Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 4 �...,, Business i II< & Profesiional Reoulation ` BCIS Home I Login User Registration ! Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search €lolida r r P°,� Product Approval USER:Public User -n oa a Product ADDroyal Menu>Product or Application Search>Application List>Application Detail •2 FL# FL1956-1112 i Application Type Editorial Change Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived ❑ Product Manufacturer TAMKO Building Products,Inc. Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri_eden@tamko.com Authorized Signature Kerri Eden kerri—eden@tamko.com Technical Representative Kerri Eden Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 ke rri_ed en @ta m ko:co m I Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Certification Mark or Listing Certification Agency UL LLC Validated By Robert J. M, Nieminen, PE Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards Certified By I Product Approval Method Method 1 Option A i Date Submitted 09/17/2015 htt-os:HfloridabuildinR.or�/pr/pr app dtl.ast)x?param=wGEVXOwtDas%2fmGFovT6raO... 12/19/2016 Florida Building Code Online Page 2 of 4 Date Validated 10/06/2015 Date Pending FBC Approval Date Approved 10/09/2015 Summa of Products FL# Model,Number Description or Name 1956.1 Elite Glass-Seal A three tab asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.pdf HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL19S6 R12 II Glass Seal Elite Glass Seal app inst.pdf Other:Asphalt shingles Verified By: Robert Nieminen 59166 shall be used only on roof Created by Independent Third Party: No slopes of 2:12 or greater. Evaluation Reports Nails must be used as the Created.by Independent Third Party: method of attachment. 1956.2 1 Glass-Seal A three tab asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.pdf HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure: N/A FL1956 R12 II Glass Seal Elite Glass Seal app inst.odf Other:Asphalt shingles Verified By: Robert Nieminen PE 59166 shall be used only on roof Created by Independent Third Party: No slopes of 2:12 or greater. Evaluation Reports Nails must be used as the Created by Independent Third Party: method of attachment. 1956.3 1 Heritage A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 201S.pdf HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.odf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure: N/A FL1956 R12 II Heritage D F J P app inst.gdf Other:Asphalt shingles FL1956 R12 II Heritage F app inst.pdf shall be used only on roof FL1956 R12 II Heritage T app inst.pdf slopes of 2:12 or greater. Verified By: Robert J. M.Nieminen FL 59166 Nails must be used as the Created by Independent Third Party: No method of attachment. Evaluation Reports Created by Independent Third Party: 1956.4 Heritage 30 A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015 Ddf HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.Ddf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 R12 II heritage 30 app inst april 10.Ddf Other:Asphalt shingles FL1956 R12 II heritage 30 app inst f april 10.Ddf shall be used only on roof Verified By: Robert Nieminen PE 59166 i slopes of 2:12 or greater. Created by Independent Third Party: No Nails must be used as the Evaluation Reports method of attachment. Created by Independent Third Party: 1956.5 1 Heritage 50 A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Serv'Conf FL 1956 2015.pdf HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 R12 II heritage 50 app Inst aoril ,10.Ddf Other:Asphalt shingles FL1956 R12 II heritage 50 aim Inst f anril 10.pdf shall be used only on roof Verified By: Robert Nieminen PE 59166 slopes of 2:12 or greater. Created by Independent Third Party: No Nails must be used as the Evaluation Reports method of attachment. Created by Independent Third Party; https:Hfloridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtD'gs%2fmGFoyT6raQ... 12/19/2016 Florida Building Code Online Page 3 of 4 1956.6 Heritage Premium A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015 rdf HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.rdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 R12 II Heritage Premium D P app inst.rdf Other:Asphalt shingles FL1956 R12 II Heritage Premium F aro inst.odf shall be used only on roof FL1956 R12 II Heritage Premium T art) inst.pdf slopes of 2:12 or greater. Verified By: Robert Nieminen 59166 Nails must be used as the Created by Independent Third Party: No method of attachment. Evaluation Reports Created by Independent Third Party: 1956.7 1 Heritage Vintage A heavy weight dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.pdf HVHZ: No FL1956 R12 C CAC UL shingle matrix.rdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure: N/A FL1956 R12 II Heritage Vintage app inst.rdf Other:Asphalt shingles Verified By: Robert J. M.Nieminen PE 59166 shall be used only on roof Created by Independent Third Party: No slopes of 2:12 or greater. Evaluation Reports Nails must be used as the Created by Independent Third Party: method of attachment. 1956.8 Heritage Vintage Hip and ridge shingles 12 X 12 Hip and Ridge Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.t)df HVHZ:No FL1956 R12 C CAC UL shingle matrix.rdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 R12 II TAMKOCg) Heritage(g) 12 x 12 Hir and Ridge Arplication Instructions.pdf Other:Asphalt shingles Verified By: Robert J. M. Nieminen PE 59166 shall be used only on roof Created by Independent Third Party: No slopes of 2:12 or greater. Evaluation Reports Nails must be used as the Created by Independent Third Party: method of attachment. 1956.9 Heritage A dimensional asphalt shingle. Woodgate Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Ta'mko Sery!Conf FL 1956 2015.pdf HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure: N/A FL19S6 R12 II Heritage Woodgate D app inst.pdf, Other:Asphalt shingles FL1956 R12 II Heritage Woodgate F aro inst.rdf shall be used only on roof Verified By: Robert Nieminen 59166 slopes of 2:12 or greater. Created by Independent Third Party: No Nails must be used as the Evaluation Reports method of attachment. Created by Independent Third Party: 1956.10 1 Heritage XL A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Serv�Conf FL 1956 2015.1)df HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.t)df Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 R12 II heritage xl app inst d april 10.rdf Other:Asphalt shingles FL1956 R12 II heritage A aup inst f april Modf shall be used only on roof Verified By: Robert Nieminen PE 59166 slopes of 2:12 or greater. Created by Independent Third Party: No Nails must be used as the Evaluation Reports method of attachment. Created by Independent Third Party: 1956.11 Hip and Ridge Hip and ridge shingles Shingles Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL'1956 2015.1)df HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.odf https://floridabuilding.org/pr/P _app_dtl.aspx?param=wGEVXQwtDgs%2fmGFoyT6raQ... 12/19/2016 Florida Building Code Online Page 4 of 4 Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 R12 II 12.25x12 Hip and Ridge.pdf Other:Hip and Ridge FL1956 R12 II 12 x 12 Hin Ridge Application Instructions.Ddf shingles shall be used only FL1956 R12 II 12-1-4x12 HipRidge Sealant Dab Illustrations.nd on roof slopes of 2:12 or FL1956 R12 II 12x12 HiDRidge Sealant Dab Illustrations.odf greater.Nails must be used Verified By: Robert Nieminen 59166 as the method of Created by Independent Third Party: No attachment. Evaluation Reports Created by Independent Third Party: Back Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click Isere_. Product Approval Accepts: ® ® eCAeck M Credit Card' Safe https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQ WtDgsg/o2fmGFoyT6raQ... 12/19/2016 ® Application Instructions-for TAMKO HERITAGE® 30 BUILDING PRODUCTS LAMINATED.ASP®ALT SHINGLES. Dallas,TX •Tuscaloosa,AL• Phillipsburg, KS • Joplin., MO. THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE.ROOFING.CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS;INC.ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING FROM FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS. THIS PRODUCT IS COVERED BY A LIMITED WARRANTY,THE.TERMS OF WHICH ARE PRINTED ON THE WRAPPER. IN COLD WEATHER(BELOW 40°F),CARE MUST BE TAKEN TO AVOID DAMAGE TO THE EDGES AND CORNERS,OF THE SHINGLES. IMPORTANT It is not necessary to remove the plastic strip from the back of the.shingles. . 1:ROOF DECK S.FASTENERS These shingles are for application to roof decks capable of receiving WIND CAUTION: Extreme wind velocities can damage these and retaining fasteners-,and to inclines of not less than 2 in.per foot. shingles after application when proper sealing of the shingles For roofs having pitches 2 in:per foot to less than 4 in..per foot,refer does not occur.This can especially"be a problem if the-shingles to special instructions titled"Low Slope Application".Shingles must are.applied in:cooler months or in areas-on the roof that do not be applied_properly.TAMKO assumes;no responsibility for leaks or receive direct sunlight.These conditions may impede the sealing defects resulting from improper application,or failure to properly of the adhesive strips on the shingles.The inability to seal down prepare the surface to be roofed'over. may be compounded by prolonged cold weather conditions and/ NEW ROOF DECK CONSTRUCTION.•Roof deck must be smooth, or blowing dust.In these situations,hand sealing of the shingles is dry and free from warped surfaces. It recommended that metal recommended.To insure immediate sealing,apply 4 quarter-sized drip edges be installed at eaves and rakes. dabs of TAM-PRO Premium SBS Adhesive.or TAMKO.Tam-Seal Adhesive on the back of the shingle 1 in.(25mm).and.13 in.(330mm) PLYWOOD:All.plywood shall be exterior grade as defined by the in from each side and 1 in. (25mm) up from the bottom of the Engineered Wood Association.Plywood shall be a minimum of 3/8 shingle.Press shingle firmly`into the adhesive.For maximum wind in.thickness and applied in accordance with the recommendations resistance along rakes,cement shingles to the underlayment and of the Engineered Wood Association. each other in a 4 in.(102mm)width of TAM-PRO SBS Adhesive or .SHEATHING BOARDS• Boards shall be well-seasoned tongue- TAMKO Tam-Seal Adhesive.;Caution:Apply ONLY a thin.uniform and-groove boards and not over i-m nominal width.Boards.shall. layer of adhesive less.than 1/8 in.(3mm)thick.Excessive amounts.. be a 1 in. nominal minimum thickness. Boards shall be properly can cause blistering of the shingles and may soften the asphalt in spaced.and.nailed. certain underlayments resulting in the asphalt flowing,dripping and staining.Shingles must also be fastened according to the fastening Z:VENTILATION instructions described below. Inadequate ventilation of attic spaces can cause accumulation of Correct placement of-the fasteners is critical to the performance moisture in winter months and a build up of heat in the summer. of the shingle. If the fasteners are-not placed'as shown in the These conditions can lead to: diagram and described below,this will result in the termination-of TAMKO's liabilities under.the limited warranty.TAMKO will.not be 9:Vapor Condensation, responsible for:damage to shingles caused by winds-in excess of. 2.Buckling of shingles due to deck movement. the applicable mph as stated in the limited warranty. See limited S.Rotting of wood:members. warranty for details. FASTENING PATTERNS:Fasteners must be placed-6-1/8 in.from 4.:Premature-failure of roof. the bottom edge of the'shingle,penetrating through the common bond,and located horizontally as follows: To insure-adequate ventilation and circulation of air,place louvers of sufficient size high in the gable ends and/or install continuous 1)Standard Fastening Pattern.(Foruse on decks with slopes 2 In. ridge and soffit vents.:FHA minimum property standards require per foot to 21 in.per foot.)One fastener 1 in. back from each end one square foot of net free ventilation area to each 150 square feet and one 13-1/2 in-back from each arid of the shingle.for a total of 4 of space to be vented,or one square foot per 300 square.feet if a fasteners.(See standard fastening pattern illustrated below). vapor barrier,is installed on the warm side of the ceiling or if at least one half of the ventilation is provided nearthe ridge.If the ventilation STANDARD FASTENING PATTERN openings are screened,the total area should be doubled. FASTENERS NAIL ZONE COMMON BOND IT IS PARTICULARLY IMPORTANT TO PROVIDE g-1l8" ADEQUATE VENTILATIOM EXPOSURE 5.5/8^ 4- P., 1" h- 12-1/2'-+-,12-3/8°-►� 12-1/2'-+ h-1" (Continued) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 1,110e Visit Our Web Site at Northeast District. 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamko.eom Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 4.3rd Ave., Denver,CO,.80216 800-530=8868 1 ® (CONTINUED from-page 1) TAMKO HERITAGE® 30 BUILDING PRGDUCTS LAMINATED ASPHALT SHINGLES Dallas,TX a Tuscaloosa,AL• Phillipsburg, KS • Joplin, MO 2) Mansard Fastening Pattern. (For use on.decks with slopes be a minimum of 1-1/4 in.for new construction and 1-1/2 in:.for greater than 21:in.per foot:)One fastener 1 in.back.from each end reroofing thus allowing a minimum deck.penetration of 3/4 in.The and one fastener 8-1/2 In.back from each end and one fastener 16 crown of the staple must be paralleCto the length of the shingle. in.back from each end for a total of 6 fasteners per shingle.(See The staple crown should be,driven flush with the shingle surface. Mansard and High Wind Fastening Pattern illustrated below.) Staples.that are crooked,underdrivedor overdriven are considered MANSARD AND-HIGH WIND FASTENING PATTERN improperly applied: FASTENERS LZ Properly Driven Improperly Driven COMMON underdriven overdriven crooked BONDN Asphalt Shingles FEV'OSURES-SM" a r •E �Decking 3) High Wind Fastening Pattern. (For High Wind Application CAUTION:ALL FASTENERS MUST BE DRIVEN INTO THE NAIL reguirements).One fastener 1 in..back from each end:One fastener ZONE/COMMON,BOND.AS SHOWN IN THE DIAGRAM ABOVE. 8-1/2 in..back from each.end and one fastener 16 in.back from each 4.UNDEBLAVMENT end fora total of six(6)fasteners per shingle.In addition to this shingle fastening pattern requirement for High Wind Application, TAMKO UNDERLAYMENT An underlayment consisting of asphalt saturated also requires the use of the-following TAMKO products: TAMKO felt must be applied over the entire deck before the installation of felts or underlayments;TAMKO Moisture Guard Plus underlayment TAMKO shingles.Failure to add underlayment can cause premature at all eaves,rakes,and valleys;TAMKO or TAM-PRO cements and failure of the shingles which is not covered by TAMKO's limited coatings products where required;TAMKO ventilation where required, warranty..Apply the felt when the deck is dry.On roof decks 4 in. TAMKO startershingles if available in area,and TAMKO Hip and Ridge per foot and greater apply the felt parallel to the eaves lapping each shingles installed on all hips and ridges.Along rakes,cement shingles course,of the felt over the lower cou'rse at least 2 in.Where ends to the underlayment and each other in a 4 in.(102 mm)width of TAM- join, lap.the felt 4.in. If left exposed, the underlayment felt may PRO SBS Adhesive or TAMKO Tam-Seal Adhesive.Also,see local be adversely affected by moisture and weathering. Laying of the building codes for proper nailing application.High Wind Application underlayment and the shingle application must be done together. is offered on new construction or complete tear-off applications only. Products which are acceptable for use as underlayment'are: It is not offered.for recover applications. If High-Wind Application requirements are not followed,the High Wind Application Warranty — TAMKO No:15 Asphalt Saturated Organic Felt MPH, as stated on Table I in the Limited Warranty,reverts to the — A non-perforated asphalt saturated organic felt which meets Standard Application Wind Warranty MPH limit.(See Mansard and ASTM:D226,Type I orASTM,D4869,Type I High Wind:Fastening Pattern illustrated above.) Any TAMKO no asphalt saturated organic felt — TAMKO TW Metal and Tile Undedayment,TW Underlayment NAILS:TAMKO recommendsthe use of nails as the preferred method and Moisture Guard Pluse (additional.ventilation may be of application- Standard type roofing nails should be used. Nail required.Contact TAMKO's Technical Services Department shanks should be made of minimum 12 gauge wire,and a minimum for more information:) head diameter of 3/8 in.Nails should be long enough to penetrate 3/4 in,into the roof deck.-Where the deck is less than 3/4 in.thick, In areas where ice builds up along the eaves or a back-up of water the nails should be long enough to penetrate completely through from frozen or clogged gutters is al potential problem,TAMKO's plywood decking and extend.at least 1/8 in.through the roof deck. Moisture Guard Plus®waterproofing underlayment(or any specialty Drive nail head flush with the shingle surface. eaves flashing product) may be applied to eaves, rakes, ridges, valleys, around chimneys, skylights or dormers to help prevent Properly Driven Improperly Driven water damage.Contact TAMKO's Technical Services-Department - a'�3�8'mindlemeter underdriven overdrNan Brooked for more information. r Asphalt shingles. TAMKO does not recommend the use of any substitute products Et � Decking as shingle underlayment. �! W nanl.al S.APPLICATION INSTRUC'T'IONS straight,good panetratlon, Inadequate too deep,cuts Inadequate ,and flush wlM shingle earfeGa panmrauae Ima shlagt^ a^ch^rey° STARTER COURSE:A starter course may consist of TAMKO Shingle Starter;self-sealing 3-tab shingles or a 9 inch wide strip of mineral STAPLES: If staples are used in the attachingprocess,follow the surface roll roofing.If self-sealing 3-tab shingles are used,remove above instructions for placement.All staples must be driven with the exposed tab portion and install with the factory applied adhesive pneumatic staplers:The staple must meet the following minimum adjacent to the eaves. Attach the starter course with approved dimensional requirements..Stapies must.be.made from.a minimum fasteners along aline parallel to and,3 in.to 4 in.above.the eaves 16 gauge galvanized wire.Crown width must be at least 15/16 in, edge.The starter course should overhang both.the eaves and rake (staple crown width is measured outside the legs).Leg length should edges 1/4 in.to 3/8 in. (Continued) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11/09 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamko.colm Southwest District 7910 S.Central Exp., Dallas,.TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 860-530=8868 2. ® (CONTINUED from page 2) TAMKO HERITAGE® 30 BUILDING PRODUCTS LAMINATED.ASPHALT SHINGLES. Dallas, TX •Tuscaloosa,AL• Phillipsburg, KS.• Joplin, MO .SHINGLE APPLICATION:Start the first course with a full size shingle S.LOW SLOPS APPLICATION and overhang the rake edge 1/4 in.Cut 10-3/8 in.from a full shingle On pitches 2 in.per foot to 4 in:perfoot coverthe deckwith two layers . to form a shingle 29 In.long.Use this to start the second course(see of asphalt saturated-felt.Begin by applying the felt in a 19 in.wide strip diagram below).Cut a23 in.long shingle to startthe third course.Use along the eaves and,,overhanging the drip edge by 1/4 to 3/4 in.Place the remaining 16=318 in.-piece of shingle to start the fourth course and a full 36 in.wide sheet over the 19 in.wide starter piece,completely use the remaining 10-3/8 in.piece to begin.the fifth course.Continue overlapping it.All succeeding courses will be positioned to overlap the up the rake in as-many rows.as necessary using the same formula preceding course by,19,in.If wintertemperatures average 25eF or less, as outlined above.The butt of the shingle should be aligned with thoroughlycement the felts to each other with.TAM-PRO or TAMKO the top edge of the sawtooth of the underlying shingle for a 5-5/8 in. Plastic Roof Cement from eaves and rakes to a point of a least 24 in. exposure(see shingle application drawing illustrated on this panel). inside the interior wall line of the building.As an alternative,TAMKO's When you make your final cut at the roof's edge,flip any pieces that Moisture Guard Plus®self-adhering waterproofing underlayment may are 8 in.or longer back onto the roof.These pieces can be worked be used in lieu of the cemented felts. in anywhere without creating zippers or color variations. i NOTE:Do not align joints of shingle courses when working in cut 7•MUSARD 600E OR STM SLOPS HOOF pieces.Joints should be no closer than 4 in.from one another. If the slope exceeds 21 in.perfoot(601,each shingle must be sealed with TAM-PRO SBS Adhesive or TAMKO Tam-Seal Adhesive immediately upon installation.Spots of cement must.be equivalentin size to a$.25 piece and applied to shingles with a 5-5/8-in.exposure,use 6 fasteners IG-3f8"rile° per shingle.See Section 3 for the Mansard Fastening Pattern. B.RS-HOOFING repeat 16-3/8" 29' Before re-roofing,be certain to inspect the roof decks.All plywood - 23' shall meet the requirements listed in Section 1. 2s y F..'81"INail down or.remove curled or broken shingles from the existing 23' roof.Replace all missing shingles with new ones to provide a smooth rake '" " `Fun base. Shingles that are buckled usually indicate warped decking or protruding nails' Hammer down all protruding nails or remove them and refasten'in a new location. Remove all drip edge metal 5th course - z3° is•3fa° and replace with new. 4th course j116-$3/8' , If re-roofing_over an existing roof where new flashing is required 3rd course toprotect against ice dams(freeze/thaw cycle of water and/or the zea coufsezs backup of water in frozen or clogged gutters),remove the old roofing 291.1 to a point at leasV24 in. beyond the interior wall line and apply tat course Fall 10-3/9" TAMKO's Moisture Guard Plu&,waterproofing undenayment..Contact —eave . TAMKO's Technical Services Department for more information. Measurements will:vary when nesting over.an existing 5 in.exposure single roof;Call TAMKO Technical Services for further information. cut your first course shingle to m..29•and a 10 3/9• i- alength.Cut a second shirgletomakea23'and _ The nesting procedure described below isthe.preferredmethod for e 16 3/e'length. - ,0 3 a reroofing over existing metric size shingles with a 5-5/8 in.exposure. 29' i See description below: Starter Course:Remove the tabs and an additional portion from the head of a full size shingle so.that its height is equal to the exposure of the.existing shingles.Position the resulting strip over the existing roof edge(with the factory-applied adhesive strip along the eaves). Cut approximately 6 in.from the rake;end and apply the remaining portion at the eaves.Continue the starter strip by applying full length shingle strips cut to height-as above,evenly along the existing roof at the eaves.The existing'roof should overhang the eaves far Z•Begin appllcason with aful(engin shingle. Then lay your 29':23',163/8'and 10�'lengths. enough to can water off into the gutter.If this is not the case. Asyou censure,three shingles with lwo rets make five coeth cut and apply the:starter strip so that it will provide sufficient overhang for proper drainage. 3.finaConle t at Me recta edgayacross msesthatWhen you mahot longer your First Course:Remove an amount from the butt edge of:a full-size final o t at real. The edge,fllp any pieces that are 6'a longer back atingtmemo+.Tlor variations. be waked in erywhere without shingle sothat the remaining,.portion of the shinglefits between the creating rippersorwlor raragons. NOTE:Do not align Jalnts of shingle.courses when working In butts of the existing third course.This course must also be applied cut pleces.Joints should be no closer than 0•from am another. evenly along the eaves edge of the new starter strip. (Continued) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 tt/os Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamko.colm Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District- 5300 East 43rd Ave., Denver,CO.j80216: 8d0-530-8868 3- ® (CONTINUED from:page 3) . ._ .' . .:.[TAMKO HERiTAGEO- 30 OU160ING PRODUCTS LAMINATED ASPHALT SHINGLES. Dallas,TX •Tuscaloosa,AL• Phillipsburg, KS • Joplin., MO Second and Succeeding Courses: Remove 10-3/8 in.from the FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE rake end.of the first.shingle.in the second course, and continue. CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT. with-full width shingles for the remainder of the.course,.placing the top edge of each new shingle against the butt edge of the old val,ey cerderfine Minimum 36'wide sheet shingle in the course above.This method should create an exposure of Neil Fast,Moisture b. of 5-5/8 infafter the first course.When beginning the succeeding orhGuardPdrroll In and ofshn e9. 9 9 or Beamer con mell� - end of shingle courses continue to follow the Heritage application instructions. Extend end shingle d (See section 5). Existing shingles I Undodoyrmnt No fostmoro within. 5 5/8' 6'of.centedme 131/4" 1 f4' Al Drip edge y Place fig al shingle on me edge k Drip edge theverticalsevere.einches back P 9 Loin valley shingle. and—ring me vertical shingle. New shingles 5 5/8" 55/8'exposure 10.NIP AND HIIDGE FASTMING DETAIL exposure Apply the shingles with a 5 in.exposure beginning at the bottom of the hip or from the end of the ridge opposite the direction of the 9.VALLE APPIaIC(TION prevailing winds.Secure each shingle with one fastener on each side, 5-1/2 in.back from the exposed end and 1 in.up from the edge._ Over the shingle underlayment,center a minimum 361n.wide sheet a shingle of TAMKO Nail-Fast,Moisture Guard Plus"or a minimum 50 Ib.roll TAMKO recommends the use of TAMKO Hi g le products.Where matching,colors are available,it is acceptable& Rid shin o . roofing in the valley:Nail the felt only where necessary to hold it in place and then-only nail the outside edges. use TAMKO's Elite Glass-Seal shingles cut down to 12 in.pieces: IMPORTANT PRIOR TO INSTALLATION WARM SHINGLES TO Fasteners should,be 1/4 in.longer than the one used for shingles PREVENT DAMAGE-WHICH CAN OCCUR WHILE BENDING, IMPORTANT:.PRIOR TO INSTALLATION, CARE NEEDS TO BE SHINGLES TO FORM VALLEY. TAKEN TO PREVENT DAMAGE WHICH CAN:OCCUR WHILE After valley flashing Is In place: BENDING SHINGLE IN COLD WEATHER. • Apply the first-course of shingles along the eaves of one of the Direction of prevailing wind intersecting roof planes and across the valley. Start 5"exposure n Note:For proper flow of water,over the trimmed shingle,always t start applying the shingles on the roof plane that has the lower _- slope or less height. -1/2 r. n ����''�� 5-1/2 • Extend the end shingle at least 12 in.onto the adjoining roof. Start Apply succeeding courses in the same manner,extending them here 5"exposure across:the valley and onto the adjoining roof. • Press the shingles tightly into the valley. THESE ARE THE.MANUFACTURER'S APPLICATION_ • Use normal shingle fastening methods. INSTRUCTIONS FOR THEI ROOFING CONDITIONS DESCRIBED.TAMKO BUILDING;PRODUCTS, INC.ASSUMES Note:No fastener should bewithin 6 in.of the valley centerline, NO RESPONSIBILITY. FOR LEAKS OR OTHER ROOFING and two-fasteneirs shouid.be placed at the end of each shingle DEFECTS RESULTING.FROM FAILURE TO FOLLOW THE crossing the valley. MANUFACTURER_ 'S INSTRUCTIONS. • To the adjoining roof plane,apply one row of shingles vertically facing the:valley and.9 in,back from the valley centerline. Note: For a neater installation, snapa chalkline over the TAMKO®,Moisture Guard Plus®,Nail Fast®,TAM-PRO®and Heritage®are registered trademarks of TAMKO Building Products,Inc. shingles for guidance. Information included in these application instructions was current at time of printing.To • To Complete the valley, apply shingles on the adjoining roof obtain a copy of the most current version of these application instructions,visa us online plane by'positioning the tip of.the first shingle of each row at at tamko.com or call us at 60g-641-4691. the 2 in.point from the centerline.where the edge of the vertical shingle has been applied,covering the vertical shingle. Central District 220 West 4th St., Joplin,MO 64801 800-641=4691 11109 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamko.eom Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216, 800-530-8868 4