HomeMy WebLinkAboutProduct Approval Florida Bundling Code Online RECEIF*91 Po 9j 'jP' Y Page 1 of2
RECER"I-D JAN 10 7-1.7
SCIS-Home I Log In I User Registration I Hot Topics Submit Surcharge i Stats 6 Facts Publications I FBC Staff I BCIS Site Flap ( Links I Search
a
a
Product Approval
USt:R':Public user
t
Product Approval Menu>Product or Application Search>Anplicatlon List>AppOcation Detail
•M - I{ FL Jk FL10626-1112
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived: ❑
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany,NJ 07054
(973)872-4421
lindarelth@trinityerd.com
Authorized Signature Beth McSorley
lindareith@trinityerd.com
Technical Representative Beth McSortey(current)
Address/Phone/Email 1 Campus Drive
Parsippany,NJ 07054
(973)872-4421
bmcsorley@gaf.com
Quality Assurance Representative
Address/Phone/Em a i Ii
Category Roofing
Subcategory U'nderlayments
Compliance Method, Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
2 Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 11/12/2017
Validated By John W.Knezevich,PE
2 Validation Checklist-Hardcopy Received
Certificate of Independence FL10626 R12 COI 2015 01 COI Nieminen.odf
Referenced:Standard and Year(of Standard) Standard Year
ASTM D1970 2009
ASTM D6164 2005
ASTM D6757 2007
FM 4474 2004
FRSA/TRI April 2012(04-12) 2012
TAS 103 1995
Equivalence of Product Standards
Certified By
ln,ttp://www-floridabuil'ding.org/pr/pr_app_dtl.aspx?parafn=wGE V XQwtDgtBN bEY5 VD/D2... 9/21/2016
Florida Builiding Code Online Page 2 of 2,
Sections from the Code
Product Approval Method Method I Optionb
Date Submitted 03/31/20.15
Date Validated 04/08/2015
Date Pending FBC Approval 04/12/2015
Date Approved' 06/23/2015
Summary of Products
JFL# Model,Number or Name Description
110626.1 GAF Roof Underlayments Roofing underlayments for use in sloped roof systems
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10626 R12 II 2015 03 FINAL ER GAF Underlavments FL10626-
Approved for use outside HVHZ:Yes R12.Ddf
Impact Resistant:N/A Verified By:Robert Nieminen PE-59166
Design Pressure:+N/A/-45.0 Created by Independent Third Party:Yes
Other:1.)The design pressure noted In this Evaluation Reports
application rel'ates•to one particular underlayment FLI0626 R12 AE 2015 03 FINAL ER GAF Underlavments FL10626-
systerry for use under foam-on tile systems.Refer R12.Ddf
!to,ER Section 5.6.4 for details.2.)Refer to ER Created by independent Third Party:Yes
Section,5 for other Limits of Use.
Back Next,
Contact Us::2601 Blair Stone Road.Tallahassee Fl.32399 Phone:050-487-1824
The State of Florida is an AA/EEO employer.Coovrloht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail,to this entity.Instead,contact the office by phone or by traditional mail If you have any questions,please contact 850.487.1395.*Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one-The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 45S,F.S.,please click here.
Product Approval Accepts:
® ettee4'�'
Credit Card
Safe
http,://www-,loridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2... 9/21/2016
EXTERIOR RESEARCH&DESIGN, LLC.
Certificate of Authorization#9503
TOR IWry ER� 353 CHRISTIAN STREET, UNIT 413
C OXFORD, Cr 06478
PHONE:(203) 262-9245
FAX:(203) 262-9243
EVALUATION REPORT
GAF Evaluation Report 01506.04.08-1112
Kannpus Drive FL10626-1112
Parsippany,N11 07054 Date of Issuance:04025/2008
Revision 12:03/31/2015
SCOPE:
This, Evalluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida..The documentation submitted has been reviewed by Robert Nieminen,
P.E.. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 51h Edition (2014) Florida Building Code
sections,noted herein.
DESCRIPTION. GAF Roof U'nderlayments
LABELING. Labeling shalt be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quallity Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes orthe referenced Quality Assurance documentation changes. Trinityl ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADvERTISEMENY.The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising,literature. If any portionn of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPEMON.Upson:request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
Its distributors and shalt be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages,l through 8.
Prepared by.
,,.tidsstiEarnrry�
Robertl.M.Wberninenr P.E. The facsimile seal appearing was authorized byRobert Nieminen,
P.E.on 03/31/2015.This does not serve as an electronically signed
F1'orid'a R'egistradian,No.59166,Florida LICA ANE1983 ���� document.signed,sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATIOMOF INDEPENDENCE:
I., TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. TrinityllER,DI is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
1. Robert Nieminen,P.E.does not have nor will,acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Niemninen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product..
5.. This is.a building code evaluation. Neither Trinityl,ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on wlhfch.this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specificall rfo>rthat purpose.
TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE.
Product Category: Roofing
Sub-Category: Und'erl'ayment
Compfiance Statement: GAF Roof Underfayments, as produced by GAF, have demonstrated compliance with the following
section6 of the FI'oridal B'uil'ding.Code through testing in accordance with the following Standards. Compliance is subject to the
Instal'Ibtion Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Uplift FM 4474 2004
1507.2.41 1507.2.9:2,1507.5.3, Physical Properties ASTM D1970 2009
1507..7.3,
1507.2.3 Physical Properties ASTM D6757 2007
1507.11.2 Physical Properties ASTM D6164 2005
152316.5.2.1 PhysicalProperties TAS 103 1995
1507.33 Installation Practice FRSA/TRI April 2012(04-12) 2012
3. REFERENCES:
Entity Examination Reference Date
ERD(TST 6049) Physical Properties. G12210.06.09 08/03/2009
ERD,(TST 60'4% Physical'Properties 634150.08.11 11/14/2011
ERD(;TST 6049). Physical Properties G40630.01.14-2B 01/07/2014
ERD(TST 6049$ Physical!Properties G46160SC 04/14/2014
PRI(TST 5878)! Physical properties GAF-026-02-01 03/26/2002
PW(TST 5878): Physical properties GAF-027-02-01 03/26/2002
PRI(TST 5878) Physical properties GAF-042-02-02 03/12/2004
PRIi(TST 5878)'• Physical'properties GAF-042-02-01 06/03/2005
PRI(TST3878): Physical properties GAF-154-02-01 02/06/2007
PRIi(TST'5878) Physical properties RGM-023-02-01 02/09/2007
PRI'(TST 5878) Physical properties ELK-311-02-01 09/11/2007
PRI(TST'5878)'• Physical properties GAF-238-02-01 03/03/2010
PRP(TST S878), Physical,properties GAF-275-02-01 11/11/2010
PRI(TST 5878) Physical'properties GAF-349-02-03 06/19/2012
PRI'(TST 58781 Wind Uplift GAF-434-02-01 09/16/2013
PRI!(TST 5878)' Wind Uplift GAF-434-02-03 09/16/2013
PRI(TST 58.78)- Wind Uplift GAF-434-02-04 09/16/2013
ITS,(TST I509p Physical properties 3077464-002 09/14/2005
ITS.(!TST150% Physical properties 3077464-02 01/09/2006
Ut(TST 1740)! Physical properties 02NK22569 06/04/2002
UL(TST 1740) Physical properties IONK11990 05/18/2011
Miami�Dade(.CER1592)' HVHZcompliance 13-1104.05 02/20/2014
Miami,Dade(CER1592)1 HVHZcompliance 13-1104.11 03/06/2014
Miami-Dade(CER 1592)'. HVHZcompliance 14-1022.26 02/05/2015
ICC-ES(EVL2396) IBC compliance ESR-1322 01/01/2014
UL,LLC.(QUA 9625)• Quality Control Inspect,File R10689,Stockton,CA 11/12/2014
UL,LLC.(QUA 9625) Quality Control Inspect,File R10689,Hickory,NC 03/04/2015
UL,.LLC.(QUA 9625) Quality Control Inspect,File R10689,Mt.Vernon,IN 01/16/2015
UL,.LLC.(QUA 9625) Quality Control Inspect,File R10689,Pryor,OK 02/05/2015
4. PRODUCT DESCRIPTION:
4.1 Self-Adhering Underlavments:
4.1.1 Liberty"SBS Self-Adhering Base/Ply Sheet is a smooth-surfaced,fiberglass-reinforced,self-adhering SBS modified
bitumen roof underfayment.
4.1.2 StornaGuard®Film Surfaced Leak Barrier is a film-surfaced,fiberglass-reinforced,self-adhering SBS modified bitumen
roof underfayment. StormGuard® Film Surfaced Leak Barrier is also used as a secondary water barrier to seal roof
decks.
Exterior Research and Design,LEC. Evaluation Report 01506.04.08-R12
Certiftote afAuthorizotion#9SO3 F1.10626-1112
Revision 12:03/31/2015
Page 2 of 8
TRINITIP I ERD
4..1.3 UnderRoof'"2 Polyester-Surfaced Leak Barrier is a spun-bond-glass-reinforced-polyester-mat-surfaced,composite-
reinforced,S&S-self-adhering modified bitumen roof underlayment.
411.4 UnderRoofr"HT High Temperature Leak Barrier is a polyester-mat-surfaced,fiberglass-reinforced,self-adhering SBS
modified bitumen roof underlayment.
4.1.5 a mineral-surfaced, fiberglass-reinforced, self-adhering SBS
modified bitumen roof underlayment. WeatherWatch" Mineral Surfaced Leak Barrier is also used as a secondary
water barrier to,sea[roof decks.
4.1.6 WeatherWatch" XT Mat Surfaced Leak Barrier is a coated-mat-surfaced, fiberglass-reinforced, self-adhering SBS
modified bitumen roof underlayment.
4.2 Mechanfcal[y Fastened Underfavments:
4.2-1 VersaShfeld"Ffre-Resistant Roof Deck Protection is a non asphahic,fiberglass-based roof underlayment and/or fire
barrier.-
4.3 Asphalt-Applied Underfavments:
4.3-1 Ruberoid" Map Granule is a granule-surfaced, polyester-reinforced, asphalt-applied SBS modified bitumen roof
und'erl'ayment.
4.3.2Ruberoid° Mop Granule FR (formerly RuberoldO Mop 170 FR) is a granule-surfaced, polyester-reinforced, asphalt-
applied SBS modified bitumen roof underlayment.
5. LIMt'TASfONS:
5.1 This is.a building code evaluation. Neither Trinity[ERD nor Robert Nieminen,P.E.are,in any way,the Designer of
Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2' This Evaluation Report is not for use in the HVHZ.
53 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory or test
report from,accredited testing,agency for fire ratings of this product.
5.4 GAF Roof Underl'ayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this
evaluation combfned with supporting data for the prepared roof covering.
5.5. Allowable roof covers applied atop GAF Roof Underlayments are follows:
'TABLEI:ROOF COVER.OPTIONS -
Und'edayrment Asphalt Nail-On Tice Foam-On Tile Metal Wood Shakes& Slate or
Shingles Shingles 5imulatedSate
VersaShield'Fire-Resistant Yes No No No No No
Roof Deck Protection
Liberty—SBS Self-Adhering
Yes No No No No No
Base/Ply Sheet
StormGuard"Film,Surfaced yes No No Yes No No
Leak Barrier f
Under Roof-2 PolyesterYes-
Surfaced Leak Barrier Yes Yes See 5.5.1 No No Yes
UnderRoof"HT High Yes No No Yes No No
Temperature Leak Barrier
I.-y' Rlli�l� " /nLra "',� �
ISU� �arff i.---
c Vea�Barrrer--
WeatherWatch°XT Mat Yes No No No No No
Surfaced'Leak Barrier
Ruberoid'Mop Granule Yes Yes Yes No Yes Yes
See S.S.I
Ruberoid"Mop Granule FR Yes Yes Yes No Yes Yes
See 5.5.1
Exterior Research.and Design,LLC. Evaluation Report 01506.04.08-R12
Gertif&ate of Authorization#9503 FL10626-R12
Revision 12:03/31/2015
Page 3 of 8
�TRINFIYIERD
5.5.1 "Foam-On Tile"is limited to use of the following unless tensile adhesion/long term aging data from an accredited
testing laboratory is provided.
Underlayment(s) Adhesive Option(s)
j UnderRooP"2 Polyester-Surfaced!Leak Barrier 3M'"2-Component Roof Tile Adhesive AH-160(FL6332)
Ruberoid'Mop Granule;Ruberoid®Mop Granule FR Dow TIIeBond(FL717)
5.6 Allowable substrates are noted below:
;.t�SATC:`� Liberty'" SBS Self-Adhering Base/Ply Sheet; StormGuard" Film Surfaced Leak Barrier; UnderRooP" 2 Polyester-
Surfaced Leak Barrier: Und'erR'oof" HT High Temperature Leak Barrier; ?letherW_atm°-M1%Iifie_ralrS_iiifaped leak'?
4 Barftand WeatherWatch°XT Mat Surfaced Leak Barrier,Self-Adhered to Deck:
D New untreated plywood;
D Existing,untreated ASTM D41 primed plywood.
R'uberofd'Mop Granule and Ruberoid°Mop Granule FR,Asphalt-Applied to Deck:
Y ASTM D41 primed structural concrete.
5.6.2 Liberty- SBS Self-Adhering Base/Pty Sheet; StormGuard' Film Surfaced Leak Barrier; UnderRooP" 2 Polyester-
Surfaced Leak Barrier; UnderRooP" HT High Temperature Leak Barrier; WeatherWatch' Mineral Surfaced Leak
Barrier and WeatherWatch® XT Mat Surfaced Leak Barrier, Self-Adhered to Mechanically Attached Base
Underlayrnent:
Y ASTM;D226,Type R felt.
➢ StormSafe'"Anchor Sheet
Ruberoid' Mop Granule and Ruberoid® Mop Granule FR, Asphalt-Applied to Mechanically Attached Base
Underlavment:
➢ GAFGLAS'#80 Ultima'"Base Sheet;
➢ Ruberoid®20 Smooth.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam-on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012(04-12)or as detailed below.
5.6.3 Bondi to Other Substrate Types:
➢ ASTM D41 primed metal(flashing metal,valley metal,etc.)
5.6•.4 Wind Resistance for Underlayrnent Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam-on file systems,where the underlayment
forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRT April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for
determination of design wind loads.
5.6.4.1 Maximum Design Pressure=-45 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optionall)ASTM D41
Underiayment: UnderRooP"2 Polyester-Surfaced Leak Barrier,self-adhered
5.6,4.2 Maximum Design Pressure=-45 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: GAFGLAS°#80 Ultima"Base Sheet or Ruberoid®20 Smooth mechanically attached with 12 ga.,min.
1.25-inch long ring shank nails through 32 ga.,1-5/8 inch diameter tin caps spaced 9-inch o.c.at the
4-inch wide side laps and 9-inch o.c.at two(2),equally spaced,staggered center in the field of the
sheet.
Top Layer: Ruberoid°Mop Granule or Ruberoid'Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 lbs/square.
Exterior Research.and Design,LCC. Evaluation Report 01506.04.08-R32
Certificate of Authorization#9503 FL10626-R12
Revision 12.03/31/2015
Page 4 of 8
TRINITY ERD
5.6.4.3 Maximum:Design Pressure=-45 psf.
Deck: Min.19132-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: GAFGLAS°tf80 Ultima`"Base Sheet or Ruberoid°20 Smooth mechanically attached with 12 ga.,min.
1.25-inch long ring shank nails through 32 ga.,1-5/8 inch diameter tin caps spaced 8-inch o.c.at the
4-inch wide side[laps and 8-inch o.c.at three(3),equally spaced,staggered center in the field of the
sheet.
Top,Layer: Ruberoid°Mop Granule or Ruberoid°Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 lbs/square.
5.7 Exposure Limitations:
5.7.1 Liberty" SBS Self-Adhering Base/Ply Sheet; StormGuard" Film Surfaced Leak Barrier; UnderRoof"" HT High
Temperature.Leak Barrier;WeatherWatch"Mineral Surfaced Leak Barrier and WeatherWatch°XT Mat Surfaced Leak
Barrier shall not be left exposed for longer than 30-days after installation.
5.7.2 VersaShiel'd" Fire-Resistant Roof Deck Protection, UnderRoof" 2 Polyester-Surfaced Leak Barrier, Ruberoid" Mop
Granufe and Ruberoid®Mop Granule FR shall not be left exposed for longer than 180-days after installation-
& INSTALLATION:
6.1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to the
Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Install'self-adhering und'erlayments when ambient temperatures are minimum 45"F and rising.
6.4 All metal surfaces shall'be primed with Matrix"307 Premium Asphalt Primer or alternate GAF accepted ASTM D41
primer prior to application of self-adhering membranes.
6.5 VersaShield®Fire-Resistant Roof Deck Protection:
6.5.1 fnstalU VersaShietd" Fire-Resistant Roof Deck Protection in compliance with manufacturer's published installation
instructions and the requirements for ASTM D6757 underlayment in FBC Section 1507.2.3 for the type of prepared
roof covering to be installed. A double layer is required for 2:12<roof slope<4:12. No hammer tacks'or staples are
permitted.
6.5.2 Optional,or if required by the Authority Having Jurisdiction: Install a leak barrier of Liberty" SBS Self-Adhering
Base/Ply Sheet; StormGuard" Film Surfaced Leak Barrier; UnderRoof" 2 Polyester-Surfaced Leak Barrier;
UhderR'oof" HT High Temperature Leak Barrier; WeatherWatch° Mineral Surfaced or WeatherWatchm XT Mat
Surfaced Leak Barrier at vulnerable leak areas, including but not limited to eaves, valleys, rakes, skylights and
dormers. At eaves and valleys,install the leak barrier prior to installation of the underlayment. Along the rake,
install' the underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the
und'erl'ayment and exposed decking. At other areas,install the leak barrier over the underlayment.
6:6 Liberty"SBS Self-Adhering Base/Ply Sheet:
6.6.1 lbstalll Liberty`" SBS Self-Adhering Base/Ply Sheet in compliance with manufacturer's published installation
instructions and the requirements for ASTM D1970 underlayments,in FBC Sections 1507 for the type of prepared roof
covering to be installed.
6.6.2 The minimum and maximum roof slopes are%::12 and 6:12,respectively. Back-nailing is required when slope is 1:12
or greater. Back-nailing shall consist of minimum 1-inch square or round cap nails spaced 18"o.c.within 3-inch side
Zaps.
6.6.3 For non-tile applications,direct to deck:
For direct-bond to deck applications plywood shall be primed with Matrix'"307 Premium Asphalt Primer or alternate
GAF accepted ASTM D41 primer at%to Y4 gallon per square.
Prior W removal of release film,align sheets property starting at the low-point of the roof(eave)with the selvage
edge upstope and for minimum 2-inch overhang at eaves and rakes. Roll out sheet and allow to'relax'for min. 30
minutes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2-inch over the
eave and nail!into place 12"o.c. Remove the top piece of release film and bond to substrate. Install primed drip
edge and fasten to meet FBC Chapter 16 wind toad requirements. Install 1/8-inch troweling of Matrix'"201 Premium
SBS Flashing Cement over drip edge..
Exterior Research and Design,LLC. Evaluation Report 01506.04.08-R32
Certificate,of Authorization#9503 FL10626-R12
Revision 12:03/31/2015
Page 5 of 8
�TRINIWIERD
Continue upsl'ope in a similar manner,maintaining minimum 3-inch side-laps and minimum 6-inch end-laps. Ensure
alll end laps are staggered at Feast 18-inch apart.
Use a weighted!Dawn or l'inol'eum roller to ensure complete adhesion to the substrate. Use a hand roller to firmly
bond side,acrd end;laps.
6.6.4 For non-tile applications,to mechanically attached anchor sheet:
Install,ASTM D226,Type 11 felt in accordance with codified requirements or StormSafe'"Anchor Sheet in accordance
with Section 6.6.
Install Liberty"SBS Self-Adhering Base/Ply Sheet over the mechanically attached anchor sheet as noted above.
6.7 StormGuard®Film Surfaced Leak Barrier:
6.7.1 Instal[StormGuard®Film Surfaced Leak Barrier in compliance with manufacturer's published installation instructions
and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to
be instalfed.
6=7.2 Back-nailing is required. Back-nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c.
within 3-inch side laps.
6.7.3 For non-tile applications,direct to deck:
Prior to removal of release film,align sheets properly starting at the low-point of the roof(eave)with the selvage
edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and
bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12"o.c. Remove the top piece of
release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load
requirements, install 1/8-fnch troweling of Matrix"201 Premium SBS Flashing Cement over drip edge.
Continue upsl'ope in a similar manner,maintaining minimum 3-inch side-laps and minimum 6-inch end-laps. Ensure
all!end laps are staggered at least 18-inch apart.
Use a hand roller to firmly bond side and end laps.
6.7-4 For non-tile applications,to mechanically attached anchor sheet:
Install ASTMi D226,Type It felt in accordance with codified requirements or StormSafe'"Anchor Sheet in accordance
with Section:G.G.
Install StormGuard®Film Surfaced Leak Barrier over the mechanically attached anchor sheet as noted above.
6.S U'nderRoof—2 Polyester-Surfaced Leak Barrier:
6.9.1 Install UnderRoof" 2 Polyester-Surfaced Leak Barrier in compliance with manufacturer's published installation
instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof
covering to be installed.
6,.&Z The minimum and maximum roof slopes are 2:12 and 12:12,respectively. Back-nailing is required when slope is 4:12
or greater. Back-nailing shall:consist of minimum 1-inch square or round cap nails spaced 12"o.c.within 4-inch side
laps.
6.8.3, For tile roof i'nstall'ations:
Reference is made to FRSA/TRI April 2012 (04-12) installation Manual and Table 1 herein, using the instructions
noted herein as a guideline. Tile shall be loaded and staged in a manner that prevents the slippage and/or damage to
the und'erlayment.
6.8.4 For non-tile applications,direct to deck:
Prior to removal of release film,align sheets properly starting at the low-point of the roof(eave)with the selvage
edge upsl'ope and for minimum 2'-inch overhang at eaves and rakes. Remove the lower piece of release film and
bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12"o.c. Remove the top piece of
release film and bond to substrate. install, primed drip edge and fasten to meet FBC Chapter 16 wind load
requirements. Install 1/8-inch troweling of Matrix'"201 Premium SBS Flashing Cement over drip edge.
Continue upsl'ope in a similar manner,maintaining minimum 4-inch side-laps and minimum 6-inch end-laps. Ensure
all:ends laps are staggered at least 3-feet apart. End laps shall be sealed with a 1/16`h to 1/8th inch thick trowel
application of Matrix'"201 Premium SBS Flashing Cement.
Use a hand roller to firmly bond side and end laps.
Exterior Research and Design,CLC. Evaluation Report 01506.04.08-1112
Certificate of Aitthorization.#9503 FL10626-R12
Revision 12:03/31/2015
Page 6 of 8
TRINITY I ERD
6:8'.5, For nom-tile applications,to mechanically attached anchor sheet:
Install'ASTMi 13,226,Type 111 felt in accordance with codified requirements or StormSafe'"Anchor Sheet in accordance
with Section 6.6.
Install UnderRoof'"2 Polyester-Surfaced Leak Barrier over the mechanically attached anchor sheet as noted above.
6.9 UnderRoof'"HT High Temperature Leak Barrier:
6.9'.1 Install! UnderRoof'"' HT High Temperature Leak Barrier in compliance with manufacturer's published installation
instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof
covering.to be Installed-
6.9`.2 The minimum and maximum roof slopes are 1:12 and 12:12,respectively. Back-nailing is required when slope is 4:12
or greater. Back-nailing shall consist of minimum 1-inch square or round cap nails spaced 12"o.c.within 4-inch side
laps.
6.913 For non-tile applications,direct to deck:
Prior to removal of release film, align sheets properly starting at the low-point of the roof(eave)with the selvage
edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and
bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12"o.c. Remove the top piece of
release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load
requirements. Install 1/8-inch troweling of TopCoat°FlexSeal"Caulk Grade over drip edge.
Continue upsl'ope in a similar manner,maintaining minimum 4-inch side-taps and minimum 6-inch end-laps. Ensure
all:endlaps are staggered at least 3-feet apart.
Use a hand rollerto firmly bond side and end laps.
6.9'.4 For non-tife applications,to mechanically attached anchor sheet:
I'nstaff ASTM D226,Type 11 felt in accordance with codified requirements or StormSafe'"Anchor Sheet in accordance
with Section 6.7.
Install UnderRoof"HT High Temperature Leak Barrier over the mechanically attached anchor sheet as noted above.
C �Vlfea2frerWatdt°jMi2rtaat SurfacediLeak Barcierao-r WeaffidOAtat'cri°"FC VMIt'Surfaced CealrBarrier.___,'_
6101..1 fnstafli WeatherWatch®Mineral Surfaced Leak Barrier or WeatherWatch®XT Mat Surfaced Leak Barrier in compliance
with,manufacturer's published installation instructions and the requirements for ASTM D1970 underlayments in FBC
Sections 1507 for the type of prepared roof covering to be installed.
6.19,.2' WeatherWatch° Mineral Surfaced Leak Barrier may be installed as a secondary water barrier using minimum 4-inch
wide rolls to seat plywood deck joints prior to installation of the primary underlayment system.
6-_10'.3 Back-nailing is required. Back-nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c.
within 4-inch side laps.
6.1014 For non�-til'e applications,direct to deck:
Prior to removal of release film, align sheets properly starting at the low-point of the roof(eave)with the selvage
edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and
bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12"o.c. Remove the top piece of
release film and bond to substrate. install primed drip edge and fasten to meet FBC Chapter 16 wind load
requirements. install 1/8Anch troweling of Matrix'"201 Premium SBS Flashing Cement over drip edge.
Continuer upsl'ope in a similar manner,maintaining minimum 3-inch side-laps and minimum 6-inch end-laps. Ensure
all end laps are staggered at least 18-feet apart.
Use a hand roller to firmly bond side and end laps.
6.10.5 For non,tile applications,to mechanically attached anchor sheet:
Install ASTM D226,Type ill felt in accordance with codified requirements or StormSafe"Anchor Sheet in accordance
with Section 6.6.
Install WeatherWatch Minerall Surfaced Leak Barrier or WeatherWatch® XT Mat Surfaced Leak Barrier over the
mechanicallyr attached anchor sheet as noted above.
Exterior Reseaach and Design,I.I.C. Evaluation Report 01506.4.08-1132
Certificate of Avthoriiation•#9503 FL30626-R12
Revision 12:03/31/2015
Page 7 of 8
��TRINFYIERD
6.11. Ruberol&'Mop Granule:Ruberoid®Mop Granule FR:
6.111.1 Shall' be installed in compliance with current GAF published installation requirements, subject to the limitations
herein.
6.11.2 Non-Tile Applications:
6.11.2_1 Fully adhere in ASTM D312,Type IV hot-asphalt to the substrates noted in Section 5.5. Side laps shall be minimum 4-
inch and end-laps minimum 6-inch wide,and offset end-laps minimum 3-feet from course to course. Side and end-
I'aps•shall be fully adhered.in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch
beyond the lap edge. Consult GAF instructions regarding back-nailing requirements.
6.11.3' Tile Applications:
6.11.3.1 Refer to FRSA/TRI1 April 2012(04-12)Installation Manual and Tabre 1 herein.
6.11.3L2 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment_
7.• BUTLOP=PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8.. MANUFACTURING PLANTS:
Contactthe manufacturer or the named QA entityfor information on plants covered under Rule 61G20-3 CA requirements.
9. QuALiTB ASSURANCE ENTNTy:
UL,LLC..—QU'A9625;(847)664-3281
END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 01506.04.08-1112
Certificate-of Atrthorizatiorr#9503 FL10626-R12
Revision 12:03/31/201S
Page 8 of 8