FL* FL183S5-R2
Application Type Revision DEC 2 9 2016
Code Version 2014
Application Status Approved PERMITTING
St. Lucie County,FL
Comments
Archived
Product Manufacturer TAMKO Building Products,Inc.
Address/Phone/Email PO Box 1404
Joplin,MO 64802
(417)624-6644 Ext 2305
kerri—eden@tamko.com
Authorized Signature Kerri Eden
kerri_eden@tamko.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
0 Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R.Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 01/07/2019
Validated By Locke Bowden
' Validation Checklist-Hardcopy Received
Certificate of Independence FL18355 R2 COI TBP15001.2 FBC 2014 Product Evaluation Report
Shin leg_s.pdf
Referenced Standard and Year(of Standard) Standard YAW
ASTM D 3161 2009
ASTM D 3462 2009
ASTMD D 7158 2008
TAS 100 1995
Equivalence of Product Standards
Certified By
Sections from the Code
https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquvosrHazGXQW83... 12/29/2016
Florida Building Cade Online Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 12/16/2015
Date Validated 12/18/2015
Date Pending FBC Approval 12/19/2015
Date Approved 02/10/2016
Summary of Products
FL# Model,Number or Name Description
18355.1 Glass-Seal,Elite Glass-Seal, ASTM D 3462 asphalt shingles and hip and ridge shingles
Heritage,Heritage Premium,
Heritage Woodgate,Heritage
Vintage,Hip and Ridge,and
Vintage Hip and Ridge Shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL18355 R2 jI TBP15001.2 FBC 2014 Product Evaluation
Approved for use outside HVHZ:Yes Reoort Shinales.odf
Impact Resistant:N/A Verified By:Zachary R. Priest PE-74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FI-18355 R2 AE TBP150012 FBC 2014 Product Evaluation
Reoort ShinDles.odf
Created by Independent Third Party:Yes
Back F.—__
Contact Us::7601 Blair Stone Road.Tallahassee FIL 37399 phone:850-487-1824
The State of Florida is an AA/EEO employer.Coovrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address it
they have one.The emails provided may be used for oft ial communication with the licensee.However email addresses are public record.It you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public To determine If you are a licensee under
Chapter 455,F.S.,please click bUL.
Product Approval Accepts:
Credit Card
Safe
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquvosrHazGXQ W 83... 12/29/2016
K Certificate of Authorization No.29814
CREE 17520 Edinburgh Dr
Tampa,FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE 5T"EDITION(2014)
Manufacturer. TAMKO BUILDING PRODUCTS Issued December 14,2015
220 West 4"'Street
Joplin, MO 64801
(417)624-6644
Manufacturing Plants: Joplin, MO
Phillipsburg,KS
Frederick,MD
Dallas,TX
Tuscaloosa,AL
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Asphalt Shingles
Code Sections: 1507.2.5, 1507.2.7.1, 1523.6.5.1
Properties: Physical properties,Wind Resistance,Wind Driven Rain
REFERENCES
Entity Report No. Standard Year
PRI Construction Materials Technologies(TST5878) TAP-043-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-051-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-054-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-114-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-117-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-130-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-131-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-165-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-280-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-303-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-307-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-314-02-01 Rev 2 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)e1
PRI Construction Materials Technologies(TST5878) TAP-317-02-01 TAS 100 1995
UL LLC(TST9628) 02NK9507 ASTM D 3161 2009
UL LLC(TST9628) 04NK24366 ASTM D 3462 2009
UL LLC(TST9628) 05NK28006 ASTM D 6381 2008(2013)e1
UL 2390
ASTM D 7158 2008d
UL LLC(TST9628) 06NK03898 ASTM D 3161 2009
ASTM D 3462 2009
UL LLC(TST9628) 08CA59132 ASTM D 3161 2009
UL LLC(TST9628) 09NK07896 ASTM D 3161 2009
ASTM D 3462 2009
UL LLC(TST9628) 1 OCA50498 ASTM D 3462 2009
UL LLC(TST9628) 1 OCA64882 ASTM D 3161 2009
UL LLC(TST9628) 11NK14014 ASTM D 3161 2009
ASTM D 3462 2009
UL LLC(TST9628) 12CA24551 ASTM D 3161 2009
UL LLC(TST9628) 4786110543 ASTM D 6381 2008(2013)e1
UL LLC(TST9628) 4787043752 ASTM D 3161 2009
UL LLC(TST9628) 4787148748 ASTM D 7158 2008d
ASTM D 3161 2009
ASTM D 3462 2009
TBP15001.2 FL18355-R2 Pagel of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
PRODUCTS
TAMKO BUILDINGAsphalt Shingles
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
Elite GlassSeal4l) 12-1/4"x 36",ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
(Frederick,Joplin& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa) ceramic granules complying with ASTM D 3462.
Glass-Seal 12-1/4"x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
(Frederick& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa) ceramic granules complying with ASTM D 3462,
Glass-Seal 12-1/4"x,36",ASTM D 7158, Class H self-sealing,3-tab asphalt shingle with fiberglass
(Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying
with ASTM D 3462. Shingles shall be used in the non-HVHZ only.
Heritage® 13-14" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas,Frederick, reinforced, laminated architectural asphalt shingle surfaced With mineral granules
Joplin,Phillipsburg& complying with ASTM D 3462.
Tuscaloosa)
Heritage®Premium 13-114" x 39-318", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas,Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Phillipsburg& complying with ASTM D 3462.
Tuscaloosa)
Heritage®Premium 12" x: 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage®Vintage® 17-1/2*x 40",ASTM D 3161, Class F and ASTM D 7158,Class H fiberglass reinforced,
(Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
HerltagelD Woodgate 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas&Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules
complying with ASTM D 3462.
Heritage®Woodgate 12" x: 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural
(Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles
shall be used In the non-HVHZ only.
Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt
(Frederick&Joplin) shingle surfaced with mineral granules complying with ASTM D 3462.
Vintage@ Hip and Ridge 12"x 12",ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle
(Phillipsburg) surfaced with mineral granules complying with ASTM D 3462.
TBP15001-2 FL18355-R2 Page 2 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
DING PRODUCTS
CRTAMKO BUIL
EEK Asphalt Shingles
TECHNICAL SERVICES, LLC
INSTALLATION
Elite Glass-SealO Basic Wind Speed(Vut): Max. 194 mph
(Frederick,Joplin& Basic Wind Speed(V,,d): Max, 150 mph
Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements;
& Solidly sheathed min. 19/32 in. plywood or wood plank for
Glass-Seal new construction; Min. 15/32 in. plywood existing
(Frederick,Joplin(Non- construction.
HVHZ)&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in, plywood or wood plank for
new construction;Min.7/16 in,OSB existing construction.
Undedayment: In accordance with FBC requirements.
Min,slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation(HVHZ): Installed with 5-1/8 inch exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5-1/8-inch exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"4 Nail
Pattem"or"6 Nail Pattem"detailed below.
NAILS
Nalling 6-711f
Arrow
L
Figure 1. Elite Glass-Seal&Glass-Seal
4 Nail Pattern(Non-HVHZ only)
NAILS
Nailing-- 6-7X
Area
Butt Edge
Figure 2. Elite Glass-Seal&Glass-Seal
6 Nail Pattern
TBP15001.2 FL18355-R2 Page 3 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor Imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
TAMKO BUILDING PRODUCTS
CREEK Asphalt Shingles
TECHNICAL SERVICES,LLC
Heritage@ Basic Wind Speed(V At): Max. 194 mph
(Dallas,Frederick,Joplin, Basic Wind Speed(V d): Max. 150 mph
Phillipsburg&Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements;
& Solidly sheathed min. 19/32 in, plywood or wood plank for
Heritage@ Premium new construction; Min. 15132 in. plywood existing
(Dallas,Frederick construction.
Phillipsburg&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements;
& Solidly sheathed min. 15/32 in, plywood or wood plank for
Heritage®Woodgate new construction;Min.7/16 in.OSB existing construction.
(Dallas&Frederick) Undedayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturers application instructions when installing
shingles at slopes greater than 21:12.
Installation(HVHZ): Installed with 5-5/8 in. exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using T Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5-5/8 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"4 Nail
Pattern"or"6 Nail Pattern"detailed below.
FASTENERS NAIL ZONE
COM MON
0/BOND
6-1/$" EXPOSURE 6-6/9'
11L [tll- 12-11211 ► 12-3/8" 12-1/2'"� �-i it
Figure 3. Heritage@, Heritage®Premium,and Heritage®Woodgate(Dallas)
4 Nail Pattern(non-HVHZ only)
FASTENERS NAIL ZONE
/COMMON
BOND
IEXPOSURE 5-518"
Figure 4. HerltageO&HeritageS Premium
6 Nail Pattern
TBP15001.2 FL18355-R2 Page 4 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
CREEK
TAMKO BUILDING PRODUCTS
j Asphalt Shingles
TECHNICAL SERVICES, LLC
NAIL ZONE/
ASTENERS COMMON BOND
6-118" EXPOSURE 5 Sib"
}
1 "1 �7-112+7-112' -31 +-112+-1/29� �—V
Figure 5. Heritage@ Woodgate
i 6 Nail Pattern
-►It^sr + 12.1/2" i F 12-1/2"----►�1^i11�r-
1 1 1 1
M Common Bond
FASTENERS
Lh FL
39-3/8"
Figure 6. Heritage®,Heritage@)Premium,8 Heritage®Woodgate
Alternate 6 Nail Pattern
PAINT
LINE
7-7/8" _ _ L ZONE
6-1/8° EDGE OF
COMMON
BOND
EXPOSURE
ACCEPTABLE
FASTENER LOCATION
DO NOT FASTEN
-- - COMMOEDGE
BOND
AK
PREFERRED
FASTENER
LOCATION
Figure 7. Heritage®(Tuscaloosa)
Expanded Nail Zone
Nail patterns from Figures 3,4,and 6 may be placed in the nail zone as described above
TBP15001.2 FL18355-R2 Page 5 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20.3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES,LLC
Heritage®Premium Basic Wind Speed(Vwt): Max.194 mph
(Frederick) Basic Wind Speed(Vd): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction;Min.7/16 in.OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12. .
Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"4 Nail
Pattem"or"6 Nail Pattern"detailed below.
NAIL ZONE/
FASTENERS COMMON BOND
S1/2" EXPOSURE 5"
1 u--►) �1- 11"-►�-- 1211 -r�---11"--►( �-1"
Figure& Heritage®Premium(Frederick)
4 Nail Pattern (non-HVHZ only)
NAIL ZONE/
FASTENERS COMMON BOND
51/2" EXPOSURE 5"
'I {� Figure 9. Heritage@ Premium(Frederick)
6 Nail Pattern
TBP15001.2 FL18355-R2 Page 6 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES,LLC
Heritage®Woodgate Basic Wind Speed(Vu,): Max. 194 mph
(Frederick) Basic Wind Speed(V�d): Max. 150 mph
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction;Min.7/16 in.OSB existing construction.
Underiayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"4 Nail
Pattern"or"6 Nail Pattern"detailed below.
NAIL ZONE/
FASTENERS COMMON 80ND
T
5.112" EXPOSURE 5'
12-3/81F—I►�- i1" —I �-i"
Figure 10. Heritage®Woodgate(Frederick)
4 Nail Pattern(non-HVHZ only)
NAIL ZONE/
COMMON BOND
FASTENERS
1
5.112" EXPOSURE 5"
}
9-112"�-41+-9-I*3+9-W,-I �11-1"
Figure 11. Heritage®Woodgate(Frederick)
6 Nail Pattern
TBP15001.2 FL18355-R2 Page 7 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
GREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
Heritage®Vintage® Basic Wind Speed(Vut): Max. 194 mph
(Phillipsburg) Basic Wind Speed(Vwd): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction;Min.7/16 in.OSB existing construction.
Undedayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either'5 Nail
Pattern"or T Nail Pattern"detailed below.
N
Y � rxpowe
Poach
r It
b„ Famnes Nail
ore
- - — — — — — — — — — i - - - -
r7-ial,
S-1
rxpwule
1
Figure 12. Heritage®Vintage®
5 Nail Pattern(non-HVHZ only)
+r
rmw+
Nmome Plots
au+.
n-trr
s
i
b* 7- 0-�►-''"'-'�'
Figure 13. Heritage@ Vintage'
6 Nail Pattern
TBP15001.2 FL18355-R2 Page 8 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
G R E K TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
Hip&Ridge Basic Wind Speed(Vet): Max. 194 mph
(Frederick&Joplin) Basic Wind Speed(V w): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min.7/16 in.OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements.
Installation: Installed with 5-1/8 inch exposure in accordance with the
FBC and manufacturer's published installation instructions.
The direction of the exposed end shall be away from the
prevailing wind.
Direction prevailing wind
g� H 1/8" exposure
here
_ .I II t
star
Figure 1 here 5-1/8"exposure
A 1„
6, W\ Figure
Fastenerstener
"3
Figure 2 1\4"
Figure 14. Hip&Ridge(Frederick&Joplin)
TBP15001.2 FL18355-R2 Page 9 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
CREEK
TAMKO BUILDING PRODUCTS
R L Asphalt Shingles
TECHNICAL SERVICES, LLC
Vintage®Hip&Ridge Basic Wind Speed(Vut): Max. 194 mph
(Phillipsburg) Basic Wind Speed(V�e): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction;Min.7/16 in.OSB existing construction.
Undedayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements.
Installation: Installed with 5 inch exposure in accordance with the FBC
and manufacturer's published installation instructions. The
direction of the exposed end shall be away from the
prevailing wind.
Direcdo�n of prevailing wind
01art 5" exposure
ere~
•1
start
here 5" exposure
Figure 1
1"
FastenerFastenor
t ` 5-1/2"
Figure 2 4 Figure 3
Figure 15. Vintage®Hip&Ridge (Phillipsburg)
TBP15001.2 FI-18355-R2 Page 10 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ.
4) Classification to ASTM D 7158 applies to exposure B&C with a building mean roof height of 33-ft or less.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the
deck.
7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and code compliant detail shall prevail.
8) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 5Edition(2014)as evidenced in the referenced documents submitted by the named manufacturer.
01111111111111i,11
11 'R.PA 4i
......... 9, 2 015.12.14
ti�:• •'' '' 13:44:19
No 74021
- -05'00'
: P% STATE OF '•4tJ
i A' .* Zachary`���` Zachary R.Priest,P.E.
Florida Registration No.74021
E �%% Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E.does not have, nor will acquire,a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved In the approval process of the
product.
END OF REPORT
TBP15001.2 FL18355-R2 Page 11 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.