Loading...
HomeMy WebLinkAboutProduct Approval (5) MfAMt•DADE ,'�' E� ® MIAiVt-DADE COUNTX PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2596 F(786)315-2599 NOTICE OF ACCEPTANCE ( }.g,Com''a E D www.miamidad2.goy/economy Kennedy Skylights,LLC 5294 Tower Way DEC 2 0 2096 ,,; �`�� ` �_%Mff Sanford,FL 32773 PERIIIITTING SCOPE: St. Lucie County, FL This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHD). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code,including the High Velocity Hurricane Zone. DESCRIPTION: Series ICMG Aluminum Skylight APPROVAL DOCUMENT:Drawing titled"ICMG Subframe Plan,Deck Plan,Skylight Plan and Skylight Section",sheets 4 through 4 of 4,dated 07/01/2010,prepared by Kennedy Skylights, signed and sealed by James D.Wells,Jr.,P.E., bearing the Miami-Dade County Product Control renewal stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. NDSSILE IMPACT RATING:Large and Small Missile Impact Resistant LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo, city,state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT:The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA#13-0222.13 and consists of this page I and evidence pages E-1,as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M.Utrera,P.E. NOA No. 15-0922.16 CMMM Expiration Date:September 22,2020 Approval Date: December 31,2015 c 1 (/ J g Kennedy Skylights,LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing titled"ICMG Subframe Plan,Deck Plan, Skylight Plan and Skylight Section", sheets 4 through 4 of 4, dated 07/01/2010,prepared by Kennedy Skylights, signed and sealed by James D. Wells,Jr.,P.E. B. TESTS "Submitted under NOA#09-0630.09" 1. Test reports on 1)Air Infiltration Test,per FBC,TAS 202-94 2)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94 3)Water Resistance Test,per FBC,TAS 202-94 4)Large Missile Impact Test per FBC,TAS 201-94 5) Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of Series ICMG Aluminum Skylights,prepared by National Certified Testing Laboratories,Test Report No. 210- 3041-1,2, dated 10/05/2004, signed and sealed by Gerald J.Ferrara,P.E. C. CALCULATIONS "Submitted under NOA #09-0630.09" 1. Anchor calculations prepared by J&L Wells Consulting LLC, on 08/04/2010,signed and sealed by James D. Wells,Jr.,P.E. D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources(RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-1105.08 issued to Cardinal LG Company for their "Cardinal Sea-Storm PET Glass Interlayer", approved on 02/12/2015 and expiring on 01/13/2016. F. STATEMENTS 1. Statement letter of code conformance to the 5th edition(2014)FBC issued by J&L Wells Consulting LLC,dated 09/15/2015, signed and sealed by James D.Wells, Jr., P.E. 2. Statement letter of no financial interest issued by J&L Wells Consulting LLC, dated 09/15/2015,signed and sealed by James D. Wells, Jr.,P.E. Carlos M.Utrera,P.E. Product Control Examiner NOA No. 15-0922.16 Expiration Date:September 22,2020 Approval Date:December 31,2015 E-1 ez 47.500 DESIGN PRESSURE RATING ± GO PSF LARGE MI55ILE IMPACT RESISTANT N 3.250 8.500 8.500 7.000 8.500 8.500 3.250 of CL \\�111I11111//// NOTE: j PR0DUCTPXaa (1) ALL ROOFING AW"�r �°�" �* D•53616*'-__ DETAILS SHALL COMPLY �!►� 9YA WITH FLORIDA BUILDING OF CODE 5th Edition(2014). I M Poduct°°°°^� co (2) 4" MINIMUM I DISTANCE FROM ANGLE j FASTENER SCHEDULE— LIP TO ROOF SURFACES o j IS FOR SHINGLE OR j SKYLIGHT FRAME TO B.U.R. WITHOUTWOOD SUB—FRAME INSULATION. FOR #8x1 " FLATHEAD SELF- I 8x13'4" FLAT HEAD SELF TAPPING SCREWS INSULATION AND TILE TAPPING SCREW I # I QTY. PER LONG QTY. PER ROOF ADD TILE HEIGHTMODEL o o Cy7 — --- -TEST MODEL ICMG 4648 ----------- - -- SIDE SHORT SIDE AND INSULATION tq E-: I 4646 s s THICKNESS TO 4". " j 3046 6 4 o 3030 4 4 (3) ANCHORS TO BE i 2269 9 3 MADE FROM co 2246 6 3 NON—CORROSIVE I 2230 4 3 MATERIAL COMPATIBLE 2222 3 3 WITH ALUMINUM. g 1446 6 2 (4) NO ONE—THIRD to I 1430 4 2 INCREASE IN THE DESIGN j 2 3 2 PRESSURE WAS USED. 141422 2 12 (5) TESTED TO TAS 201, TAS 202,AND TAS 203. I � I N I ri • —WO Pa ARA Mk PROD=RI ftf..-of Rsoord:I—D.Ws6s,Jn,P.S. DEV.DATE DESOWPNON B°T KENNEDY SKYLIGHTS, LLC icMG P�f° °°° s Consulting No.53616 r J&L Wsnlls CoasulLLo6 LLC J SUBFRAME PLAN 1453 Arbitus Clrole c z Mud DY.•GNR'lg°eY: owmro rss Oviedo,J7.32706 (407)406-5480 ^ RV N CertlRoste of Authorization No.27102 Of 57.500 UNIT DIMENSIONS 5.250 V5.00O v 8.500 v 8.500 v 6.500 le 8.500 8.500 v3.600 1.250 MODEL LONG SIDE SHORT SIDE 4646 57.5 57.5 3046 57.5 41.5 i 3030 41.5 41.5 to ai 2289 80.5 33.5 2246 57.5 33.5 2230 41.5 33.5 co 2222 33.5 33.5 1446 57.6 25.6 1430 41.5 25.5 1422 33.5 25.5 i 1414 25.5 25.5 118x1j" MODIFIED TRUSS e�topucr rsern weo HEAD SCREWS es aoDplr►Dpwltb the iMtWa A` � ! FASTENER SCHEDULE CURB TO DECK Ry o — --- -------------------- I — —— —— — — — --- ------ MI uct ProdCOMA O #6x16/6" DRYWALL SCREWS to o � MODEL QTY. PER LONG QTY. PER SIDE SHORT SIDE co 4848 8 6 ONVID V1 3046 8 6 3030 6 6 3616 C 2269 11 5 O 9a' tvtt J++= OF 1%, � WELDED CORNERS � 2246 8 5 2230 6 5 2222 5 5 /HA�1\\\�\ o 1446 B 4 o tti 1430 B 4 N 1422 5 4 1414 14 14 oalsaos P"PM—tate Psomcr NII@ DESICMG Saglneer of Reoord:Jemes D.AeDs,Jn,P.2.KENNEDY SKYLIGHTS LLC 7rroleoslonal bS Comer No.53010JDECK PLAN J kb S Ra ltus C rel trc :Ew 1489 Arbltua Cira7aDRIIN er• 0407) fZ 648Q(407)400—W60L { jZS7 Rt/ Certmcelo of Authorisation No.27162 01 r DESIGN PRESSURE RATING ± GO PSF 50.750 LARGE MISSILE IMPACT RE515TANT v� 4.750 11 13.750 v 13.750 13.750 4.750 rE I I I o I i FASTENER SCHED ULE- #axis" PHILLIPS TRUSS i SKYLIGHT TO CURB HEAD SCREW #Bxl a„ PHILLIPS TRUSS HEAD SCREWS wtoDtic7> i MODEL QTY. PER LONG QTY. PER SIDE SHORT SIDE e wimmoekdde (5 I`L i 4646 4 4 sxph�oo �, o o i 9046 4 3 t` r-- - ----------- — 3030 3 3 ,Nw- ,W r«.rd ----------1-------------------- i 2269 5 3 i 2246 4 3 i 2230 3 3 2222 3 3 1448 4 2 o 1430 3 2 _ 0. 3616 1422 3 %`*vI( W— WELDED CORNERS I 1414 12 12 .w STATE OF z� i j�y �OR1Dr t4``� I fit 111% V I I o � I eRAWaloa PREPARED Pok PRolrCf IMM Engineer of Record:James D.N'eft Jr.,P.B. q REV,UAD: OESCRIMON KENNED Y SKYL I GHTS LLC ICMG I§ofeeaEngineerN63616 J&L L Irall. ila Consuleultirg�ILC J SKYLIGHT PLAN 1463 Arbllus Mrale a murN By.rasow an numa MEOPIeEo,FL 327ab N (407)IBB—Wag 4f RV RV Certificate of Authorization No.27!82 301 4 , NOTE: CURB SUPPLIED/ INSTALLED BY OTHERS, (APPROVED BY MIAMI—DADE COUNTY) `,��11111111//ll� CONTINUOUS BEADED STRUCTURAL FoDUCTRMEWED e pl wlt6 &ral SILICONE AecepraeWa ' >r Z E` =* 0.5361B * v llq" FLATHEAD SELF— ny =0 If I{ Jlq� TAPPING SCREW. OF SEE TABLE FOR QUANTITIES, �'��1P Q<ORIO► (+)��� SEE PLAN FOR SPACING ��i�'/" kA41 WOOD GLAZING FRAME EXTRUDED ALUMINUM SKYLIGHT FRAME Al #6x18" PHILLIPS TRUSS HEAD SCREW. SEE TABLE FOR QUANTITIES, SEE PLAN FOR SPACING. I I tier GLASS PANEL I .090 PVB 1/2., I A" GLASS PANEL SHIM AS NEEDED FOR SNUG FIT PVC CONDENSATION GUTTER .060" CONTINUOUS ALUMINUM FLASHING I ROUGH OPENING I 118x1j" MODIFIED TRUSS HEAD SCREW. " SEE TABLE FOR QUANTITIES, SEE PLAN FOR SPACING. NOTE. I 4" IMPACT TEST WAS A 2x6 STUD. CURB AND 1 FLASHING BY OTHERS AS PER MIAMI—DADE t SPECIFICATIONS. - -— TRUSS. - OVERALL CURB DIMENSION MM-PiuP eex P8018e1 N,um �REV.OAIE OESCRIPOON KENNEDY SKYLIGHTS LLC ICMG �R>oaer of Record: Consulting gene, P.R. Proressloael&w1sear No.69610 J&L hells Coaeultln2 LLC SKYLIGHT SECTION 1463 ArEltue Circle 88diN OT CI6T;A'e 8Y: DRA►Ma r8B Oviedo,FL 32766 (107)106-6469 ^ RV RV Certulaete o1 Authorization No.27182 Of