HomeMy WebLinkAboutProduct Approval RECEIVED JAN 1 N'17
FIL a NIIANI]-DADE COUNTY
p -:_:v
MIAM MA_MADE= � PRODUCT CONTROL SECTION
11805 SW 26 SU-ect_ Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) M1 4111,i. I'lorida 33175-2174
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 P(786)315-2599
NOTICE OF ACCEPTANCE (NOA)
GAF
1 Campus Drive
Parsippany,N.I 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority I-faving.lurisdiction (AI-1.1).
This NOA shall not be valid alter the expiration date slated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AM (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AI-IJ may immediately
revoke, modify, or suspend the use of such product or material within their.jurisdictioil. RER reserves the right to
revolve this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the 1-f igh Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: (:AF'Timberline I-ID"
,-Timberline Natural Shadow"",and Timberline American Harvest""
Sliing es-"`=
LABELING: Each unit shall bear it permanent label with the manufacturer's name or logo, city,state and lollowing
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of'NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the lob site at:the request of the Building Official.
This NOA revises NOA 13-0419.04 and consists of pages I through 6.
The submitted documentation was reviewed by Juan E. Collao, R.A.
1
7 �
MIAMI•DADECOUNTY NOA No.: I4-1022.20
Expiration Date: 02/21/17
Approval Date: 02/05/15
Page I of 6
ROOFING ASSEMBLY APPROVAL
Catel4ory: Roofing
Sub-Catccfory: Asphalt Shingles
Materials: Laminate
Deck Type: Wood
SCOPE
This approves GAF Timberline 14W',Timberline Natural Shadow", and Timberline American Harvest°`
Shingles as manufactured by GAF as described in Section 2 of this Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
GjkF Timberline l;><,D. 13 ' "x 39'/, TAS 110 Fiberglass reinforced heavy Weight asphalt
land crclur 17; roof shingle, with a laminate profile
Localious#l,2,3,4,5,6,7
GAF Timberline Natural 13 '/,�' x 39'Is" TAS 1 10 Fiberglass reinforced heavy weight asphalt
Shadow'"' roof shingle,with a laminate profile
Alan of act uring
Locations#1,2,3,4,5,6,7
GAF Timberline American 13 '/,i•'x 39'/H' TAS 110 Fiberglass reinforced heavy weight asphalt
Harvest" roof shingle, with a laminate profile
11anufcrclan-ing
Locations#2,4,5,6
MANUFACTURING LOCATION
1. Tampa, FL
2. Michigan City, IN
3. Baltimore, MD
4. Myerstown, PA
5. Canis,TX
6. Tuscaloosa, Al-
7.
L7. Dallas,TX
MIAMI•DADE COUNTY
NOA No.: 14-1022.20
t Expiration Date: 02/21/17
Approval Dale: 02/05/15
Page 2 of 6
EVIDENCE SUBMITTED
Test A14ency Test Identifier Test Name/Report Date
Underwriters Laboratories, inc. ASTM D3462 I ICA48924 10/24/11
Underwriters Laboratories, inc ASTM D3462 l OCA21994 04/22/1 )
Underwriters Laboratories, inc ASTM D3462 l OCA28717 07/26/11
Underwriters Laboratories, Inc. ASTM D3462 05CA47541 11/10/06
Underwriters Laboratories, [ne. ASTM D3462 06CA31580 11/30/06
PRI Asphalt Technologies, Inc. ASTM D3462 GAF-101-02-02 11/02/05
Underwriters Laboratories, Inc. ASTM D3462 06NKOS I S9 08/09/06
PRI Asplialt Technologies, Inc. ASTM D3462 GAF-098-02-02 11/08/05
Underwriters Laboratories, hrc. ASTM D3462 02NK41809 09/11/02
Underwriters Laboratories, [tic. ASTM D3462 03NK26444 10/17/03
Ccnter for Applied Engineering ASTM D3462 257989 05/13/97
Underwriters Laboratories, ine. TAS 107 OiNK45803 04/13/94
Underwriters Laboratories, Inc. TAS 107 OONK05159 08/09/06
Underwriters Laboratories, Inc. TAS 107 04NK04273 02/20/04
Underwriters Laboratories, Inc. TAS 107 05CA42840 1 1/1 1/05
Underwriters Laboratories, ]nc. TAS 107 02NK4181 1 1 1/1 1/02
Underwriters Laboratories, ]tic. TAS 107 03CA35209 10/17/03
Underwriters Laboratories, [tic. TAS 107 -04CA13850 08/30/04
Center for Applied Engineering TAS 100 257989 04/01/97
PRI Asphalt Technologies, inc. TAS 100 GAF-044-02-01 01/13/04
PRI Asphalt Technologies, Inc. TAS 100 GAF-098-02-01 11/08/05
PRI Asphalt Technologies, inc. TAS 100 GAF-101-02-01 11/09/05
PRI Asphalt Technologies, Inc. TAS 100 GAF-I 16-02-02 03/23/06
PRi Asphalt Technologies, [tic. TAS-100 ELK-083-02-01 10/16/02
ELK-084-02-01 10/15/02
ELK-085-02-01 10/14/02
ELK-086-02-01 10/24/02
ELK-087-02-01 10/21/02
ELK-088-02-01 10/16/02
ELK-107-02-01 10/09/03
ELK-108-02-01 10/09/03
ELK-109-02-01 10/09/03
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed ou roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code,
MIAMI-DADE COUNTY
NOA No.: 14-1022.20
•• + i. Expiration Date: 02/21/17
Approval Date: 02/05/15
Page 3 of 6
INSTALLATION
I. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail W, attached.
5. Nailing shall be in compliance with Detail '13', attached.
LABELING
Shingles shall bear the imprint or identifiable marking of' the manufacturer's name or logo, city and state of
manufacturing facility, and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade
County Product Control Seal as shown below.
MIAMI•DADE COUNTY
In j g iam jD
BUILDING PERMIT RE,QUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 14-1022.20
MIAMI•DADECOUNTY Expiration Date: 02/21/17
Approval Date: 02/05/1-5
Page 4 of 6
DTTAIL A
COURSE LAYOUT
DECK
FULL
5th
17" OFF 4th
11" OFF 3rd
6" OFF 2nd
FULL 1 st
NOA No.: 14-1022.20
MIAMI•DADECOUNTY Expiration Date: 02/21/17
Approval Date: 02/05/15
Page 5 of G
DETAIL B
OVERALL DIMENSIONS AND NAILING PA'T'TERN
(- 39-3/81' ---;-i
— 14-1/2"-17-1/2" 14-1/2"-17-1/2" —:
(388-445mm) (368-445mm)
6-1/2"-9-1/2"
�__._ +•
l"guide
line
(t65.24imm) —Nall
6-1l4"3- /tryes-24,m( -34
7n (146mm
-159mm)
(13-64 5t` from bottom of shingle
71 Self seal
adhesive
on back
ENHANCED NAILING PATTERN - six nails per shingle*
required by some local codes and required for enhanced wind coverage on certain products.
See limited warranty for details.
These shingles MUST be nailed a nominal 6" (152mm)from bottom of
of shingle, above the cut outs, as shown. Nails must not be exposed.
END OF THIS ACCEPTANCE
MIAMi•QADE COUNTY
NOA No.: 14-1022.20
• 0W Expiration Dale: 02/21/17
Approval Date: 02/0.5/15