HomeMy WebLinkAboutLomanco- Ridge VentFlorida Building Code Online
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVX...
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Evaluation Entity
Quallty Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Lomanco, Inc
2101 West Main
Jacksonville, AR 72076
(501)982-6511
acarter@lomanco.com
Andrew Carter
acarter@lomanco.com
Andrew Carter
2101 West Main Street
Jacksonville, AR 72076
(501)982-6511 Ext 361
acarter@lomanco.com
Andrew Carter
2101 West Main Street
Jacksonville, AR 72078
(501)982-6511 Ext 361
acarter@lomanco.com
Roofing
Roofing Accessories that are an Integral Part of the Roofing System
Evaluation Report from a Product Evaluation Entity
Miami -Dade BCCO - EVL
Miami -Dade BCCO QUA
08/16/2016
Miami -Dade 8CCO - VAL
Standard
Miami --Dade TAS 100(A)
Y®ar
1995
of 2 10/1/2015 2:06 PM
Florida Building Code Online
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBG Approval
Date Approved
iittp:r/www.tlorlaat)uitamg.orgipr,'pr_app_ati.aspx-rparaln=vur vA...
Method 1 Option C
06/29/2015
07/02/2015
07/09/2015
FL Model, Number or Name Description
- -
2647.1 Lo-OmniRidge LOR9-4 Gun Nailahle-4' Ridge Vent for 9" Cap Shingles
Limits of Use
Installation Instructions '
Approved for use in HVHZ: Yes
I FL2847 R7 H LOR9-4 13470110.pdf
Approved for use outside HVHZ: Yes
I Verified By: Miami -Dade 8CCO - EVL
Impact Resistant: N/A
Created by Independent Third Panty:
Design Pressure: N/A
Evaluation Reports
Other: 1. Refer to applicable building codes for required
FL2847 R7 AF LOR9 4 1307011 Q.pdf
ventilation. 2. Omni Roll Ridge Vent shall not be installed on
roof hips. 3. Omni Ralf Ridge Vent shall not be connected at
j
ridge intersection, nor within 12" of any side wall or roof
I
protrusion, with a ventilation slot clearance of 12" from such
obstructions. 5. Omni Roll Ridge Vent shall not be installed
on roof mean heights greater than 33 feet.
-x-
2647.2. Lo-OmniRoll LOR-30
130' Gun Nailable Shingle Over Ridge Vent
Limits of Use
Approved for use in HVHZ: Yes
I installation Instructions
FL2847 R7 II LOR.30 13070111,pdf
Approved for use outside HVHZ: Yes
Verified l3yr Miami -Dade BCCO - EVL
Impact Resistant: N/A
Created by Independent Third Party:
Design Pressure: N/A
Evaluation Reports
Other: 1. Refer to applicable building codes for required
FL2847 R7 AE LOR-30 13070111.pdf
ventilation. 2. OmniRidge Vent shall not be installed on roof
mean heights greater than 33 feet.
2847.3 OmniRidge OR -4 l4' Shingle Over Ridge Vent
Limits of Use installation Instructions
Approved for use in HVHZ: Yes FI_2$47 R7 II Lomanco QR 4 - NOA 11-0502.03.pdf
Approved for use outside HVHZ: Yes j Verified By: Miami -Dade BCCO - EVL
Impact Resistant: N/A Created by Independent Third Party:
I Design Pressure: NIA Evaluation Reports
i Other: 1. Refer to applicable building codes for required FL2847 R7 AE Lomanco QPA- NOA 11-0602.03.pdf
ventilation. 2. OmniRidge Vent shall not be installed on roof
mean heights greater than 33 feet. J
IBack -Vert
Contact Us :: 1940 North Monroe Street, D16bassee FIL 3239R Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 201 State of Florida.:: Pryacv statement ;: Arrcccihllay statement :: Refnrd StaremenY
Under Florida law, email addresses are public records. if you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. 1f. you have any questions, please contact 850.487.1395.'Pursuant to Section
455.275(1), Florida Statutes, effective actober 1, 2612, licensees licensed under Chapter 455, F.S. must provide the Department with an email address F they have
one. The erl provided maybe used for official comm uncation with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine If you area licensee under Chapter
455, F.s., please click here.
Product Approval Accepts:
ER 18
�reE�E YF
of 2 10/1/2015 2:06 PM
MIAMI-DADE COUNTY
MIAMI.PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGITLATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/ecflmomy
Lomanco, Inc.
2101 West main Street
Jacksonville, AR 72076
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements. of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Lomanco Lo -Omni Roll LOR-30 Ridge Vent
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official
This NOA renews and revises NOA No. 08-0611.05 consists of pages 1 through 4.
The submitted documentation was reviewed by Juan E. Collao, R.A.
60
NOA No.: 13-0701.11
rM�pMMADe cou r
... � , Expiration Date: 09/04/18
Approval Date: 09/12/13
Page 1 of 5
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Ventilation
Materials: Plastic
Minimum Slope: 3:12
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
NOA No.: 13-©701.11
Expiration Date: 09/04/18
Approval Date: 09/12/13
Page 2 of 5
Test
Product
Product Dimensions Specification
Description
LOR-30 . 60"
x 14'/z" x 5/s" TAS 11.0
Ridge ventilation. system
0.625" thick
TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS:
Test
Product
Product Dimensions
Specification
Description Manufacturer
Roofing Nails Min. 12 ga.
TAS 114 Appendix E Corrosion resistant annular ring
Generic
shank nails
Roofing Nails Min. 12 ga.,
TAS 114 Appendix E Corrosion resistant smooth shank
Generic
1 3/41'
nails
MANUFACTURING LOCATION
1. Jacksonville, AR
EVIDENCE SUBMITTED:
Test A enc /Identifier
Name
R, eport
Date
Celotex Corporation Testing Service
ASTM D1929
MTS 520172
07/21/99
ASTM D635
Celotex Corporation Testing Service
ASTM D638
MTS 520172
10/22/99.
Celotex Corporation Testing Service
ASTM D638
MTS 520656 07/14/2000
PRI Asphalt Technologies, Inc.
TAS 100
LOM -003-02-01
01/15/03
PRI Asphalt Technologies, Inc.
TAS 100(A)-95
LOM -028-02-01
08/28/13
PRI Asphalt Technologies, Inc.
ASTM D635
LOM -030.02-01
07/23/13
PRI Asphalt Technologies, Inc.
ASTM D638
LOM -025-02-01
05/30/13
PRI Asphalt Technologies, Inc.
ASTM D1929
LOM -031-02-01
07/23/13
PRI Asphalt Technologies, Inc.
ASTM G155
LOM -025-02-01
05/30/13
NOA No.: 13-©701.11
Expiration Date: 09/04/18
Approval Date: 09/12/13
Page 2 of 5
APPROVED APPLICATIONS
Tradenarne: Lo -Omni Roil (LOR-30) Ridge Vent
System Type: Mechanical attachment of ridge vent system over composition shingles.
Slot: Truss Construction: Cut shall be 1-'/4" wide and 6" shorter at each end than the total
length of the ridge vent to be installed.
Ridge Pole Construction: Cut shall be 2-/4"" wide and 6" shorter at each end than the
total length of the ridge vent to be installed.
Installation: Mark proper alignment and end line for vents with chalk; snap a chalk line down both
sides of the ridge at a distance of 7" down from the peak as shown in the
manufacturer's installation instructions.
Center the length of vent along the ridge. Start nailing with minimum 1 Y4" rooting
nails placed 6" on center at manufacturer pre -marked locations. Use nails of sufficient
length to penetrate through the sheathing a minimum of 3/[6" or at least 1" into wood
plank decking thicker than 1 ". Cut lines are provided if more than one vent is being
used (See manufacturer installation manual). Additional pieces shall run in the same
direction as they unroll out of the carton.
Ridge Shingle: Using nail lines provided on top of vent, install the cap shingles directly to the vent, in
compliance with the shingle manufacturer's Notice of Acceptance (NOA) and
installation instructions, using roofing nails of sufficient length to penetrate through the
sheathing a minimum of 3/16" or at least 1" into wood plank decking thicker than 1
Ventilation Calculations: Refer to manufacturer's published literature.
NOA No.. 13-0701.11
Expiration Date: 09/04/18
Approval Date: 09/12/13
Page 3 of 5
LIMITATIONS:
1. Refer to applicable Building Code for required ventilation.
2. Ridge Vent shall comply with applicable Building Code.
3. Omni Roll Ridge Vent shall not be installed in conjunction with Gable vents.
4. Omni Roll Ridge Vent shall not be installed on roof hips.
5. Omni Roll Ridge Vent shall not be connected at ridge intersection, or within 12" of any side wall or roof
protrusion, with a ventilation: slot clearance of 12" from such obstructions.
6. Omni Roll Ridge Vent shall not be installed on roof mean heights greater than 33 ft.
7. For application over laminated shingles, apply a bead of silicone caulking or roof cement to the underside of the
outer baffle and at exposed edges.
S. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 9N-3 of the Florida Administrative Code.
NOA No.. 13-0701.11
Expiration Date: 09/04/18
Approval Date: 09/12/13
Page 4 of 5
M
;;,:�. ��s n�E ��x rewe�neasr a'a s'i r rr•e�w
':.:. -MOM!!es
Lo-Omm ROLL RIDGE VENT LOR-34
END OF THIS ACCEPTANCE
NOA No.: 13-0701.11
MI0`MI'�Erc�unin Expiration Date: 09/04/18
Approval Date: 09/12/13
Page 5 of 5