Loading...
HomeMy WebLinkAboutEngineering BENCHMARK ENGINEERING OF THE TREASURE COAST LLC. 806 Delaware Avenue, Fort Pierce, Florida 34950 PHONE(772)267-1399 December 14,2016 �J p Saint Lucie County Building Department Attn:Roof Permit Plan Review , 2300 Virginia Avenue ' C �y Ft.Pierce,FL 34982 G Re: Roofing specification prepared for the St.Lucie County Building Dept.for the structure located at,201 Hartman Rd.,Saint Lucie County,Florida Manufacturer: Gulf Coast Supply&Manufacturing Profiles: 26 Ga.5v Crimp FL#11651.13 R2 Code: FBC 2014;Section R 905.10 Wind Speed: 160 MPH;Ultimate Design Wind Speeds Exposure: B Mean Roof Height: 30'Maximum Pitch: 2.5/12 Minimum Required Design Pressure: Zonel:-38.2 Zone 2:-53.9 Zone3: -101.4 Maximum Uplift Pressure: Fastener spacing:-131.0 psf @ 9.5"-2"-9.5"&16"o.c., Fasteners: #9-15X1.5"with sealing washing through panel rib with''/,"minimum penetration through plywood Underlayment: Interwrap,Inc.NOA#13-0730.01,Titanium Psu-30,self-adhered,with minimum 3" horizontal laps&minimum 6"vertical laps.Place the first course of Titanium Psu-30 parallel to the eave and field,using a heavy pressure roller under safe conditions to further secure the membrane. Roof Decking: Existing plywood sheathing to be nailed w/8d x2"ring shank nails @ 6"o.c.thru out zone 1,4"o.c.perimeter&6"o.c.field Zone 2,and 4"o.c.thru out Zone3 The above approved,as per Florida Building Code Compliance acceptances,2014 Florida Building Code,and the Manufacturer's recommendations. ViUTC ocj`ift�r�SufS� -`,♦� �i ��