Loading...
HomeMy WebLinkAboutNotice of Acceptance MIAMI-DADE MIAMI-DADE COUNTY ® PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eoy/economy Soprema,Inc. 1688 Jean-Berchmans-Michaud Drummondville,Quebec J2C OC2 Canada SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section(In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such'product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Soprema Lastobond and Resisto Underlayment Products LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has ubeen a revision or change in the materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 13-0530.02 and consists of pages 1 through 7. The submitted documentation was reviewed by Jorge L.Acebo. NOA No.: 15-0508.04 M114M. ADE COUNTY Expiration Date: 09/29/20 Approval Date: 09/24/15 Page 1 of 7 ROOFING COMPONENT APPROVAL Category Roofing Sub-Category: Underlayment Materials: SBS SCOPE: This acceptance is for Soprema Lastobond and Resisto Underlayment Products as manufactured by Soprema Inc., as described in this Notice of Acceptance,for use with approved prepared roof'assemblies as described in this Notice of Acceptance;designed to comply with the Florida Building Code,including the High Velocity Hurricane Zone of the Florida Building Code. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description Lastobond Shield 36"x 75'rolls ASTM D1970 SBS self-adhereing asphalt sheet material for use Manufacturing Location#1 or as an underlayment for Ice Dam Protection m 45"x 75'rolls sloped roof assemblies. **Available as Lastobond Shield 36,and Lastobond Shiled 45 for the 36" wide and 45"wide rolls. Lastobond Pro HT-N 36"x 65'rolls ASTM D1970 SBS self-adhering asphalt sheet material for use as Manufacturing Location#1 an underlayment for Ice Dam Protection in sloped roof assemblies. Resisto SA Smooth Ply 40 40"x 65'rolls ASTM D1970 SBS self-adhering'asphalt sheet material for use as Manufacturing Location#1 an underlayment for Ice Dam Protection in sloped roof assemblies. Lastobond Shield HT 36"x 75'rolls ASTM D1970 SBS self-adhering asphalt sheet material for use as Manufacturing Location#1 an underlayment for Ice Dam Protection in sloped roof assemblies. i. Lastobond Pro HT-S 36"x 65'rolls ASTM D1970 SBS self-adhering asphalt sheet material for use as Manufacturing Location#1 an underlayment for Ice Dam Protection in sloped roof assemblies. Lastobond 195 36"x 75'rolls ASTM D1970 Self-adhering glass fleece reinforced,SBS Manufacturing Location#1-3 modified bitumen roofing underlayment. Resisto LB1236 36"x 65'rolls ASTM D1970 Self-adhering glass fleece reinforced,SBS Manufacturing Location#1-3 modified bitumen roofing underlayment. Resisto LB1244 44"x 75'rolls ASTM D1970 Self-adhering glass fleece reinforced,SBS Manufacturing Location#1-3 modified bitumen roofing underlayment. NOA No.: 15-0508.04 MIAM4DADE COUNTYExpiration Date: 09/29/20 Approval Date: 09/24/15 Page 2 of 7 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description Lastobond Eaves Protection 36"x 75'rolls ASTM D1970 Self-adhering glass fleece reinforced,SBS Sheet modified bitumen'roofing underlayment. Manufacturing Location#1-3 Lastobond Smooth Seal HT 36"x 65'rolls ASTM D1970 Self-adhering glass fleece reinforced,elastomeric Manufacturing Location#1-3 bitumen roofing underlayment. Lastobond TU HT 39 s/s"x 65 3/5' TAS 103 and Self-adhering glass fleece reinforced,SBS Manufacturing Location#3 rolls ASTM D 1970 modified bitumen roofing underlayment. MANUFACTURING LOCATION: 1. Drummondville,Quebec(Canada) 2. Wadsworth,OH 3. Gulport,MS EVIDENCE SUBMITTED: Test A2encv Test Identifier Test Name/It6ort Date Underwriters Laboratories,Inc. R21824 UL790 09/11/15 Trinity I ERD SOPC-SC8970.08.15 ASTM D1970/TAS 110 08/31/15 S31370.03.10-1-R1 ASTM D1970 04/07/10 S37210.11.11 ASTM D1970 11/09/11 S37210.12.11 ASTM D1970 12/01/11 540540.02.13-1 ASTM D1970 02/19/13 S40540.11.13 ASTM D1970 11/19/13 S43530.02.14-1-R1 TAS 103 05/14/14 S44870.04.14-4 ASTM D1970 04/10/14 S44870.04.14-1 ASTM D1970 04/10/14 544870.04.14-3 ASTM D1970 04/02/14 S44870.04.14-2 ASTM D1970 04/02/14 S40540.10.14 ASTM D1970 10/31/14 SOPC-SC8520.04.15 TAS 103 04/27/15 r NOA No.: 15-0508.04 MMDADECOUNTYM Expiration Date: 09/29/20 "• ' Approval Date: 09/24/15 Page 3 of 7 APPROVED ASSEMBLIES: Deck Type 1: Wood,Non-insulated Deck Description: 19/32"or greater plywood or wood plank System E(1): Base sheet mechanically fastened,membrane adhered. Base Sheet: One or more plies of ASTM D226 Type 11 or ASTM.D2626 with a minimum 4"side lap and a 6"end lap mechanically fastened to deck with approved nails and tin caps 6"o.c. at the laps and two staggered rows 12"o.c. the field of the roll. Membrane: One ply of Lastobond Shield,Lastobond Pro HT-N,Resisto SA Smooth Ply 40,Lastobond Shield HT,Lastobond Pro HT-S,Lastobond TU HT,Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Smooth Seal HT,Resisto LB 1236 or Resisto LB 1244 with minimum 3-inch side laps and 6-inch end laps. Starting at the first course,parallel to the eave,align the membrane carefully by completely unrolling and setting it exactly where it will be installed. Once aligned,rewind one half of the length; Gently score the release paper on the high side of this roll,ensuring not to cut through the membrane's thickness. Unroll this first half by evenly peeling back the release paper while simultaneously and slowly pushing out the membrane. Repeat process for remaining one half of the length. Once installed,the membrane must be pressure rolled with a metal or rubber roller. Pressure shall be applied over the entire surface,paying particular attention to all side and end laps. Surfacing: Approved for Mechanically Fastened Metal Roofing,Wood,Shake&Shingles,Asphalt Shingles,Slate, Simulated Slate NOA No.: 15-0508.04 MIAMMADe courrnr Expiration Date: 09/29/20 • ' Approval Date: 09/24/15 Page 4 of 7 Deck Type 1: Wood,Non-insulated Deck Description: 19/32°'or greater plywood or wood plank System E(2): Base sheet mechanically fastened,membrane adhered. Base Sheet: One or more plies of ASTM D226 Type H or ASTM D2626;with a minimum 4"side lap and a 6"end lap mechanically fastened to deck with approved nails and tin caps 6"o.c. at the laps and two staggered rows 12"o.c. the field of the roll.. I Membrane: One ply of Lastobond TU HT with minimum 3-inch side laps;and 6-inch end laps. Starting at the first course,parallel to the eave,align the membrane carefully by completely unrolling and setting it exactly where it will be installed. Once aligned,rewind one half of the length. Gently score the release paper on the high side of this roll,ensuring not to cut through the membrane's thickness. Unroll this first half by evenly peeling back the release paper while simultaneously and slowly pushing out the membrane. Repeat process for remaining one half of the length. Once installed,the membrane must be pressure rolled with a metal or rubber roller. Pressure shall be applied over the entire surface,paying particular attention to all side and end laps. The Lastobond TU HT shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 12"o.c. at the side laps and 6" o.c. at the end laps. No nails or tin caps shall be exposed. I; Surfacing: Approved for Mechanically Fastened Cement or Clay Roof tiles.Lastobond TU HT may be used with any approved roof tile system adhered as specified in their current NOA using any foam adhesive listed and having a current adhesive NOA approval. i' r NOA No.: 15-0508.04 MIAMI•DADE COUNTY Expiration Date: 09/29/20 • 'Approval Date: 09/24/15 Page 5 of 7 i I i UmTATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with the applicable building code. Lastobond Shield,Lastobond Pro HT-N,Resisto SA Smooth Ply 40,Lastobond Shield HT,Lastobond Pro HT-S,Lastobond TU HT,Lastobond 195,Lastobond Eaves Protection Sheet, Lastobond Smooth Seal HT,Resisto LB1236 or Resisto LB1244 shall be installed in strict compliance with the applicable building code. 3. Lastobond Shield,Lastobond Pro HT-N,Resisto SA Smooth Ply 40,Lastobond Shield HT,Lastobond Pro HT-S, Lastobond TU HT,Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Smooth Seal HT,Resisto LB1236 or Resisto LB1244 shall be applied to a smooth,clean and dry surface,free from irregularities. Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. When a smooth,clean and/or dry surface cannot be obtained,the substrate shall be primed with Elastocol Stick prior to application.. 4. Lastobond Shield,Lastobond Pro HT-N,Resisto SA Smooth Ply 40,Lastobond Shield HT,Lastobond Pro HT-S, Lastobond TU HT,Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond',Smooth Seal HT,Resisto LB1236 or Resisto LB1244 shall not be applied over an existing roof membrane as a recover system but may be specified in the surfacing option of the approved assemblies. 6. Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Smooth Seal HT,Resisto LB 1236 or Resisto LB1244 shall not be left exposed as a temporary roof for longer than 30 days. 7. Lastobond Shield HT,Lastobond Pro HT-S,Lastobond Shield,Lastobond'Pro HT-N and Resisto SA Smooth Ply 40 shall not be left exposed as a temporary roof for longer than 90 days of application. 8. Lastobond TU HT shall not be left exposed as a temporary roof for longer than 180 days of application. 9. Lastobond Shield,Lastobond Pro HT-N,Resisto SA Smooth Ply 40,Lastobond Shield HT,Lastobond Pro HT-S, Lastobond TU HT,Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond,Smooth Seal HT,Resisto LB1236 or Resisto LB1244 may be used with any approved roof covering listing Lastobond Shield,Lastobond Pro HT-N,Resisto SA Smooth Ply 40,Lastobond Shield HT,Lastobond Pro HT-S,Lastobond TU HT,Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Smooth Seal HT,Resisto LB1236 or Resisto LB1244 within the Product Approval. If Lastobond Shield,Lastobond Pro HT-N,Resisto,SA Smooth Ply 40,Lastobond Shield HT,Lastobond Pro HT-S,Lastobond TU HT,Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Smooth Seal HT,Resisto LB1236 or Resisto LB1244 is not listed,a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Department for approval based on the necessary documentation to detail compatibility of the products,wind uplift resistance and fire resistance results. 10. When applying the membrane in the valley,start at the low point and work to the high point,rolling the membrane from the center outward in both directions. For ridge applications,center the membrane and roll from the center outwards in both directions. 11. Membrane shall be applied to protrusions, slope changes,valley,curb,and other roof top penetration details before any other sections of the roof. 12. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.: 15-0508.04 MIAMMADE COUNTY Expiration Date: 09/29/20 • • Approval Date: 09/24/15 Page 6 of 7 I , 13. Tiles must be staged onto Lastobond TU HT not to exceed 10-high,to the standard maximum roof pitch of 6:12 for flat tiles and 5:12 for lugged tiles. Lugged tiles staging at slope>5:12 shall use alternate staging method (bottom tile shall be inverted followed by eight tiles high on slope,as illustrated in.Figure 1 below). a [[ - '1 Figure 1: Alternate Staging Method At roof slopes greater than the preceding limitations all tiles shall be loaded onto a nominal 1"x 2"horizontal batten to prevent slippage. 14. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city,state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMFDADE COUNTY END OF THIS ACCEPTANCE NOA No.: 15-0508.04 MIAMI•DADE COUNTY Expiration Date: 09/29/20 • • ;' Approval Date: 09/24/15 Page 7 of 7 5 ' MIAMI DADE COUNTY MIAMI-DADE PRODUCT CONTROL SECTION a 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade-eov/economv GAF 1 Campus Drive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Timberline HD®,Timberline Natural Shadow",and Timberline American Harvest® Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been'a revision or change in the materials,use, and/or manufacture of the product or process.Misuse of this NOA as anendorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 13-0419.04 and consists of pages 1 through 6. The submitted documentation was reviewed by Juan E. Collao,RA. u'��'"`t •C, � NOA No.: 14-1022.20 aM1AM1-DMDEC0=UNTY Expiration Date:02/21/17 Approval Date:02/05/15 Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category Roofing Sub-Category: Asphalt Shingles Materials: Laminate Deck Tyne: Wood SCOPE This approves GAF Timberline HD®,Timberline Natural Shadow®,and Timberline American Harvest' Shingles as manufactured by GAF as described in Section 2 of this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications GAF Timberline HD® 13 1/4"x 39 3/8 " TAS 110 Fiberglass reinforced heavy weight asphalt Manufacturing roof shingle,with a laminate profile Locations#1,2,3,4,5,6,7 GAF Timberline Natural 13 V;x 39 3/8 " TAS 110 Fiberglass reinforced heavy weight asphalt Shadow roof shingle,with a laminate profile Manufacturing Locations#1,2,3,4,5,6,7 GAF Timberline American 13 '14"x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt Harvest® roof shingle,with a laminate profile Manufacturing Locations 92,4,5,6 MANUFACTURING LOCATION 1. Tampa,FL 2. Michigan City,IN 3. Baltimore,MD 4. Myerstown,PA 5. Ennis,TX 6. Tuscaloosa,AL 7. Dallas,TX NOA No.: 14-1022.20 MIAMI-DADE COUNTY Expiration Date:02/21/17 Approval Date:02/05/15 Page 2 of 6 } EVIDENCE SUBMITTED Test AEencv Test Identifier Test Name/Renort Date Underwriters Laboratories,Inc. ASTM D3462 1ICA48924 10/24/11 Underwriters Laboratories,Inc ASTM D3462 IOCA21994 04/22/11 Underwriters Laboratories,Inc ASTM D3462 IOCA28717 07/26/11 Underwriters Laboratories,Inc. ASTM D3462 05CA47541 11/10/06 Underwriters Laboratories,Inc. ASTM D3462 06CA31580 11/30/06 PRI Asphalt Technologies,Inc. ASTM D3462 GAF-101-02-02 11/02/05 Underwriters Laboratories,Inc. ASTM D3462 06NK05159 08/09/06 PRI Asphalt Technologies,Inc. ASTM D3462 GAF-098-02-02 11/08/05 Underwriters Laboratories,Inc. ASTM D3462 02NK41809 08/11/02 Underwriters Laboratories,Inc. ASTM D3462 03NK26444 10/17/03 Center for Applied Engineering ASTM D3462 257989 05/13/97 Underwriters Laboratories,Inc. TAS 107 OINK 45803 04/13/94 Underwriters Laboratories,Inc. TAS 107 06NK05159 08/09/06 Underwriters Laboratories,Inc. TAS 107 o4NK04273 02/20/04 Underwriters Laboratories,Inc. TAS 107 05CA42840 11/11/05 Underwriters Laboratories,Inc. TAS 107 02NK41811 11/11/02 Underwriters Laboratories,Inc. TAS 107 03CA35209 10/17/03 Underwriters Laboratories,Inc. TAS 107 04CA13850 08/30/04 Center for Applied Engineering TAS 100 257989 04/01/97 PRI Asphalt Technologies,Inc. TAS 100 GAF-044-02-01 01/13/04 PRI Asphalt Technologies,Inc. TAS 100 GAF-098-02-01 11/08/05 PRI Asphalt Technologies,Inc. TAS 100 GAF-101-02-01 11/09/05 PRI Asphalt Technologies,Inc. TAS 100 GAF-1.16-02-02 03/23/06 PRI Asphalt Technologies,Inc. TAS-100 ELK-083-02-01 10/16/02 ELK-0,84-02-01 10/15/02 ELK-085-02-01 10/14/02 ELK-086-02-01 10/24/02 ELK-087-02-01 10/21/02 ELK-088-02-01 10/16/02 ELK-107-02-01 10/09/03 ELK-108-02-01 10/09/03 ELK-109-02-01 10/09/03 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.: 14-1022.20 MIAWDAoe coutvrY 11 Expiration Date:02/21/17 Approval Date:02/05/15 Page 3 of 6 INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail'A', attached. 5. Nailing shall be in compliance with Detail B',attached. LABELING Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY BUILDING PERMIT REQmEMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. I ti NOA No.: 14-1022.20 MuaHi•o�e counmr Expiration Date:02/21/17. Approval Date:02/05/15 -Page 4 of 6 Y DETAIL A COURSE LAYOUT DECK FULL 5th 17'OFF 4th 11"OFF 3rd 6"OFF 2nd FULL 1 st NOA No.: 14-1022.20 MIAMI-DADE COUNTY Expiration Date:02/21/17 Approval Date:02/05/15 Page 5 of 6 1 , DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN 39-3/811 (1 m) 14-10-17-1/2" 14-1/2"-17-1/2" (368-445mm) (368-445mm) ail guide line =9-1 6-112-"-9-1'/2" s-afa•-6-114"(185.241mm) (165-241mm) (146mm-159mm) 337mm) 12' z u2• from bottom of shingle (13-84 elf seal adhesive on back ENHANCED NAILING PATTERN -six nails per shingle* required by some local codes and required for enhanced wind coverage on certain products. See limited warranty for details. These shingles MUST be nailed a nominal 6"(152mm)from bottom of of shingle, above the cut outs, as shown. Nails must notibe exposed. END OF THIS ACCEPTANCE NOA No.: 14-1022.20 MIAMI-DARE COUNTY Expiration Date:02/21/17 Approval Date:02/05/15 Page 6 of 6