HomeMy WebLinkAboutNotice of Acceptance i
i
NIIAMI-DADS COUNTY
MIAMI•DADE), '..) PRODUCT CONTROL SECTION
�`{+'•�,L[j„ ', ' I 11805 SW 26 Street- Room 209
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami.Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786,)315-2599
NOTICE OF ACCEPTANCE (NOA) �„�.�Illla,ldc. ,�r�crum,on
GAF
I Campus Drive
Parsippany,NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the,use ol'c6ilstruction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to lie
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AH.I).
This NOA.sliall not be valid after the expiration date stated below. The Mianii-Dade County Product Control
Section (in Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the tight to
have this product or material tested for quality assurance purposes. if this product or material Fails to perform in
the accepted manner, the manufacturer will incur• the expense of such testing and thel'Al-1J may immediately
revolve, modify, or Suspend the Use Or Such product or material within their.jurisdiction. OR reserves the right to
revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity i-iurricane Zone of the Florida Building Code. j
DESCRIPTION' Quberline TW"',Timberline Natural Shadow01,and Timberline American Mai-vest""
Shingles
LABELING: Each unit sllall bear a permanent label with the manufacturer's llallle or logo, city,state and following
statement: "Mianli-Dade County Produet Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has beeil filed abd there has beets no change
in the applicable building code negatively affecting the performance of this product. 11
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change ill the
materials, use, and/or manufacture of Lhe product or process. Misuse of this NOA,as an ctidorsenient orally product,
for sales,adverlising Orally other purposes shall automatically terminate this NOA. Failui-e to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade"County,1 Florida, and followed by the
expiration date may be displayed in advertising literature. if any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the_job site at the request of the Building Official.
This NOA revises NOA 13-0419.04 and consists of pages I through 6. i
The submitted documentation was reviewed by Juan E. Collao, R.A.
NOA No.: 14-1022.20
MIAMI-DADE COUNTYM Expiration Date: 02/21/17
Approval Date: 02/05/15
Page I of 6
'I '
i
r
,I
i
i
ROOFING,ASSEMBLY APPROVAL
Category, Roofing
Sub-Categot-y: Asphalt Shingles
Materials: Laminate
Deck Tyne: Wood
SCOPE
This approves GAF Timberline I-IWL,Timberline Natural Shadow",and Timberline AnicHean Harvest"'
Shingles as manufactured by GAF as described in Section 2 of this Notice of Acceptance,
PRODUCT DuSCRIPTION J
i
Product Dimensions Test Product Description
Specifications
AES 'tn'pit nc IID 13 /,, 39'/K TAS 110 Fiberglass reinforced heavy weight asphalt
a►n{farclul'ing roof shingle,with a laminate profiiic
Locations#1,2,3,4,5,6,7
,i
GAF Timberline Natural 13 /,► x 39'/8• TAS 110 Fiberglass reinforced heavy weight asphalt
Shadow'"' roof shingle,witll a laminate profile
Marnnfcrclnl•ing
Locations#1,2,3,4,5,6,7 I
GAF Timberline American 13 /,► Y 39'/8' TAS 110 Fiberglass reinfrced heavy weight asphalt
Harvest'i roof shingle,with a laminate profile
ti!l[llll fC1CI10'71t(,'
Locations#2,4,5,6
MANUFACTURING LOCATION i
1. Tampa, FL
2. Michigan City, IN
3. Baltimore, MD
4. Myerstown, PA
5. Ennis,'f X
6. Tuscaloosa,AL j
7. Dallas,TX
�I
i
i
I
j.
I
NOA No.: 14-1022.20
MIAMIDADE CO
UNTY0 ! Expiration Date: 02/21/17
Approval Date:02/05/15
Page 2 of 6
iC
i`
EVIDENCE SUBMITTED
Test Agency Test Identifier- Test Name/Report Date
Underwriters Laboratories, Inc. ASTM D3462 1 ICAOTi24 10/24/11
Underwriters Laboratories, Inc ASTM D3462 I.00A2104 04/22/11
Underwriters Laboratories, Inc ASTM D3462 I OCA28717 07/26/11
Underwriters Laboratories, Inc. ASTM D3462 0'5CA47541 11/10/06
Underwriters Laboratories, Inc. ASTM D3462 06C.A31580 11/30/06
PRI Asphalt Technologies, Inc. ASTM D3462 GAF-101-02-02 11/02/05
Underwriters Laboratories, Inc. ASTM D3462 06NK05159 08/09/06
PRI Asphalt.Technologies, Inc. ASTM D3462 GAF-098-02-02 11/08/05
Underwriters Laboratories, Inc. ASTM D3462 02NK41909 08/11/02
Underwriters Laboratories, Inc. ASTM D3462 03N.K26444 10/17/03
Ccntcr for Applied Engineering ASTM D3462 257989 05/13/97
Underwriters Laboratories, Inc. TAS 107 O1NK45,803 04/13/94
Underwriters Laboratories, Inc. TAS 107 06NK05;159 08/09/06
Underwriters Laboratories, Inc. TAS 107 04NK04273 02/20/04
Underwriters Laboratories, Inc. "TAS 107 '05CA4?940 1 1/1 1/05
Underwriters Laboratories, Inc. TAS 107 02NK41181 1 1 1/1 1/02
Underwriters Laboratories, Inc. TAS 107 03CA35209 10/17/03
Underwriters Laboratories, Inc. TAS 107 04CA 13850 08/30/04
Center Ior Applied Engineering TAS 100 257989 04!01/97
PRI Asphalt Technologies, Inc. 'IAS 100 GAF-044702-01 01/13/04
PRI Asphalt Technologies, Inc,, TAS 100 GAF-098-02-01 11/08/05
I'RI Asphalt Technologies, Inc. TAS 100 GAF-101 002-01 11/09/05
PRI Asphalt'Technologies, Inc. TAS 100 GAF-I 16 02-02 03/23/06
P111 Asphalt Technologies, Inc. 'TAS-100 ELK-083=02-01 10!16/02
ELK-0841 02-01 10115/02
ELK-085;-02-01 10/14/02
ELIC-086-02-01 10/24/02
EL,K-087,-02-01 10/21/02
ELK-088-02-01 10/16/02
ELK-107-02-01 10/09/03
ELK-108-02-01 10/09/03
ELK-109-02-01 10/09/03
LIMITATIONS
i
I. Fire; classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof nlcan heights in excess of 33 ft.
3. All products listed herein shall have a duality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
i
NOA No.: f4-1022.20
MIAMIpA®uNrr Expiration Date: 02/21/17
� t
Approval Date: 02/05/15
Page 3 of 6
i
' I
i
I
INSTALLATION
1. Shingles shall be installed in compliance with Rooting Application Standard RAS ,I, 15.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The;manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail 'A', attached. �
5. Nailing shall be in compliance with Detail '13', attached.
J
LABELING
Shingles shall bear the imprint or identifiable marking of' the manufacturer's name„or logo, city and state of
manufacturing filcility, and following statement: "Miami-Dade County Product Control Aj!proved” or the Miami-Dade
County Product Control Seal as shown below.
QIAMI-DADE COUNTY
'0 D
BUILDING PERMIT REQUIREMENTS J'
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance. 1
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
i
j
l
i
NOA No.: 14-1022.20
MIAMI-DADE COUNTY1111111Expiration Date: 02/21/17
Approval Date: 02/05/15
Page 4 of
I
I
,i
i
i
DETAIL A
COURSE LAYOUT
DECK
j
FULL
I
5th
17" OFF 4th
i
I
11" OFF 3rd
6" OFF 2nd
FULL 1 st
I
i
I
i
NOA No.: 14-1022.20
QMIAMM•DADECOUNTY Expiration Date: 02/21/17
Approval Date: 02/05/15
Page 5 ot•G
J,
DETAIL B j
OVERALL DIMENSIONS AND NAILING PATTERN
i
i
i
39-3/8"
(IM)
I�
�— 14-1(36-46mm) " 14-1/2 -45mm) '
(368-445mm) (368-AASmm) ail guide line
6-1l2"-9-1/?_" Imo— 6-1/2" ' 9-1l2"
�� pcs-zam,m) oes-sa1mm1 5-314"-6-114"
13-1 /4 (146mm-159mm)
(337mm) 1�- z vz° —S -0— �- ®-- from bottom of Shingle
7,
119.64
Self seal
adhesive
on back
ENHANCED NAILING PATTERN - six nails per shingle*
required by some local codes and required for enhanced wind coverage on certain products.
See limited warranty for details.
These shingles MUST be nailed a nominal 6" (152mm)from bottom of
of shingle, above the cut outs, as shown. Nails must not be exposed.
i,
j
END OF THIS ACCEPTANCE
I
,I
I
i
i�
i
! i!
i,
I'
i
i
NOA No.: 14-1022.20
MIAMI•DADECOUNTYM Expiration Dale: 02/21/17
Approval Date: 02/05/15
Pale G ol'G
I
j
1
i
Flor-ida_B.uilding_Code_Online_ _---P_age_1_of 2
i
sr _ -'...m'.r.l" Tt.�-�-n-s-�a•�-- r,--t-� � r. � -mp ��,e� � — ,,n+—�+ a
a
4��7 i 3 �,r i e...�..uv l �'..-.�.:..... :k 1i �.� '�T .•r�ay/�!�t!r+yq��gp- �p?�^�,
..t,...aiu:i::�iv�a_.�,�..s:sPr'.,.�.e.uih:iL r.Gam.,«.�.i«�.'ash11.�.Y.a....•�a:.i I .AiimilAiiwS%Jr`S•`ir ''dd�'Id�3�.:kit�
Florida Denartrrentq Bcls Home Log In✓ User Registration Hot Topics Submit Surcharge Stas&Facts Publications FBG Staff BCIS Site Map Links Search
Busines ���
goProduct Approval
Professi nlalUSER:Public User
!
Regulation 1-
Product Approval Menu>Product or Aoolication Search>Application List>Application Detail
` YO FL# FL11602-R3
Application Type Revision cam,
Code Version 2014
Application Status Approved
Comments
Archived j
Product Manufacturer InterWrap,Inc.
Address/Phone/Email 32923 Mission Way
Mission,NON-US 00000
(551) 574-2939
mtupas@interwrap.com
Authorized Signature Eduardo Lozano
elozano@interwrap.com
I
1
Technical Representative Eduardo Lozano
Address/Phone/Email 32923 Mission Way
Mission,NON-US 00000
(778)945-2891
elozano@interwrap.com !
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
r
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer I'
�l Evaluation Report-Hardcopy Received
I
Florida Engineer or Architect Name who developed Robert Nleminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity Intertek Testing Services NA Inc. ETL/Warndck Hersey
Quality Assurance Contract Expiration Date 11/19/2016
I'
Validated By -lohn W.Knezevich, PE
A Validation Checklist-Hardcopy Received
I.
i
Certificate of Independence FL11602 R3 COI 2015 61 COI Nieminen.odF
Referenced Standard and Year(of Standard)
I
1,
Equivalence of Product Standards
Certified By
I
Sections from the Code
1507.2.3
1507.2.4
1507.2.8
1507.2.9.2
1507.3.3
1507.4.5.1
i
'i
http://www.floridabui lding.org/pr/pr_app_dtl.aspx?param=wGBVXQwtDgsOFc5K%2fTr... 1/18/2016
I '