Loading...
HomeMy WebLinkAboutProduct Approval FILE COP : RECEI%'rD DEC 0 "6 MIAMI-DADS COUNTY MIAMI•DADE; PRODUCT CONTROL SECTION 11805 SW 26 Street- lWonl 208 DEPARTMENT Or REGULATORY AND ECONOMIC RESOURCES(RER) Miami.Florida 33175-2174 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTiCE OF ACCEPTANCE (NOA) DV�9 DD.mialnidadL'. (DY L'l'l)Il 11111�' GAF 1 Campus Dt•ive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. 'i-hc documentation submitted has been reviewed and accepted by Mianli-Dade County RLR -Product Control Section to he used in Miami Dade County and other areas where allowed by the Authority Flaving.lurisdiction (AFIJ). This NOA shall not be valid after the expiration date stated below. The Mianli-Dade County Product Control Section (in Miami Dade County) and/or the AM (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. if this product or material fails to perFornl in the accepted manner, the manufacturer will incur the expense 01• such testing and the AM play immediately revoke, modify, or suspend the use of such product or material within their.jurisdiction. RER reserves the right to revolve this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane "Lone of the Florida Building Code. DESCRIPTION: GA TiutL�et line iu,i, c;-1'i�ubc�line Natun•al Shadow",and Timberline American Hal-vesf` S11111gles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and fallowing statement: "Mianli-Dade County Product Control Approved", Unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and d1Cre has beell no cliallgc in the applicable building code negatively affecting tale performance of this product. TERMINATION of this NOA will occur alter the expiration date or if there has been a revision or change in the materials, use, and/or mailulacture of the product Or process. Misuse Of this NOA as all endorsement of any product., for sales, advertising Orally other purposes shall automatically terminate this NOA. Failure to calllply with any section of this NOA shall be cause for termination and removal ofNOA. ADVERTISEMENT: The NOA number preceded by the words Mianli-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. if any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the_job site at the request of the Building Official. This NOA revises NOA 13-0419.04 and consists of pages I through 6. The submitted documentation was reviewed by Juan E. Collao, R.A. 1 � NOA No.: 14-1022.20 MIAMI•DADECOUNTY 1 Expiration Date: 02/21/17 Approval Date: 02/05/15 Page I of 6 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Asphalt Shingles Materials: J,aniinatc Deck Type: Wood- SCOn This approves GAF Timberline 1-TD`%Timberline Natural Shadom,'�`, and Timberline American Harvest** Shingles as manufactured by GAF as described in Section 2 of this Notice of Acceptance, PRODUCT M SCRIPTION PI-Oduct Dimensions Test Pi-oduct Description Socciriciltions GAF Tilubel.Jille Fl R 13 '/j x 39'/; 'iberglass reinforced heavy weight asphalt TAS I 10 1- roof shingle,with a laminate profile Loculions#11,2,3,4,5,6,7 GAF Timberline Natural 13 Il,I x 39 TAS 110 Fiberglass reinforced heavy weight asphalt Shadow'°" roof shingle, with a laminate profile Mcillyfilcawring Loccilions#l,2,3,4,5,6,7 GAF ThubcHine AnicHum 13 x 39'/8" TAS 110 Fiberglass reinforced heavy weight asphalt Hai-vesfull roof shingle,with a laminate profile Alleinqfficlui-ing Lowlions#2,4,5,6 MANUFACTURING LOCATION 1. Tampa, FI' 2. Michigan City, IN 3. Baltimore, MD 4. Myerstown, PA 5. Unnis,TX 6. Tuscaloosa,AL 7. Dallas, TX I&MIAMi-DAbE COUNTY Expiration No.: 14-1022.20 Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 2 of 6 EVIDENCE SUBMITTED Test Agency Test identifier 'fest Name/Report Date Underwriters Laboratories, Ina ASTM D3462 11CA48924 10/24/11 Underwriters Laboratories, Inc ASTM D3462 IOCA21994 04/22/11 Underwriters Laboratories, Inc ASTM D3462 l OCA28717 07/26/11 Underwriters Laboratories, Inc. ASTM D3462 05CA47541 11/10/06 Underwriters Laboratories, Inc. ASTM D3462 06CA31580 11/30/06 PRI Asphalt Technologies, lne. ASTM D3462 GAF-101-02-02 11/02/05 Underwriters Laboratories, [tic. ASTM D3462 06NK05159 08/09/06 I1111 Asphalt Technologies, Inc. ASTM D3462 GAF-098-02-02 11/08/05 Underwriters Laboratories, Inc. ASTM D3462 02NK41809 09/11/02 Underwriters Laboratories, Inc. ASTM D3462 03NK264441 10/17/03 Center for Applied Engineering ASTM D3462 257989 05/13/97 Undcrwriters Laboratories, Inc. TAS 107 OINK45803 04/13/94 Underwriters Laboratories, Inc. TAS 107 06NKO5159 08/09/06 Underwriters Laboratories, Inc. TAS 107 04NK04273 02/20/04 Underwriters Laboratories, Inc. TAS 107 05CA42840 11/11/05 Underwriters Laboratories, Inc. TAS 107 02NK4181 1 1 1/1 1/02 Underwriters Laboratories, Inc. TAS 107 03CA35209 10/17/03 Underwriters Laboratories, Inc. TAS 107 04CA13850 08/30/04 Center for Applied Engineering TAS 100 257989 04/01!97 PRI Asphalt Technologies, Inc. TAS 100 GAF-044-02-01 01/13/04 PRI Asplialt Technologies, Inc. TAS 100 GAF-098-02-01 11/08/05 PRI Asplialt Technologies, Inc. TAS 100 GAF-101-02-01 11/09/05 PRI Asphalt Teclino logics, hlc. TAS 100 GAF-1 16-02-02 03/23/06 PRI Asphalt Technologies, Itic. TAS-100 ELK-083-02-01 10/16/02 ELK-084-02-01 10/15/02 ELK-085-02-01 10/14/02 ELK-086-02-01 10/24/02 ELK-087-02-01 10/21/02 ELK-088-02-01 10/16/02 ELK-107-02-01 10/09/03 ELK-108-02-01 10/09/03 ELK-109-02-01 10/09/03 .IMITATIONS I. Fire classification is not part of this acceptance; refer to a current Approved Rooting Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit In accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. MIAMI•DADE CQUfdTY NOA No.: 14-1022.20 Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 3 of 6 INSTALLATION 1. Shingles shall be installed in compliance with Rooting Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instruo6011s. 4. Exposure and Course layout shall be in compliance with Detail 'A', attached. 5. Nailing shall be in compliance with Detail '13%attached. LABELING Shingles shall bear the imprint or identifiable marking of' the manufacturer's name or logo, city and stale of manufacturing facility, and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade Comity Product Control Seal as shown below. MIAMI•DADE COUNTY •••• gn BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies ot'the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. N MIAMFDADE COUNTY OA No.: 14-1022.20 Expiration Date: 02/21/17 Approval Date: 02/05115 Page 4 of 6 DETAIL A COURSE LAYOUT DECK FULL 5th 17" OFF 4th 11 OFF 3rd 6"OFF 2nd FULL 1 st WMIAMI-DADE COUNTYNOA No.: 14-1022.20 low Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 5 of 6 DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN - 39-3/811 (tm) �— 14-1/2"-17-112" 14-112"-17-112" 1 (368-445mmm) (368-445inm) 6-112"-9-112" 6-112"-9-112" ail guide line 13-1/4tt JIGS-24 W.) (aen.241—) 5.314"-6-1/4" (337mm) �_ ,_„ (1 46mm-159mm) z-vz° from bottom of shingle 9 elf seal adhesive on back ENHANCED NAILING PATTERN - six nails per shingle* required by some local codes and required for enhanced wind coverage on certain products. See limited warranty for details. These shingles MUST be nailed a nominal 6" (152mm)from bottom of of shingle, above the cut outs, as shown. Nails must not be exposed. END Off' THIS ACCEPTANCE NOA No.: 14-1022.20 witArwf.oAoE couNnr Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 6of6