HomeMy WebLinkAboutProduct Approval (2) . .
^- EXTERIOR RESEARCH &DESIG � LLC.
Certificate of Abrhorizntion#9J03
3S3CHRISTIAN STREET,UNIT#13
� �o ��[�
%���NI � � �^-���� OXFORD,[TO6478
' PHONE:(2O3l2G2'924S
FAX:(ZU3)26I-8Z4S
EVALUATION REPORT
Soprema,Inc. Evaluation Report S18010.06.09-119
1o*urue nagg= `v
0aten��summm�:W��l�/�oO�
DrummondviUe, Cm6bec]2[5P8
�e���'o�^ ��1��2Q1G
.Canada � , _,__,
ScOpEi.
This Evaluation Report.is issued under Rule 61G20-3 and the applicable rules and regulations govern'ng the. use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nienninen,
P.E. for use of pvodurtunder the Florida Building Code and Florida Building Code, Residential Volume. The
� Edition d�cts described herein have been evaluated for compliance with theS don (ZD14\ Florida Building [ode
pro� '
� 'sections noted herein.
DESCRIPTION: Smpmoxoa Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein. �
CONTINUED COMPLIANCE. This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation' Report 'by the named client constitutes agreement to notify Robert N(enninen^ P.E. if the product
changes orthe refenanbedQuality Assurance documentation changes. Trin|ty|ERDrequires acomplete review ofthis
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded bvthe words "Trinity|ERD Eva|uated" may bedisplayed in
odymrtisin8Utensturo' |fany portion ofthe Evaluation Report iodisplayed,thenitshaUbedoneiffitsentirety.
ImSpeCVum:Upoonequest,ouopyofthisontireEva|uatinnReportxhuUbeprovidedtotheuuorbythemanufa:tuperor
its.distributors and shall be available for inspection at the-Job site.at the req*uest of the Building Official.
This Evaluation Report consists ofpages 1through 7
Prepared by;
'
--__'
`
,
��*= by Robert
Robert JIM. ��snlnem, ~^~~~~~~~^,����� �� ------`a
^ ` P.E.' ^c=���z�v =u�°. �°°=�"=="�"
Florida Registration No.59150,Florida DC4 AIVE1983 document.signed,"ated hardeopies have been transmitted mthe
Product Approval Administrator and mthe named client '
CEm, ICArmmur|mocpcmoENoo`
1. TrInhY|Enodoes not have, nor does itintend toacqui,e.orwill it acquire, afinonua| interest in any company manufacturing ur
distributing products uevaluates.
2. Trinityl ERD is not owned,operated orcontrolled by any company manufacturing or distributing products it evaluates.
u. Robert Nieminen, P,E.does not have nor will acquire,a financial interest in any Company manufacturing or distributing products for
which the evaluation reports are being issued.
*. Robert Nieminen,PI.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
,
product.
s. This i, abuilding code evaluation. Neither rnnuv|snmnor Robert w|em|nen, p.s. are,many way, theoesignorofRecord for any
project on Which this Evaluation Report,-or previous versions thereof, is/was used for permitting o.r.dosign guidance unless retained
spedficaUyfor that purpose.
'
ROOFING COMPONENT EvAwAmON:
1. SCOPE:
Product Category. Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the Florida Building Code through testing in accordance with the f6flowing-Standards.
�
STANDARDS:
Section Property Standard Year
15043,1 Wind Resistance PN14474 2004
� 1507.3.4'1507.2.8' Physical Properties ASTM m197O znoy
1507.2.9.2,1507.4.5.1,
1507-5.3,1507.7.3
1507.11.2 PhvmicaiPmpemes ASTM D6'163 2800
�
1507.11.2 Physical Properties ASTM oa1a4 aVos
1523.6.5.2.1 Physical Properties TAS 103 1995
� T»Sz10 Accelerated Weathering TAS 110 2000
�
150'33 Installation Practice FRSA/TR|April Z012(04-z2) 2012
3. REFERENCES:
f1fty Examination Reference Date �
cno(rSTso4y) ASTM oz970/TAS 110 2568.05.04' 05/14/2004
suo(TST6O49) Physical Properties 2757.02.05 82/03/2085
sRo(TyTsu4y) ASTM oz97O/TAS zz0 I974.03'05�-2 05/17/2005
sno(TsTao4y) Wind Resistance 2778.07.05 07/15/2005
sRo(T5T6O4y) Wind Resistance 2779.11u5'nI 04/18/2007
' 8nD(TST6049) TAS 1os/TAS 110 s7120.11.07-2 11/02/2007
sno(TST6O49) xSTxom1y7n/TAS z1O 813190.02.09-xz 04/01/2010
soo(TST6o4y) ASTM mz37O/TAS 110 S31370.03.10'1'Mz 04/07/2010
sno(TST6V49) Physical Properties/Tensile Adhesion 511zsV-os.1u'Hz 09/09/2010
sRn(TsT§849) Physical Properties/Tensile Adhesion s11150.05.09'112 10/05/2010
sno(Tsrsa49) ASTM D197O S37218.11.11 11/09/2011
� sno(T3T6O49) ASTIND1970 s40540.02.13F1 02/z9/2023
� Eno(TSn5O«y) Physical Properties/Tensile Adhesion s43530.02.14-1 02/2-1/20z4
cnn(TsToo4g) Physical Properties/Tensile Adhesion S0pCSC7045.02.15 02/13/2015
s*o(TST6049) Accelerated Weathering SOpC-Sc8520.14 04/17/2015
m'D(CEn.1sez)' *v*zcump||ance 0e'1005'02 11/04/2010
xx-o<csn1592> *vnrcomp||ance 13'0530.02 11/I7/2014
|Cc'ss(sm2aye) zu1z.znuyand zOD6|ucCompliance sSn'1524 10/01/2014
Pn| (r3T5o78) Physical Properties sDp'06*-02-01 zz/o�'znzs
Sopnema'Inc.(poox3sz1) Equivalency Declaration sASMOOTH PLY 4O 05/29/2015
UL,LLC(OWA9s25) Quality Control Service Confirmation sxp.10/16/2017
4. PmOoUCrDESCRIPTION:
4'1 LaatobondTV HTisase|f-adhehng, non-woven polyester fabric surfaced, 583 modified bitumen roof
undedayment
4.2 Lastobond Shield is a self-adhering, vxnxen polyethylene surfaced, 3B3 modified bitumen roof
Undedaymentavailable intwo widths;36and 45inch.
4.3 RES|STOSASMOOTH PLY 40 is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
undedayment;available in3'3ftxG5ftrolls.
` |
Exterior Research and Design,I.I.C. Evaluation Report s18010.06u9-nn �
Certificate ofA"th"mau" ma03 pL2569-RzI
Revision szo/12/eoss
Page zuvv
^ ,
\ !
0 R0N1 ���� ��
X /��^a�
|
4.4 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced high temperature, SBS modified |
`
bitumen roof undodayment
43 Lastobond Pro HT-N is a se]fadhehng, woven polyethylene surfaced, SBS modified bitumen roof
undedoymentavailable intwo widths;36and 4Sinch.
4.6 Lastobond Pro HT-S is self-adhering, woven polyethylene surfaced, high temperature, SBS modified
bitumen roof underlayment'
� 4.7 Lastubond 195 is a self-adhering, glass-mat reinforced,. sand-surfaced, SBS modified bitumen roof
�
undedayment
4.8 Lastobnnd is o self-adhering; glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
undedayment
4.9 Laotobood Eco is a self-adhering, glass-mat reinforced, xond'surfaced SBS modified bitumen roof
' undedayment.
4.10 LogobcmdSmootb 3eo{ HT'is a self-adhering, glass-mat reinforced, fiim�surfaced, 3B6 modified bitumen
noofundadayment. '
4.11 RE8ISTO LB1236 is a self-adhering, glass-mat reinforced, sand*urfaced, SBS modified bitumen roof
under|aymentwith a36-inchsheet width.
� 4.12 PrimeSource Grip-Rite Eave&Valley Protector is a 5elf�aclhering,glass-mat reinforced,sand-surfaced,SBS
�
modified bitumen roof undpdaymant,with o36-inohsheet width.
4.13 RESISTO LB1244 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
undedaymentwith a44'inchsheet width.
4.14 Cohohene FR GR is a self-adhering, fiberglass reinforced, granule-surfaced, SBS modified bitumen roof
uoder|ayment.
4'15 UnUay (e) is mechanically attached, polyester reinforced, granule-surfaced, 8B$ modified bitumen roof
under|ayment'
5^ Lixxnxnimms:
5.1 This is o buxding code evaluation. NeitherThnityl.ERD nor Robert Niaminen, P.E. one, in any ` the
Designer of Record for any project.on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report isnot for use inthe HVHZ.
5.3 Fire Classification ianot part ofthis.report; refer tocurrent Approved goofing Materials Directory for fire
'
ratings-of this product.
` 5.4 Sopmema RoofUnderlaynnents may be�used with any prepared roof cover where the product is specifically
referenced within FBCapproval documents. |fnot listed,arequest may bemade tothe AH] for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the undedaymentuare follows:
TA&LE 1: ROOF COVER OPTIONS
Underlayment Asphalt Nall-On Foam-on Metal Wood Shakes Slate
Shingles Tile Tile Shingles
Lasto bond TU FIT Yes Yes Yes Yes Yes Yes
See 5.5.1
RESISTO SA SMOOTH PLY 40
Yes No No No Yes YesLastobond Shield HT/Pro HT-S �es No No Yes Yes Yes
Lastob.ond/Lastobond 195 Yes No No No Yes Yes
cxte,mrmeswanh-anuoesignuo Evaluation Report s1xo1o.0s.0s-110
uxWftcote,qfAvmvxzamonmmam rmssy-Rll
`
Revision 9:10/12/201S
'
Page aor7
|
| �
TABLE 1: ROOF COVER OPTIONS
Underlayment Asphalt Nail-On Foam-On Metal Wood Shakes& Slate
Shingles Tile. Tile Shingles
Lastobond ECO /RESiSTO
LB1236,Grip-Rite Eave&Valley Yes. No No No Yes Yes
Protector/RESISTO LB1244
Lastobond Smooth Sea]HT Yes No No Yes Yes Yes
Yes
Colphene FR GR Yes Yes See 5.5.1 No- Yes Yes
Unilay(e) Yes Yes Yes No No No
Batten Only I See 5.5.1
5.5.1 "Foam-On Tile" is limited to.use of the following adhesives unless tensile adhesion/long term aging data
from an accredited testing laboratory is provided.
Underlayment Adhesive(s)
Lastobond TU HT 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)or Dow Chemical TileBondT Roof
Tile Adheslve(FL717)
Colphene FR GR 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
Unilay(e) 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck:.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HTS, Lastobond TU HT, Lastobond, Lastobond 195,. Lastobond ECO, RESISTO LB1236, Grip-Rite Eave &
Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D41
primed Southern Yellow Pine;ASTM D41 primed structural concrete.
Colphene FR GR applied to:
i Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
Note:
While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends
priming with Elastocoi Stick or Elastocol 600c if the final roof cover is not slated for installation within
24 hours.
➢ Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to
installation of the self-adhering underlayment.
5.6.2 Bond-to-insulation:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave &
Valley Protector,RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to.:
> Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on tile systems(Lastobond TU HT only), insulation attachment shall be designed by a qualified
design professional and installed based on testing of the insulation/underlayment system in accordance
with FM 4474,Appendix D or TAS 114,Appendix J.
Exterior Research and Design,LLC. Evaluation Report 518016.0.6.09-R9
Cerdflcote ofAuthorkaffon#9503 FL2569-R11
Revision 9':10/12/2015
Page 4 of'7
. N L-i ARD
5.6.3 Bond to Mechanically Attached Base laver:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave &
Valley Protector,RESISTO LB124.4,Lastobond Smooth Seal HT or Colphene FR GR applied to:
> ASTM 0226,Type I or II felt;Sopra-G; Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on tile systems (Lastobond TU HT only),
base layer shall be attached in accordance with FRSA/TRI April 2012(04-12)..
.5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems;where
the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-ori tile applications.
Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has
already been applied). Refer to FBC 1609 for determination of design wind pressures.
5.6:4:1 Maximum Design Pressure=-45.0 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional) Elastocol Stick or Elastocol 6000
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
5.6.4.2. Maximum Design Pressure=-67.5 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: Elastocol 600c
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
5.6.4.3 Maximum Design Pressure=-60.0 psf.
Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin
caps(FBC 1517.5.2)spaced 6-inch o.c.at the 4-'inch laps and 6-inch o.c.in three,equally
spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered
5.6.4.4 Maximum Design Pressure=-90.0 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Underlayment: Unilay(e) mechanically attached with Soprafix Polymer Batten Bar (PBB) or Soprafix
Metal Batten Bar(MBB) with Soprema#15-EL fasteners spaced 6-inch o.c.within the 5-
inch wide, self-adhering side laps. End laps are 6-inch wide and sealed using either
heat-welding or hot-air welding techniques.
5.7 Exposure Limitations:
Lastobond, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236, Grip-Rite Eave & i
Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after installation.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond
Pro HT-S shall not be left exposed for longer than 90-days after installation.
Lastobond TU 14T or Colphene FR GR or Unilay(e)shall not be left exposed for longer than 180-days.after
installation.
Exterior Research and Design,LLC. Evaluation Report 518010.06.09-R9
Certificate afAtithorization X19303 FL2569-RII
.:Revision 9:10/12/2015.
Page 5 of 7
' ^
\
� � ����
�! � ����N Fg ~�
' 6. INSTALLATION:
6'1 5nprena Roof Undedaymentu shall be installed in accordance x6th Soprena published installation
requirements subject to.the Limitations set forth inSection Sherein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly |
to remove any dust and debris prior to application, and prime the substrate with E|astoco| Stick or
| E|astoco[6OUo(if appUcab}e).
6.3 Lastobond TU HT,Lastobond Shield,Lastobond Pro HT-N,RES11STO SA SMOOTH PLY 40,Lastobdrid Shield
HT;Lastobond Pro HT-S,Lastabond, Lastobond 195,Lastobond Eco, Ustobond Smooth Seal HT,RESISTO
L81236,Grip-Rite Eave&Valley Protector,RESISTO L81244 or Colphene FIR GR.:
63.1 Shall be installed in compliance with the requirements for ASTM D2970 undedayment in FBCSectinns
� 1SO7for the type ofprepared roof covering tobeinstalled.
6.]'Z :
While priming Is optional,Soprema recommends priming with Elastocol Stick or Elastocol 6.00c if the-final �
rwfcover bnot slated for lnsta||otionwithin.24hours.
�
Apply sheet parallel tothe roof edge. Roll out approximately 1Oftofmembrane and peel back the first 3
ftofrelease.film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the-
membrane tight.
hemembraneti8ht Firmly roll the membrane into place toachieve abond.
Horizontal seams should be minimum 3-inches, configured to shed water. vertical seams should be 6'
/ inuhes and st�g�ered nut|es»than Z4�from vertical seams in the course below. All uver`8ranu|e end-laps
~shaUbesea|edusing either heat-welding orhot air welding techniques.
When installing atslopes above 8:12'Soprema necummendg back-nailing in the overlap area-at the top of
the sheet at1Z-{noho'c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction.. For valleys,apply the sheet starting atthe lowest point and work upward.
6.3.3 Tile 4�pllcations(Lastobond TU HT or Colphene FR GR-only):
Reference is made to pRSA/TR| April 2012 k04'12 Installation Manual and Table 1-herein, using the
instructions noted above aaoguideline.
�
For foam-on tile applications, reference is-made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope ofPK5A/TR|April 2O1Z(04-12).
Tile shall be loaded and staged in a manna/ that prevents tile slippage and/or damage to the
. under|oyment.
6.4 gbnillayfe):
6.4.1
Reference is made to Table 1 herein and FRSA/TRl April 2012(04-12) installation Manual (if applicable).
'
Apply sheet parallel to the roof edge and, starting at the eave with the selvedge-edge ups|ope
mechanically attach the 5-inchwide selvedge-edge tothe wood deck with nails and tin caps urround cap-
nails spacod36-incho.c. App|ythesecond course |nawater-shedding manner with self-adhering side-
laps. Vigorous hand or motorized roller pressure is applied to the self-adhering laps to ensure a watertight
application.
Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course
below. All over-granule end-laps shall be sealed ujing either heat-welding or hot airwelding techniques.
Exterior Research and Design,LLC. cvamouonReport u1uozous.0y*R9
a,tifimatv^.)FAmm^uzamonms03 pm569-1111 |
op"mi6n9..10/12/2015 �
Page av,z
|
a ►
TNS
Tile(if applicable)shall be loaded and staged in a manner that prevents the slippage and/or damage to the
underlayment:
6.4.2 Foam-on Tile Applications:
Reference is made to FRSA/TRl April 2012 (04-12) Installation Manual, Table 1 herein and Section 5.6.4.4
herein.
Apply sheet parallel to the roof edge and, starting at the eave with the selvedge-edge upslope,
mechanically.attach the 5-inch wide selvedge-edge-to the wood deck Soprafix Polymer Batten.Bar(PBB) or
Soprafix Metal Batten Bar (MBB) with Soprema #15-EL fasteners spaced 6-inch o.c. Apply the second
course in a water-shedding manner with self-adhering side-laps. Vigorous hand or motorized roller
pressure is applied to the self-adhering laps to ensure a watertight application.
Vertical seams should be 6-inches and staggered not less than 24t from vertical seams in the course
below. All over-granule end-laps shall be sealed using either.heat-welding or hot-air welding techniques.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to .the
underlayment.
7. BUILDING PERMIT REQUIREMENTS.
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the.installation of
this.product.
g. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for information on plants covered under Rule 61620-3 QA
requirements.
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
Exterior Research and Design,I.I.C. Evaluation.Report S18010.06.09-119
Certificate of Authorization.0503 FL2569-R11
Revision 9:10/12/2015
Page 7 of 7