Loading...
HomeMy WebLinkAboutProduct Approval Models JX1200, JX1260, JX1330, JX1400 -Ser---ies- SAX,�.T '{ -. - r � i 3 '•F SPIT'r4 S.. h r • - '"t �}'ip C, ae_ _. .,. - ,�! /f,.f'�', � '" ,���.tr: ��xs.a}rr .',•.e�.+�'/�'d�r-ifL n a f Jxi - Gas- Fi r-ed ' ;/`''r �� � y4 fr/,ff ^•s r.,�:4i 4`K°.,J, ;. + > ;` ��J' '� J�f> r /r 1/ffr'•r• l�/j" 3� Pool-and Spa Heaters ��.�" K x, Jt i r•rif�r /: � �• J r",J,'�r ,r f /%ter' ! /- !r,/f'J j��'`.� "X, Is 3 f' I•". rs2 ^''. .. ..-s M. .<' >i77,. '�^x'• *tg:(• A. y �,Cr/r`fl f f^jj. f, ��! f�rfr / �Y/��/ i/.l �'r j .t 'sYss ��"�' Q .-� r 1, 'y --,I: >;';''F'� •- �Y` .nts.,. i4 :py,�f - ;^c.n. -r,.s�d•.r,-, x ..T- � '^7t '�•'£"Ee 9 .!.h s i�i LFSf r'' , v -s}y��y�rt� ij,i�•�5" {`-��p+#�Jr S` '�` �.r.�r �,b'•..`pH'k.��`t�' z;�� r`lsr .rd�'4rj-�`''4`,fi�. e'z'r S',,,'�a lry.� �."- t �•H` *.�Y�b'�` 9b 3� 9�F'��`.0 .'.. '�'r'���,�T• t- `c�� ��`�{R°k� y�� �x,; . r i, rG r S #A}!S stzz,rc .ws Ar H' Ar AV N General --------------------------------- ---- Minimum Clearance Minimum Service to At Least One Minimum Vertical Glearance,- Door Panel: 3611445 cm) Clearance 1811 (22.5 cm) US i from Header: 2411 (30 cm) Canada 1211 (40.6 cm) For detailed information,refer to the complete installation and owner's manual. I 5 Combustible Surfaces & Service Access i, II Installation on a non-combustible CombustiW Surfaces* surface is recommended. E, m Do not install on carpet. TOP. 6 inches(15 cm' This unit can be installed on EXHAUST SIDE: 6 inches(15 cm)from surface of the exhaust vent combustible flooring. HEADER SIDE: 6 inches(15 cm)'j SIDE PANELS: 6 inches(15 cm)'•) Service Access* TOP: 36 inches(45 cm) EXHAUST SIDE: 6 inches)(15 cm). from surface of the exhaust vent HEADER SIDE: 72 inches 30 cm), SIDE PANELS 18 inches(22.5 cm)US (at Least one]: 24 inches(60 cm) CAN 'Clearances are manufacturer's tested values_Theselare given as minimum values.Where local and national codes apply,and if the clearance values specified in the applicable codes are different that those listed in this nianual, use the greater value to ensure safest operation. i ffj For detailed information,refer to the complete installation and owner's manual. 6 k i I I I I I •I i ( j I s d III S I ( i.l 3 I� ,I .. ........ Distance:Heater to Door 'a ff -Z Q g-, USA-at least 4 feet(1.2m) g CAN-at least 10 feet(3.0m) Distance:Top of Heater to -OR C; INLET Vented Opening (Forced Air Inlet) .............. If the top of the heater is less than 3 feet(0.9m)above a vented -cg opening,the heater must be installed at least 10 feet(3.0m) awa53 41 y. 3 4,"4 "M R If the top of heater is more than -7- R 3 feet(0.9m)above,then any distance is acceptable. For detailed information,refer to the complete installation and owner's manual. In areas where there is high 1/4"X 2-1/4" risk of extreme weather Concrete Screws conditions,such as in Florida (and other states where there is risk as applicable), the heater is required to be securely fastened to the equipment pad to meet applicable local building code requirements. (Order Anchor Brackets Kit: Part Humber R0593400). Pre Drill Holes Prior to Screw Inslallalion CONCRETE EQUIPMENT PAD ANCHOR BRACKET 39