HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2
t1
r;
SCIS Home Log In User Registrations Hot Topic Submit Surcharge Stats&Facts i Publications FBC Staff j BCIS Site Map Links j Search
AOfla2 d :r Product ApproElf C C I V-1 D LCC O 6 20116
'�
rUSER:Public User
�
r rwcn m
Product Approval Menu>Product or Application Search> [io >(0-
hD v.
im
FL# FL10674-R12
Application Type Revision
Code Version 2014
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M.Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/20/2017
Validated By John W. Knezevich,PE
Cl Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 R12 COI 2016 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
Equivalence of Product Standards
Certified By
Sections from the Code
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%... 11/21/2016
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 04/18/2016
Date Validated 04/19/2016
Date Pending FBC Approval 04/20/2016
Date Approved 06/08/2016
Summary of Products
FL# Model,Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab, laminated,starter and hip&ridge
Shingles and Starters shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10674 R12 II 2016 04 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-R12.odf
Impact Resistant:N/A Verified By: Robert J.M.Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party: Yes
Other:Refer to ER,Section 5. Evaluation Reports
FL10674 R12 AE 2016 04 FINAL ER OC ASPHALT
SHINGLES FL10674-R12.Ddf
Created by Independent Third Party: Yes
Back Nezt
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an WEED employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to
section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
® ached
Credit Card
Safe
http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgtBNbEY5 V%... 11/21/2016
EXTERIOR RESEARCH&DESIGN, LLC.
Certificate of Authorization#9503
TRINITY I 353 CHRISTIAN STREET, UNIT
QOERD OXFORD,Cr 06478478
PHONE:(203) 262-9245
FAX:(203) 262-9243
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-R7
One Owens Corning Parkway FL10674-1112
Toledo,OH 43659 Date of Issuance:02/06/2012
Revision 7: 04/18/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 51h Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.if the
product changes or the referenced Quality Assurance documentation changes. Trinity[ERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by: .tltjitt�
'rte O
zZ
_e y —
___
F R�,`•�."�`: The facsimile seal appearing was authorized by Robert Nieminen,
Robert J.M.Nieminen,P.E. �•rsa 'at4,;.`� P.E.on 04/18/2016.This does not serve as an electronically signed
Florida Registration No.59166,Florida DCA ANE1983 '.'�J""'r""� document.Signed,sealed hardmpies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY I ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Prope Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008
3. REFERENCES:
Entity Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
a
4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire®are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshirelm are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration®, TruDefinition® Duration®, Duration9 Premium Cool, TruDefinition® Duration® Designer Color
Collection, TruDefinition®Oakridge®, Oakridge® and WeatherGuardm HP are fiberglass reinforced, laminated
asphalt roof shingles.
0
4.2 Berkshire® Hip & Ridge Shingles, High Ridge, WeatherGuard HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidge'" Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7
Certificate of Authorization#9503 FL10674-1112
Revision 7:04/18/2016
Page 2 of 8
TRINITY I ERD
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for
use in all wind zones up to Vasd= 150 mph (V„it= 194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 All Owens Corning hip&ridge shingles,Starter Strip Shingle and Starter Strip Plus noted herein are Classified
in accordance with FBC Tables'1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are
acceptable for use in all wind zones up to Vasd=150 mph(V„It=194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations. Contact
the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.2 Asphalt Shinf[les:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following
exceptions:
➢ Berkshire shingles require minimum five(5)nails per shingle.
➢ WeatherGuarda HP shingles require minimum six(6)nails per shingle.
➢ Devonshire'"shingles require minimum six(6)nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Felt underlayment Deck Felt undedtymem Deck Saffadhered
Weathedock&
Self-adhered underlaymem
WeatherLocke
underlayment
Drip Drip edge edge
Drip edge
Nails locatedNaas located
2=V from cave r-3'from cave
Install first Self-sealing adhesive Sdieealing adhesive
Starter Strip positioned along eave wiInsth 6"first Smarter Strip Plus positioned along eave
shingle with with 6"removed
6"removed
Starter Strip shingle overhangs eaves and rakes'k=44" Starter Sdip Plus overhangs eaves and rakes 1/41-3/4"
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7
Certificate of Authorization#9503 FL10674-R12
Revision 7:04/18/2016
Page 3 of 8
TRINITY I ERD
6.2.6 Minimum Nailing—Classic®&Supreme:
Normal Mansard.or Area pare Normal Mansard or Aron;pare
1�nd.Arees High'Wind desvenes y Illlind h W
Areae Higind desvenes y
Area'pare Wakes norwales Areas viedt6s firertes Area para vientos riormalas Areas Worriesttierfes
t" .(A) ,r t• r: (B' z" t^.. r t"- t" (131 V 1'
tr rr u1 tz
5"Exposure 6 sib•Exposure
&poslefon Erpoiieidii
6.2.7 Minimum Nailing—Berkshire®:
S"but.striP. Sealant snip
da tlia:do seRado[ La lira de sellador
t B Yz" 9 Yf 9'Yf B Yt } "8 Yi" 8 lb" 8 Yt" 8w,
}
1 t•.J
r
i
1
Standard Fastening Pattern 6-Nail Fastening Pattern
Sealantstrip
La dra de sdk&r
t•8YC8Y, Bw
t'
r
2• Asp4ftroorrngcetnent
Cervanta do Wode as(allo
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7
Certificate of Authorization 1!9503 F1.10674-1112
Revision 7:04/18/2016
Page 4 of 8
TRINITY,ER®
6.2.8 Minimum Nailing—Devonshire'":
8"
7n I 1n
Clam
i" ••_^.^ Nails
r r e r
5318°exposure Sealant location 13-
Exposidbn de 5-5/8 pulg Ubiacion del sellador SW z
Ten 1"Spots of Asphalt Roof Cement
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing—Duration®,Tru Definition® Duration, Duration® Premium Cool &TruDefinition' Duration'
Designer Color Collection:
4-Nall Fastening Pattern 6-Nall Fastening Pattern
Su NaWfaskWnga"eaw1Qth S"heNaMtaseohga"cawAM
Nan,7ww N.L 7W.4
Y 127 12" 1• t^ +r 1 I 12. Y
c..Rr.�., .»-.�v�c �o:•�:=-. . swia�.�: as+.m+. n.ww rr.x^a.s s- _N.rra..e.cm:,.,wm_.M.-
67fa•66n^ Yc d4 i {'Y 61B6d9• ' s KR {, x I•?'
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
s�nN,ks1.,e,r,o .mm
N tYpka
r +r I 1 +r
f..-.
Pour t•sp,b,r A,ph,"R„flnp C-M
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-117
Certificate of Authorization#9503 FL10674-R12
Revision 7:04/18/2016
Page 5 of 8
TRINITY(ERD
6.2.1 Minimum Nailing—TruDefinition■Oakridge®,Oakridge®:
4 Nail Pattern 6 Nail Pattern
Esgrterna Torr 4 clavas Esgtrema con 6 cldvos.
r i•.,
lla i a s
i s
55/8"Exposure Was 5 518"Exposure.. Nab
Exposhidn de 55/8 pu1� Clavus E�tpaslcrbri deMs- pufq. 5 5/8"Exposure. CUy&S 5 6/8"Exposwe
Erpodd6nde'5619pulg. fxpostddn fe65/8pulp
Standard Fastening Pattern 6-Nail Fastening Pattern
Fasteiitrig for Slopes.Greater Than 21:12
&-H.d 9 r■sN■Mg w�WNmI
Ntll,lypkal
r tr tr
ms,om.a «a. ■.jos
S' 4 i + hk •
Four r Spot of rt,ph.N noxa g C—t
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard®HP:
■ ,— �,1VL1i Ltrra!
•• %i':••�~ ?� Firr�>R7l�w�t lllril Liw
Clrrri wr b fir do Rsl6r
Exterior Research and Design,I.L.C. Evaluation Report 037940.02.12-R7
Certificate of Authorization#9503 FL10674-R12
Revision 7:04/18/2016
Page 6 of 8
TRINITY I ERD
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire® Hip and Ridge Shingles, High Ridge, WeatherGuard® HP Hip and Ridge Shingles and
ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions, using four
(4) nails per shingle. Installation of DuraRidgeT" Hip & Ridge Shingles shall comply with the manufacturer's
current published instructions, using two (2) nails per shingle. Refer to Owens Corning published
information on wind resistance and installation limitations, including the use of hand-sealing for wind
warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge:
Fig.1 T. Fig.2
DirerDlreRla
ang Nlnd
n TopYiemr SIAeUleiv
Nails- A Mans. Nails
4
Top Lail atal r 1
A i i 4- Plea
A.
4 i 1
I I I
I I I
A 1 1 I I I
r r
al
�- 8►I -1
VI
1
I
1
I
I
1
6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge:
Fig.A q v
Fig.G Hip&Ridge.Shingle Fastening
Top Vlew
PreraaNg'MnC
�-Dlnac(bn p
A
Nails
A i i Naps Nails
z^
I I I I r r
I 1
I 1 I I
I
P S lle
-�
SElposule
t7,
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7
Certificate of Authorization 119503 F1.10674-1112
Revision 7:04/18/2016
Page 7 of 8
^
��TRINI—ry ����|"—'^�'
63.5 Minimum Nailing'Pro[dgeHip&Ridge Shingles:
Prevailing Standard
Wind Direction $,,,,,t Strip Fastening
Pattern
6,Exposure
12 Sealant
Fasten 71W 6"Expost to
Co xposed
fSWM
Hoof Cement
W.
6.3.6 Minimum Nailing—DumgUdge'" Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer toOwens Corning
published installation instructions for their minimum requirements.
ftmil[h Diroctfan Top View
cAm
wig
F44
7' LuasumG:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7'2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in Fo[
Table 15O7.2.7.1/R9O5.2.6l
8' BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9' MANUFACTURING PLANTS:
Contact the named QAentity for information on which plants produce products covered by Florida Rule 9N'3 CIA
requirements.
10' QUALITY ASSURANCE ENTITY:
ULLLC—[\UA9hI5;(414)Z48'64O9;
-
END OFEVALUATION REPORT-
Exterior Research and Design,uc Evaluation Report canmouzzz-Rr
Certificate w'x"m"m"uv"v95m ruouro'azz
Revision 7:04/18/2016
Page xv,o