake"" Presidential Shak6m IR Presidential Shake T&,PresidentialSolaris'"• LOW AND STANDARD SLOPS STFER:SLOPF For lou and standard slopes,use live nails for each.full presidential For steep slopes,use Nne.nalls for each Fall Pre�denilal shingle and shingle as shown;beloiti meter spots of asphalt roolll cemen apply l'dhii t utter each sldngle tab �fter'apPtft:$:nails lm belvreen die'naWtigguide lines;apply.4 tGails i Naiind: AO'— above tab cutouts ludUg ceitabi tabs of oter4ing"gkeoVer tudls Guide.luies (1016rnm) 51f4 . (133 inn) • A •• • • • iP2 nan} ( 1�} j NOTE Appry'natls on painted guideline Fig=lGd Fark�?ng.Presldendol`rmd Precldettwl TL Stenos 1'diameter aspliallrooting cement ' sLhigleson Fmnandsltmdme�s(opets RkjT16-7_F-ftivPwidenfiadatdPresldentfaf'TJL`S(n . sfrhtgtgs on s(-p lnpix 6.3.4:1.. Hip&Ridge;.Qption.l Pres dential'Accessory . PRESIDENTIAL ACCESSORY. Presidential accessoryslltigles.can be used for covering hipsand ridaes:.Apply:sliingles up ao the ridge (expose:no.more than 7'Pram. _ . the tiottonl edge of.the„tooth''Fasten:each accessory.with t.m#as: teners.The,fasteners Must be 1314'long or;longer,so they penetrate' either 3/47;Into the-deck.6 ompleelpIhrongh the.deck Presidential_ accessorycomes in two ditterent sizes..Accessory produced In . Blrmingham,Ai:.is•12•x 12 ,Portland,•4R<produces 9�/s'x131/4. accessory'_.. Note:For.ASTM D3161-Gass FuseBASF Sonolastic NR 1 adhesive or Henkel.PL® Polyurethane-Roof.& Flashing Sealant in accordance with mani facturel'sinstructions 6.3:4.2 tiny &:Ridge,.Option_ 2: Refer to instructions:herein for Cedar,crest , Cedar Crest'"' 'IR hip.and ridge - Exterior Research and:Design,UC Evaluation Report"3532.09.OrR10 Cer6]icate ojAuthorjWean nsm F75444-R9 Revlsion 30:02/16/2016 Page 9 of n. l"R{ {T . ERD 6:3.5 Hatteras'"': 10W'STMNDARIDAMDSTEEPSLOPE 1 worSm) .rnmm) I.(23om+o) ( min) 1 7' 9. I'{230 mm) 00mm). .tom►tnro): (230 W;) x(25 rcm) x(25 mmj (25 tnm)�. (2u1�n4 t w, —RaallogCemcot (240 mrnj F4an 15.#fWv)i{q llallemall Orep AM Forsicep slolxi;n e Gre nri3;ynd rlgle spins nf.ss�itiill taaGng . ' Fi/nor IS:3:dbYire�utg'I►�lirmx{611rkie ou crin�nifQrcarh tu13 ttutriis'�R�ia�rat sl�o��ti oiro�r,appijl LrmaradSSnir3imr57opes:.. (25eum}dzmacxr;jwt�nfroo6m Umrm(,bT f D.4S ?�1!�11" for**I slunk n).loipes,wefne niiik fdr rKb'60. sn Wed)nndrr t:'cli mb,rurnt Press sidn a into phce dr uW Iktlleru shingle t aMmti a"v. espose cemegL C t(iTlO�c_ibo much fooling ecmentrw causeshingles to bWer. . 6:3.5:1: Hip&Ridge;-Option l;Accessory for.Hatteras . 1 . Fasten 6nfti si>!�; err. 1 2 3 Figura 1514:;18 tGree prece rt iifs sepurnls fo mike 4Aa#er[rs9c�essU %s6�n mss:, �. Note: For ASTM D3161=Class F;use BASF:Sonolastic NP 1 adhesive or Henkel-PL® Polyurethane Roof& Flashing Sealant in.accordance with manilbcturer's instructions.' 6:3.5.2 Hip_Si Ridge;Option Z.Cut Hatteras.5hingles .-9 {230 m d6O mm) `. Cap CapCap,. Cap Stingie Shii►gle' Shingle ShinglF. e AI 15 2&cut liaftcfas sLinges fo:itia,FeCozy c�* F+„ttre3;j5-.21.-:Insid4dion'qf cstJu tslo>ig fl!/rs:,wd rfd�s Note: For ASTM':D3161.=Class F use BASF Sonolastic NP:1:adhesive or Henkel PL® Polyurethane Roof`& Flashing Sealant,in.accordance with.manufacturer's instructions. Exterior Research and.Design,Lit. Evaluation Report 3532.04 05=Rl0 G�tiTrcote ojAutllo�im6on►195D3: F1125444R4 Revision 10:02/16/2016: Page 10 of 32" ER 6.3:6 Highland Slate"',Miehland State"'!R: LOW AHR STANDAt;D;SlOP STEEP3LOPe g . ._ UseFlVEn2MandEIGlffSpota_ofz pitiooangcemenf=for each full:,Hlgidand SL�te shitigle:.For:ir>iamt Daae,Six nails are required; Apply 1'diameter spoil of:;tsptiaitrooling cement nndereacb lab . aet � cometc� AsphaltroaSngcnt meefutg ASIM D:4>.SG Yppe H is suggested::, t��d . 9X mstrxai�ffi 1•t2irsmj '., ' — SMrzt':s(fs1't25arnt 'wlaul as:Ywsn�: - Ffgurrs:f�•3t�u.+f11'Enallsfirct�r}1ll�E�lrmdS� sbt��le — pooihi9' - Flgrar if 3d:(lse Fl}Ti nail and eigk 001s ofasplall roAfnrg avitnt utuler earl'roli,iww.. •GAU'YfiN1._1v+ieessire nseot rnofing.cemenCcah cause shingles to blister 6 3 6.1. Hip.&Ridge,Option 1'Refer to.instructions:herein for Cedar C 6A-.,Cedar CreAl IR,or Shangle.Ridge'"' hip,and:ridge shingles. . 6.3.7 . 'r• .. Patriot .. - LOW AND:STANDARD SLOPE. STEEP3LOPE_ UseFOUR.nails.6r eveiy hill slIingle ,)cited t<ti.shown belo`t f3se FObR nail and font spots. nsph�lt coo ting cement far t ren_Self shipgk:ts shown Ixl0. kvil.ilt iuofMg c4 cwt tiieciing 1ti7;;\1 I}9586 .- 7ipe 11 i4 su �iKtexl, 1pp1} I'(25.mml spots of asphidt rrroling Sralira cm.enhts shown. t ; CAt"170N CSCCIM use of rool'mg cement can cause shingtes w blister itd+F-ri (r3rur) 1?5smmj L' r ssra':t 074 ' secs}" 1 RconOp Cement .. (oma). {3�rsaj Hip&Ridge Refer to mstructions.hereinlor•Cedar Crest' ,Cedar Cresfm IR,:- Shadow Ridge'",NorthGate or Shangie Ridge"'hip and ridge shingles.:: . 7. . .-LABEUNG: 7.1: Each. unit shall bear a permanent:label with the manufacturer's name, logo, city,.state.and logo of.the Accredited Quality"Assurance Agency:noted herein: 7.2 Asphalt shingle wrappers shall indicate compliance:with one of the required classifications.detailed'in.F9I Table 1507.2:7.1/_R905.2.6:1. Exterior Research and Design,.LLC_ Evaluation Report 3532 09 Os R10" CertifcaW cfAuthadzWon#950. 1:1.5444-119 Revision 10:1)2/15/2016: Page 11 of 12' 1�R1II1�( ERD 8.. BUILDING PERMIT REQUIREMENTS: As required.by the,Building OfFicial`.or Authority Having Jurisdiction in order to.properly evaluate the.installatiori of this product: 9. MANUFACTURING PLANTS: _ Contact the named QA entity for information on:wW plants produce products covered`6y Florida Rule'61G20-3'QA requirements: 10 QuALffyAssURANCE ENTITY.' UL LLC.=QUA9625;(414)248-6409;-karen.b6chmann@Us.ul:com END OF19VALUATION REPORT- Exterior Research end Design,LLC. Evaluation Report 3532.09.05 R10 GeitijOW of AnOhonza(ion g95o3 FOO-R9 - - Revision lo:A2/16/2016` Page 12 at 12'