HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 4
RECEI r:D 01 0 5 �D16
� n4 ` s ' °fit' � �,) "� � •��°� � ���a3 � -zz.��e, } ��} �1�
6CIS Home Log In User Registration Hot To0cs Submit Sur harge Stats fi Facts Publications FBC Staff MS Site Map UnLs search
Businessr(, '
' � �'�� �%�,„:���Product Approval
Profess ionalUSER:Public sFILE Copy
lu..i�lirj +i
Prndmt Anawal Meml>P-d,c^or arni:c>t+:n Search>A^Vtication 1,m>Application Detail
FL# FI-1956-R12
Application Type Editorial Change
Code Version 2014
Application Status Approved
'Approved by DBPR.Approvals by DBPR shall be reviewed and
ratified by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer TAMKO Building Products,Inc.
Address/Phone/Email PO Box 1404
)oplin,MO 64802
(417)624-6644 Ext 2305
kerri_eden@tamko.com
Authorized Signature Kerri Eden
kerri—eden@tamko.com
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin,MO 64802
(417)624-6644 Ext 2305
kerri_eden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Certification Mark or Listing
Certification Agency UL LLC
Validated By Robert J.M.Nieminen,PE
�- Validation Checklist-Hardcopy Received
Referenced Standard and Year(of Standard) Standard Year'
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
Equivalence of Product Standards
Certified By -
Product Approval Method Method 1 Option A
Date Submitted 09/17/2015
http://ivvv�v.flon'dabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgs%2fmGFoyT6... 3/23/20:16
Florida Building Code Online Page 2 of 4
Date Validated 10/06/2015
Date Pending FBC,Approval
Date Approved 10/09/2015
Summa r F of Products
FL# Model,Number Description
or Name
195.6.1 Elite Glass-Seal A three tab asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in F1.1956 F.17 C CAC FL1956 R11 _
_ Tamko Senv Conf FL 1956 2015,udf
HVHZ:No F11956 r12 C CAC UL Cert;rcz0on 10-11-12 ndf
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant:N/A Installation Instructions
Design Pressure:N/A F ...956 R1 11 Glass Seal Elie G ass�?al 2oD inst ndf
Other:Asphalt shingles Verified By:Robert Nieminen 59166
shall be used only on roof Created by Independent Third Party:No
slopes of 2:12 or greater. Evaluation Reports
Nails must be used as the Created by Independent Third Party:
method of attachment.
1956.2 Glass-Seal A three tab asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in FL1956 RQ C CAC FL1956 RI 1 .0 CAC Tamko Sery Conf FL 1956 2015-odf
HVHZ:No FL1956 R12 C CAC UL certification 10.11.12 pdt
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant:N/A Installation Instructions
Design Pressure:N/A rt,L956 P12 it_Gias, Seal lite Glass Sea{ aoo irZstgf
Other:Asphalt shingles Verified By:Robert Nieminen PE 59166'
shall be used only on roof Created by Independent Third Party:No
slopes of 2:12 or greater. Evaluation Reports
Nails must be used as the Created by Independent Third Party:
method of attachment.
1956.3 1 Heritage A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in EU2113 RQ C C,A� t,�955_�?1 C C � aml:o S.�rv_lon 1f i-1g5§_�O1S p
HVHZ:No FL1956 R12 C t':AC ;,IL CgrtificatjgLi 10-11.12.odf
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant:N/A Installation Instructions
Design pressure:-N/A FL1956 R12 11 HeritagLD F J P a-po hist fid
Other:Asphalt shingles F�19s5 R22 11 Hpr[ag_S�:pP ifl5t gdf
shall be used only on roof FUH55 RI2_I �rtac���jnad:
slopes of 2:12 or greater. Verified By:Robert 1.M.Nleminen FL 59166
Nails must be used as the Created by Independent Third Party:No
method of attachment. Evaluation Reports
Created by Independent Third Party:
1956.4 Heritage 30 A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in F_L195sL R12 C CAC rL1956 R11 G CAC Tamko Sery Conf FL 1956 2015.pdf
HVHZ:No FL1956 RI?_ C CAC UL certification !0-11-12.pdf
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant:N/A Installation Instructions
Design Pressure:N/A F NC2 R12 H r a e 30 .oa inst aaril to.Udf
Other:Asphalt shingles L1956 R12 II heritage 30 ajgp Pst f—dpnl 10•pdf
shall be used only on roof Verified By:Robert Nieminen PE 59166
slopes of 2:12 or greater. Created by Independent Third Party: No
Nails must be used as the Evaluation Reports
method of attachment. Created by Independent Third Party:
1956.5 . Heritage 50 A dimensional,asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in FL3256 R12 CCAC F 1 5612 C C-C0inkg»IV Conf FL 1p56 201s".�
HVHZ:No UL certification 10_�1I-1L df
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant:N/A Installation Instructions
Design Pressure:N/A FL1956 R12 11 heritage 50 app Inst aprii 10.odf
Other:Asphalt shingles FL1955 R12 IT heritage 50 anp inst f anril 10.pdf
shall be used only on roof Verified By:Robert Nleminen PE 59166
slopes of 2:12 or greater. Created by Independent Third Party:No
Nails must be used as the Evaluation Reports
method of attachment. Created by Independent Third Party:
http://www.floridabuilding.org/pr/pi_app_dtl.aspx?param=wG EVXQwtDgs%2fmGFoyT6... 3/23/2016
Florida Building Code Online Page 3 of 4
1956.6 1 Heritage Premium A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in FL1956 R12 C CAC FL1956 RI .0 CAC Tamko Sery Conf FL 1956 2015.pdf
HVHZ:No FL1956 R12 C CRC UL certification 1G-11 12.pdf
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant:N/A Installation Instructions
Design Pressure:N/A F 119956 R12 1I Heritage Premium D i? app,inst.pdf
Other:Asphalt shingles FL1956 R12 11 Ner taoe Premium F anr� inst.odf
shall be used only on roof jEL1956 R12 11 Heritage Premium T aan inst.pdf
slopes of.2:12 or greater, Verified By:Robert Nleminen 59166
Nails must be used as the Created by Independent Third Party:No
method of attachment. Evaluation Reports
Created by Independent Third Party:
1956.7 1 Heritage Vintage A heavy weight dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in FL195b R3 C C4C FL1956 RI! C CAC Tamko Sere C.onj FL 1956 201.5,�P
HVHZ:No FL1956 R12 C CAC UL shingle matri:x.pdf
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant:N/A Installation Instructions
Design Pressure:N/A FL1956 R12.II Heritage Vintage zoo inst.odf
Other:Asphalt shingles Verified By:Robert J.M.Nieminen PE 59166
shall be used only on roof Created by Independent Third Party:No
slopes or 2:12 or greater. Evaluation Reports
Nails must be used as the Created by Independent Third Party:
method of attachment.
1956.8 Heritage Vintage Hip and ridge shingles
12 X 12 Hip.and
Ridge
Limits of Use Certification Agency Certificate
Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sero Cnf FL!q56 2015.,p�cf
HVHZ:No FL1956 R12 C CAC UL sningleatrlX.Pdf
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant:N/A Installation Instructions
Design Pressure:N/A FL1956 P.iZ 11 TArIKQCA-> Hentage0-12 x 12 Hip and Ridge Appllcatioij nStructigns.2jd
Other:Asphalt shingles Verified By:Robert J.M.Nieminen PE 59166
shall be used only on roof Created by Independent Third Party:No
slopes of 2:12 or greater. Evaluation Reports
Nails must be used as the Created by Independent Third Party:
method of attachment.
1956.9 Heritage A dimensional asphalt shingle.
Woodgate
Limits of Use Certification Agency.Certificate
Approved for use in 1 t 195 R12 C rAC F11956 Pill CAG Tamko Sere Conf FL 1956 2015.Of
HVHZ:No FL1956-9,j2 C CAC_IQC ce fi attLg0-11-iZ• df
Approved for use outside Quality Assurance Contract Expiration Date.
HVHZ:Yes 09/17/2018
Impact.Resistant:N/A Installation Instructions.
Design Pressure:N/A F1-1956 R12 It Heritane Woodoate 0app inst.pdf
Other:Asphalt shingles FL1.456 R12 Ii Heritage Woodgate F apo inst.odf
.shall be used only on roof Verified By:RobertNieminen 59166
slopes of 2:12 or greater. Created by Independent Third Party:No
Nails must be used as the Evaluation Reports
method of attachment. Created by Independent Third Party:
1956.10 Heritage XL A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in 171-1956 R12 G y�El 1256 RJ�1 C CAC Tamko Sen,Ca FL 1956 201 S,p--f
HVHZ:No FL1956 R12 C CAC UL certification 10-11-12.rdf
Approved for use outside Quality Assurance Contract Expiration pate
HVHZ:Yes 09/17/2018
Impact Resistant:N/A Installation Instructions
Design Pressure:N/A FL1956 R12 If heriiiage xi aqp inst d agrii 10.pdf
Other:Asphalt shingles ' 11-1956 R12 II heritage xi app inst f.aoril Modf
shall be used only on roof Verified By:Robert Nleminen PE 59166
slopes of 2:12 or greater. Created by Independent Third Party:No
Nails must be used as the Evaluation Reports
method of attachment. Created by Independent Third Party:
1955.11 Hip and Ridge Hip and ridge shingles
Shingles
Limits of Use Certification Agency Certificate
Approved for use in FU955 U2 C CAC Fl-1956 iii i C CAC Tamko Sery Cynf.FL 1956 2015 pdf
HVHZ:No FL1956 R12 C CRC UL certifiCat n 10-11-12.13df
http://wvviv.floridabuilding.org/pr/pi_app_dtl.aspx?param=wGEVXQwtDgs%2 fmGFoyT6... 3/23/2016
Florida Building,Code Online Page 4 of 4.
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant:N/A Installation Instructions
Design Pressure:N/A Rl956 n_l.Z_II 1L25..c1 Nl�anrl Ridge odt
Other:Hip and Ridge .FL?91fi R12 iI 12 x riip_Rifl.�_Aopl cahonnstn ctions.adt
shingles shall be used only. FLiGSG R12 II 12-1 9Y 7 HloRidge Sealant'Qab lilustraon Pei
on roof slopes of 2:12 or FU. _56 R12 II 17.x;i2 HlnRldoe 5agaDrit Dab iilus[rarions.2df
greater.Nails must be used Verified 6y:Robert Nieminen 59166
as the method of Created by Independent Third Party: No
attachment: Evaluation Reports
Created by Independent Third Party:,
finch t:e+R "
Contact Us::1940 North Monroe Street Tallahassee FL 32399 Rhona•850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Flonda ::Privacy Statement::A_ccessib+lity Statement::Refund Statement
Under Florida law,email addresses are public records,If you do not want your a-mail address relmn in response to a public-records request,do not send
electronic mail to this emity.Instead,concert the office by phone or by traditional mail.If'you have any que,tions,please contact 850.487.1395.'Pursuant to
Section 455.275(1),Florida Statutes,effective Dauber 1,2012,liconsees licensed under Chapter 455,F.S.must provide:the Department with an email address if
they have one,The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do rot wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click he e_. -
Product Approval Accepts:
�rt'llrll Piss i;iCt
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgs%2fmGFoyT6... 3/23/2016
Application Instructions E®r
ETA:IMK HERITAGr 30
BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES
Dallas, TX ® Tuscaloosa, AL • Phillipsburg, KS • Joplin, MO
THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED.
TAMKO BUILDING PRODUCTS,INC.ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING
FROM FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS.
THIS PRODUCT IS COVERED BY A LIMITED WARRANTY,THE TERMS OF WHICH ARE PRINTED ON THE WRAPPER.
IN COLD WEATHER(BELOW 4WF),CARE MUST BE TAKEN TO AVOID DAMAGE TO THE EDGES AND CORNERS OF THE SHINGLES.
IMPORTANT:It is not necessary to remove the plastic strip from the back of the shingles.
1.Boor BECK &FASTENERS
These shingles are for application to roof decks capable of receiving WIND PAY—TIO—N., Extreme wind velocities can damage these
and retaining fasteners,and to inclines of not less than 2 in.per foot shingles after application when proper seating of the shingles
For roofs having pitches 2 in.per foot to less than 4 In.per foot,refer does not occur.This can especially be a problem if the shingles
to special instructions titled"Low Slope Application".Shingles must are applied in cooler months or in areas on the roof that do not
be applied properly.TAMKO assumes no responsibility for leaks or receive direct sunlight. These conditions may impede the sealing
defects resulting from improper application, or failure to properly of the adhesive strips on the shingles.The inability to seal down
prepare the surface to be roofed over. may be compounded by prolonged cold weather conditions and/
NEW ROOF DECK CONSTRUCTION.,Roof deck must be smooth, or blowing dust.In these situations,hand sealing of the shingles is
dry and free from warped surfaces.It is recommended that metal recommended.To insure immediate sealing,apply 4 quarter-sized
drip edges be installed at eaves and rakes. dabs of TAM-PROF Premium SBS Adhesive or TAMKO Tam-Seal
Adhesive on the back of the shingle 1 in.(25mm)and 13 in.(330mm)
PLYWOOD:All plywood shall be exterior grade as defined by the in from each side and 1 in. (25mm) up from the bottom of the
Engineered Wood Association.Plywood shall be a minimum of 3/8 shingle.Press shingle firmly Into the adhesive.For maximum wind
in.thickness and applied in accordance with the recommendations resistance along rakes, cement shingles to the underlayment and
of the Engineered Wood Association. each other in a 4 in.(102mm)width of TAM-PRO 888 Adhesive or
SHEATHING BOARDS: Boards shall be well-seasoned tongue- TAMKO Tam-Seal Adhesive. Caution:Apply ONLY a thin uniform
and-groove boards and not over 6 in.nominal width.Boards shall layer of adhesive less than 1/8 in.(3mm)thick.Excessive amounts
be a 1 in. nominal minimum thickness. Boards shall be properly can cause blistering of the shingles and may soften the asphalt in
spaced and nailed. certain underlayments resulting in the asphalt flowing,dripping and
staining.Shingles must also be fastened according to the fastening
2.VENTMATI®N instructions described below.
Inadequate ventilation of attic spaces can cause accumulation of Correct placement of the fasteners is critical to the performance
moisture in winter months and a build up of heat in the summer. of the shingle. If the fasteners are not placed as shown in the
These conditions can lead to: diagram and described below,this will result in the termination of
TAMKO's liabilities under the limited warranty.TAMKO will not be
1.Vapor Condensation responsible for damage to shingles caused by winds in excess of
2.Buckling of shingles due to deck movement. the applicable mph as stated in the limited warranty.See limited
warranty for details.
3.Rotting of wood members.
FASTENING PATTERN S:Fasteners must be placed 6-1/8 in.from
4.Premature failure of roof, the bottom edge of the shingle, penetrating through the common
To insure adequate ventilation and circulation of air,place louvers bond,and located horizontally as follows:
of sufficient size high in the gable ends and/or Install continuous 1)Standard Fastening Pattern.(For use on decks with slopes 2 in.
ridge and soffit vents. FHA minimum property standards require per foot to 21 in.per foot.)One fastener 1 in.back from each end
one square foot of net free ventilation area to each 150 square feet and one 13-1/2 in.back from each end of the shingle for a total of 4
of space to be vented,or one square foot per 300 square feet if a fasteners.(See standard fastening pattern illustrated below).
vapor barrier is installed on the warm side of the ceiling or if at least
one half of the ventilation is provided near the ridge.If the ventilation STANDARD FASTENING PATTERN
openings are screened,the total area should be doubled. FASTENERS NAIL ZONE
COMMON
BOND
IT IS PARTICULARLY IMPORTANT TO PROVIDE
ADEQUATE VENTILATION. FJCPOSURE&SM"
1`-'-q{ �— 12-1/2"—�+—12-3/8"—►f�— 12-t/2"-� �-1"
(Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11/09
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2556
tafT1kO.Com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 `�
(CONTINUED from page 1)
TANKO HERITAGEO 30
BUILDING PRODUCTS LAMINATED ASPHA6T SHINGLES
Dallas,TX a Tuscaloosa, AL e Phillipsburg, KS • Joplin, MO
2) Mansard Fastening Pattern. (For use on decks with slopes 'be a minimurn of 1-1/4 in.for new construction and 1-1/2 in. for
greater than 2t in.per foot.)One fastener 1 in.back from each end reroofing.thus:allowing a minimum deck penetration of 3/4 in.The
and one fastener 8-1/2 in.back from each end and one fastener 16 crown'of the staple must be parallel to the length of the shingle.
in.back from each end for a total of 6 fasteners per shingle.(See The staple crown should be driven flush with the shingle surface.
Mansard and High Wind Fastening Pattern illustrated below.) Staples that are crooked,underdriven or overdriven are considered
MANSARD AND HIGH WIND FASTENING PATTERN improperly applied.
FASTENERS NAIL ZONE Property Driven Improperly Driven
COMMON ,�1�, urriertrttve:l overdriven crwxed
BOND -917=1
_AWiall
1r8
S IiNles
6. "
Fx_P<1
SURE 5-SM,, �•� �--Ozcking
:� Ir - ENRAM
-
�r-+1.},-�-�rz"*i+-r-�rz••+F►-�-�a•-.{t�-1rz"�►kf-r-trz� �1.. t ,m
3) High Wind Fastening Pattern. (For High Wind Application CAU-I QN:ALL FASTENERS MUST BE DRIVEN INTO THE NAIL
requirements)One fastener 1 In.back from each end.One fastener ZONE/COMMON BOND AS SHOWN IN'THE DIAGRAM ABOVE.
B-1/2 in.back from each end and one fastener 16 in.back from each �.Q1hYdlA6A1�IYl�),17,
end for a total of six(6)fasteners per shingle.in addition to this shingle
fastening pattern requirement for High Wind Application,TAMKO UNDERLAYMENT:An underlayment consisting of asphalt saturated
also requires the use of the following TAMKO products: TAMKO felt must be applied over the entire deck before the installation of
felts or underlayments;TAMKO Moisture Guard Plus underlayment TAMKO shingles.Faflure to add underlayment can cause premature
at all eaves,rakes,and valleys;TAMKO or TAM-PRO cements and failure of the shingles which is not covered by TAMKO's limited
coatings products where required:TAMKO ventilation where required, warranty.;Apply the felt when the deck is dry.On roof decks 4 in.
TAMKO starter.shingles if available in area.and TAMKO Hip and Ridge per foot and greater apply the felt parallel to the eaves lapping each
shingles installed on all hips and ridges.Along rakes,cement shingles course of the felt over the lower course at least 2 in.Where ends
to the underlayment and each other in a 4 in.(102;mm)width of TAM-' --join, lap the-felt 4 in. If left exposed, the underlayment felt may
PRO SBS Adhesive or TAMKO Tam-Seal Adhesive..Also,see local be adversely-affected.by moisture and weathering_ Laying of the
building codes for proper nailing application.High.Wind Application underlayment and the shingle application must be done together
is offered on new construction or complete tear-off applications only, . Products which are acceptable for use as underlayment are:
It is not offered for recover applications. If High Wind Application
requirements are not followed,the High Wind Application Warranty - TAMKO No.15 Asphalt Saturated Organic Felt
MPH, as stated on Table I in the Limited Warranty, reverts to the - A non-perforated asphalt saturated organic felt which meets
Standard Application Wind Warranty MPH limit.(See Mansard and ASTM:D226,Type I or ASTM D4869,Type I
High Wind Fastening Pattern illustrated above.) - Any TAMKO non-perforated asphalt saturated organic felt
NAILS:TAMKO recommends the use of nails as the preferred method - TAMKO TW Metal and Tile Underlayment,TW Underlayment
N a Ifcatipn. Standard and Moisture Guard Plus (additional ventilation may be
pp type roofing nails should be used. Nail required.Contact TAMKO's Technical Services Department
shanks should be.made of minimum 12 gauge wire,and a minimum for more information,)
head diameter of 3/8 in. Nails should be long enough to penetrate
3/4 in.into.the roof deck.Where the deck is less than 3/4 in.thick, In areas where ice builds up along the eaves or a back-up of water
the nails should be long enough to penetrate completelythrough from frozen or clogged gutters is a potential problem. TAMKO's
plywood decking and extend at least 1/8 in.through the roof deck. Moisture Guard Plus'waterproofing underlayment(or any specialty
Drive nail head'fiush with the shingle surface. eaves flashing.product) may be applied to eaves, rakes, ridges,
valleys, around chimneys, skylights or dormers to help prevent
p�oemum�n Implepenr°`Ivan .water damage. Contact TAMKO's Technical Services Department
t l) 3V Mhf dlmnehn undo dri m overdriven crooked
i — for more information.
4
------t�I"'--- - - �_AsphaG
_ shhslo TAMKO does not recommend the use of any substitute products
rw�_k" as shingle underlayment.
MW.r'hf.9.W pni�elrahan. WMdMivam lee deep.cute lradeduolc S.iAPPWLdlTiON INSTRUCTIONS
MW rnmh nim wnyro cornu peneimllell W.W.010 on<n«e� $TA_811ER_QOURSE_A siarter course may consist of TAMKO Shingle
Starter,self-sealing 3-tab shingles or a 9 inch wide strip of mineral
STAPLES:If staples are used in the attaching process,follow the surface•roll roofing.If self-sealing 3-tab shingles are used,remove
above instructions for placement.All staples must be driven with' the exposed tab portion and install with the factory applied adhesive
pneumatic Staplers.The staple must meet the following minimum adjacent to the eaves.Attach the starter course with approved
dimensional requirements.Staples must be made from a minimum fasteners along a line parallel to and 3 in.to 4 in.above the eaves
16 gauge galvanized wire.Crown width must. be at least 15/16 in. edge.The starter course should overhang both the eaves and rake
(staple crown width is measured outside the legs).Leg length should edges 1/4 in.to 3/8 in.
_ (Continuer!)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11109
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick.MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-22872656
taf11koxom Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 60216 800-53D-8868 2
9 (CONTINUED from page 2)
ffTA:M, K 0 H9RITA Gr 30
EuIi�D[NG P��®®carMR s 1.AlH1NATED ASPRA16T SHINGLES
Dallas, TX •Tuscaloosa, AL e Phillipsburg, KS *Joplin, MO
SHINGLEAPPLiCATiON:Start the first course with a full size shingle 6.LOIN S14OPE APPLDGAT>ION
and overhang the rake edge 1/4 in.Cut 10-3/8 in.from a full shingle On pitches 2 in.per foot to-4 in.per foot cover the deck with two layers
to form ashingle 29 in.long.Use this to start the second course(see of asphalt saturated fait.Begin by applying the felt in a 19 in,wide strip
diagram below).Cut a 23 in.long ofsingle to start the third course.Use along the eaves and overhanging the drip edge by 1/4 to 3/4 in,Place
the remaining 16-3/8 in.piece of shingle to start the fourth course and a full 36 In,wide sheet over the 19 in.wide starter piece,completely
use the remaining 10-3i8 In.piece to begin the fifth course.Continue overlapping it.All succeeding courses will be positioned to overiap the
up the rake.in as many rows as necessary using the same formula preceding course by 19 in.If winter temperatures average 25'F or less,
as outlined above.The butt of the shingle.should be aligned with thoroughly,cement the felts to each other with TAM-PRO'or TAMKO
the top edge of the sawtooth of the underlying shingle for a 5-5/8 in. Plastic Roof Cement from eaves and rakes to a point of.a least 24 in.
exposure(tee shingle application drawing illustrated on this panel). inside the interior wall line of the building.As an alternative,TAMKO's
When you make your final cut at the roof's edge,'flip any pieces that Moisture Guard Plusb self-adhering waterproofing underlayment may
are 8 in,or longer back onto the roof.These pieces can be workedbe used in lieu of the cemented felts.
in anywhere without creating zippers or color variations.
NOTE~ Do not align joints of shingle courses when working in out 7'MANSARD ROOF OR STEEP S6DFE DDDF
pieces.Joints should be no closer than 4 in.from one another. if the slope exceeds 21 in.perfoot(60',each shingte must be sealed with
TAM-PRO SBS Adhesive or TAMKO Tam-Seal Adhesive immediately
upon installation.Spots of cement must be equivalent in size to a$.25
piece and applied to shingles with a 5-5/8 in.exposure,use 6 fasteners
10.3!8^ per shingle.See Section 3 for the Mansard Fastening Pattern.
'= G.MROOFING
repeat
courses 18-318"° to-3t8n " Before re-roofing,be certain to inspect the roof decks.All plywood
„ shall meet the,requirementslisted in Section 1.
23
!3” Nail down or remove curled or broken shingles from the existing
i rt �s 3ra" 23` roof.Replace all missing shingieswith new ones to provide a smooth
Milt 0 Put base. Shingles that are buckled usually indicate warped decking
10.318• or protruding nails. Hammer down all protruding nails or remove
them and refasten in a new location. Remove all drip edge metal
51h course
23.1 18-318- and replace with new.
41h caursc 18-3/8"
If re-roofing over an existing roof where new flashing is required
3rd comm as to protectagainst ice dams"(freeze/thaw cycle of water and/or the
2nd course 29" 29" backup of water in frozen or clogged gutters),remove the old roofing
to a point at least 24 in. beyond the interior wall line and apply
1st course f[til 10.818° TAMKO's_Moisture Guard Plus'waterproofing underlayment-Contact
TAMKO's Technical,Services Department for more information.
Measurements will vary when nesting over an existing 5 in.exposure
single roof:Call TAMKO Technical Services for further information.
Cul}tial lou'✓.u5d s5i"py to mu�p?3'u,>]4 10.}:11" '
'•Fau;a �,^° , tana.a 4=8'111 The nesting procedure described below is the preferred method for
reroof Ing over existing metric size shingles with a 5-5/8 in.exposure.
See description below:
Sfarterputse:Remove the tabs and an additional portion from the
head of a full size shingle so that its height is equal to the exposure
z of the existing shingles.Position the resulting strip over the existing
roof edge(with the factory-applied adhesive strip along the eaves).
Cut approximately 6 in.from the rake end and•apply the reinaining
portion at the eaves.Continue the starter strip by applying full length
shingle strips cut to height as above,evenly along the existing roof
at the eaves.The existing roof should overhang the eaves fiat
s*ry0,o,, enough to carry water off Into the gutter.If this is not the case,
cut and apply the starter strip so that it will provide sufficient
overhang for proper drainage.
fa..`ec,o Ovral,Jryu,x:,yn:m.;Sho,oJt,NAgn yK+O 37K�;,.¢0t" n First Cour,��c.�P,�.�..M;,v.n,.:�r,�-uN;�.s•,r &e_:Remove an amount from the butt edge of a futi-size
�.n^°».,d•"n. nr ^',"�'^°:,� �,°^°t,.,.: shingle so that the remaining portion of the shingle fits between the
HOTf:Oc r,W didnjch+ta atnhift*co,vtcawAen Ming In butts of the existing third course.This course must also be applied
"I ptccas.Jdit t 31f W d bo,M 06° tkdn 4-tmmn on,m0lnv.
evenly along the eaves edge of the new starter strip.
(Continued)
Central District 220 West 4th St., Joplin;MO 64801 800-641-4691 11109
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick.MD 21701 800-368-2055
Southeast District. 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
#arrlko.com Southwest District 7910 S.Centrai Exp., Dallas,TX 75216 800-443-1834
Westem bistrict 5300 East 43rd Ave., Denver,CO 60216 800-530-8868 3
(CONTINUED from page 3)
TAMK HEUITAGI r 30
811ILDING PROD®CTS AMIMINAtTED ASPHALT SHI>NGIaES
Dallas,TX Tuscaloosa,AL • Phillipsburg, KS •Joplin, MO
Second and Succeeding_Course% Remove 10-3/8 in. from-the FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE
rake end of the Arst shingle in'the second course, and continue CONTACTTAMKO'S TECHNICAL SERVICES DEPARTMENT.
with full width shingles for the remainder of the course, placing
thetop edge of each new shingle against the,b6tt edge of the old t.wfty emmun,
shin le in the course above This method should create an exposure �,u 2s mim}we,
g p of Nail Fast,Mohhtm
of 5-5/8 in,after the first course.When beginning-the succeeding Guard Flu or so lo: air. as q,
or heaver r,- moryxr\ mxi 6rsJ*V,)
courses eontinue'to follow the Heritage application instructions. Utmdend"to.12'-18'hrya
(See section 5). ,�,�.r�,;,,rn„V
tNisting shingles s .i
,} -UrdelaYmvnt •� D:c!as;en<rs within.
\r t'•�� 13.1l4 .�~, .��' �Y 11 ;4 r "�:•
z
Drip edge.`
X C \ . .t. �1 r Dri ed a u,e`e ip a w ro z in<t� g'sk
, .P $ firsm Yaaey centedb and trneruig.
New shingles 4��f s' r ' ihe+iwtical ddn^,�.
exposure IO.HIP ARID RIDGE FASTENING OLVA16
expmure
I Apply the,shingles with a.5 in,exposure beginning at the bottom
I of the hip or from the end of the ridge opposite the direction.of the
9.VALLEY APPLICATION prevailing winds.Secure each shingle with one fastener on each side,
5-1/2 in.back from the exposed end and 1 in.up from the edge.
Over the shingle underlaymenf,center aminimum 36 in.wide sheet TAMKO recommends the use.of TAMKO Nip& Ridge shingle.
ofTAMKb Nail-Fast ,Moisture Guard Plus'or a minimum 50 lb.roll products.com matching colors are available,if is acceptable l
o.
place and then only nail'the outside edges. e
roofing in the valley,Nail the felt only where necessary to hold it in use TAMKO's Elite Glass-Seal shingles cut down to 12 in.pleces.,
IMPORTANT PRIOR TO INSTALLATION WARM'SHINGLES TO Fasteners should be_114 in.longer than the one used for shingles
PREVENT.DAMAGE WHICH CAN OCCUR WHILE BENDING IMPORTANT: PRIOR TO INSTALLATION, CARE NEEDS TO BE
SHINGLES TO FORM VALLEY, TAKEN TO PREVENT DAMAGE WHICH CAN OCCUR WHILE
After valley flashing is in place:.
BENDING SHINGLE IN COLD WEATHER.
• Apply the first,course.of shingles along the eaves of one of the Dlrectio of,preval ing wind
intersecting roof planes and across the valley. Start &^'exposure
Note:For Proper Ilow ofwater over the trimmed shingle,always here,-
t"
start applying the shingles on the roof plane that has the lower
slope or less height.' ,;'� � ��5-t!z°Fastener
• Extend the end shingle at:feast 12 in.onto the adjoining roof. 1 I Start
Apply succeeding courses in the same manner,extending them here 5°exposure
across the valley and onto the adjoining roof.
• Press the shingles tightly into the valley. THESE ARE THE MAN'UFACTURER'$ APPLICATION .
• Usenormafshingle fastening methods. INSTRUCTIONS FOR THE ROOFING CONDITIONS
_DESCRIBED.TAMKO'BUILDING PRODUCTS;:INC.ASSUMES
Note:No fastener should be within6in,ofthie.valleycenterline, NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
and two fasteners should be placed at the end of each shingle DEFECTS_RESULTING FROM FAILURE TO FOLLOW THE
crossing the valley. MANUFACTURER'S INSTRUCTIONS.
• To the adjoining roof plan6,apply one row of shingles vertically
facing-the valley and 2 in.back from the valley centerline.
TAMKOO,Mwstura tabard PIUsb,wail FsstO,TAM-PROS and tleritagetri are registered,
Note:For a neater installation, snap a chalkline over the trademarks of TAMKO Building Products,Inc.
shingles for guidance.
information inoluded In these appllcadon instructions vias current ai time of printing,To
• To complete the valley,apply'shingles on'the adjoining roof obtain a copy of the most current version of these app&catinn instructions,Visit us online
plane',by positioning the fip-of the first shingle of each row at at tarnko.c6m or can tis at 800.641-4691.
the 2 in.point from the centerline where the edge of the vertical
shingle has been applied;,covering the vertical shingle.
Central District 220 West 4th St., Joplin,MO64801 800-6414691 Mos
Visit Our Web Site at Northeast District _ 4500•Tarrlko Dr., Frederick,'MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
trarflko.COITt Southwest.District 7910 S.Central Exp:; Dallas,TX 75216 800-443-1834
Western District . 5300 East 43rd Ave.,' Denver GO.80216 800-530-8868
�.......,. .F_, F- .. 4 .-o.a':,..,.,7,. ..F,P, .. ...-.�:w..,. ..,..,....*C ...,.� ,. ..t -._ .^. __.n.:,S.:............_..3.-...-..-..........+,i,,n .. ._v..__............ .....