Loading...
HomeMy WebLinkAboutProduct Approval RECEIVED DEC 2 8 2016 PEWMITfING NIIANII-DADF COUNTY MIAMI•DiADE St. Lucie County, FL PRODUCT CONTROL SECTION 1 1805 SW 26 Strecf- Room 208 DEPARTMENT OF REGULATORY AND F,CONOMIC RESOUR(J,S(RER) Miami,Florida 23175-2171 BOARD AND CODE ADMINISTRATION DIVISION T(790)315-2590 F(78(v)315-2599 NOTICE OF ACCEPTANCE (NOA) GAF 1 Campus Drive Parsippany,NJ 07054 SCOPF,: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Mianli-Dade County RIR - Product C'ont'ol Section to he used in Miami Dade County and other areas where allowed by the Authority Having Jurisdict[oil (Al 1.1). This NOA shall not be valid after the expiration date stated below. The Mianli-Dade County Product Control Section (ill Miami Dade County) and/or the Al (in areas other than Mianli Dade County) reserve the right to have this product or material tested for quality assurance purposes. if this product or material fails to perform in the accepted nrllulcr, the nlanulacturcr will incur the expense of such Testing and the Al H may immediately revolve, modify, or suspend the use of such product or material within their.Iurisdiction. RIR reserves the right to revoke this acceptance, il' it is determined by Miami-Dade County Product Cont•ol Section that this product or material fails to meet the requirements ol'the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including"the I ligh Vclocily 1 lurricanc 'Lone oi'thc Florida Building Code. DF,SC:R1P HON: GAF Timberline 11131Timberline Natural Shadow",and Timberline American Harvest" Shingles LABELING: Faell Unit shall bear a permanent label with the IllallUktaurer's ilanic of lop, city, state and following statement: "Mianli-Dade County Product Control Approved", unless otherwise noted herein. RF.NF,WAL of this NOA shall be considered alter it renewal application has been filed and there has been no change in the applicable building code negatively affecting the Pei-1Ol'lllalice of this product. Ti?RMINATION of'this NOA will occur after the expiration date or if,there has been a revision or change in the materials, use, and/or manufacture ol'the product or process. Misuse of this NOA as an endorsement of anv product, for sales, advertising or any Other purposcs shall automatically terminate this NOA. Failure to comply with any section ol'this NOA shall be cause Im termination and removal ol'NOA. ADVERTISFMF,NT: The NOA number preceded by the words Mianli-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. if any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be Provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 13-0419.04 and consists of pages I through 6. The stlbnlitted dOClllllelllatiOtl was reviewed by Juan E. Collao, R.A. NOA No.: 14-11122.20 MIAMI•DADEGOUNTY Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 1 of 6 ROOFING ASSI?M13Lv APPROVAL Catezory: Rooting Sub-Cateeory: Asphalt Shingles Materials: Laminate Deck Tyne: Wood Scow This approves GAF Timberline HU",Timberline Natural Shadow"',and Timberline American Harvest Shingles as manufactured by GAP as described in Section 2 of this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications GAF Timberline 111)'" 13 Ali.,x 39`l,i TAS 110 Fiberglass reinforced lieavy weight asphalt Muliufac•luring roof shingle, with a laminate profile Locations#1,2,3,4,5,b,7 GAF Timberline Natural 13 '!.i x 39 ;/x TAS 110 Fiberglass reinforced Heavy weight asphalt Shadow"' roof shingle, with a laminate profile Munu/ucluring Loculinus#1,2,3,4,5,6,7 GAF Timberline American 13 '/,i x 39 ,/,i TAS 110 Fiberglass reinforced heavy weight asphalt Hurvest" rool'shingle, with a laminate profile .ALlunujiiCl uriNg Locutions#2,4,5,6 MANUFACTURING LOCATION 1. Tampa, 1'L, 2. Michigan City, IN 3. Baltimore, MD 4. Myerstown, PA 5. Ennis,TX X 6. Tuscaloosa, Al, 7. Dallas, TX MIAMI-DADE NOA No.: 14-1022.20 Srguuaolvl � Expiration Date:02/21/17 Approval Date: 02/05/15 Page 2of6 EVIDENCE;SUBMrrTED Test Ap_ency 'Test Identifier Test Name/Rcnurt Date. Underwriters Laboratories, Inc. ASTM D3462 11 CA48924 10/24/11 Underwriters Laboratories, Inc ASTM D3462 I OCA21994 04/22/11 Underwriters Laboratories, Inc ASTM D3462 1OCA28717 07J26/1 1 Underwriters Laboratories, Ine. ASTM D3462 05CA47541 11/10/06 Underwriters Laboratories, Inc. ASTM D3462 06CA 31580 I I J30/06 PRI Asphalt Technologies, Inc. ASTM D3462 GAF-101-02-02 1 1102105 Underwriters Laboratories. Inc. ASTM D3462 06NK05159 08/09106 PRI Asphalt Technologies, Inc, ASTM D3402 GAF-098-02-02 11/08/05 Underwriters Laboratories, Inc. ASTM D3462 02NK41809 09/11/02 Underwriters Laboratories, Inc. ASTM D3462 03NK26444 10/17/03 Center for Applied I_;nginecring ASTM D3462 257989 05/13/97 Underwriters Laboratories, Inc. TAS 107 OINK45803 04/13/94 Underwriters Laboratories, Inc. TAS 107 06NK05159 08/09/06 Underwriters Laboratories, lnc. TAS 107 04NK0427/3 02/20/04 Underwriters Laboratories, Inc. TAS 107 05CA42840 1 111 1/05 Underwriters Laboratories, Inc. TAS 107 02N K4181 1 11/11/02 Underwriters Laboratories, Inc. TAS 107 03CA35209 10/17/03 Underwriters laboratories, Inc. TAS 107 04CA13850 08/30/04 Center for Applied Enygineering TAS 100 257989 04/01/97 PRI Asphalt Technologies. Inc. TAS 100 GAF-044-02-01 01/13/04 PRI Asphalt Technologies, Inc. TAS 100 GAF-098-02-01 11/08/05 PRI Asphalt Technologics, Inc. TAS 100 GAF-101-02-01 11/09/05 PRI Asphalt'1'eehnologies, Inc. TAS 100 GAF-I 16-02-02 03/23/06 PRI Asphalt Technologies. Inc. TAS-100 ELK-083-02-01 10/16/02 ELK-084-02-01 10/15/02 ELK-085-02-01 10/14/02 ELK-086-02-01 10/24/02 FLK-087-02-01 10/21/02 FI_,K-088-02-0I 10/16/02 FLK-107-02-01 10/09/03 ELK-108-02-01 10/09/03 ELK-109-02-01 10109/03 LIMITATIONS I. Fire classification is not part ofthis acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit ir► accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 14-1022.211 MIAMI•DADECOUNTY Expiration Date: 02/21/17 Approval Datc: 02/05/15 Page 3 of G INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Rooting Application Statldard RAS 115 3. '['lie manufacturer shall provide clearly written application instructions. 4. Exposurc and CUtli'Se layout shall be ill Compliance with Detail 'A', attached. 5. Nailing shall be ill compliance with Detail '13',attached. LABELING Shingles shall bear the imprint or idcntitiable marking of the manufacturer's mune or logo, city and state of manufacturing facility, and following statement: "Miami-Dade County product Control Approved" or the Mianli-Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY ��Fgjmlyjgfj BUILDING PERMITREQUIREMENTS 1. Application foo-building permit shall be accompanied by col)ies ol'thc following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the 131.1ilding Official or the applicable code in order to properly evaluate the installation of this system. MIAMI-l7ApE COUNTY NOA No.: 14-11122.20 gmv ,� Expiration Date: 02/21/17 Approval Date: 02115/15 Pale 4 of b DETAIL A COURSE LAYOUT DECK FULL 5th 17"OFF 4th 11" OFF 3rd 6" OFF 2nd FULL 1 st NOA No.: 14-1022.2!! QMIAM6DADECOU■N Expiration nate: 02/21/17 Approval Data 02/05/15 Pale 5 of b DETAIL B OVERALL DIMENSIONS ANI)NAILING PA'I 1'E.RN 39-3/811 -� (,nt) �— 14-1/2"-17-1/2" 14-1/2"-17-1/2" (368-445mm) (368-445mm) 6-1/2"-9-1/2" �-- 6-1/2"-9-1/2" ail guide line 13-1/4" _j1G5�ldtmml —• — — +— — —♦ — — ♦ E5 741mm1 'l46 - -159 (3a 1n (146mm-159rnm) from bottom of shingle 113.U 7- Self seal adhesive on back ENHANCED NAILING PATTERN - six nails per shingle" required by some meal codes and required for enhanced wind coverage on certain products. See limited warranty for details. These shingles MUST be nailed a nominal 6" (152mm)from bottom of of shingle, above the cut outs, as shown. Nails must not be exposed. END OF THIS ACCEPTANCE NOA No.: 14-1022.20 MIAMI•DADECOUNTY Expiration Date: 02/21/17 ...$ Approval Date: 02/05/I5 Page 6of6