Loading...
HomeMy WebLinkAboutProduct Approval I � I I EVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION `26 GA. IMAGE it PANEL' FLORIDA BUILDING CODE 5""' EDITION (20.14) FLORIDA PRODUCT APPROVAL. FL 11560.5-112 ROOFING METAL ROOFING Prepared For: Metal Sales Manufacturing Corporation 545 South .3«' Street, Suite 200 Louisville, KY 40202 Telephone: (502) 855-4300 Fax: (502) 855-4290 I Prepared By: Bala Sockalingam, Ph.D., P.E. Florida Professional Engineer#62240 1216 N Lansing Ave., Suite C Tulsa, OK 74.1.06 Telephone: (918) 492-5992 FAX: (866) 366-1543 This report consists of Evaluation Report (3 Pages including cover) I °`1'rarrrrrr� Installation Details (1 Page) eeeti�°° S0CK,q��®os� No 62240 Report No. 02009-5 �: ;'fi r �^ S TAT E OF ; C[/ Date: 3.27.15 O' .�%% v i FL 11560.5-R2 C2009-5 3.27.15 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation, Product Name: Image 1I Panel Description: Max. 16" wide coverage with 1" high ribs i Materials: Min. 26 ga., 50 ksi steel. Galvanized coated 'steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). I Deck Description: Min. 19/32" plywood for new and existing constructions, Designed and installed as per FBC 2014. Deck Attachment: 8d x 2.5" long ring shank nails or#8 x 2" long wood screws @ 6" o.c. (Minimum) in the plywood field and edges Underlayment: Minimum underlayment as per FBC 2014 Section 1507.4.5.1 Slope: 2:12 or greater in accordance with FBC 2014 Section 1507.4.2 Design Uplift Pressure: 84.25 psf @ fastener spacing of 24" o.c. (Factor of Safety = 2) 102.7 psf @ fastener spacing of 6" o.c. 139.1 psf @ fastener spacing of 6" o.c. with 3/8" bead adhesive in panel sidelap Fastener Pattern: At panel seam #10-12 pancake head screws along panel seam. Fastener shall be of sufficient length to penetrate tlu•ough the deck,a minimum of'/4". Sidelap Adhesive: Schnee-Morehead SM7108 Permathane adhesilve i Test Standards: Roof assembly tested in accordance, with ITAS '125-03 `Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2014 Section 1507.4 Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is ii,ot applicable in High Velocity Hurricane Zone. Refer to current NOA for use of this product in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2014 Section 1505 and current approved roofing materials directory, or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. i I 'I c FL 11560.5-R2 C2009-5 3.27.15 Page 3 of 3 Supporting Documents: TAS 125 Test Reports Farabaugh Engineering and Testing Inc' Project No. T241-07, Reporting Date 7/23/07 Hurricane Test Laboratory, LLC HTL Report #: 0103-0714-09, Reporting Date 9/1/09 I i i DRAWN Bt. NECKED Bv: B.S. D.S. PLOT: DAiE: 3/]5/13 SEE DETAIL 1 —MAX. 16" PANEL FASTENER ROOF PANEL SPACING PER ALLOWABLE PRESSURE TABLE. S u n I I PLYWOOD IL UNDERLAYMENT SHALL BE INSTALLED 8d x 2.5" LONG RING SHANK NAIL_ 19/32" THICK (MIN.) AS PER MANUFACTURER'S INSTALLATION GUIDELINES OR #8 x 2" LONG WOOD SCREWS z MIN. 2X_ WOOD RAFTER/JOIST/ SPACED ® 6" O.C. IN THE FIELD & TRUSS AT MAX. 24" O.C. AT PLYWOOD EDGES FASTENING PATTERN 1 a SEE DETAIL 2 ADHESIVE IN THE MAX. 16" PANEL FASTENER o 0 ROOF PANEL PANEL SIDELAP SPACING PER ALLOWABLE 0 / PRESSURE TABLE. Z uj� 0 ON � Nip kMIN. IIZ oLzU) IL UNDERLAYMENT SHALL BE INSTALLED PLYWOOD � MSIAS PER MANUFACTURER'S INSTALLATION 8d x 2.5" LONG RING SHANK NAIL 19/32" THICK (MIN.)GUIDELINESOR #8 x 2" LONG WOOD SCREWS L'jFD0o 2X_ WOOD RAFTER/JOIST/ SPACED @ 6" O.C. IN THE FIELD & < oo TRUSS AT MAX. 24" O.C. AT PLYWOOD EDGES N `n J FASTENING PATTERN 2 a n TYPICAL PANEL INSTALLATION X-SECTION w a ALLOWABLE UPLIFT PRESSURE w o MIN 26 GA. PANEL ¢ = F *— AT 12 X 1" LONG FASTENING FASTENER ADHESIVE PRESSURE AKE SCREWS PATTERN SPACING BEAD SIZE (PSF) _ DETAIL 1 X. 6" D.C.- - (IN)1 24 NONE 84.25--UNDERLAYMENT -1 6 NONE 102 7 1LYWOOD -- -- - - 19/32" THICK (MIN.) 2 6 3/8" 139.1 i __SIDELAP ADHESIVE - • SIDELAP ADHESIVE IN THE PANEL SIDELAP T NOM. 3/8" BEAD _ MIN 26 GA. PANEL--\ 1 GENERAL NOTES: #10-12 X 1" LONG PANCAKE SCREWS 1.ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE AT MAX. 6" O.C. SIDELAP-ADHESIVE FLORIDA BUILDING CODE (FBC). DETAIL LOCATION 2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.0167"). MAX. EFFECTIVE COVERING WIDTH OF PANEL = 16". 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. UNDERLAYMENT 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING& THE FLORIDA DRAWING No. REV, PLYWOOD BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM 2009_5 19/32" THICK (MIN.) REQUIREMENTS OF THIS DRAWING &THE CODE, THE CODE SHALL CONTROL. 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS PACE N0, REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. 1 OF 1