Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Lomanco- Ridge Vent
Florida Building Code Online http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVX... Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Evaluation Entity Quallty Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Lomanco, Inc 2101 West Main Jacksonville, AR 72076 (501)982-6511 acarter@lomanco.com Andrew Carter acarter@lomanco.com Andrew Carter 2101 West Main Street Jacksonville, AR 72076 (501)982-6511 Ext 361 acarter@lomanco.com Andrew Carter 2101 West Main Street Jacksonville, AR 72078 (501)982-6511 Ext 361 acarter@lomanco.com Roofing Roofing Accessories that are an Integral Part of the Roofing System Evaluation Report from a Product Evaluation Entity Miami -Dade BCCO - EVL Miami -Dade BCCO QUA 08/16/2016 Miami -Dade 8CCO - VAL Standard Miami --Dade TAS 100(A) Y®ar 1995 of 2 10/1/2015 2:06 PM Florida Building Code Online Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBG Approval Date Approved iittp:r/www.tlorlaat)uitamg.orgipr,'pr_app_ati.aspx-rparaln=vur vA... Method 1 Option C 06/29/2015 07/02/2015 07/09/2015 FL Model, Number or Name Description - - 2647.1 Lo-OmniRidge LOR9-4 Gun Nailahle-4' Ridge Vent for 9" Cap Shingles Limits of Use Installation Instructions ' Approved for use in HVHZ: Yes I FL2847 R7 H LOR9-4 13470110.pdf Approved for use outside HVHZ: Yes I Verified By: Miami -Dade 8CCO - EVL Impact Resistant: N/A Created by Independent Third Panty: Design Pressure: N/A Evaluation Reports Other: 1. Refer to applicable building codes for required FL2847 R7 AF LOR9 4 1307011 Q.pdf ventilation. 2. Omni Roll Ridge Vent shall not be installed on roof hips. 3. Omni Ralf Ridge Vent shall not be connected at j ridge intersection, nor within 12" of any side wall or roof I protrusion, with a ventilation slot clearance of 12" from such obstructions. 5. Omni Roll Ridge Vent shall not be installed on roof mean heights greater than 33 feet. -x- 2647.2. Lo-OmniRoll LOR-30 130' Gun Nailable Shingle Over Ridge Vent Limits of Use Approved for use in HVHZ: Yes I installation Instructions FL2847 R7 II LOR.30 13070111,pdf Approved for use outside HVHZ: Yes Verified l3yr Miami -Dade BCCO - EVL Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: 1. Refer to applicable building codes for required FL2847 R7 AE LOR-30 13070111.pdf ventilation. 2. OmniRidge Vent shall not be installed on roof mean heights greater than 33 feet. 2847.3 OmniRidge OR -4 l4' Shingle Over Ridge Vent Limits of Use installation Instructions Approved for use in HVHZ: Yes FI_2$47 R7 II Lomanco QR 4 - NOA 11-0502.03.pdf Approved for use outside HVHZ: Yes j Verified By: Miami -Dade BCCO - EVL Impact Resistant: N/A Created by Independent Third Party: I Design Pressure: NIA Evaluation Reports i Other: 1. Refer to applicable building codes for required FL2847 R7 AE Lomanco QPA- NOA 11-0602.03.pdf ventilation. 2. OmniRidge Vent shall not be installed on roof mean heights greater than 33 feet. J IBack -Vert Contact Us :: 1940 North Monroe Street, D16bassee FIL 3239R Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 201 State of Florida.:: Pryacv statement ;: Arrcccihllay statement :: Refnrd StaremenY Under Florida law, email addresses are public records. if you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. 1f. you have any questions, please contact 850.487.1395.'Pursuant to Section 455.275(1), Florida Statutes, effective actober 1, 2612, licensees licensed under Chapter 455, F.S. must provide the Department with an email address F they have one. The erl provided maybe used for official comm uncation with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you area licensee under Chapter 455, F.s., please click here. Product Approval Accepts: ER 18 �reE�E YF of 2 10/1/2015 2:06 PM MIAMI-DADE COUNTY MIAMI.PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGITLATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/ecflmomy Lomanco, Inc. 2101 West main Street Jacksonville, AR 72076 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements. of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Lomanco Lo -Omni Roll LOR-30 Ridge Vent LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official This NOA renews and revises NOA No. 08-0611.05 consists of pages 1 through 4. The submitted documentation was reviewed by Juan E. Collao, R.A. 60 NOA No.: 13-0701.11 rM�pMMADe cou r ... � , Expiration Date: 09/04/18 Approval Date: 09/12/13 Page 1 of 5 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Ventilation Materials: Plastic Minimum Slope: 3:12 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: NOA No.: 13-©701.11 Expiration Date: 09/04/18 Approval Date: 09/12/13 Page 2 of 5 Test Product Product Dimensions Specification Description LOR-30 . 60" x 14'/z" x 5/s" TAS 11.0 Ridge ventilation. system 0.625" thick TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS: Test Product Product Dimensions Specification Description Manufacturer Roofing Nails Min. 12 ga. TAS 114 Appendix E Corrosion resistant annular ring Generic shank nails Roofing Nails Min. 12 ga., TAS 114 Appendix E Corrosion resistant smooth shank Generic 1 3/41' nails MANUFACTURING LOCATION 1. Jacksonville, AR EVIDENCE SUBMITTED: Test A enc /Identifier Name R, eport Date Celotex Corporation Testing Service ASTM D1929 MTS 520172 07/21/99 ASTM D635 Celotex Corporation Testing Service ASTM D638 MTS 520172 10/22/99. Celotex Corporation Testing Service ASTM D638 MTS 520656 07/14/2000 PRI Asphalt Technologies, Inc. TAS 100 LOM -003-02-01 01/15/03 PRI Asphalt Technologies, Inc. TAS 100(A)-95 LOM -028-02-01 08/28/13 PRI Asphalt Technologies, Inc. ASTM D635 LOM -030.02-01 07/23/13 PRI Asphalt Technologies, Inc. ASTM D638 LOM -025-02-01 05/30/13 PRI Asphalt Technologies, Inc. ASTM D1929 LOM -031-02-01 07/23/13 PRI Asphalt Technologies, Inc. ASTM G155 LOM -025-02-01 05/30/13 NOA No.: 13-©701.11 Expiration Date: 09/04/18 Approval Date: 09/12/13 Page 2 of 5 APPROVED APPLICATIONS Tradenarne: Lo -Omni Roil (LOR-30) Ridge Vent System Type: Mechanical attachment of ridge vent system over composition shingles. Slot: Truss Construction: Cut shall be 1-'/4" wide and 6" shorter at each end than the total length of the ridge vent to be installed. Ridge Pole Construction: Cut shall be 2-/4"" wide and 6" shorter at each end than the total length of the ridge vent to be installed. Installation: Mark proper alignment and end line for vents with chalk; snap a chalk line down both sides of the ridge at a distance of 7" down from the peak as shown in the manufacturer's installation instructions. Center the length of vent along the ridge. Start nailing with minimum 1 Y4" rooting nails placed 6" on center at manufacturer pre -marked locations. Use nails of sufficient length to penetrate through the sheathing a minimum of 3/[6" or at least 1" into wood plank decking thicker than 1 ". Cut lines are provided if more than one vent is being used (See manufacturer installation manual). Additional pieces shall run in the same direction as they unroll out of the carton. Ridge Shingle: Using nail lines provided on top of vent, install the cap shingles directly to the vent, in compliance with the shingle manufacturer's Notice of Acceptance (NOA) and installation instructions, using roofing nails of sufficient length to penetrate through the sheathing a minimum of 3/16" or at least 1" into wood plank decking thicker than 1 Ventilation Calculations: Refer to manufacturer's published literature. NOA No.. 13-0701.11 Expiration Date: 09/04/18 Approval Date: 09/12/13 Page 3 of 5 LIMITATIONS: 1. Refer to applicable Building Code for required ventilation. 2. Ridge Vent shall comply with applicable Building Code. 3. Omni Roll Ridge Vent shall not be installed in conjunction with Gable vents. 4. Omni Roll Ridge Vent shall not be installed on roof hips. 5. Omni Roll Ridge Vent shall not be connected at ridge intersection, or within 12" of any side wall or roof protrusion, with a ventilation: slot clearance of 12" from such obstructions. 6. Omni Roll Ridge Vent shall not be installed on roof mean heights greater than 33 ft. 7. For application over laminated shingles, apply a bead of silicone caulking or roof cement to the underside of the outer baffle and at exposed edges. S. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. NOA No.. 13-0701.11 Expiration Date: 09/04/18 Approval Date: 09/12/13 Page 4 of 5 M ;;,:�. ��s n�E ��x rewe�neasr a'a s'i r rr•e�w ':.:. -MOM!!es Lo-Omm ROLL RIDGE VENT LOR-34 END OF THIS ACCEPTANCE NOA No.: 13-0701.11 MI0`MI'�Erc�unin Expiration Date: 09/04/18 Approval Date: 09/12/13 Page 5 of 5