HomeMy WebLinkAboutNotice of Acceptance i
MIAMI-DADE COUNTY
MIAMimbE) i PRODUCT CONTROL SECTION
11905.1.)M 26 Street_ Boum 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami.Florida 33175-247,1
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NO'T'ICE OF ACCEPTANCE (NOA) ' Nv%V%v.miamidadc."i.0crooumv
GAF
1 Campus Drive
Parsippany,NJ 07054 �
p I �
SCOPE:
This NOA is being issued under the applicable rules and regulations governing theluse of'consh•uction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County iRER -Pr'oduct Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Flavin g Jurisdiction (AI-l.l).
This NOA shall not be valid after the expiration date stated below. The Mialnii-Dade County Product Control
Section (In Miami Dade County) and/or the AI-IJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense Of such testing 'and the Al-IJ may immediately
revoke, Modify, or suspend the use of'such product or material within their jurisdi I ction. RER reserves the right to
revoke this acceptance, if' it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the Fligh Velocity Hurricane Zone of the Florida Building Code.
®h,SC1tI1'TION: ('AF l inrbc=l ne,i_ID" Timberline Natural Shadow",and Timberline American Harvest
` yy
Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city,slate and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted hercul.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
i
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufttetut•e of the product or process. Misuse of this NOA as an endorsement of any product.,
for sales, adver(ising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade JCotmty,�,Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the ritanufaeturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA 13-0419.04 and consists of pages I through 6.
The submitted documentation was reviewed by Juan E. Collao, R.A. .
I NOA No.: 14-1022.20
MIAMI-DAD,COUNTYC 1 Expiration Date: 02/21/17 Approval Date: 02/05/15
Page I o1`6
i,
I
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Catef;ory: Asphalt Shingles
Materials: Laminate
Deck Type: Wood
I
SCOPE
This approves GAF Timberline HD`s',Timberline Natural Shadow'W', and Timberline American HarvestO"
Shingles as manufactured by GAF as described in Section 2 of this Notice or Aece'ptance,
PRODUCT DESCRIPTION
Product Dimensions Test j Product Description
Specifications i
G'�f�fimberline HD'' 13 /,i x 39 /y TAS 110 Fiberglass reinforced heavy weight asphalt
Mauufacluring roof shingle, with a laminate profile
Locations#1,2,3,4,5,6,7
GAF Timberline Natural 13 x 34'/K TAS 110 Fiberglass reinroiced heavy weight asphalt
Shadow" roof shin Igle,widi a laminate profile
Matt nfacturing '
Locations#I,2,3,4,5,(,7
I
GAF Timberline American 13 39'/H• TAS 110 Fiberglass reini'orced heavy weight asphalt
Harvest`' roorshir,gle, witli a laminate profile
,�tutttrfitct wring
Locations#2,4,5,6
MANUFACTURING LOCATION
L Tampa, FL
2. Michigan City, IN
3. Baltimore, MD {
4. Myerstown, PA
5. Omnis,'rx ;
6. Tuscaloosa,AL
7. Dallas,TX
4i
(�I
® i � NOANo.: 14-1022.20
Mr Mr•aao+eouNn� Expiration Date: 02/21/17
Approval Date: 02/05/15
Page 2 of 6
I
EVIDENCE SUBMITTED �
Test Ageney Test Identifier Test Namc/Reyort Date
Underwriters Laboratories, Inc. ASTM D3462 1'ICA48924 10/24/11
Underwriters Laboratories, Inc ASTM D3462 1,0CA21994 04/22/11
Underwriters Laboratories, Inc ASTM D3462 110CA287�17 07/26/11
Underwriters Laboratories, Inc. ASTM D3462 05CA47541 11/10/06
Underwriters Laboratories, Inc. ASTM D3462 06CA31580 11/30/06
PRI Asphalt'Technologics, file. ASTM D3462 GAF-101-02-02 11/02/05
Underwriters Laboratories, Inc. ASTM D3462 06NK05159 08/09/06
PRI Asphalt Technologies, Inc. ASTM D3462 GA1F-098-t12- 02 11/08/05
Underwriters Laboratories, Inc. ASTM D3462 02N K41,909 08/11/02
Underwriters Laboratories, tile. ASTM D3462 03NK26444 10/17/03
Center for Applied Engineering ASTM D3462 ' 2579$9 05/13/97
Underwriters Laboratories, Inc. TAS 107 OINK45i303 04/13/94
Underwriters Laboratories, Isle. IAS 107 66NK05'159 08/09/06
Underwriters Laboratories, Inc. TAS 10704NK04273 02/20/04
Underwriters Laboratories, Inc. TAS 107 05CA42�40 1 1/1 1/05
Underwriters Laboratories, Inc. TAS 107 02NK-41181 1 1 1/1 1/02
Underwriters Laboratories,Inc. TAS 107 ,03CA35;209 10/17/03
Underwriters Laboratories, Inc. TAS 107 04CA13,850 08/30/04
Center for Applied Engineering TAS 100 i 257989 04J01J97
PRI Asphalt Technologies, file. TAS 100 GAF-044-02-01 01/13/04
PRI Asphalt Technologies, Inc. TAS 100 GAF-098'02-01 11/08/05
PRI Asphalt Technologies, Inc. TAS 100 GAF-101 '02-01 11/09/05
PRI Asphalt Teclino logics, Inc. TAS 100 GAF-1 16--02-02 03/23106
PRI Asphalt Technologies, Ine. TAS-100 'LIC-083x02-01 10116/02
ELK-084=02-01 10/15/02
ELK-0851-02-0 I 10/14/02
ELK-086-02-01 10/24/02
ELK-087-02-01 10/21/02
ELK-088-02-01 10/16/02
ELK-107',02-01 10/09/03
ELK-108,'-02-01 10/09/03
ELK-109-02-01 10/09!03
LIMITATIONS
i
i. Fire classification is not part of this acceptance•, refer to a current Approved Roofing Materials Directory for
fire ratings of this product. i
2. Shall not be installed on rool'rnean heights in excess of 33 ft. ;'
3. All products listed herein shall have a quality assurance audit in accolydance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
i.
I
MIAMI•DADE =NTr
NOA No.: 14-1022.20
• • Expiration Date: 02/21/17
Approval Date: 02/05/15
Page 3 of 6
i
I, -
I
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Stanch jd RAS 1 15.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail W, attached. I'
5. Nailing shall be in compliance with Detail '13',attached.
LABELING
Shingles shall bear the imprint or identifiable marking of' the manufacturer"s name,jor logo, city and state of
manufacturing facility, and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade
i
County Product Control Seal as shown below.
j;
MIAMI•DADE COUNTY
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following: I.,
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the i pplicable code in order to properly
evaluate the installation of this system.
I"
i
i
i
I
l
i I
I �
i
NOA No.: 14-1022.20
MIAMI•DADECOUNTY I Expiration Date: 02/21/17
F-1192UN 41A
Approval Date: 02/05/15
Page 4 of G
II
I �
DETAIL A
COURSE LAYOUT �
I,
I
I ,
I
DECK
i
� I
i,
FULL
5th
i,
I
17" OFF 4th j
i
11" OFF 3rd
I
6" OFF 2nd
I
i.
FULL i 1st
I I�
,I
i
�I
I
NOA No.: 14-1022.20
MIAMI•DADECOUNTY Expiration Date: 02/21/17
Approval Date: 02/05/15
Page 5 of 6
I,
I�
L
DETAIL B
OVERALL.DIMENSIONS AND NAILING PA'TjTERN j
�-� 39-3/3" 1 j
(IM) ('
we 14-1/2"-17-1/2" 14-912"-17-1/2" —ro
(368-445mm) (368 445mm) I ail guide line
6-1/2"-9-1/2" �-a 6-1/2"-9-1/2"
13-1/4'
1165-W—) p65•'241mmI 5-314"-6-1/4"
(3371nm) (146mm-159mm)
from bottom of shingle
tta.as '
I, e!f seal
adhesive
on back
it
ENHANCED NAILING PATTERN - six nails per shingle* '.
required by some local codes and required for enhanced wind coverage on certain products. i
See limited warranty for details.
These shingles MUST be nailed a nominal 6"(152mm)from bottom of
of shingle, above the cut outs, as shown. Nails must not be exposed'.
i'
END Off+ THIS ACCEPTANCEI i
'1
j. NOA No.: 14-1022.20
MIAMI-DAD�ECOUN— I� Exph-ation Date: 02/21/17
Approval Date: 02/0.5/15
I
Page 6of6
is