HomeMy WebLinkAboutBuilding Permit applicationALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: 12/02/2016 Permit Number:
Building Permit Application
Planning and Development Services
Building and Code Regulation Division
1300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential V
PERMIT APPLICATION FOR: Plumbing II
Address: 6730 TULIPAN - FORT PIERCE, FL 34951
Legal Description: SPANISH LAKES FAIRWAYS BLK 54 LOT 22 (OR 1082-2693)
Property Tax ID k: 1306-500-0275-000-5
Site Plan Name:
Project Name: Water Heater Tank Chant
Setbacks Front Back:
Out
Right Side:
Left Side:
Lot No. 22
Block No. 54
DETAILED DESCRIPTION OF WORK: III
Replace failed electric water heater tank in garage
CONSTRUCTION INFORMATION:
CONTRACTOR:
Name Dorothy J. ESPOSITO
Name: Robert W LUDLUM
'Ifwar to e e
Orme un ert
is permit—c check
a appy:
City: Port St. Lucie State: FL
Zip Code: 34984 Fax: 772-871-9069
Phone No. 772-871-9494
❑ HVAC
nGas
Tank
❑Gas Piping
❑Windows/Doors
❑Electric OPlumbing
Sprinklers
_Shutters
Generator
Roof Roofpitch
Total Sq. Ft of Construction:
SFt. of First Floor:
Cost of Construction: $ 2325.00
Utilities:]
Sewer Septic
Building Height:
OWNER/LESSEE:
CONTRACTOR:
Name Dorothy J. ESPOSITO
Name: Robert W LUDLUM
Address: 6730 Tulipan
Company: Benjamin Franklin Plumbing
City: Fort Pierce State: _
Zip Code: 34951 Fax:
Phone No. 772-460-7949
Address: 1631 SW South Macedo Blvd
City: Port St. Lucie State: FL
Zip Code: 34984 Fax: 772-871-9069
Phone No. 772-871-9494
E -Mail: nia
Fill In fee simple Title Holder on next page ( if different
from the Owner listed above)
E -Mail: Permits@benfranklinplumber.com
State or County License: CFC1426801
IT value or construction IS Bzsuu ar mare, a xeCoaneD notice of Commencement is required.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
FRONT
DESIGNER/ENGINEER:
Name:
_ Not Applicable
MORTGAGE COMPANY:
Name:
_ Not Applicable
Address:
MANGROVE
Address:
COUNTER
City:
Zip: Phone:
State:
City:
Zip: Phone:
State:
FEE SIMPLE TITLE HOLDER:
Name:
_ Not Applicable
BONDING COMPANY:
Name:
_Not Applicable
Address:
Address:
City:
City:
Zip: Phone:
Zip: Phone:
I certify that no work or Installation has commenced prior to the issuance of a permit.
St. Lucie Coon ty makes no representation that is granting a permit will authorize the ermit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or angcovenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite
before the first inspection. If youint to obtain financing, consult with lender or an attornegy before
commencine work or recordine v ice of Commencement. 'f „ n //
STATE OF FLORIDA/G�'� STATE OF FLORIDA
COUNTY OF Com" LL COUNTY OF ZSY'
The forgoing instr entym was acknowledged & by me
this da of W. 20 b
T tet=,
(Name of person acknowledging )
ignature ONotary Public -State of Florida )
Personally Known✓ qAM used
Type of Identification Produ red
commissionNo.��/6G/ __ . ery
Revised 07/15/2014
The forgoing Instrument was acknowledged before me
this `day of 20 LL by
w L&t-
(Name of persod acknowledging)
S�aNSn
(t
of Florida)
Personally Known ®,dYiP educed Id®pka1610
FC
Type of Identification Prod l 4• Nmo Pu01k - 0w/ d RAIN
Commission 0 FF IIU11
Commission No. /.`�• Mr Congg,lIkqlno AN/6, 1010
Inlsa lswye Nrlonn lWY A W.
REVIEWS
FRONT
ZONING
SUPERVISOR
PLANS
VEGETATION
SEATURTLE
MANGROVE
COUNTER
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
DATE
COMPLETE
INITIALS
Ce Smith. Residential Electric
Water Heaters
ENHANCED HEATING ELEMENTS CODE COMPLIANCE
• Dual 4500 watt elements for fast recovery • Meets UBC and ICC National Codes and
and reliable operation.' listed with CEC.
• Incoloy stainless steel lower element lasts • Complies with the Federal Energy
longer than a standard copper element. Conservation Standards effective
DYNACLEAN'" DIFFUSER DIP TUBE April 16, 2015, in accordance with the
Energy Policy and Conservation Am
• Helps reduce lime and sediment buildup (EPCA), as amended.
and maximizes hot water output. Made
from long-lasting PEX cross-linked
polymer.
HIGH ENERGY FACTORS
• Eco -friendly non -CFC foam insulation,
heat traps and other features combine
to yield a higher Energy Factor that
maximizes savings on operating costs.
COREGARd" ANODE ROD
• Our anode rods have a stainless steel
core that extends the life of the anode
rod allowing superior tank protection far
longer than standard anode rods.
BLUE DIAMOND- GLASS COATING
• Provides superior corrosion resistance
compared to industry standard glass
lining.
ENHANCED -FLOW BRASS DRAIN VALVE
• Our residential water heaters have a solid
brass, tamper resistant, enhanced -flaw,
ball type, drain valve.
• Uses a standard female hose fitting that
allows for fast and easy draining during
maintenance.
• Designed for easy operation, this valve
includes an integral screwdriver slot that
features a %turn (open/close) radius,
which not only permits full straight -
through water flow but also a quick and
positive shut off.
'Made ENL :D has a single element.
APPROVED FOR MANUFACTURED
HOUSING
• All residential electric water heaters are
compliant with HUD Standards for mobile
homes/manufactured housing.
CERTIFIED TO UL 174 FOR HOUSEHOLD
ELECTRIC WATER HEATERS
CSA CERTIFIED AND ASME RATED T&P
RELIEF VALVE
DESIGN -LISTED BY UNDERWRITERS
LABORATORIES
• Certified at 300 psi test pressure and 150
psi working pressure.
• Listed according to UL 174 standards
governing storage tank -type electric water
heaters.
6 -YEAR LIMITED TANK AND PARTS
WARRANTY
• For complete information, consult written
warranty or go to hotwateccom.
SA• UL
®March 1016 A. D. Smith Comment All all warned, page I et
werw.hotwatecmm 1800 527.1953 toll -Gree M I A. 0. Smith CoMmatim 1500 Tennessee Waltz Parkway I klilaM City TN 37015 AOSRES0602
(Ce Smith.
Residential Electric
Water Heaters
Model
Number
Gallon
Capacity
First Hour
Ratin
Gallon
Energy
Eeet0r
Recovery ®
90°F Aise
Gallon Per
Hour
Element Watta a 240V
Dimensions in Inches
ppprox.
Shit/y 9g
Wei9h[dM1z1
Standard Maximum
A B E
Tall Models
ENT 30t
1 30
1 47
0.95
21
4500
6000
46112
39-112 1
19
95
ENT 40t
1 40
1 51
0.95
21
4500
6000
SO 1/0
1 53-114 1
20
118
ENTB-SO'
S0
70
095
21
4500
6000
1 604/4
1 56114 1
21
131
ENT-SOt
1 50
1 ]I
095
21
4500
6000
601/2
51114
22
134
ENL 551
55
7
0.94
21
4500
6000
56-1 /2
48112
24
145
Short Models
Ell
30
48
0.95
21
4500
6000
39
3048
20
95
_21n
ENSdof
30
49
0,95
21
4500
1 6000
39314
30412
22
94
ENS 40t
00
1 55
095
21
4500
6000
50
40314
20112
109
ENS So
50
62
095
21
4500
6000
49-314
403/8
23
151
logrearbover TopCadded
Models
ENL40
19.5
NIA
N/A
21
4500
1 6000
1 30
21-1/4
20
65
ENLB-30•
28
1 1 40
1 0.95
1 21
1 4500
1 6000
1 30
21-314
22
96
Eiii
28
1 43
1 0.95
1
1 4500
1 6000
1 31-114
1 21-314 1
24
115
Efli
38
46
0.95
21
4500
6000
31314
1 24
24
118
ENL 40t.
38
44
095
21
4500
6000
33-112
24
26
1 11B
ENLB-5Vt
48
57
0.95
21
4500
6000
34
25
26-1/2
1 172
.dale 314- water tonne..... on dimmer
'Mels ship Add sappned'msuiati.n blanker.
tFor log ear lank and 6 her parts wananit, chance -E- to'P It me model numbe(namplz ENT 30 becomes ENT30)
. Top TSP action not ... lable cn his model.
ENT20is a single element rental This
Optional mpl&Pland tion el is uotl on In, ENIN) ENT050, ENT 55, ENS 40 and ENS 50
Optional sip T&P lwati.n 43 is Tsetl no the ENL850.
lop l&P is not available on the 10 year model ENT 50.
dimensions dad meta......... hied to change vmhow notrce In atmmd— at[ Duphl cy of continuous produ0 lintro mem.
T&P VALVE
ACCESS
PANEL
ACCESS
PANEL
DRAIN
VALVE
ANODE (OR OPTIONAL
TOP T&P LOCATION #1)
OPTIONAL TOP T&P
LOCATION #3
OPTIONAL TOPT&P
LOCATION #2
JUNCTION
T&P VALVE
®Mash 2m6 A Osmith Corporation All ti9bts reserved- Page 2 of 2