HomeMy WebLinkAboutEngineeringPAUL WELCH INC.
Mechanical * Electrical * Civil Engineering
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
Email pwelchinc@aol.com
December 5, 2016
Re: Door Replacement
7350 S US Hwy 1
Port St. Lucie, FL
To Whom It May Concern:
Our office has calculated the required design pressure in accordance with ASCE 7-10 for
a replacement of the doors at the above referenced address.
Wind speed: V,it: 160mph, Via: 124 mph
Exposure: C
Enclosure Type: Enclosed
Door Size: 12' wide X 14' high Roll Up Door
Quantity of Doors: 1
Location: Zone 5 (Per Attached Sketch)
Required Design Pressure (Zone 5): +21.8/ -28.1 PSF Worst Case
Door to be installed shall. be equal to, or exceed the required design pressures as listed
above. All installations shall be in accordance with FBC 2014 and manufacturer's
installation instructions.
Proposed Door: ASTA DOOR CORPORATION
FL#14432.8 (+/- 32.2 PSF).
Thank you for your attention to this matter.
Submitted by:
PAUL WELCH INC.
Paul Welch, P.E.
Reg. No 29945 -
Attached: product Approval Affid.
Area of Work Plan -
Building Permit # _
Planning & Development Services Department
Building & Regulations Division
Product Review Affidavit
Owners Name Applicant:
1" 12. I= A i e i ,e- ! t._1 -t' 'r
Product
Opening Design
Pressures
Product Rated
Pressure,
Manufacturer
Model Number
t
Product Approval
Number
'Glass
Type
Method of Attachment
Windows
—.-Dsigalan
Mullions
Fixed Glass
Block Glass
skylights
Sliding Glass Doors
-Swing Type Doors
French Doors
Gangspoors
Hunicane Protection
�' Z1.3/�2&,i
�/- 32.2
S�L�
2
`
El.� !4432 �
N .p
�/a"'` _�� JC � '�4" 'SEtF Vt�u�.trjL Strtt
L a � Z
Roof ventilation
Roofing Material
I have reviewed the above components* cladding and I have approved their use !q`his'\ te�ctuxe:These products provide adequate resistance to the
wind loads and forces speckled by current code provisions.
Name: PAUL WELCH P.E. Signature: -
Design Profs J PAUL WELCH FX Cert. No. .29945 Date:
11
'111111}11V�0
Door Replacement
7350 S US Hwy 1
Port St. Lucie, FL
A
PAUL WELCH INC.
Mechanical * Electrical * Civil Engineering
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
Email pwelchinc@aol.com
A"/
as
12
W
12' X 14' Roll Up Door
AREA OF WORK PLAN nts...
Paul Welch, P.E.
Reg. No 29945
December 5, 2016
NORTH