Loading...
HomeMy WebLinkAboutWind Load Calculation RECEI',":-D AN 117017 Company: The Home Depot At Home Services Job Description: Windows/Door Prepared By: Amber Client Name:,Hughart Project Number: 9756350 Version 10.0' - -.�-t 12Str'`stores`oferi%tional}C�;s ,x.v�a-,".`"-,. '".„�, �:'' .w �'�'� ����; •.: _ ,v,U Con wtth ASCE 7-10 ,M,.( forms DESIGN PRESSURES FOR WALL COMPONENTS&CLADDING Design Data Building Data Wind Velocity(mph) 160 y�o-1 P1 Mean Roof Height 12 Risk Category 2 IL + Building Width(ft) 34 Exposure Category C Building Length(ft) 36 Directionality Factor 0.85 Roof Slope (x:12) 4 Internal Pressure Coefficient+/- 0.18 Design pressures listed below are: Allowable Stress OPENING OPENING LOCATION OPENING OPENING DIMENSIONS MAXIMUM POSITIVE MAXIMUM NEGATIVE MARK DESCRIPTION ZONE ELEVATION WIDTH(INCHES) HEIGHT(INCHES) PERSSURE(PSF) PRESSURE(PSF) 1 5500-SH 5 5 25 38 33.5 -44.8 2 5500-1PNL 5 5 36 38 33.5 -44.8 3 5500-1PNL 5 5 52 50 32.2 -42.3 4 5500-1PNL 5 5 36 37 33.5 -44.8 5 5400-PD 5 0 72 80 30.5 -38.8 6 5500-1PNL 5 5 36 37 33.5 -44.8 7 5500-1PNL 5 5 52 50 32.2 -42.3 8 5400-1PNL 5 5 35 24 33.5 -44.8 9 5400-1PNL 5 5 36 24 33.5 -44.8 10 5500-1PNL 5 5 52 50 32.2 -42.3 11 5500-1PNL 5 5 73 37 32.1 -42.1 Width of End Zone(a)in feet= 3.4 5 h 5 a " Y i s s (WA STRUCTURES iNTERNATtOHAL,LLC :.:PAV44r4 sib sc�to�x pimWe.^m 1/4/2017 10:51 AM PYSTO E, W $HEFT. nNon-Impact, r plywood for storm ' P -protection Impact Glass 'F W; Impact Glass , . }. • ,. .• 1 •_.: •"� r • ,. p:. q !-' # It-'. , M` ';p a P 6 Impact Glass •. a ! Y ! ! 9 !'3 !. Impact Glass P y,. i f '..F' '.i. ♦ .: r i.. a 1. .it i. �'; ,. 'u a:: { L q ,, { P 4 ) R.i ':i�' '.,� 1 Non-Impact, �s r plywood for storm yL. r • m' f , r r' 7 - -'". f.';9. ! protection F., Nori'-Impact, plywood for storm R. h protection LOS Impact Glass R n ! ! ' ct Glass Impa On , .,.-! Y::.Iw i:- n i 'n.,.' r.:'�d .,• r , ��•. t e, . { .� P ...' • et M A. •. n. ,.amu. :P .,.p .. • :a, ...,a: •:, u. m: ,• ' ,; ,. f 9`...f L P P q Impact Glass % ! HRJS LLC,#9756350 7606 Deland Ave „:.Ft eri` u�l ue cl frti afir a a� nl�r� tie I w tale "Ce! i "dig� a mint 6e,'� prtF ,daa�r"i�r+ a � .. Impact Glass Fort Pierce, FL 34951 y Replacing 10 windows (8 impact and 2on impact d 1 non-impact door n _ ,. }. ,. ., size for size. �._. . . UP Homeowner has plywood for storm �a' o�a�l lg T66f a+q d? r z ust ata7d protection. I�RR�IIIIU llIU lI,ml�l�lP!!!Ulq,� _ The cost of the job is 28% of the � ? n9,9�91?II9 , tai di t ; � loi i�r Tdal' ;.Lin E�. structures assessed value. WINDOW SPECIFICATION SHEET - Spec.Sheet#: 9756350 Sheet: 1 of 2 Customer: Ronald Hughart Job#: 9756350 Consultant: STACY A DEANGELO Date: 01/02/2017 New Window Existing Window Hinge Locations Measurements Grids Product Options Labor Options From outside, Left to Right Bays,Bowls Location Color Rough Opening #of bars #of bars Csmnts,1 Pnl, use L,R or S Glass Misc Items Hardware Code Screens For doors use c c Mull "S"=stationary or " 6 c7 to W ` c ' c "X"=operating Style Wraps � N L— Room Floor Code (Y/N) Style Code Series Code 5 w _ D F C v a > i > z STD,GlassPack:Standard LSR 1 Uv 1st DH N SH 5500 WH WH 25.00 38.00 63 STD,GlassPack:Standard LSR 2 GAR 1st 2PNL N IPNL 550D WH WH 36.00 38.00 74 X S STD,Glass Pack:Standard LSR 3 BED3 1st DH N 1 PNL 5500 WH WH 52.00 50.00 102 x S STD,GlassPack:Standard LSR 4 BED3 1st 2 PNL N 1 PNL 5500 WH WH 36.00 37.00 73 x S STD,TMP:Full, LSR 5 KITCH 1st PD N PD 5400 WH WH 72.00 80.00 152 Glas Pack:Standard X X 2PNL STD,GlassPack:Standard LSR 6 BED2 tat 2 PNL N 1 PNL 5500 WH WH 36.00 37.00 73 x S STD,GlassPack:Standard LSR 7 BED2 1st 2PNL N 1 PNL 550D WH WH 52.00 50.00 102 X S STD,TMP:Full,Obscure LSR 8 BATH 1st 2PNL N 1PNL 5400 WH WH 35.00 24.00 59 Glass-Low E:Full, X s Glas Pack:Standard SPECIAL CONSIDERATIONS: Wrap Color Interior Casing Type Bay or Bow window: eatboard material(vinyl only-Birch or Oak) Bay Project Angle(30 or 45) Bay Flanker Type(DH,SH,or Csmnt) Top of window to soffit(inches) If tied to soffit,color of soffit material I have reviewed and agree with all the job specifications above and the Construct Roof(Yes or No)' Special Terms and Conditions on the following page Garden Window: Seaboard Material(vinyl only-White Pionite,Birch or Oak) Wall Thickness(inches) Customer Signature Additional Shelf(Yes or No) There is no guarantee that new shingles will match existing color. WINDOW SPECIFICATION SHEET - Spec.Sheet#: 9756350 Sheet: 2 of 2 Customer: Ronald Hughart Job#: 9756350 Consultant: STACY A DEANGELO Date: 01/02/2017 New Window Existing Window Hinge Locations Measurements Grids Product Options Labor Options From outside, Left to Right Bays,Bowls Location Color Rough Opening #of bars #of bars Csmnts,1 Pnl, use L,RorS Glass Misc Items Hardware Code Screens For doors use ft `g V 0 a o o Mull "S"=stationary or w Style Wraps � rn a `o u "X"=operating Room Floor Code (Y/N) Style Code Series Code u'S S = H vi ci a x > _ > z STD,TMP:Full.Obscure LSR 8 MEATH 1st 2PNL N 1PNL 6400 WH WH 36.00 24.00 60 Glass-Low E:Full, X S GlassPack:Standard STD,GlassPack:Standard LSR 1 MBED 1st 2PNL N 1 PNL 5500 WH WH 52.00 50.00 102 x S 0 STD,GlassPack:Standard LSR 1 MBED 1st 2PNL N 1 PNL 5500 WH WH 73.00 37.00 110 x S 1 SPECIAL CONSIDERATIONS: Wrap Color Interior Casing Type Bay or Bow window: eatboard material(vinyl only-Birch or Oak) Bay Project Angle(30 or 45) ay Flanker Type(DH,SH,or Csmnt) Top of window to soffit(inches) If tied to soffit,color of soffit material I have reviewed and agree with all the job specifications above and the Construct Roof(Yes or No)' Special Terms and Conditions on the following page Garden Window: eatboard Material(vinyl only-White Pionite,Birch or Oak) Wall Thickness(inches) Customer Signature Additional Shelf(Yes or No) There is no guarantee that new shingles will match existing color.