HomeMy WebLinkAboutProduct Approval (3) FILE m�
MIAMI. RECEIVED DEC 15 2 16
r � MIAMI-DADE COUNTY
RODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(REI2�EC EI%FED 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION 1 Miami,Florida 33175-2474
DEC 2 2016 T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
GAF PERMi-rTi%
1361 Alps Road. 5t.Lucie County, FL
Wayne,NJ 07470
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Seal-A-Ridge®and GAF Timbertex®Ridge Cap Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This revises NOA# 12-01011.14 and consists of pages 1 through 9.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 13-0306.08
MIAMI•DADE COUNTY
Expiration Date: 10/17/17
Approval Date: 08/15/13
Page 1 of 9
r
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Asphalt Shingles
Materials 3-Tab Perforated
Deck Type: Wood
SCOPE
This approves GAF Seal-A-Ridge®and GAF Timbertex®Ridge Cap Shingles as manufactured by GAF as described
in this Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
GAF Seal-A-Ridge®Ridge Cap 12"x 36" TAS 110 Hip and Ridge asphalt shingle with two
Shingle perforations 12 inches o.c. along the 36"length
Manufacturing Location#1,3 of shingle.
GAF Timbertex®Ridge Cap 12"x 12" TAS 110 A 12"x 36"prefabricated hip and ridge
Shingle fiberglass reinforced asphalt shingle with
Manufacturing Location#2 perforations at 12"sections.
PRODUCTS MANUFACTURED BY OTHERS
Product Product Size Manufacturer
Description
PL Polyurethane Roof&Flashing Sealant various Henkel PL
Sealant
NP-lTM Sealant various Sonneborn
MANUFACTURING LOCATION
1. Tuscaloosa,AL.
2. Mt. Vernon, IN.
3. Mobile,AL.
NOA No.: 13-0306.08
QMIAMI-DADB COUNTY Expiration Date: 10/17/17
Approval Date: 08/15/13
Page 2 of 9
EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
PRI Asphalt Technologies,Inc. TAS 100 ELK-078-02-01 06/21/02
TAS 100 GAF-125-02-01 04/04/06
Underwriters Laboratories,Inc. ASTM D3462 11CA45079 03/21/12
ASTM D3462 06CA18074 06/16/06
ASTM D3462 12CA30878 02/01/13
TAS 107 11CA45079 03/21/12
TAS 107 06CA18074 06/16/06
TAS 107 12CA38083 02/26/13
PRI Construction Materials Technologies LLC TAS 100 GAF-380-02-01 11/06/12
TAS 100 GAF-367-02-01 07/12/12
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. GAF Seal-A-Ridge® and GAF Timbertex® Ridge Cap Shingles shall be limited for use as hip and ridge cap
shingles only.
3. Shall not be installed on roof mean heights in excess of 33 ft.
4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 9N-3 of the Florida Administrative Code.
INSTALLATION
1. GAF Seal-A-Ridge® and GAF Timbertex®Ridge Cap Shingles shall be installed in compliance with Roofing
Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Nailing for GAF Seal-A-Ridge® Ridge Cap Shingles shall be in compliance with Detail `A' attached.
Exposure and course layout for GAF Seal-A-Ridge® Ridge Cap Shingles shall be in compliance with Detail
W.
5. Henkel PL Polyurethane Roof& Sealant or Sonneborn NP-lTM GunGrade must be used in the application of
GAF Seal-A-Ridge® Ridge Cap Shingles as specified in Detail A and GAF Timbertex® Ridge Cap Shingles
as specified in Detail B.
6. Nailing for GAF Timbertex® Ridge Cap Shingles shall be in compliance with Detail `B' attached. Exposure
and course layout for GAF Timbertex®Ridge Cap Shingles shall be in compliance with Detail `B'.
NOA No.: 13-0306.08
MIAMI DADE COUNTY
AD , Expiration Date: 10/17/17
Approval Date: 08/15/13
Page 3 of 9
LABELING
1. Shingles shall be labeled with the Miami-Dade Seal as seen below, or the wording"Miami-Dade County
Product Control Approved".
MIAMI-DADE COUNTY
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 13-0306.08
MIAMI•DADE COUNTY
Expiration Date: 10/17/17
Approval Date: 08/15/13
Page 4 of 9
DETAIL A
GAF Seal-A-Ridge®Ridge Cap Shingles Application Instructions:
(1) Step One—Separate each piece of GAF Seal-A-Ridge®Ridge Cap Shingles into three individual
ridge cap shingle pieces at perforations(see Figure 1).
Figure I
V.02
:1
06
xppsure,
(2) Step Two—Begin laying full ridge cap shingle with a 6-2/3"exposure beginning at the bottom of the
hip or from the end of the ridge opposite the direction of the prevailing wind(see Figure 2).
Figure 2
-0
A
-F
-Astenor
C
"T
-MAi NIP
NOA No.: 13-0306.08
MIAMI-DA E COUNTY
—WXVRM Expiration Date: 10/17/17
Approval Date: 08/15/13
Page 5 of 9
(3) Step Three—Apply ridge cap using 2 nails per piece 6-5/8"to 7-5/8"back from the exposed end and
1"to 2"up from the edge(see Figure 2 for location of nails).Use only zinc coated steel or aluminum, 10-
12 gauge,barbed, deformed or smooth shank roofing nails with heads 3/8"(9.5mm)to 7/16"(12mm)in
diameter. Nails should be long enough to penetrate at least 3/4" (19mm)into wood decks.or just through
plywood decks. Nails must be driven flush with the surface of the shingle. Over driving will damage the
shingle. Raised nails will interfere with the wind resistance of the shingles.
Special Application Section:
For Cold Weather Application
• In cold weather,warm GAF Seal-A-Ridge Ridge Cap Shingles before bending.
• When self-sealing is delayed due to cold weather, apply quarter-sized dabs of asphalt plastic
cement(must conform to ASTM D4586 Type I or Type II)between ridge cap pieces and press
firmly to insure good contact between pieces.
• Note:Excessive application of tab adhesive can cause blistering of ridge cap shingle.
For High-Wind Zones
• In high wind areas or for maximum wind resistance,apply a two quarter-sized dabs of Henkel
PL®Urethane Sealant to each ridge cap shingle approximatly 9"back from the exposed end and
1"from the shingle edge. (see Figure 3).
Figure 3
11.51 Sealant
1—(292 mm) V Sellante
(25 mm} (25 mm' Enduit d'6tanchdit6
Nail
Clavo 1m°
Clouer (305 mm)
9'
(229 mm)
12"
—(305 mm)�
For maximum wind speed coverage under ltd.warranty,apply
additional sealant as shown.See Special Application Section
for specific details.
Para el alcance maxima de velocidad de viento balo limitado
garantia,aplioa sellador adicional comp mostrado.Vea Seccion
Especial de Aplicaci6n para detalles especfficos.
Pour la couverture maximum de vitesse de vent sous iimM.la garantie,
appliquer de Penduit d'6tanch6it6 suppldrnentalre comma indiqu6.
Voir la section sp6ciale d'application pour les d6tails specifiques.
NOA No.: 13-0306.08
MIAMMADE COUNTY
Expiration Date: 10/17/17
Approval Date: 08/15/13
Page 6 of 9
DETAIL B
GAF Timbertexe Ridge Cap Shingles Application Instructions:
(1) Step One—Separate each piece of GAF Timbertee Ridge Cap Shingles into three individual ridge
cap shingle pieces at perforations(see Figure 1).
Figure I
M5rftT1
Self Seal.
Adhesive"
T
Aft''" Auto
Sellante err la
81 2o3mmI Perforations T,
V.
Parte Posterior
PE)�09T9i 999-s'
Adhesif Auto.:<
Perforations-.
Self Seal Adhesive on B2c1c- - q-'0m
Adhesivq Auto hte`6q-1a'P6fte osteri r' AP0Y9
I".f@
.rW
AdKkJfki iA AP -iJnf '
(2) Step Two—Prepare the starter course...For this step,take a 12" x 12" (305mm x 305mm)ridge cap
piece and cut along the line between exposure and headlap(see Figure 2).
Figure 2
Exposure- ' -
Nk-
cittp,
Starter-Course
�Oftoll'1'.�aC}CE,'r
in:S-oa 'Adhe_Oya'on Back;
NOA No.: 13-0306.08
MLAMI-DADE COUNTYM
�Wgmmqxmj� Expiration Date: 10/17/17
Approval Date: 08/15/13
Page 7 of 9
(3) Step Three—Place the 4" x 12" (102mm x 305mm) starter cap across the ridge starting at the bottom
of the hip or from the end of the ridge opposite the direction of the prevailing wind.
Note: For cold weather application or for high wind zones see special application section below.
(4) Step Four—Begin laying full ridge cap shingle pieces 12" x 12" (305mm x 305mm)as shown(see
Figure 2). Apply with an 8"exposure beginning at the bottom of the hip or from the end of the ridge
opposite the direction of the prevailing wind.
(5) Step Five—Apply ridge cap using 2 nails per piece 9"back from the exposed end and 1"up from the
edge(see Figure 3 for location of nails).Use only zinc coated steel or aluminum, 10-12 gauge,barbed,
deformed or smooth shank roofing nails with heads 3/8"(9.5mm)to 7/16"(12mm)in diameter. Nails
should be long enough to penetrate at least 3/4"(19mm)into wood decks or just through plywood decks.
Nails must be driven flush with the surface of the shingle. Over driving will damage the shingle. Raised
nails will interfere with the wind resistance of the shingles.
Figure 3
12"(305MM)
Top Larnin6d Piece
4° Pieza Superior Lamina&
102 Pi6ce Larninee Sup6rieure
#1'(25rnm) i 1°(25rnm)
i
t
Nail Fold Line Nail
Clavo Lima cle Pliegue Clavo
Clou Ligne Lie Pliage Clou
8°
203M m
Special Application Section:
For Cold Weather Application
• In cold weather,warm GAF Timbertex Ridge Cap Shingles before bending.
• When self-sealing is delayed due to cold weather;apply quarter-sized dabs of asphalt plastic
cement(must conform to ASTM D4586 Type I or Type 11)between ridge cap pieces and press
firmly to insure good contact between pieces.
• Note:Excessive application of tab adhesive can cause blistering of ridge cap shingle.
NOA No.: 13-0306.08
MIAMI•DADE COUNTY
Expiration Date: 10/17/17
Approval Date: 08/15/13
Page 8 of 9
For High-Wind Zones
• In high wind areas or for maximum wind resistance, apply a'/4"wide bead of Henkel PO
Urethane Sealant or Sonneborn®NP-1TM Urethane Sealant to each ridge cap shingle 3/4"-1"from
the shingle edge,parallel to the ridge(see Figure 4).
Figure 4
12"(305MM)
Top Laminated Rem
4v Pie2a Superior LaminadL
102 Piece Laminee Superieure
1_*.1'(2_Fmm) i V(25mm)
4
Nail I FokLLine Neil
Clavo I Linea de Pliegue Clavo
Clou Ligne De Pliage Clou
$r
2Q3M m
END OF THIS ACCEPTANCE
NOA No.: 13-0306.08
MIAMI-DARE COUNTY
. Expiration Date: 10/17/17
Approval Date: 08/15/13
Page 9 of 9