HomeMy WebLinkAboutEngineeringPAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 E-mail pwelchinc@aol.com December 12, 2016 Re: Eubanks Re -Roof 10851 S Ocean Dr. #85 Jensen Beach, FL 34957 SCOPE OF WORK: Install new Metal Roof (Extreme Metal Fabricators, LLC "5-V Crimp" FL #17022.1) at above referenced address over new underlayment, and existing plywood sheathing. DESIGN CRITERIA: FBC 2014 ASCE?-10 PROJECT DATA: BUILDING HIEGHT=10'-0" A= 3' MEAN ROOF HIEGHT = <20' ROOF ANGLE = 4:12 SHAPE = PITCHED GABLE ADJUSTMENT FACTOR = 1.00 IMPROTANCE FACTOR = 1.00 WIND VELOCITY V ult= 165MPH WIND VELOCITY V asd = 128 MPH EXPOSURE = D ENCLOSURE CLASS = ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT = -0.18 APPLIED UPLIFT DESIGN PRESSURES PER ASCE (PSF): ZONE 1 (Field) = -40.3 ZONE 2 (Perimeter/ Ridge) = -68.0 ZONE 3 (Comers) = -99.8 10851 Ocean Dr. #85 Jensen Beach, FL Paul Welch Inc. Paul Welch P.E. Reg. No. 29945 December 12, 2016 1 of 3 METAL ROOFING ATTACHMENT REQUIREMENTS: Metal roofing to be attached with corrosion resistant Hex -Head wood screws #10 x 1 %" minimum with weather sealing washers (minimum 3/16" penetration through deck). Fasteners shall be placed through the panel ribs at 12" on center across panel width and spacing along the ribs as follows: ZONE 1 (Field): FASTENER SPACING = 16" O.C. ZONE 2 (Perimeter/ Ridge): FASTENER SPACING = 16" O.C. ZONE 3 (Comers): FASTENER SPACING = 8" O.C. NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF SLOPES UNDER 3 VERT. :12 HORZ. Design uplift Pressure for attachment as per above: Product Design Pressure: Zones 1 & 2:-93.5PSF / Zone 3:-101PSF Therefore O.K. UNDERLAYMENT: Underlayment shall be in accordance with manufacturer's guidelines, FBC 1507.4.5.1, and FBC 15074.5.2. Underlayment shall be Approved 30# Roofing Felt or UDL 25 plus NOA# 13- 0730.01. DECK INSTALLATION: Re -nail all plywood sheathing (15/32" thick minimum) with 8D ring -shank nails at 4" O.C. perimeter and 6" O.C. field for all zones. All work to be in compliance with product approval (FL # 17022.1), (NOA# 13-0730.01.), manufacturer's specifications, and the Florida Building Code 2014. 10851 Ocean Dr. #85 Jensen Beach, FL Paul Welch Inc. Paul Welch P.E. Reg. No. 29945 December 12, 2016 2 of 3 Axt ROOF ZONE PLAN A=3' 0,0,0= ZONE DESIGNATION (TYPICAL) NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF SLOPES UNDER 3 VERT. :12 HORZ. 10851 Ocean Dr. #85 Jensen Beach, FL a Paul Welch Inc. Paul Welch P.E. Reg. No. 29945 December 12, 2016 3 of