Loading...
HomeMy WebLinkAboutProduct Approval (2) RECEIb'rD 3 A 15 7;iI117 _ ��{� r" - NIIANII-DADS COUNTY MIA►ft�1'D_ADE_, B� PRODUCT CONTROL SECTION aitf, I J�, 11805 SW 26 Street_ [Zoom 209 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami.Florida 33175-2,17,1 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 P(796)315-2599 NOTICE OF ACCEPTANCE (NOA) GAF I Campus Drive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use 01'c011shuction materials.The documentation submitted has been reviewed and accepted by Mianli-Dade County RER - Product Control Section to he used Ill Miami Dade Count)and other areas where allowed by the Authority I-laving Jurisdiction (AI-1.1). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AM (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material tails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AI-1J nlay immediately revoke, modify, or suspend the use ol'such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this produce or material flails to meet the requirements of the applicable building code. "this product is approved as described herein, and has been designed to comply with the Florida Building Code including the Nigh Velocity I-lurricane Zone of the Florida Building Code. DESCRIPTION: C`AF nuberline MD";Timberline Natural Shadow0',and Timberline American Harvest"" Shingles LABELING: Each unit shall beat'it pernianellt label with the manufacturer's name or logo, city,state and lollowing statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur afler the expiration date or if there has been a revision or change in the materials, use, and/or I11anulacture of the product or process. Misuse of this NOA as an endorsement of any product., for sales,advertising orally other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal oMOA. ADVERTISEMENT: The NOA number preceded by the words Mianli-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in Its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 13-0419.04 and consists of pages I through 6. The submitted documentation was reviewed by Juan E. Collao, R.A. NOA No.: 14-1022.20 CMIAMI-MDADEMOUMNTY I Expiration Date: 02/21/17 Approval Date: 02/05/15 Pate I of 6 Z ROOFING ASSEMBLY APPROVAL Cateyory: Roofing Sub-Category Asphalt Shingles Materials: Laminate Deck Tyne: Wood SCOPE This approves GAF Timberline NDU",Timberline Natural Shadow'>',and Timberline American Hai-vest"`" Shingles as manufactured by GAF as described in Section 2 of this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description SI)ecilications .jA TiiirlrefIric ff9 "�- 13 '41"x 39'/8 TAS 110 Fiberglass reinforced heavy weight asplialt Maniffi taring roof shingle, with a laminate proftic Locations#1,2,3,4,5,6,7 GAF Timberline Natural 13 I/.} x 39;/K TAS 110 Fiberglass reinforced heavy weight asplialt Shadow"' roof shingle, with a laminate profile Man q fact uring Localisms#1,2,3,4,5,6,7 GAF Timberline American 13 I/.I..Y 39'/H TAS 110 Fiberglass reinforced heavy weight asphalt Harvese' roof shingle, with a laminate profile Ntam?Aicluring Locations#2,4,5,6 MANUFACTURING LOCATION 1. Tampa, FL, 2. Michigan City, IN 3. Baltimore, MD 4. Myerstown, PA 5. Ennis,TX 6. Tuscaloosa, AL 7. Dallas,TX MIAMI•DADE COUNTY NOA No.: 14-1022.20 �muu, i Lxpiration Date: 02/21/17 Approval Date: 02/05/15 Page 2 of 6 EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories, Inc. ASTM D3462 I ICA48924 10/2411 I Underwriters Laboratories, Inc ASTM D3462 IOCA21994 04/22/1 ) Underwriters Laboratories, ine ASTM D3462 IOCA28717 07126/11 Underwriters Laboratories, file. ASTM D3462 05CA47541 11/10/06 Underwriters Laboratories, [tic. ASTM D3462 06CA31580 11/30/06 PRI Asphalt Technologies, [tic. ASTM D3462 GAF-101-02-02 11/02/05 Underwriters Laboratories, Inc. ASTM D3462 06NK05IS9 08/09/06 PRI AsphaltTechnologies, Inc. AS"I M D3462 GAF-098-02-02 11/08/05 Underwriters Laboratories, Inc. ASTM D3462 02NK41809 09/11/02 Underwriters Laboratories, Inc. ASTM D3462 03N.K26444 10/17/03 Center for Applied Engineering ASTM D3462 257989 05/13/97 Underwriters Laboratories, Inc. TAS 107 OINK45803 04/13/94 Underwriters Laboratories, Inc. TAS 107 06NK05159 08/09/06 Underwriters Laboratories, Inc. TAS 107 04NK04273 02/20/04 Underwriters Laboratories, Inc. TAS 107 05CA42840 1 1/1 1/05 Underwriters Laboratories, Inc. TAS 107 02N K4181 1 1 1/1 1/02 Underwriters Laboratories, ]tic. TAS 107 03CA35209 10/17/03 Underwriters Laboratories, Inc. TAS 107 04CA 13850 08/30/04 Center for Applied Engineering TAS 100 257989 04101/97 PRI Asphalt Technologies, Inc. TAS 100 GAF-044-OZ-01 0I113/04 PRI Asphalt Technologies, Inc. 'rAS 100 GAF-098-02-01 11/08/05 PRI Asphalt Technologies, Inc. TAS 100 GAF-101-02-01 11/09/05 PRI Asphalt Technologies, Inc. TAS 100 GAF-I 16-02-02 03/23/06 PRI Asphalt Technologies, [tie. TAS-100 ELK-083-02-01 10/16/02 ELK-084-02-01 10/15/02 ELIC-085-02-01 10/14/02 ELIC-086-02-01 10/24/02 ELK-087-02-01 10/21/02 ELK-088-02-01 10/16/02 ELK-107-02-01 10/09/03 ELK-108-02-01 10/09/03 ELK-109-02-01 10/09/03 LIMITATIONS I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory 161- fire orfire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rulc 61G20-3 of the Florida Administrative Code. MIAMI•DADE COUNTY NOA No.: 14-1022.20 Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 3 of 6 INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail 'A', attached. 5. Nailing shall be in compliance with Detail 'B',attached. LABELING Shingles shall bear the imprint or identifiable marking of' the manufacturer's name or logo, city and state of manufacturing facility, and following statement; "Miami-Dade County Product Cont►•ol Approved" or the Miami-Dade County Product Control Seal as shown below. QM1AMi-DMADEMC0=UNTY � e BUILDING PERMIT REQUIREMENTS 1. Application.for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 14-1022.20 MIAMI•DADECOUNTY Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 4 of 6 DETAIL A COURSE LAYOUT DECK FULL 5th 17"OFF 4th 11 OFF 3rd 6" OFF 2nd FULL 1 st :m OUNTY NOA No.: 14-1022.20 flullsyloNTY Expiration Date: 02/21117 Approval Date:02/05/15 Page 5 or 6 DETAIL B OVERALL.DIMENSIONS AND NAILING PATTERN 39-318" (1rn} �— 14-1/2"-17-1/2" —*► 14-1/2"-17-112" (368-445mm) (368-445mm) ail guide line 6-1/2"-9-1/2" t} 6-1/2"-9-1/2" 13;,1 J ty�s-2,tnmy ties-241m"> 5-3t4"-6-1M" 7nmq —+! _ _ _ (146mm-159mm) 03;04 from bottom of shingle 71 Self seal adhesive on back ENHANCED NAILING PATTERN - six nails per shingle* required by some focal codes and required for enhanced wind coverage on certain products. See limited warranty for details. These shingles MUST be nailed a nominal 6" (152mm)from bottom of of shingle, above the cut outs, as shown. Nails must not be exposed. END OF THIS ACCEPTANCE NOA No.: 14-1022.20 MI MI•DADE COUNTY �Wa...loll Expiration Date: 02/21/17 Approval Date: 02/05/15 Page 6 of 6