HomeMy WebLinkAboutProduct Approval (2) EVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION `26 GA. 5V-CRIMP PANEL' FLORIDA BUILDING CODE 5TH EDITION (2014) FLORIDA PRODUCT APPROVAL FL 19902.1 ROOFING METAL ROOFING Prepared For: Metal Sales Manufacturing Corporation 545 South 3rd Street,Suite 200 Louisville,KY 40202 Telephone: (502) 855-4300 Fax: (502) 855-4290 Prepared By: Bala Sockalingam,Ph.D.,P.E. Florida Professional Engineer#62240 1216 N Lansing Ave.,Suite C Tulsa, OK 74106 Telephone: (918)492-5992 FAX: (918)493-3568 This report consists of Evaluation Report(3 Pages including cover) Installation Details (1 Page) o a®%ee0GKALIf ®i� Load Span Table(1 Page) e,®oS,G�N SF sv e ra No 62240 CC W F :LU- ReportNo. 02076-1 ='o•: gTA�E �,.;2� Date: 2.13.16 �'. 0�. p R --- � f FL 19902.1 C2076-1 2.13.16 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: 5V-Crimp Panel Description: 24" wide coverage with(5) 1/2" high ribs Materials: in. 26 , 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel(ASTM A792) or painted steel(ASTM A755). Deck Description: 7/ 6 thic OO SB or mm 15/32" thick plywood at max span of 24" for new and existing constructions. Designed and installed as per FBC 2014. Deck Attachment: 8d x 2.5" long ring shank nails or#8 x 2" long wood screws @ 6" o.c. (Minimum) in the plywood field and edges Underlayment: Minimum underlayment as per FBC 2014 Section 1507.4.5.1 Slope: 1/2:12 or greater in accordance with FBC 2014 Section 1507.4.2. Design Uplift Pressure: 30.0 psf @ fastener spacing of 36" o.c. (Factor of Safety=2) 172.5 psf @ fastener spacing of 6" o.c. Fastener Pattern: Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8" and installed as per Metal Sales current'installation procedure. At panel ends @ 6" o.c. across panel width At intermediate @ 12" o.c. across panel width Test Standards: Roof assembly tested in accordance with UL580-06 `Uplift Resistance of Roof Assemblies' & UL1897-04 `Uplift Tests for Roof Covering Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2014 Section 1507.4 Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. The design pressure for reduced fastener spacing may be computed using rational analysis prepared by a Florida Professional Engineer or based on Metal Sales load span table. This evaluation report is not applicable in High Velocity Hurricane Zone.Fire classification is not within scope of this Evaluation Report. Refer to FBC 2014 Section -' FL 19902.1 C2076-1 2.13.16 Page 3 of 3 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: UL580& 1897 Test Reports PRI Construction Materials Technologies MSMC-017-02-01,Reporting Date 9/20/13 PANEL OVERLAP 5V-CRIMP SEE DETAIL 2 / SEE DETAIL 1 REQUIRED FOR PANE FASTE ER AT PANEL FLAT ENDS ONLY. $ VI ii Lv / FASTENER SPACING AS PER MINIMUM ATTACHMENT: o DESIGN UPLIFT LOAD TABLE � UNDERLAYMENT SHALL BE INSTALLED 6d 2.5'LONG RING SHANK NAIL OR x x x 2'LONG WOOD SCREWS p AS PER MANUFACTURER'S INSTALLATION SPACED®6'O.C.IN THE FIELD GUIDELINES &AT EDGES MIN. 2X_WOOD RAFTER/JOIST/ a TRUSS AT MAX. 24"O.C. M o V TYPICAL PANEL INSTALLATION X—SECTION " Z�o NOO rl 'y a #9-16 OR#10-14 WOODSCREWS WITH SELF SEALING WASHER AT o MAXIMUM SPACING OF 36'O.C. No 5V-CRIMP ==n MIN 26 GA s S� ai a GENERAL NOTES: �' d 1.ARCHITECTURAL ROOF PANE HAS BEEN DESIGNED IN ACCORDANCE WITH THE o UNOERLAYMENT FLORIDA BUILDING CODE(FBC). n a Nmm OSB 7/16'THICK(MIN.)OR 2.ROOF PANELS SHALL BE MIN. 26 GA (t=0.019').EFFECTIVE COVERING ^ DETAIL 1 PLYWOOD 15/32'THICK(MIN.) WIDTH OF PANEL= 24'. v zo 3.THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING&STRUCTURE AS SPECIFIED ON THIS DRAWING. 4.REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS #9-16 OR 810-14 WOODSCREWS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS »� WITH SELF SEALING WASHER AT ARE GREATER THAN THE DESIGN UPLIFT PRESSURES SPECIFIED ON THIS DRAWING. 3y ti MAXIMUM SPACING OF 36'O.C. 5.ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING&THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM U REQUIREMENTS OF THIS DRAWING&THE CODE.THE CODE SHALL CONTROL SV-CRIMP 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS MIN RI GA REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. UNDERLAYMENT OSB 7/16'THICK (MIN.)OR 1 2076-1 DETAIL 2 PLYWOOD 15/32'THICK (MIN.) O Jai • METAL SALES MANUFACTURING CORPORATION 26 GA.5V-CRIMP PANEL Design Uplift Loads Description Fastener Spacing Allowable Uplift along panel length Load (in) (psfl 5V-Crimp Panel 6 172.5 Min. 26 ga. -- ---- 9 -- — 120.0 - ---- - 12 _ 90.0 Panel Fasteners 15 _ 72.0 #9-16 or#10-14 hex head 18 60_.0 wood screws with sealed _ 21 _ 51.4 washer 24 45.0 27 _ -- 40.0 30 _ 36.0 _ 33 32.7 36 30.0 Notes: 1. The bold numbers indicate design loads calculated from test data with safety factor of 2. 2. Panels must be installed as per Evaluation Report FL 19902.1 and Metal Sales current installation procedure. 0CKAL/jV % N ° i . �. �. s �. No 82240 :.k Luz -� •, STATE of •lij .��p�• •�C O R`Q•••�oe 1216 N Lansing Ave.,Suite C r����e�i®®oBala Sockalin=am,Ph.D.,P.E. Tulsa,Ok 74106 2, 13 201 (, FL 62240 918 492 5992