FL16048-R4
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived ❑
Product Manufacturer Tri-Built Materials Group,LLC
Address/Phone/Email PO Box 70
Rutherford,NJ 07070
(800) 516-1485
david.ruiz@tribuiltm g.com
Authorized Signature David Ruiz
david.ruiz@tribuiltmg.com
Technical Representative David Ruiz
Address/Phone/Email 250 Route 17 North
East Rutherford,NJ 07073
(201)842-2449
david.rulz@tribuiltmateriaisgroup.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/16/2017
Validated By John W. Knezevich,PE
5
2 Validation Checklist-Hardcopy Received
Certificate of Independence FL16048 R4 COI 2016 01 CO I Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970;• 2009
ASTM.,G155 2005
FRSA/TRI April 2012(04-12) 2012
TAS 103 1995
Equivalence of Product Standards
Certified By
Sections from the Code
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtFPmdYiND... 1/11/2017
Florida Building Code Online Page 2 of L
Product Approval Method Method 1 Option D
Date Submitted 10/06/2016
Date Validated 10/17/2016
Date Pending FBC Approval 10/19/2016
Date Approved 12/13/2016
Summary of Products
FL# Model, Number or Name Description
16048.1 TRI-BUILT Roof Underlayments Self-adhering, modified bitumen roof underlayments
Limits of Use Installation Instructions
Approved for use In HVHZ: No FL16048 R4 II 2016 10 FINAL ER TRI-
Approved for use outside HVHZ:Yes BUILT UNDERLAYMENTS FL16048-R4.Ddf
Impact Resistant: N/A Verified By: Robert Nleminen PE-59166
Design Pressure:+N/A/-67.5 Created by Independent Third Party: Yes
Other: 1.)The design pressure noted herein pertains to use Evaluation Reports
of foam-on tile systems overtop the self-adhering FL16048 R4 AE 2016 10 FINAL ER TRI-
underlayment for one particular application.See ER Section BUILT UNDERLAYMENTS FL16048-R4.odF
5.6.4 for details.2.)Refer to ER Section 5 for other Limits of Created by Independent Third Party: Yes
Use.
Back Neat
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to
section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under
Chapter 455,F.S.,please dick here.
Product Approval Accepts:
® eche,
C�edlt Card^
siiM
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtFPmdYiND... 1/11/2017
QOTRINITYIERD
Certificate of Authorization#9503
January I, 2016
RE: Certification of Independence, Florida F'.A.C. Rule 61 G20-3
To Whom It May Concern:
This letter serves to document the following in accordance with Florida F.A.C. Rule 61 G20-3:
1. Exterior Research&Design, LLC.d/b/a Trinity I ERD does not have,nor does it intend to acquire or
will it acquire,a financial interest in any company manufacturing or distributing products it evaluates.
.2. Exterior Research& Design, LLC. d/b/a.Trinity I ERD isnot owned, operated or controlled by any
company manufacturing or distributing.products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire,, a financial interest in :any company
manufacturing or distributing products for which thets_evaluation reporare being issued.
4. Robert Nieminm RE does not have;nor will acquire,a:financial interestin any other entity involved
in the approval process of the product.
5. Building Code Evaluations issued by TrinitylERD and Robert Nieminen,P.E.are not,in anyway,.to'be
construed to mean or imply that7rinitylERD or Robert;Nieminen, RE.are the Designer of Record
for any project on.which the.Evaluation Report is/was used for permitting or design guidance unless
retained specifically for that purpose on a;given project.
Please contact our.office with any questions..
Sincerely,
Robert Nierninen, P.E.
Florida Reg.No.59.166
Vice President
Email:robertnieminen@trinityerd.com
EXTERIOR RESEARCH R OESIGN, LLC. d/b/a TrinitylERD - Certificate of Authorization'#9503
MAIN:80 Yesier Way . Suite 200 .'Seattle, WA 98304 ..P: (206) 467-0054 . F.: (206).467-5840
EAST: 393 Christian Street Unit 13 . Oxford, CT 66478 .P::(2.03) 262-9245 • F. (203) 262-9243
EXTERIOR RESEARCH&DESIGN,I.I.C.
` � Certificate of Authorization#9503
TRINI fl 1�/ ERD 353 CHRISTIAOXF.ORD,STREET,UNIT#13 CT 6478
PHONE; (203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Allied Building Products Corp. Evaluation Report A42960.10.12-R4
dba TRI-BUILT Roofing Products F1.16048-114
9050 Louisiana Street Date of Issuance:10/25/2012
Merrillville,IN 46410 Revision 4: 10/06/2016
SCOPE:
This Evaluation Report is.issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The.documentation submitted.has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida .Building .Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) .Florida 'Building Code
sections noted herein.
DESCRIPTION: TRI-BUILT Roof Underlayments
LABELING: Labeling shall be. in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED.COMPLIANCE: This'Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that:relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert.Nieminen, P.E. if the product
changes or the referenced:Quality Assurance documentation changes.'Trinityl ERD requires a complete.review of this
Evaluation Report relative to updated.Code requirements.with. .each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in
advertising.literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION'Upon request,'a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
-its distributors and shall be available for inspection atthe job site at the request of the Building Official.
This Evaluation Report consists of.pages 1 through 5.
.Prepared by: A t!tttjr,r+ —
gZOT,7
Robert J.M.Nieminen P.E. +a;�s $ 'The Ncsimilegea(apioaringwas authorized byRobert kleminen
' t P.E.on 10/06/2016.This does notsemas an electronically signed
Florida'Registration No.5.9166,Florida DCA ANE1.983 documenti signed,sealed hardmples haw been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
.1. Trinity]ERO:does not.have; nor does it intend to acquire or will It acquire, a financial.interest in.any company manufacturing or
distributing:products it evaluates.
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are.being.issued..
4. Robert Nieminen,P.E.does.not have;nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen,P.E.are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY J ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:.
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: TRI-BUILT Roof Underlayments,as produced by TRI-BUILT,have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordance with:the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set.forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.4,1507.2.8,1507.2.9:2, Physical Properties ASTM D1970 2009
1507.4.5.1,1507,5:3',1507.7.3.
1504.6 Accelerated Weathering ASTM G155 2005
1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012.
1523:6.5.2.1. Physical Properties TAS 103 3995
3. REFERENCES:
Enti Examination Reference Date
ERD(TST6049) Physical Properties S40540.02.134 02/19/2013
ERD(TST6049) Physical Properties 540540.11.13 11/19%203
ERD(TST6049) Physical Properties 540540.03.14 03/26/2014
ERD(TST6049) Physical Properties 544870:04;14=2. 04/02/2014
ERD(TST6049). Physical Properties S441870.04.14-3 04/02/'2014
ERD(TST6049) Physical Properties 544870.04.14-1 04/SO/2014
ERD(TST6049) Physical Properties 544870:04.14-4 04/10/2014
ERD(TST6049) Physical Properties 543530.02.14-1-R1 05/14/2014
ERD(TST6049) Physical Properties $43530.05.14 05/28/2014
ERD(TST6049) Physical Properties S405.40.10.14 10/31/2014
ERD(TST60Q9) Physical Properties SC7645.02.15' 02/13/2015
ERD(TST6049), Accelerated:WdatWing SC8520.04.15 05/27/2015
UL,LLC.(QUA9625) Quality Control Multiple-Listing:1116814 09/04/2015
UL,LLC:(QUA9625) Quallty:Control Service Confirmation, Exp.10/16/2017
4: PRODUCT DESCRIPTION:
4.1 Self-Adherina Underlayments:
4.1.1. Tri-Built.Sand-R SA ShingleUnderlayment is a seMadhering, glass-mat reinforced, sand-surfaced, SBS
modified bitumen roof underlayment,with a 36=in.ch sheet width.
4.1.2 Tri-Built.S/A HT'TU Underlayment is a self-adhering;non=woven polyester fabric surfaced,SBS modified
bitumen:roof un.derlagment
4.1:3 Tri-Built, Smooth HT S/A. Underlayment is a. self adhering; :glass=mat reinforced, fl'm-surfaced; SBS-
modified
BSmodified bitumen roof underlayment.
S. LIMITATIONS:
5.1 This.is:a building.code evaluation. Neither Trinity J.ERD noir Robert Nieminen, P.E. are, in any way,the
Designer of Record for any project on which this Evaluation Report,. or previous versions thereof, is/was
used for.permitting or designguidance unless retained:specifically for that purpose.,
5.2. This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification :is: not,part of this Evaluation :Report; refer to current Approved Roofing Materials
Directory for fire ratings of this:product.
Exterior Research and Design;LLC. EvaluationReport A42960.10.12-114
Cerci lcute of Authodkodun N9503 FBC,N0N-HVHZ.EVAWATI0N F1.16048-114
Revision 4:10/66/2016
Page 2 of 5
TRINITY J ERD
5.4 TRI-BUILT Roof Underlayments, may be used with any prepared. roof cover where the product is
specifically referenced within.FBC approval documents. If not.listed,a request may be made to the AHJ for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the underlayments are as follows:
TABCE 1 ROOF COVER OPTIONS
Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes Slate
Shingles &Shingles
Tri-Built Sand-R SA Shingle Yes No. No No Yes Yes
Underlayment
Tri-Built S/A HT TU Yes
Yes Yes Yes Yes Yes
Underlayment See 5.5.1
Tri-Built Smooth HTS/A Yes No No Yes Yes Yes
Underlayment
5.5.1 "Foam-On Tile" is limited to. use of the following Approved.tile adhesives unless tensile adhesion/long
term aging data from an accredited testing laboratory is provided.
Tri-Built S/A HT TU Underlayment with 3MTm 2-Component Roof Tile Adhesive AH-160 (FL6332) or
Dow TileBondl Roof Tile Adhesive(FL717)
5.6 Allowable substrates are noted below:
5.6:1 Direct-Bond to'Deck:
Tri-Quilt.Sand=R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment:or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D4.1
primed Southern Yellow Pine;ASTM`D41 primed.-structural concrete.
While not required over plywood, OSB or 'Southern Yellow Pine. substrates, TRI-BUILT recommends
priming the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT
requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the
self-adhering underlayment.
5.6.2 Bond-todrisuiation:
Tri-Built.Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment.or Tri-Built Smooth HT S/A
Underlayment applied to:
Dens Deck Prime;SECU ROCK Gypsum-Fiber Roof Board.
For installation under.mechanically attached prepared:roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam=op tile systems (Tri-Built S/A.HT TU Underlayment only), insulation attachment shall be
designed by a qualified design professional and installed based on testing of the insulation/underlayment
system in'accordance with FM 4474,Appendix D or TAS 1141 Appendix J.
5.6.3 Bond to Mechanically Attached Base Laver:
Tri-Bullt Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ ASTM D226,Type l:or 11 felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on tile .systems (Tri=Built 5/A HT TU
Underlayment only),base layer shall be attached per minimum requirements of FRSA/TRI April'2012(04-
12).
Exterior Research and Design,I.I.C. Evaluation Report A42960.10.12-R4
Certificate ajAuthorizatlon#9503 FBC NON-HVHZ EVALUATION FL16048-114
Revision 4:10/06/2016
Page 3 of 5
TRINITY(ERD
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all'underlayment systems beneath foam-on tile systems,where
the underlayment forms part.of the load-path. The following wind uplift limitations apply to direct=deck
underlayrhent systems that:are not addressed in FRSA/TRI April 2012(04-12) and ate used in foam-on tile
applications. Maximum. Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind pressures.
5.6:4.1. Maximum Design Pressure--45.0:gsf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional).ASTM D41
Underlayment: Tri-Built S/A HTTU Underlayment;self-adhered.
5.6:4.2 Maximum Design.Pressure=-67.5ipsf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: Soprema Elastocol 600c
Underlayment: Tri-Built S/A HTTU Underlayment;self-adhered.
5.6.4.3 Maximum Design Pressure 60.0 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails(FBC 1517:5.1)
and tin caps(FBC 1517:5:2)spaced 6-inch o.c..at the 4-inch laps and 6-inch o.c.in three,
equally spaced rows in the center.of the sheet.
Underlayment: Tri.-Built 5/A HT TU Underlayment,.self-adhered:
5.7 Exposure Limitations:
.51.1 Tri-Built.Sand-R•SA Shingle Underlayment or Tri-Built Smooth HTS/A Underlayment,shall not be left
exposed for longer than 30-days after'installation
5,7.2 Tri-Built S/A HTTU Underlayment shall not.be left exposed for longer than 1.80-days after installation.
6 INSTALLATION:
6.1 TRI=BUILT.Roof Underlayments°shall be installed in accordance with TRI-BUILT published installation
requirements:subject to the(Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and.check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application,and prime:the substrate(if applicable).
63 Tri-Built Sand-R SA Shingle Underlayment Tri-Built S/A HT TU Underlayment or Tri-Built Smooth.HT S/A
Underlayment:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed..
6:3:2 Non-Tile applications;
While priming is optional,TRI-BUILT recommends'prim ing the deck if the final roof cover is not slated for
installation within 24 hours:.
Apply sheet parallel to the roof edge. Rollout approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film•diagonally while holding the
membrane tight. Firmly roll,.broom or hand-press the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below,sealed in accordance with
TRI-BUILT requirements.
Exterior Research and.Design,U.C. Evaluation Report A42960.10.12-R4
Certificate of Authorization#9503 FBC NON-HVHz EVALUATION FL16048-114
Revision 4:10/06/2016
Page 4 of 5
QOTRINITYIERD
When installing at slopes above 8:12,TRI-BUILT recommends back-nailing in the overlap area at the top of
the sheet at 12-inch ox.
For Valleys and Ridges: Cut underlayment into 4 to 6'foot lengths.Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction.. For valleys,.apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications(Tri-Built S/A HT TU Underlavment only):
Reference is made to 'FRSA/TRI April :2012 (04-12) Installation Manual :and Table.1 herein, using the
instructions noted above asa guideline.
For foam-on tile applications, reference is made to Section S:6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI Aprill42012(04-12).
Tile: shall be loaded and staged in a .manner that prevents tile slippage and/or damage to the
underlayment.
7. BUILDING PERMIT-REQUIREMENTS:
As required by-the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the rioted QA agency for information on product locations covered for F,A.C.:Rule 9N-3 QA requirements.
9. QUALITY ASSURANCE!ENTITY:
UL,LLC—QUA9625;,(314;)578-3406;k.chancellor@us..ul.com
-END.OF EVALUATION REPORT-:
Exterior Research and.Design,LLC- Evaluation Report A42960:10.12-R4
CertiJknte ofAuthorfiavon#9503 FBC NON-HVHZ EVALUATION FL16048-R4
Revision 4:10/06/2016
Page 5 of 5
EXTERIOR RESEARCH &DESIGN,I.I.C.
r�oCertificate of Authorization#9503
STREETUNIT#13
TRII�IITY ERD 353 CHRISTIAOXFORD,,CT 06478
PHONE: (203)262-9245
FAX: (203)262-9243
EVALUATION REPORT
Allied Building Products Corp. Evaluation Report A42960.10.12-R4
dba TRI-BUILT Roofing Products FL16048-114
9050 Louisiana Street Date of Issuance:10/25/2012
Merrillville,1N 46410 Revision 4: 10/06/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the,applicable rules and regulations governing the use of
construction materials in the State of Florida.The.documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida. Building Code, 'Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition .(2014) Florida Building Code
sections noted herein.
DESCRIPTION: TRI-BUILT Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED.COMPLIANCE: ThisEvaluation Report is valid until.such time as the namedproduct(s)'changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that:relate'to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or.the referenced Quality Assurance documentation changes: Trinity I ERD requires.a complete.review of this
.Evaluation Report relative,to updated.Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report.number preceded by the words "Trinity I ERD Evaluated" may be displayed in
adVertising aiterature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION:Upon request, a copy of this entire Evaluation Report:shall be provided to:the userby the manufacturer or
its distributors.andshallbe available for inspection.at the.job site,at the.request of the Building Official.
.This Evaluation.Report consists of.pages 1 through 5.
Prepared by: S1p�%grnr}'�f^
Robert J.M.Nieminen P.E. 'fiF� =''r�Z. The faraimileseal appearingwasauthorized byRobert Nleminen,
til+l{U�,�,� �is0``�` P.E.on10/06/2016.This does;notserveas anelectroniwltysigned
Florida Registration No.59166,Florida DCA ANE1.98.3 document:Signed,sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named dient
CERTIFICATION OF INDEPENDENCE:
.1. Trinity]ERD.does not.have, nor does it intend to acquire or will it acquire; a:financial Interest in any company manufacturing or
distributing.products.it evaluates.
2. Trinity)ERD Isnot owned,,o.perated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert'Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing ordistributing products for
which the evaluation reports are being issued..
4. .Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither'TrinitylERD nor Robert Nieminen,P.E.are, in.any way,the Designer of'Record for any
project on which this Evaluation-Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose;
TRINITY(.ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance.Statement: TRI-BUILT Roof Underlayments,as produced by TRI-BUILT,have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordance with the following Standards..
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.4,1507.2.8,1507.2.9.2, Physical Properties ASTM.D1970 2009
1507.4.5.1,1507.5.3,1507.7.3
1504.6 Accelerated Weathering ASTM G155 2005
1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012
1523:6:5;2.1 Physical Properties TAS 103 1995
3. REFERENCES:
Entity Examination Reference Date
ERD(TST6049) Physical Properties $40540.02.13=1 02/19/2013
ERD(TST6049) Physical Properties 540540.11.13 11/19%2013
ERD(TST6049) Physical Properties S40540.03.14 03/26/2014
ERD(TST6049) Physical Properties 544870.04:14-2 04/02/2014
ERD(TST6049) Physical Properties S44870.04.14-3 04/02/2014
ERD(TST60491 Physical Properties 544870.04.14-1 04/10/2014
ERD(TST6049) Physical Properties 544870.04:14-4 04/10/2014
ERD(TST6049) Physical Properties 543530.02,14-1-111 05/14/2014
ERD(TST6049) Physical Properties 543530.05.14 05/28/2014
ERD(TST6049) Physical Properties 540540.10.14 10/31/2014
ERD(TST6049) Physical Properties SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SC8520.04.15 05/27/2015
UL,LLC..(QUA9625) Quality Control Multiple=Listing.1116814 09/04/2015
UL,LLC.(CWA96251 Quality Control Service Confirmation Exp.10/16/2017
4. PRODUCT DESCRIPTION:
4.1 Self-Adherina Underlayments:.
4.1.1. Tri-Built Sand-R SA ShingleUnderlayment is a self,adhering,.glass=mat reinforced, sand-surfaced, SBS
modified bitumen roof underlayment,with a 36-inch sheet width.
4.1.2. Tri-Built S/A HT TU Underlayment is a self-adherin&.non-woven polyester fabric surfaced,SBS modified
bitumen.roof und6dayrnent
4.1.3 Tri-Built. Smooth :HT S/A Underlayment is A. :self-adhering, glass.-mat .reinforced, film-surfaced, SBS
modified bitumen roof underlayment.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinityl.ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of'Record for any project on which this Evaluation Report, or previous versions thereof, is/was
us..e.d f..or permitting or design guidance unless retained,specifcallyfor that purpose..
5;2. This Evaluation Report is not for use in'the HVHZ.
5.3 Fire Classification is. not part of this: Evaluation ;Report; refer to current Approved Roofing Materials
Directory for fire ratings of tiis,product.
Exterior Research and Design,I.I.C. Evaluation Report.A42960:10.12-R4
Cerriftate.afAuthorizatlon#9503 FBC NON-HVHZ EVALUATION F1.16048-114
Revision 4:10/06/2616
Page 2 of 5
TRINi-rY I ERD
5.4 TRI-BUILT Roof Underlayments. may be used .with any prepared roof cover where the product is
specifically referenced within.FBC approval documents. If not listed,a request may be made to the AHJ for
approval based on this evaluation combined:with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the underlayments are as follows:
TABLE 1 ROOF COVER CiPTIDNS
k_2 , n
Underlayment Asphalt Nail-On Tile Foam=On Tile Metal Wood Shakes Slate
Shingles &Shingles
Tri-Built Sand-R SA Shingle Yes No. No No Yes Yes
Underlayment
Tri-Built S/A HT TU Yes
Yes yes Yes Yes Yes
Underlayment See 5.5.1
Tri-BuiltSmooth HTS/A Yes No No Yes Yes Yes
Underlayment
5.5.1 "Foam-On.Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion /long
term aging data from an accredited testing laboratory is provided.
➢ Tri'-Built S/A HT TU Underlayment with 3MTm 2-Component Roof Tile Adhesive AH-160 (FL6332) or
Dow.TileBo.ndT"Roof Tile Adhesive(FL717)
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond-to Deck:
Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment:or Tri-Built Smooth HT S/A
Underlayment:applied to:
➢ Plywood;ASTM D41 primed plywood; OSB;ASTM 041 primed OSB;Southern Yellow Pine;ASTM D41
primed"Southern Yellow Pine;ASTM D41 primed structural concrete.
While. not: required over plywood,. OSB or.Southern Yellow Pine substrates, TRI-BUILT recommends
priming the deck if the final roof cover is not slated for installation'within 24 hours. Note: TRI-BUILT
requires tongue-and-groove board:decking be covered with .plywood or OSB prior to installation of the
self-adhering underlayment.
5.6.2 Bond-to-insulation:
Tri-Built Sand:-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment.applied to:
➢ Dens DeckPrime.SECUROCK Gypsum-Fiber Roof Board.
For installation under.mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be
designed by a qualified design professional and installed based on testing of the insulation/underlayment
system in'accordahce with FM 4474,Appendix.D or TAS 114,Appendix J.
5.6.3 Bond to MechanicallyAttached Base Laver:
Tri-Built Sand-R SA Shingle Underlayment,Trl-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlaymentapplied to:
ASTM D226, ,Type Lor II felt.
For installations:under mechanically attached prepared roof coverings, baselaye.r shall be attached per
minimum codified requirements. For installations: under foam-on tile systems (Tri-Built S/A HT TU
Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April'2012(04-
12).
Exterior Research and Design,I.I.C. Evaluation Report A42960.10.12-R4
Cutifimte of Autharizattan#9503 FBC'NON-HVHZ EVALUATION FL16048-114
Revision 4:10/06/2016
Page 3 of 5
C�o
TRINITY I ERD
5.6.4 Wind Resistance for Underlayment Systems in Foam=On Tile Applications: FRSA/TRI April 2012 (0442)
does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where
the underlayment forms part of the load=path. The following wind uplift limitations apply to direct-deck
underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2'(the 2 to 1 margin of safety
per FBC.1504.9 has already been applied). Refer to FBC 1609 for determination of design wind pressures.
5.6.4.1 Maximum Design Pressure=-45.0 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional)ASTM D41
Underlayment: Tri-Built S/A HTTU Underlayment;self-adhered.
5.6.4.2 Maximum Design Pressure= 67.5 psf.
Deck:. Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: Soprema Elastocol 600c
Underlayment: Tri-Built S/A HT TU Underlaymenti.self-adhered.
5.6.4:3 Maximum Design Pressure=-60.0 psf.
Deck: Min.19/32-inch plywood to meet project requirements to:satisfaction of AHJ.
Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1)
and tin caps(FBC 1517:5:2)spaced.6-inch o.c..atthe 4-inch laps and 6-inch o.c.in three,
equally spaced rows in theicenter of the sheet.
Underlayment: Tri-Built S/A HT TU Underlayment self-adhered.
5:7 Exposure Limitations:
5:7:1 Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT'S/A Underlayment shall not be left
exposed for longer than 30-days after installation
5.7..2 Tri-Built S/A`HT TU Underlayment shall not be left exposed for.longer than 180-days after installation.
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly
toremove any dust and debris prior to application,and.prime:the substrate(if applicable).
6.3 Tri-Built Sand-R SA Shingle'Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth:HT S/A
Underlayment:
6.3.11 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections
1507 for the type of prepared roof covering to be.installed.
6.3:2 Non-Tile applications:
While priming is optional,TRI-BUILT recommends priming the deck if the final roof cover is not slated for
installation within 24 hours:.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate-and unroll the remaining membrane as far as possible.
Once the.entire length of membrane is in place, peel-off the release film:diagonally while. holding the
membrane tight,. Firmly roll,.broorh or hand-press the menib.ra.ne into place to achieve a bond.
Horizontal seams should be minimum.3'-inches,configured to'shed water. Vertical;seams should be.6-
inches and staggered not less than 2-ft from vertical seams in the course below,.sealed in:accordance with
TRI-BUILT requirements.
Exterior Research and.Design,LLC. EvaluationReport A42960:30.12-R4
certificate ofAuthoruation#9503 FBC NON-HVHZ EVALUATION FL16048-R4
Revision 4:10/06/2016
Page 4.of 5
(-)o
TRINITY[ERD
When installing at slopes above 8:12,TRI=BUILT recommends back(nailing in the overlap area at the top of
the sheet at 127inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the.center of the valley or ridge in
each direction. For valleys,applythe sheet starting at the lowest point and work upward.
6:3.3 Tike Applications(Tri-Built S/A HT TU Underlayment only):
Reference is made to :FRSA/TRi April 2,012 (04-12) Installation Manual .and Table 1 herein, using the
instructions noted above as a guideline.
For foam-on tile applications,reference is made to Section•5.6.4 herein for wind resistance limitationsthat
fall outside the scope of FRSA/TRI April'2012(04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment:
7. BUILDING PERMIT REQUIREMENTS:'
As required by'the Building Official or Authority Having Jurisdiction'in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the noted.QA agency for information on product locations covered for F.A.C.Rule 9N-3 QA requirements.
9. QUAUTY.AssuRANCE'Eknm.
UL,LLC—QUA9625;(314:)578-3406;k.chancellor@:us.ul.com
END OF EVALUATION REPORT
'Exterior Research andMesign,LLC. Evaluation'Report A42960:30.12-R4
Certificate of Authorization#9503 FBCNON-1M4Z EVALUATION -FL16048-R4
Revision 4:10/U6/2016